The mixing of weak LA samples may introduce loss of detectable LA activity and false-negativity give rise to inaccurate interpretation if the mixing test result is employed as a decision point for subsequent confirmatory test performance.
“The mixing of weak LA samples may introduce loss of detectable LA activity and the false‐negativity give rise to inaccurate interpretation if the mixing test result is employed as a decision point for subsequent confirmatory test performance.14, 31, 32, 33”
Cites
Levine, J. S., Branch, D. W., & Rauch, J. (2002) · New England Journal of Medicine · doi:10.1056/nejmra002974 · Cited by 1,524 · see citing works
Brandt, J. T., Triplett, D. A., Alving, B. M., & Scharrer, I. (1995) · PubMed · Cited by 1,164 · see citing works
Brandt, J. T., Triplett, D. A., Alving, B., & Scharrer, I. (1995) · Thrombosis and Haemostasis · doi:10.1055/s-0038-1649901 · Cited by 993 · see citing works
Guidelines on the investigation and management of antiphospholipid syndrome
Keeling, D., Mackie, I., Moore, G. W., Greer, I. A., Greaves, M., & British Committee for Standards in Haematology (2012) · British Journal of Haematology · doi:10.1111/j.1365-2141.2012.09037.x · Cited by 740 · see citing works
Guidelines On The Investigation and Management Of The Antiphospholipid Syndrome
Greaves, M., Cohen, H., Machin, S. J., & Mackie, I. J. (2000) · British Journal of Haematology · doi:10.1046/j.1365-2141.2000.02069.x · Cited by 294 · see citing works
Tripodi, A., Chantarangkul, V., Clerici, M., & Mannucci, P. M. (2002) · PubMed · Cited by 62 · see citing works
Gardiner, C., Mackie, I. J., Malía, R. G., Jones, D. W., Winter, M. R., Leeming, D., Taberner, D. A., Machin, S. J., & Greaves, M. (2000) · British Journal of Haematology · doi:10.1046/j.1365-2141.2000.02466.x · Cited by 55 · see citing works
Laboratory Diagnosis of Lupus Anticoagulants for Patients on Oral Anticoagulant Treatment
Chantarangkul, V., Clerici, M., Mannucci, P. M., & Tripodi, A. (2002) · Thrombosis and Haemostasis · doi:10.1055/s-0037-1613259 · Cited by 43 · see citing works
Tripodi, A., & van den Besselaar, M. H. P. A. (2002) · Thrombosis and Haemostasis · doi:10.1055/s-0037-1613238 · Cited by 32 · see citing works
Gardiner, C., Mackie, I. J., Malía, R. G., et al. (2000) · British Journal of Haematology · doi:10.1111/j.1365-2141.2000.02466.x · Cited by 18 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Guidelines on the investigation and management of antiphospholipid syndrome
Keeling, D., Mackie, I., Moore, G. W., Greer, I. A., Greaves, M., & British Committee for Standards in Haematology (2012) · British Journal of Haematology · doi:10.1111/j.1365-2141.2012.09037.x · Cited by 740 · see citing works
An Acoustofluidic Micromixer via Bubble Inception and Cavitation from Microchannel Sidewalls
Özçelik, A., Ahmed, D., Xie, Y., Nama, N., Qu, Z., Nawaz, A., & Huang, T. J. (2014) · Analytical Chemistry · doi:10.1021/ac5007798 · Cited by 160 · see citing works
Recent Guidelines and Recommendations for Laboratory Detection of Lupus Anticoagulants
Moore, G. (2014) · Seminars in Thrombosis and Hemostasis · doi:10.1055/s-0033-1364185 · Cited by 148 · see citing works
Coagulation assays and anticoagulant monitoring
Funk, D. M. A. (2012) · Hematology · doi:10.1182/asheducation.v2012.1.460.3798662 · Cited by 106 · see citing works
Laboratory investigation of lupus anticoagulants: mixing studies are sometimes required
FAVALORO, E. J., BONAR, R., ZEBELJAN, D., KERSHAW, G., & MARSDEN, K. (2010) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2010.04090.x · Cited by 48 · see citing works
Moore, G. W., & Savidge, G. F. (2006) · Thrombosis Research · doi:10.1016/j.thromres.2005.09.010 · Cited by 46 · see citing works
Interpretation of normal plasma mixing studies in the laboratory diagnosis of lupus anticoagulants
Devreese, K. M. J. (2007) · Thrombosis Research · doi:10.1016/j.thromres.2006.03.012 · Cited by 46 · see citing works
Moore, G. W., Culhane, A. P., Daw, C. R., Noronha, C. P., & Kumano, O. (2016) · Thrombosis Research · doi:10.1016/j.thromres.2016.01.019 · Cited by 42 · see citing works
Commonalities and contrasts in recent guidelines for lupus anticoagulant detection
Moore, G. W. (2014) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.12227 · Cited by 41 · see citing works
Current Controversies in Lupus Anticoagulant Detection
Moore, G. (2016) · Antibodies · doi:10.3390/antib5040022 · Cited by 36 · see citing works
Favaloro, E. J., & Wong, R. C. W. (2011) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2011.064 · Cited by 36 · see citing works
Are laboratories following published recommendations for lupus anticoagulant testing?
