Use of the DirecNet Applied Treatment Algorithm (DATA) for diabetes management with a real-time continuous glucose monitor (the FreeStyle Navigator)
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
BACKGROUND: There are no published guidelines for use of real-time continuous glucose monitoring data by a patient; we therefore developed the DirecNet Applied Treatment Algorithm (DATA). The DATA provides algorithms for making diabetes management decisions using glucose values: (i) in real time which include the direction and rate of change of glucose levels, and (ii) retrospectively based on downloaded sensor data. OBJECTIVE: To evaluate the use and effectiveness of the DATA in children with diabetes using a real-time continuous glucose sensor (the FreeStyle Navigator). SUBJECTS: Thirty children and adolescents (mean +/- standard deviation age = 11.2 +/- 4.1 yr) receiving insulin pump therapy. METHODS: Subjects were instructed on use of the DATA and were asked to download their Navigator weekly to review glucose patterns. An Algorithm Satisfaction Questionnaire was completed at 3, 7, and 13 wk. RESULTS: At 13 wk, all of the subjects and all but one parent thought that the DATA gave good, clear directions for insulin dosing, and thought the guidelines improved their postprandial glucose levels. In responding to alarms, 86% of patients used the DATA at least 50% of the time at 3 wk, and 59% reported doing so at 13 wk. Similar results were seen in using the DATA to adjust premeal bolus doses of insulin. CONCLUSIONS: These results show the feasibility of implementing the DATA when real-time continuous glucose monitoring is initiated and support its use in future clinical trials of real-time continuous glucose monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Malmberg, K., Rydén, L., Efendic, S., Herlitz, J., Nicol, P., Waldenstrom, A., Wedel, H., & Welin, L. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)00126-k · Cited by 1,560
Furnary, A. P., Gao, G., Grunkemeier, G. L., Wu, Y., Zerr, K. J., Bookin, S. O., Floten, H. S., & Starr, A. (2003) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1067/mtc.2003.181 · Cited by 1,130
Deiss, D., Bolinder, J., Riveline, J.-P., Battelino, T., Bosi, E., Tubiana-Rufi, N., Kerr, D., & Phillip, M. (2006) · Diabetes Care · doi:10.2337/dc06-1134 · Cited by 539
Cited by
Continuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559
9. Pharmacologic Approaches to Glycemic Treatment: Standards of Care in Diabetes—2025
American Diabetes Association Professional Practice Committee, ElSayed, N. A., McCoy, R. G., Aleppo, G., Bajaj, M., Balapattabi, K., Beverly, E. A., Briggs Early, K., Bruemmer, D., Echouffo-Tcheugui, J. B., et al. (2025) · Diabetes Care · doi:10.2337/dc25-s009 · Cited by 728
9. Pharmacologic Approaches to Glycemic Treatment: Standards of Care in Diabetes—2024
American Diabetes Association Professional Practice Committee, ElSayed, N. A., Aleppo, G., Bannuru, R. R., Bruemmer, D., Collins, B. S., Ekhlaspour, L., Gaglia, J. L., Hilliard, M. E., Johnson, E. L., et al. (2024) · Diabetes Care · doi:10.2337/dc24-s009 · Cited by 662
The effect of continuous glucose monitoring in well-controlled type 1 diabetes
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2009) · Diabetes Care · doi:10.2337/dc09-0108 · Cited by 399
A Tale of Two Compartments: Interstitial Versus Blood Glucose Monitoring
Cengiz, E., & Tamborlane, W. V. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2009.0002 · Cited by 390
Continuous glucose monitoring: A review of the technology and clinical use
Klonoff, D. C., Ahn, D., & Drincic, A. (2017) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2017.08.005 · Cited by 320
Effectiveness of Continuous Glucose Monitoring in a Clinical Care Environment
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2010) · Diabetes Care · doi:10.2337/dc09-1502 · Cited by 313
9. pharmacologic approaches to glycemic treatment: standards of care in diabetes—2026
American Diabetes Association Professional Practice Committee for Diabetes*, Bajaj, M., McCoy, R. G., Balapattabi, K., Bannuru, R. R., Bellini, N. J., Bennett, A. K., Beverly, E. A., Briggs Early, K., ChallaSivaKanaka, S., et al. (2026) · Diabetes Care · doi:10.2337/dc26-s009 · Cited by 263
Wearable Continuous Glucose Monitoring Sensors: A Revolution in Diabetes Treatment
Cappon, G., Acciaroli, G., Vettoretti, M., Facchinetti, A., & Sparacino, G. (2017) · Electronics · doi:10.3390/electronics6030065 · Cited by 237
“In [72], a rule was proposed to empirically adjusting in Equation (1) the current G C according to ROC, in order to suitably alter the total amount of insulin to inject, while in [73], the whole meal dose was modulated according to ROC by a fixed percentage.”
MethodContinuous glucose monitoring: an Endocrine Society Clinical Practice Guideline
Klonoff, D. C., Buckingham, B., Christiansen, J. S., Montori, V. M., Tamborlane, W. V., Vigersky, R. A., & Wolpert, H. (2011) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2010-2756 · Cited by 211
ISPAD Clinical Practice Consensus Guidelines 2018: diabetes technologies
Sherr, J. L., Tauschmann, M., Battelino, T., de Bock, M., Forlenza, G., Roman, R., Hood, K. K., & Maahs, D. M. (2018) · Pediatric Diabetes · doi:10.1111/pedi.12731 · Cited by 197
Advanced Diabetes Management Using Artificial Intelligence and Continuous Glucose Monitoring Sensors
Vettoretti, M., Cappon, G., Facchinetti, A., & Sparacino, G. (2020) · Sensors · doi:10.3390/s20143870 · Cited by 176
Heinemann, L., Schoemaker, M., Schmelzeisen-Redecker, G., Hinzmann, R., Kassab, A., Freckmann, G., Reiterer, F., & Del Re, L. (2020) · Journal of Diabetes Science and Technology · doi:10.1177/1932296819855670 · Cited by 170
Laffel, L. M., Aleppo, G., Buckingham, B. A., Forlenza, G. P., Rasbach, L. E., Tsalikian, E., Weinzimer, S. A., & Harris, D. R. (2017) · Journal of the Endocrine Society · doi:10.1210/js.2017-00389 · Cited by 79
Joubert, M., & Reznik, Y. (2012) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2011.12.010 · Cited by 70
Machine-Learning Based Model to Improve Insulin Bolus Calculation in Type 1 Diabetes Therapy
Noaro, G., Cappon, G., Vettoretti, M., Sparacino, G., Favero, S. D., & Facchinetti, A. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2020.3004031 · Cited by 57
Cappon, G., Marturano, F., Vettoretti, M., Facchinetti, A., & Sparacino, G. (2019) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818777524 · Cited by 18
Metadata
- Authors
- Diabetes Research In Children Network (DirecNet) Study Group*
- Venue
- Pediatric Diabetes
- Publisher
- Hindawi Limited
- Published
- 2008-04
- Volume
- 9
- Issue
- 2
- Pages
- 142-147
- ISSN
- 1399-543X (ISSN-L)
- 1399-5448
- OpenAlex
- W1872020495
- Cited by
- 109
- References
- 3
- FWCI
- 7.19
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.