Single cell detection with micromechanical oscillators
Abstract
The ability to detect small amounts of materials, especially pathogenic bacteria, is important for medical diagnostics and for monitoring the food supply. Engineered micro- and nanomechanical systems can serve as multifunctional, highly sensitive, immunospecific biological detectors. We present a resonant frequency-based mass sensor, comprised of low-stress silicon nitride cantilever beams for the detection of Escherichia coli (E. coli)-cell-antibody binding events with detection sensitivity down to a single cell. The binding events involved the interaction between anti-E. coli O157:H7 antibodies immobilized on a cantilever beam and the O157 antigen present on the surface of pathogenic E. coli O157:H7. Additional mass loading from the specific binding of the E. coli cells was detected by measuring a resonant frequency shift of the micromechanical oscillator. In air, where considerable damping occurs, our device mass sensitivities for a 15 μm and 25 μm long beam were 1.1 Hz/fg and 7.1 Hz/fg, respectively. In both cases, utilizing thermal and ambient noise as a driving mechanism, the sensor was highly effective in detecting immobilized anti-E. coli antibody monolayer assemblies, as well as single E. coli cells. Our results suggest that tailoring of oscillator dimensions is a feasible approach for sensitivity enhancement of resonant mass sensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Binnig, G., Quate, C. F., & Gerber, C. (1986) · Physical Review Letters · doi:10.1103/physrevlett.56.930 · Cited by 14,762
Escherichia coli and Salmonella :cellular and molecular biology
Neidhardt, F. C. (1996) · ASM Press eBooks · Cited by 8,197
Vibration problems in engineering
Timoshenko, S. P. (1928) · CERN Document Server (European Organization for Nuclear Research) · Cited by 3,449
Silicon as a mechanical material
Petersen, K. E. (1982) · Proceedings of the IEEE · doi:10.1109/proc.1982.12331 · Cited by 2,902
Translating Biomolecular Recognition into Nanomechanics
Fritz, J., Baller, M. K., Lang, H. P., Rothuizen, H., Vettiger, P., Meyer, E., -J. Güntherodt, H., Gerber, C., & Gimzewski, J. K. (2000) · Science · doi:10.1126/science.288.5464.316 · Cited by 1,646
Novel optical approach to atomic force microscopy
Meyer, G., & Amer, N. M. (1988) · Applied Physics Letters · doi:10.1063/1.100061 · Cited by 1,290
Hinterdorfer, P., Baumgartner, W., Gruber, H. J., Schilcher, K., & Schindler, H. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.8.3477 · Cited by 1,170
Piezoelectric Sorption Detector.
King, W. H. (1964) · Analytical Chemistry · doi:10.1021/ac60215a012 · Cited by 786
(1996) · Handbook of Microscopy · doi:10.1002/9783527620524.ch13 · Cited by 726
Observation of a chemical reaction using a micromechanical sensor
Gimzewski, J. K., Gerber, C., Meyer, E., & Schlittler, R. R. (1994) · Chemical Physics Letters · doi:10.1016/0009-2614(93)e1419-h · Cited by 469
Cited by
Nanostructures in Biodiagnostics
Rosi, N. L., & Mirkin, C. A. (2005) · Chemical Reviews · doi:10.1021/cr030067f · Cited by 4,603
Cantilever transducers as a platform for chemical and biological sensors
Lavrik, N. V., Sepaniak, M. J., & Datskos, P. G. (2004) · Review of Scientific Instruments · doi:10.1063/1.1763252 · Cited by 1,117
Micro- and nanomechanical sensors for environmental, chemical, and biological detection
Waggoner, P. S., & Craighead, H. G. (2007) · Lab on a Chip · doi:10.1039/b707401h · Cited by 678
Self-citationAttogram detection using nanoelectromechanical oscillators
Ilic, B., Craighead, H. G., Krylov, S., Senaratne, W., Ober, C., & Neuzil, P. (2004) · Journal of Applied Physics · doi:10.1063/1.1650542 · Cited by 585
Self-citationCantilever-like micromechanical sensors
