The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Spatio‐temporal interactions in cat retinal ganglion cells showing linear spatial summation.
Open accessAbstract
The spatio‐temporal characteristics of cat retinal ganglion cells showing linear summation have been studied by measuring both magnitude and phase of the responses of these cells to drifting or sinusoidally contrast‐modulated sinusoidal grating patterns. It has been demonstrated not only that X cells behave approximately linearly when responding with amplitudes of less than about 10 impulses/sec to stimuli of low contrast but also that cells of another type with larger receptive field centres (Q cells) behave approximately linearly under the same conditions. These Q cells appear to form a homogeneous group which is probably a subset of the tonic W cells (Stone & Fukuda, 1974) or sluggish centre‐surround cells (Cleland & Levick, 1974). The over‐all spatio‐temporal frequency characteristics of cells showing linear spatial summation are not separable in space and time. The form of the spatial frequency responsivity function of these cells depends upon the temporal frequency at which it is measured while the temporal phase of their resonse measured at any constant temporal frequency depends upon the spatial frequency of the stimulus. The behaviour of X and Q cells is quite well explained by an extension of the model in which signals from centre and surround mechanisms with radially Gaussian weighting functions are summed to provide the drive to the retinal ganglion cell. While the general form of the temporal frequency response characteristics of these ganglion cells are probably provided by the characteristics of elements common to the centre and surround pathways, the spatio‐temporal interactions can be explained by assuming that the surround signal is delayed relative to the centre signal by a few milliseconds.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The contrast sensitivity of retinal ganglion cells of the cat
Enroth-Cugell, C., & Robson, J. G. (1966) · The Journal of Physiology · doi:10.1113/jphysiol.1966.sp008107 · Cited by 2,625
Self-citationSpatial and Temporal Contrast-Sensitivity Functions of the Visual System
Robson, J. G. (1966) · Journal of the Optical Society of America · doi:10.1364/josa.56.001141 · Cited by 839
Self-citationQuantitative analysis of cat retinal ganglion cell response to visual stimuli
Rodieck, R. W. (1965) · Vision Research · doi:10.1016/0042-6989(65)90033-7 · Cited by 764
Spatial and temporal contrast sensitivity of neurones in areas 17 and 18 of the cat's visual cortex.
Movshon, J. A., Thompson, I. D., & Tolhurst, D. J. (1978) · The Journal of Physiology · doi:10.1113/jphysiol.1978.sp012490 · Cited by 667
ANALYSIS OF RECEPTIVE FIELDS OF CAT RETINAL GANGLION CELLS
Rodieck, R. W., & Stone, J. (1965) · Journal of Neurophysiology · doi:10.1152/jn.1965.28.5.833 · Cited by 558
The effect of contrast on the transfer properties of cat retinal ganglion cells.
Shapley, R. M., & Victor, J. D. (1978) · The Journal of Physiology · doi:10.1113/jphysiol.1978.sp012571 · Cited by 526
Properties of cat retinal ganglion cells: a comparison of W-cells with X- and Y-cells.
Stone, J., & Fukuda, Y. (1974) · Journal of Neurophysiology · doi:10.1152/jn.1974.37.4.722 · Cited by 491
Brisk and sluggish concentrically organized ganglion cells in the cat's retina
Cleland, B. G., & Levick, W. R. (1974) · The Journal of Physiology · doi:10.1113/jphysiol.1974.sp010617 · Cited by 487
Quantitative analysis of retinal ganglion cell classifications.
Hochstein, S., & Shapley, R. M. (1976) · The Journal of Physiology · doi:10.1113/jphysiol.1976.sp011594 · Cited by 477
Correlated firing of cat retinal ganglion cells. I. Spontaneously active inputs to X- and Y-cells
Mastronarde, D. N. (1983) · Journal of Neurophysiology · doi:10.1152/jn.1983.49.2.303 · Cited by 254
Cited by
Dacey, D. M., Liao, H.-W., Peterson, B. B., Robinson, F. R., Smith, V. C., Pokorny, J., Yau, K.-W., & Gamlin, P. D. (2005) · Nature · doi:10.1038/nature03387 · Cited by 1,333
Spatial and temporal contrast sensitivities of neurones in lateral geniculate nucleus of macaque.
