The frequency response of frog muscle spindles under various conditions
Open accessAbstract
1. Nerve impulses were recorded from afferents from non‐contracting spindles from the isolated extensor longus dig. IV muscle of the frog during small sinusoidal changes in muscle length at frequencies from 0·001 to 100 Hz. A computer of average transients was used to average the spike distribution during a number of cycles, and hence to determine the spindle response in impulses/sec at different phases of the cycle. 2. At any one frequency the response could be described by a sinusoid, whose amplitude was approximately proportional to the amplitude of the stretch and whose phase was approximately constant, together with a non‐linearity dependent principally upon non‐linearities in the static response. 3. The frequency response was estimated from the sinusoid responses. In conventional terms, it consisted of a straight line of positive slope below 2 Hz and a maximum between 7 and 16 Hz. 4. The slope of the frequency response was dependent on the mean length of the preparation, typically varying from zero to about 0·5 (3 db/octave) over the physiological range of the passive muscle. The shape of the peak appeared to depend on the mean firing frequency. 5. The responses to ramp stretches of one second duration and up to 2 mm in amplitude were also measured. Responses predicted from the sinusoid measurements were the same shape as the measured responses, but were larger by a factor of about 1·4. 6. The shapes of both the frequency responses and the responses to ramps were hardly affected by an operation that removed most of the polar parts of the spindles. 7. The results are discussed in terms of internal spindle mechanisms.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The text we found for this paper looks like another document, so the self-check wasn’t run.
Cites
The sensitivity of muscle spindle afferents to small sinusoidal changes of length
Matthews, P. B. C., & Stein, R. B. (1969) · The Journal of Physiology · doi:10.1113/jphysiol.1969.sp008719 · Cited by 748 · see citing works
Muscle Spindles and Their Motor Control
Matthews, P. B. C. (1964) · Physiological Reviews · doi:10.1152/physrev.1964.44.2.219 · Cited by 571 · see citing works
Changes in time scale and sensitivity in the ommatidia of Limulus
Fuortes, M. G. F., & Hodgkin, A. L. (1964) · The Journal of Physiology · doi:10.1113/jphysiol.1964.sp007415 · Cited by 518 · see citing works
Quantitative description of linear behavior of mammalian muscle spindles.
Poppele, R. E., & Bowman, R. J. (1970) · Journal of Neurophysiology · doi:10.1152/jn.1970.33.1.59 · Cited by 329 · see citing works
The response of a single end organ
Matthews, B. H. C. (1931) · The Journal of Physiology · doi:10.1113/jphysiol.1931.sp002718 · Cited by 319 · see citing works
Biological control systems analysis
Milsum, J. H. (1966) · Medical Entomology and Zoology · Cited by 308 · see citing works
The spindle and extrafusal innervation of a frog muscle
Gray, E. G. (1957) · Proceedings of the Royal Society B Biological Sciences · doi:10.1098/rspb.1957.0021 · Cited by 129 · see citing works
A Linear Transfer Function underlying Impulse Frequency Modulation in a Cockroach Mechanoreceptor
Chapman, K. M., & Smith, R. S. (1963) · Nature · doi:10.1038/197699a0 · Cited by 118 · see citing works
Frequency analysis of stretch reflex and its main subsystems in triceps surae muscles of the cat.
Rosenthal, N. P., McKean, T. A., Roberts, W. J., et al. (1970) · Journal of Neurophysiology · doi:10.1152/jn.1970.33.6.713 · Cited by 117 · see citing works
Myotatic Reflex: Its Input-Output Relation
Poppele, R. E., & Terzuolo, C. A. (1968) · Science · doi:10.1126/science.159.3816.743 · Cited by 100 · see citing works
Retinal ganglion cell response to sinusoidal light stimulation.
Hughes, G. W., & Maffei, L. (1966) · Journal of Neurophysiology · doi:10.1152/jn.1966.29.3.333 · Cited by 89 · see citing works
A model of adaptation in amphibian spindle receptors
Houk, J. C., Cornew, R. W., & Stark, L. R. (1966) · Journal of Theoretical Biology · doi:10.1016/0022-5193(66)90113-5 · Cited by 54 · see citing works
Response of the Isolated Muscle Spindle to Different Rates of StretchingPreprint
Shepherd, G. M., & Ottoson, D. (1965) · Cold Spring Harbor Symposia on Quantitative Biology · doi:10.1101/sqb.1965.030.01.013 · Cited by 48 · see citing works
Some effects of fast and slow motor fibres on muscle spindles of the frog
Matthews, P. B. C., & Westbury, D. R. (1965) · The Journal of Physiology · doi:10.1113/jphysiol.1965.sp007622 · Cited by 43 · see citing works
The contribution of mechanical factors to the early adaptation of the spindle response
Husmark, I., & Ottoson, D. (1971) · The Journal of Physiology · doi:10.1113/jphysiol.1971.sp009343 · Cited by 42 · see citing works
Length changes within isolated frog muscle spindle during and after stretching
Ottoson, D., & Shepherd, G. M. (1970) · The Journal of Physiology · doi:10.1113/jphysiol.1970.sp009092 · Cited by 38 · see citing works
Feedback theory and its application to biological systems.