Moffat, K. A., Ledford-Kraemer, M., Plumhoff, E., McKay, H., Nichols, W., Meijer, P., & Hayward, C. P. M. (2008) · Thrombosis and Haemostasis · doi:10.1160/th08-06-0353 · Cited by 30 · see citing works
Kumano, O., & Moore, G. W. (2018) · Research and Practice in Thrombosis and Haemostasis · doi:10.1002/rth2.12069 · Cited by 26 · see citing works
Clinical significance of the mixing test in laboratory diagnoses of lupus anticoagulant
Hong, S. K., Hwang, S. M., Kim, J.-E., & Kim, H. K. (2012) · Blood Coagulation & Fibrinolysis · doi:10.1097/mbc.0b013e328358e899 · Cited by 22 · see citing works
<i>In</i> ECAT <i>veritas?</i>
Reber, G., & Meijer, P. (2012) · Lupus · doi:10.1177/0961203312446389 · Cited by 21 · see citing works
Biguzzi, E., Asti, D., Palmucci, C., Tripodi, A., & Chantarangkul, V. (2013) · Thrombosis and Haemostasis · doi:10.1160/th12-11-0850 · Cited by 21 · see citing works
Mixing studies for lupus anticoagulant: mostly no, sometimes yes
Moore, G. W. (2020) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2019-1248 · Cited by 19 · see citing works
Kumano, O., Ieko, M., Naito, S., Yoshida, M., Takahashi, N., Suzuki, T., & Aoki, T. (2014) · Thrombosis Research · doi:10.1016/j.thromres.2014.05.030 · Cited by 15 · see citing works
Favaloro, E. J., Bonar, R., & Marsden, K. (2013) · Blood Coagulation & Fibrinolysis · doi:10.1097/mbc.0b013e328360c71b · Cited by 14 · see citing works
Bonar, R. A., Favaloro, E. J., Zebeljan, D., Rosenfeld, D., Kershaw, G., Mohammed, S., MARSDEN, K. A., & Hertzberg, M. (2011) · Pathology · doi:10.1097/pat.0b013e32834d7b83 · Cited by 12 · see citing works
Variability among commercial batches of normal pooled plasma in lupus anticoagulant testing
Cabo, J., Morimont, L., Baudar, J., Guldenpfennig, M., Jacqmin, H., Soleimani, R., Lecompte, T., Douxfils, J., & Mullier, F. (2022) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.13977 · Cited by 12 · see citing works
Guan, Y., & Sun, B. (2019) · Micromachines · doi:10.3390/mi10120854 · Cited by 12 · see citing works
Chandrashekar, V. (2015) · Blood Coagulation & Fibrinolysis · doi:10.1097/mbc.0000000000000463 · Cited by 11 · see citing works
Aboud, M., RODDIE, C., Wård, C., & Coyle, L. A. (2007) · Clinical Chemistry · doi:10.1373/clinchem.2006.078683 · Cited by 11 · see citing works
Thom, J., Ivey, L., Gilmore, G., et al. (2004) · Blood Coagulation & Fibrinolysis · doi:10.1097/00001721-200406000-00011 · Cited by 6 · see citing works
Self-citationAnalytical dilemmas in lupus anticoagulant detection
Moore, G. W. (2023) · Exploration of Immunology · doi:10.37349/ei.2023.00104 · Cited by 5 · see citing works
Lupus anticoagulant laboratory diagnosis by applying the 2020 ISTH-SSC guidelines
Talon, L., Fourneyron, V., Senectaire, S., Tardieu, M., Tillier, M., Trapani, A., Trayaud, A., Vaissade, A., Sapin, A.-F. S., Lebreton, A., et al. (2023) · Thrombosis Research · doi:10.1016/j.thromres.2023.02.009 · Cited by 5 · see citing works
Lupus Anticoagulant Testing: Dilute Prothrombin Time (dPT)
Moore, G. W. (2023) · Methods in molecular biology · doi:10.1007/978-1-0716-3175-1_17 · Cited by 5 · see citing works
Lupus Anticoagulants, Antiphospholipid Antibodies, and Antiphospholipid Syndrome