Derrington, A. M., & Lennie, P. (1984) · The Journal of Physiology · doi:10.1113/jphysiol.1984.sp015498 · Cited by 1,058
An emergent model of orientation selectivity in cat visual cortical simple cells
Somers, D., Nelson, S., & Sur, M. (1995) · The Journal of Neuroscience · doi:10.1523/jneurosci.15-08-05448.1995 · Cited by 860
Meister, M., & Berry, M. J. (1999) · Neuron · doi:10.1016/s0896-6273(00)80700-x · Cited by 434
A standard model for foveal detection of spatial contrast
Watson, A. B., & Ahumada, A. J. (2005) · Journal of Vision · doi:10.1167/5.9.6 · Cited by 329
Self-citationFireworks in the Primate Retina
Dacey, D. M., Peterson, B. B., Robinson, F. R., & Gamlin, P. D. (2003) · Neuron · doi:10.1016/s0896-6273(02)01143-1 · Cited by 320
The most numerous ganglion cell type of the mouse retina is a selective feature detector
Zhang, Y., Kim, I.-J., Sanes, J. R., & Meister, M. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1211547109 · Cited by 313
Chapter 7 New views of primate retinal function
Kaplan, E., Lee, B. B., & Shapley, R. M. (1990) · Progress in Retinal Research · doi:10.1016/0278-4327(90)90009-7 · Cited by 282
Priebe, N. J., Lisberger, S. G., & Movshon, J. A. (2006) · The Journal of Neuroscience · doi:10.1523/jneurosci.3936-05.2006 · Cited by 273
Cable theory in neurons with active, linearized membranes
Koch, C. (1984) · Biological Cybernetics · doi:10.1007/bf00317936 · Cited by 271
Lateral interactions in the outer retina
Thoreson, W. B., & Mangel, S. C. (2012) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2012.04.003 · Cited by 262
Half-squaring in responses of cat striate cells
Heeger, D. J. (1992) · Visual Neuroscience · doi:10.1017/s095252380001124x · Cited by 262
Egelhaaf, M., Borst, A., & Reichardt, W. (1989) · Journal of the Optical Society of America A · doi:10.1364/josaa.6.001070 · Cited by 259
Functional Imaging of the Human Lateral Geniculate Nucleus and Pulvinar
Kastner, S., O'Connor, D. H., Fukui, M. M., Fehd, H. M., Herwig, U., & Pinsk, M. A. (2004) · Journal of Neurophysiology · doi:10.1152/jn.00553.2003 · Cited by 228
Capabilities of monkey cortical cells in spatial-resolution tasks
Parker, A., & Hawken, M. (1985) · Journal of the Optical Society of America A · doi:10.1364/josaa.2.001101 · Cited by 128
Crook, J. D., Davenport, C. M., Peterson, B. B., Packer, O. S., Detwiler, P. B., & Dacey, D. M. (2009) · Journal of Neuroscience · doi:10.1523/jneurosci.1218-09.2009 · Cited by 116
Reconstruction of natural images from responses of primate retinal ganglion cells
Brackbill, N., Rhoades, C., Kling, A., Shah, N. P., Sher, A., Litke, A. M., & Chichilnisky, E. (2020) · eLife · doi:10.7554/elife.58516 · Cited by 57
Gain, noise, and contrast sensitivity of linear visual neurons
Watson, A. B. (1990) · Visual Neuroscience · doi:10.1017/s0952523800002303 · Cited by 12
Self-citation
Metadata
- Authors
- Enroth‐Cugell, C., Robson, J. G., Schweitzer‐Tong, D. E., & Watson, A. B.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1983-08
- Volume
- 341
- Issue
- 1
- Pages
- 279-307
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W1977097752
- Cited by
- 254
- References
- 19
- FWCI
- 6.74
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.