Pulse contour cardiac output derived from non‐invasive arterial pressure in cardiovascular disease
The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
Summary: Pulse contour methods determine cardiac output semi‐invasively using standard arterial access. This study assessed whether cardiac output can be determined non‐invasively by replacing the intra‐arterial pressure input with a non‐invasive finger arterial pressure input in two methods, Nexfin CO‐trek ® and Modelflow ® , in 25 awake patients after coronary artery bypass surgery. Pulmonary artery thermodilution cardiac output served as a reference. In the supine position, the mean (SD) differences between thermodilution cardiac output and Nexfin CO‐trek were 0.22 (0.77) and 0.44 (0.81) l.min −1 , for intra‐arterial and non‐invasive pressures, respectively. For Modelflow, these differences were 0.70 (1.08) and 1.80 (1.59) l.min −1 , respectively. Similarly, in the sitting position, differences between thermodilution cardiac output and Nexfin CO‐trek were 0.16 (0.78) and 0.34 (0.83), for intra‐arterial and non‐invasive arterial pressure, respectively. For Modelflow, these differences were 0.58 (1.11) and 1.52 (1.54) l.min −1 , respectively. Thus, Nexfin CO‐trek readings were not different from thermodilution cardiac output, for both invasive and non‐invasive inputs. However, Modelflow readings differed greatly from thermodilution when using non‐invasive arterial pressure input.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Critchley, L. A. H., & Critchley, J. A. J. H. (1999) · Journal of Clinical Monitoring and Computing · doi:10.1023/a:1009982611386 · Cited by 1,325
Westerhof, N., Lankhaar, J.-W., & Westerhof, B. E. (2009) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-008-0359-2 · Cited by 1,181
Self-citationComputation of aortic flow from pressure in humans using a nonlinear, three-element model
Wesseling, K. H., Jansen, J. R., Settels, J. J., & Schreuder, J. J. (1993) · Journal of Applied Physiology · doi:10.1152/jappl.1993.74.5.2566 · Cited by 1,137
Self-citationShah, M. R., Hasselblad, V., Stevenson, L. W., Binanay, C., O’Connor, C. M., Sopko, G., & Califf, R. M. (2005) · JAMA · doi:10.1001/jama.294.13.1664 · Cited by 790
Wakeling, H. G., McFall, M. R., Jenkins, C. S., Woods, W. G. A., Miles, W. F. A., Barclay, G. R., & Fleming, S. C. (2005) · British Journal of Anaesthesia · doi:10.1093/bja/aei223 · Cited by 606
Jansen, J. R. C., Schreuder, J. J., Mulier, J. P., Smith, N. T., Settels, J. J., & Wesseling, K. H. (2001) · British Journal of Anaesthesia · doi:10.1093/bja/87.2.212 · Cited by 583
Self-citationAn artificial arterial system for pumping hearts.
Westerhof, N., Elzinga, G., & Sipkema, P. (1971) · Journal of Applied Physiology · doi:10.1152/jappl.1971.31.5.776 · Cited by 556
Photoelectric measurement of blood pressure, volume and flow in the finger
Peňáz, J. (1973) · Medical Entomology and Zoology · Cited by 529
Direct Blood Pressure Measurement —Dynamic Response Requirements
Gardner, R. M. (1981) · Anesthesiology · doi:10.1097/00000542-198103000-00010 · Cited by 518
Venn, R., Steele, A., Richardson, P., Poloniecki, J., Grounds, M., & Newman, P. (2002) · British Journal of Anaesthesia · doi:10.1093/bja/88.1.65 · Cited by 458
Non‐invasive pulsatile arterial pressure and stroke volume changes from the human finger
Bogert, L. W. J., & van Lieshout, J. J. (2005) · Experimental Physiology · doi:10.1113/expphysiol.2005.030262 · Cited by 413
Self-citationReconstruction of Brachial Artery Pressure From Noninvasive Finger Pressure Measurements
Bos, W. J. W., van Goudoever, J., van Montfrans, G. A., van den Meiracker, A. H., & Wesseling, K. H. (1996) · Circulation · doi:10.1161/01.cir.94.8.1870 · Cited by 365
Self-citationHARMS, M. P. M., WESSELING, K. H., POTT, F., JENSTRUP, M., VAN GOUDOEVER, J., SECHER, N. H., & VAN LIESHOUT, J. J. (1999) · Clinical Science · doi:10.1042/cs0970291 · Cited by 345
Self-citationMonitoring of peri‐operative fluid administration by individualized goal‐directed therapy
Bundgaard‐Nielsen, M., Holte, K., Secher, N. H., & Kehlet, H. (2007) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2006.01221.x · Cited by 250
Sugawara, J., Tanabe, T., Miyachi, M., Yamamoto, K., Takahashi, K., Iemitsu, M., Otsuki, T., Homma, S., Maeda, S., Ajisaka, R., et al. (2003) · Acta Physiologica Scandinavica · doi:10.1046/j.0001-6772.2003.01211.x · Cited by 230
Physiocal, calibrating finger vascular physiology for finapres
Wesseling, K. H., Wit, B. D., van der Hoeven, G. M. A., Goudoever, J. V., & Settels, J. J. (1995) · TU/e Research Portal · Cited by 229
Self-citationJellema, W. T., Wesseling, K. H., Groeneveld, J. A. B., Stoutenbeek, C. P., Thijs, L. G., & van Lieshout, J. J. (1999) · Anesthesiology · doi:10.1097/00000542-199905000-00016 · Cited by 213
Self-citationRespiration‐synchronous fluctuations in stroke volume, heart rate and arterial pressure in humans.