Nichols, W. L., Kottke‐Marchant, K., Ledford-Kraemer, M., Homburger, H. A., & Cardel, L. K. (2012) · Wiley eBooks · doi:10.1002/9781444398595.ch39 · Cited by 6 · see citing works
The laboratory diagnosis of lupus anticoagulant in patients on oral anticoagulation
ABOUD, M. R., Roddie, C., Wård, C., & Coyle, L. A. (2006) · Clinical & Laboratory Haematology · doi:10.1111/j.1365-2257.2006.00753.x · Cited by 4 · see citing works
More on: normal plasma mixing studies in the laboratory diagnosis of lupus anticoagulant
Chang, S. (2004) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2004.00847.x · Cited by 4 · see citing works
Morelli, V. M., Arrais‐Rodrigues, C., Noguti, M. A. E., Matos, M. F., da Silveira, R. C., Ribeiro, A. A. M., & Lourenço, D. M. (2007) · Blood Coagulation & Fibrinolysis · doi:10.1097/mbc.0b013e32814fcc50 · Cited by 3 · see citing works
Bauçà, J. M., Ajzner, É., Cadamuro, J., et al. (2022) · Clinica Chimica Acta · doi:10.1016/j.cca.2022.08.026 · Cited by 2 · see citing works
Testing lupus anticoagulants in a real-life scenario - a retrospective cohort study
Ratzinger, F., Panić‐Janković, T., Haslacher, H., Perkmann, T., Schmetterer, K. G., Belik, S., Maenner, G., Pabinger, I., & Quehenberger, P. (2017) · Biochemia Medica · doi:10.11613/bm.2017.030705 · Cited by 2 · see citing works
Labordiagnostik von Lupushemmstoffen
Wagner, O., & Quehenberger, P. (2005) · Hämostaseologie · doi:10.1055/s-0037-1619644 · Cited by 2 · see citing works
Aljabry, M. S. (2015) · Annals of Saudi Medicine · doi:10.5144/0256-4947.2015.383 · Cited by 1 · see citing works
Antiphospholipid Antibodies and Syndrome
Cervera, R. (2018) · MDPI eBooks · doi:10.3390/books978-3-03842-948-7 · Cited by 3 · see citing works
Klinik und Diagnostik des Antiphospholipid-Syndroms
Hempel, M., & Bergmann, F. (2008) · Hämostaseologie · doi:10.1055/s-0037-1617172
SPECIAL ARTICLE In ECAT veritas
Reber, G., & Meijer, P. (2012)
- Authors
- Thom, J., Ivey, L., & Eikelboom, J.
- Affiliations
- Royal Perth Hospital (AU)
- Corresponding author
- Thom, J.
- ORCID
- Eikelboom, J.
- Venue
- Journal of Thrombosis and Haemostasis
- Publisher
- Elsevier BV
- Published
- 2003-12
- Volume
- 1
- Issue
- 12
- Pages
- 2689-2691
- ISSN
- 1538-7836 (ISSN-L)
- OpenAlex
- W2022577109
- Cited by
- 39
- References
- 10
- Citations by year
- 2023: 3 · 2022: 2 · 2019: 2 · 2018: 1 · 2017: 2 · 2016: 2 · 2015: 2 · 2014: 4 · 2013: 2 · 2012: 6
- FWCI
- 1.15
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- Journal of Thrombosis and Haemostasis (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Rheumatology › Systemic Lupus Erythematosus Research
- Health Sciences › Medicine › Hematology › Blood Coagulation and Thrombosis Mechanisms
- Health Sciences › Medicine › Surgery › Heparin-Induced Thrombocytopenia and Thrombosis
- Keywords
- lupus anticoagulant, oral anticoagulants, warfarin, false-negative results, activated partial thromboplastin time, coagulation factor deficiency, venous thromboembolism, arterial thrombosis
- MeSH terms
- Blood Coagulation Tests, Humans, Phospholipids, Plasma, Case-Control Studies, Lupus Coagulation Inhibitor, Clinical Laboratory Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review