Boisen, A., Dohn, S., Keller, S. S., Schmid, S., & Tenje, M. (2011) · Reports on Progress in Physics · doi:10.1088/0034-4885/74/3/036101 · Cited by 566
Human Occupancy as a Source of Indoor Airborne Bacteria
Hospodsky, D., Qian, J., Nazaroff, W. W., Yamamoto, N., Bibby, K., Rismani-Yazdi, H., & Peccia, J. (2012) · PLoS ONE · doi:10.1371/journal.pone.0034867 · Cited by 562
Single virus particle mass detection using microresonators with nanoscale thickness
Gupta, A., Akin, D., & Bashir, R. (2004) · Applied Physics Letters · doi:10.1063/1.1667011 · Cited by 543
Eom, K., Park, H. S., Yoon, D. S., & Kwon, T. (2011) · Physics Reports · doi:10.1016/j.physrep.2011.03.002 · Cited by 464
Long-term warming restructures Arctic tundra without changing net soil carbon storage
Sistla, S. A., Moore, J. C., Simpson, R. T., Gough, L., Shaver, G. R., & Schimel, J. P. (2013) · Nature · doi:10.1038/nature12129 · Cited by 459
Ultrasensitive mass sensing using mode localization in coupled microcantilevers
Spletzer, M., Raman, A., Wu, A. Q., Xu, X., & Reifenberger, R. (2006) · Applied Physics Letters · doi:10.1063/1.2216889 · Cited by 404
Size‐resolved emission rates of airborne bacteria and fungi in an occupied classroom
Qian, J., Hospodsky, D., Yamamoto, N., Nazaroff, W. W., & Peccia, J. (2012) · Indoor Air · doi:10.1111/j.1600-0668.2012.00769.x · Cited by 395
Biosensors based on nanomechanical systems
Tamayo, J., Kosaka, P. M., Ruz, J. J., San Paulo, Á., & Calleja, M. (2013) · Chem. Soc. Rev. · doi:10.1039/c2cs35293a · Cited by 391
Virus detection using nanoelectromechanical devices
Ilic, B., Yang, Y., & Craighead, H. G. (2004) · Applied Physics Letters · doi:10.1063/1.1794378 · Cited by 365
Self-citationTowards on-site pathogen detection using antibody-based sensors
Skottrup, P. D., Nicolaisen, M., & Justesen, A. F. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.06.045 · Cited by 352
Biosensing using dynamic-mode cantilever sensors: A review
Johnson, B. N., & Mutharasan, R. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.10.054 · Cited by 314
Femtogram mass detection using photothermally actuated nanomechanical resonators
Lavrik, N. V., & Datskos, P. G. (2003) · Applied Physics Letters · doi:10.1063/1.1569050 · Cited by 308
So, H., Park, D., Jeon, E., Kim, Y., Kim, B. S., Lee, C., Choi, S. Y., Kim, S. C., Chang, H., & Lee, J. (2008) · Small · doi:10.1002/smll.200700664 · Cited by 288
Dissipation in nanoelectromechanical systems
Imboden, M., & Mohanty, P. (2014) · Physics Reports · doi:10.1016/j.physrep.2013.09.003 · Cited by 273
Zelada‐Guillén, G. A., Riu, J., Düzgün, A., & Rius, F. X. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200902090 · Cited by 273
Live-cell mass profiling: an emerging approach in quantitative biophysics
Zangle, T. A., & Teitell, M. A. (2014) · Nature Methods · doi:10.1038/nmeth.3175 · Cited by 260
Aponte, V. M., Finch, D. S., & Klaus, D. M. (2006) · Life Sciences · doi:10.1016/j.lfs.2006.04.007 · Cited by 51
“…of disease (Kopp et al., 1998), in the detection of DNA defects (Fritz et al., 2000), cardiovascular monitoring (Najafi and Ludomirsky, 2004), sensing of disease-causing bacteria such as Escherichia coli (Ilic et al., 2001) and cancer cell recognition (Bhalerao et al., 2004), to mention a few.”
Metadata
- Authors
- Ilic, B., Czaplewski, D., Zalalutdinov, M., Craighead, H. G., Neuzil, P., Campagnolo, C., & Batt, C.
- Venue
- Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures Processing, Measurement, and Phenomena
- Publisher
- American Vacuum Society
- Published
- 2001-11-01
- Volume
- 19
- Issue
- 6
- Pages
- 2825-2828
- ISSN
- 1071-1023 (ISSN-L)
- 1520-8567
- OpenAlex
- W1983910981
- Cited by
- 443
- References
- 14
- FWCI
- 17.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.