Ke, M. (1964) · PubMed · Cited by 36 · see citing works
Sensitivity of isolated frog muscle spondle during and after stretching.
Ottoson, D., McReynolds, J. S., & Shepherd, G. M. (1969) · Journal of Neurophysiology · doi:10.1152/jn.1969.32.1.24 · Cited by 31 · see citing works
The Effect of Acetylcholine and Related Substances on the Isolated Muscle Spindle
Ottoson, D. (1961) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1961.tb02286.x · Cited by 30 · see citing works
AN ANALYSIS OF IMPULSE DISCHARGES FROM THE SPINDLE RECEPTOR
Toyama, K. (1966) · The Japanese Journal of Physiology · doi:10.2170/jjphysiol.16.113 · Cited by 30 · see citing works
Tandem muscle-spindles in the frog.
Barker, D., & Cope, M. (1962) · PubMed · Cited by 25 · see citing works
Reciprocal time-interval display unit
Huxley, A. F., & Pascoe, J. E. (1963) · Cited by 17 · see citing works
Jahn, S. A. A. (1968) · Acta Physiologica Scandinavica · doi:10.1111/j.1365-201x.1968.tb10842.x · Cited by 12 · see citing works
Ito, F. (1969) · The Japanese Journal of Physiology · doi:10.2170/jjphysiol.19.641 · Cited by 12 · see citing works
Jahn, S. A. A. (1968) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1968.tb04247.x · Cited by 8 · see citing works
Response of a frog's muscle spindle
Leeuwen, S. V. (1949) · The Journal of Physiology · doi:10.1113/jphysiol.1949.sp004378 · Cited by 8 · see citing works
Analogues for muscle spindle systems.
Kirkwood, P. (1969) · PubMed · Cited by 2 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845 · see citing works
Hassler, C., Boretius, T., & Stieglitz, T. (2011) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.22169 · Cited by 501 · see citing works
The first 500 patients with sacral anterior root stimulator implants: general description
Brindley, G. S. (1994) · Spinal Cord · doi:10.1038/sc.1994.126 · Cited by 318 · see citing works
Sacral anterior root stimulators for bladder control in paraplegia: the first 50 cases
Brindley, G. S., Polkey, C. E., Rushton, D. N., & Cardozo, L. (1986) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.49.10.1104 · Cited by 313 · see citing works
An implant to empty the bladder or close the urethra.
Brindley, G. S. (1977) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.40.4.358 · Cited by 177 · see citing works
Delivopoulos, E., Chew, D. J., Minev, I. R., Fawcett, J. W., & Lacour, S. P. (2012) · Lab on a Chip · doi:10.1039/c2lc21277c · Cited by 68 · see citing works
Giagka, V., & Serdijn, W. A. (2018) · Bioelectronic Medicine · doi:10.1186/s42234-018-0010-y · Cited by 58 · see citing works
Long‐term biocompatibility of implanted polymer‐based intrafascicular electrodes
Lawrence, S. M., Larsen, J. O., Horch, K. W., Riso, R., & Sinkjær, T. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10303 · Cited by 55 · see citing works
Loeb, G. E., Marks, W. B., & Beatty, P. G. (1977) · Medical & Biological Engineering & Computing · doi:10.1007/bf02442964 · Cited by 46 · see citing works
Liu, X., Demosthenous, A., Vanhoestenberghe, A., Jiang, D., & Donaldson, N. (2012) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2174360 · Cited by 39 · see citing works
- Authors
- Kirkwood, P. A.
- Corresponding author
- Kirkwood, P. A.
- ORCID
- Kirkwood, P. A.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1972-04
- Volume
- 222
- Issue
- 1
- Pages
- 135-160
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- PMC
- PMC1331420
- OpenAlex
- W2041297731
- Cited by
- 63
- References
- 27
- Citations by year
- 2024: 1 · 2023: 2 · 2020: 1 · 2019: 1 · 2018: 1 · 2015: 1 · 2013: 1 · 2012: 2
- FWCI
- 7.86
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- The Journal of Physiology (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Muscle Physiology and Disorders
- Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
- Keywords
- muscle spindles, frequency response, stretch reflex, afferent nerve impulses, firing rate, frogs
- MeSH terms
- Action Potentials, Animals, Anura, Electric Stimulation, Electrophysiology, Models, Biological, Muscles, Muscle Spindles, Neurons, Afferent, Neurophysiology, Periodicity, Rana esculenta, Rana pipiens, Rana temporaria, Viscosity, In Vitro Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review