Toska, K., & Eriksen, M. (1993) · The Journal of Physiology · doi:10.1113/jphysiol.1993.sp019958 · Cited by 212
Validation of brachial artery pressure reconstruction from finger arterial pressure
Guelen, I., Westerhof, B. E., van der Sar, G. L., van Montfrans, G. A., Kiemeneij, F., Wesseling, K. H., & Bos, W. J. W. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e3282fe1d28 · Cited by 186
Self-citationEffects of peripheral vasoconstriction on the measurement of blood pressure in a finger
WESSELING, K. H., SETTELS, J. J., HOEVEN, G. M. A. V. D., NIJBOER, J. A., BUTIJN, M. W. T., & DORLAS, J. C. (1985) · Cardiovascular Research · doi:10.1093/cvr/19.3.139 · Cited by 164
Self-citationBeat-to-beat noninvasive stroke volume from arterial pressure and Doppler ultrasound
LIESHOUT, J. J. V., Toska, K., van Lieshout, E. J., Eriksen, M., Walløe, L., & Wesseling, K. H. (2003) · European Journal of Applied Physiology · doi:10.1007/s00421-003-0901-8 · Cited by 149
Self-citationModels of brachial to finger pulse wave distortion and pressure decrement
Gizdulich, P., Prentza, A., & Wesseling, K. H. (1997) · Cardiovascular Research · doi:10.1016/s0008-6363(97)00003-5 · Cited by 147
Self-citationCriteria for set point estimation in the volume clamp method of blood pressure measurement.
Peňáz, J. (1992) · PubMed · Cited by 122
Improvement of cardiac output estimation by the thermodilution method during mechanical ventilation
Jansen, J. R. C., & Versprille, A. (1986) · Intensive Care Medicine · doi:10.1007/bf00254515 · Cited by 114
Goal-directed Perioperative Fluid Management
Kehlet, H., & Bundgaard‐Nielsen, M. (2009) · Anesthesiology · doi:10.1097/aln.0b013e3181984217 · Cited by 77
Arterial pressure transfer characteristics: effects of travel time
Westerhof, B. E., Guelen, I., Stok, W. J., Wesseling, K. H., Spaan, J. A. E., Westerhof, N., Bos, W. J. W., & Stergiopulos, N. (2006) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00443.2006 · Cited by 56
Self-citationTruijen, J., Bundgaard‐Nielsen, M., & LIESHOUT, J. J. V. (2010) · European Journal of Applied Physiology · doi:10.1007/s00421-009-1346-5 · Cited by 45
Nissen, P., LIESHOUT, J. J. V., Novovic, S., Bundgaard‐Nielsen, M., & Secher, N. H. (2009) · Liver Transplantation · doi:10.1002/lt.21689 · Cited by 39
Reconstruction of brachial pressure from finger arterial pressure during orthostasis
Bogert, L. W. J., Harms, M. P. M., Pott, F. C., Secher, N. H., Wesseling, K. H., & LIESHOUT, J. J. V. (2004) · Journal of Hypertension · doi:10.1097/00004872-200410000-00008 · Cited by 33
Self-citation
Cited by
Perioperative cardiovascular monitoring of high-risk patients: a consensus of 12
Vincent, J.-L., Pelosi, P., Pearse, R., Payen, D., Perel, A., Hoeft, A., Romagnoli, S., Ranieri, V. M., Ichai, C., Forget, P., et al. (2015) · Critical Care · doi:10.1186/s13054-015-0932-7 · Cited by 243
“CO, cardiac output; PAC, pulmonary artery catheter; PPV, pulse pressure variation; ScvO2, central venous oxygen saturation.”
ResultInfluentialA Randomized Trial of Continuous Noninvasive Blood Pressure Monitoring During Noncardiac Surgery
Maheshwari, K., Khanna, S., Bajracharya, G. R., Makarova, N., Riter, Q., Raza, S., Cywinski, J. B., Argalious, M., Kurz, A., & Sessler, D. I. (2018) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000003482 · Cited by 173
Noninvasive continuous hemodynamic monitoring
Truijen, J., van Lieshout, J. J., Wesselink, W. A., & Westerhof, B. E. (2012) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-012-9375-8 · Cited by 161
“The earlier Modelflow CO-method, developed to be used with invasively measured pressures, performed less well on noninvasive measured BP [58].”
BackgroundMethodInfluentialSelf-citationParati, G., Torlasco, C., Omboni, S., & Pellegrini, D. (2017) · Current Hypertension Reports · doi:10.1007/s11906-017-0743-0 · Cited by 75
Smits, M. M., Muskiet, M. H. A., Tonneijck, L., Hoekstra, T., Kramer, M. H. H., Diamant, M., & van Raalte, D. H. (2016) · British Journal of Clinical Pharmacology · doi:10.1111/bcp.12843 · Cited by 60
Metadata
- Authors
- Bogert, L. W. J., Wesseling, K. H., Schraa, O., Van Lieshout, E. J., De Mol, B. A. J. M., Van Goudoever, J., Westerhof, B. E., & Van Lieshout, J. J.
- Venue
- Anaesthesia
- Publisher
- Wiley
- Published
- 2010-09-21
- Volume
- 65
- Issue
- 11
- Pages
- 1119-1125
- ISSN
- 0003-2409 (ISSN-L)
- 1365-2044
- OpenAlex
- W1568936177
- Cited by
- 202
- References
- 30
- FWCI
- 12.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.