The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Optical Properties of Circulating Human Blood in the Wavelength Range 400–2500 nm
Open accessAbstract
Knowledge about the optical properties μa,μs, and g of human blood plays an important role for many diagnostic and therapeutic applications in laser medicine and medical diagnostics. They strongly depend on physiological parameters such as oxygen saturation, osmolarity, flow conditions, haematocrit, etc. The integrating sphere technique and inverse Monte Carlo simulations were applied to measure μa,μs, and g of circulating human blood. At 633 nm the optical properties of human blood with a haematocrit of 10% and an oxygen saturation of 98% were found to be 0.210±0.002 mm-1 for μa,77.3±0.5 mm-1 for μs, and 0.994±0.001 for the g factor. An increase of the haematocrit up to 50% lead to a linear increase of absorption and reduced scattering. Variations in osmolarity and wall shear rate led to changes of all three parameters while variations in the oxygen saturation only led to a significant change of the absorption coefficient. A spectrum of all three parameters was measured in the wavelength range 400-2500 nm for oxygenated and deoxygenated blood, showing that blood absorption followed the absorption behavior of haemoglobin and water. The scattering coefficient decreased for wavelengths above 500 nm with approximately λ-1.7; the g factor was higher than 0.9 over the whole wavelength range. © 1999 Society of Photo-Optical Instrumentation Engineers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wave Propagation and Scattering in Random Media
(1978) · Elsevier eBooks · doi:10.1016/c2013-0-10906-3 · Cited by 4,709
Diffuse radiation in the Galaxy
Henyey, L. C., & Greenstein, J. L. (1941) · The Astrophysical Journal · doi:10.1086/144246 · Cited by 2,913
Van Gemert, M. J. C., Jacques, S. L., Sterenborg, H. J. C. M., & Star, W. M. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.42108 · Cited by 807
Ein Beitrag zur Optik der Farbanstriche
Kubelka, P. (1931) · Medical Entomology and Zoology · Cited by 558
Profio, A. E. (1989) · Applied Optics · doi:10.1364/ao.28.002216 · Cited by 305
Extinction and absorption coefficients and scattering phase functions of human tissues in vitro
Marchesini, R., Bertoni, A., Andreola, S., Melloni, E., & Sichirollo, A. E. (1989) · Applied Optics · doi:10.1364/ao.28.002318 · Cited by 225
Flock, S. T., Wilson, B. C., & Patterson, M. S. (1987) · Medical Physics · doi:10.1118/1.596010 · Cited by 212
Reynolds, L., Johnson, C., & Ishimaru, A. (1976) · Applied Optics · doi:10.1364/ao.15.002059 · Cited by 190
Gordy, E., Drabkin, D. L., & Marsh, J. B. (1957) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)70815-6 · Cited by 109
Diffusion model of the optical absorbance of whole blood
Steinke, J. M., & Shepherd, A. P. (1988) · Journal of the Optical Society of America A · doi:10.1364/josaa.5.000813 · Cited by 99
Cited by
Bashkatov, A. N., Genina, E. A., Kochubey, V. I., & Tuchin, V. V. (2005) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/38/15/004 · Cited by 1,720
A Review of Indocyanine Green Fluorescent Imaging in Surgery
Alander, J. T., Kaartinen, I., Laakso, A., Pätilä, T., Spillmann, T., Tuchin, V. V., Venermo, M., & Välisuo, P. (2012) · International Journal of Biomedical Imaging · doi:10.1155/2012/940585 · Cited by 1,352
OPTICAL PROPERTIES OF SKIN, SUBCUTANEOUS, AND MUSCLE TISSUES: A REVIEW
BASHKATOV, A. N., GENINA, E. A., & TUCHIN, V. V. (2011) · Journal of Innovative Optical Health Sciences · doi:10.1142/s1793545811001319 · Cited by 761
Stimuli-responsive LbL capsules and nanoshells for drug delivery
Delcea, M., Möhwald, H., & Skirtach, A. G. (2011) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2011.03.010 · Cited by 685
Salomatina, E. V., Jiang, B., Novak, J., & Yaroslavsky, A. N. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2398928 · Cited by 599
Laser‐Induced Release of Encapsulated Materials inside Living Cells
Skirtach, A. G., Muñoz Javier, A., Kreft, O., Köhler, K., Piera Alberola, A., Möhwald, H., Parak, W. J., & Sukhorukov, G. B. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200504599 · Cited by 492
Stimuli-Responsive Polymers and Their Applications in Nanomedicine
Cabane, E., Zhang, X., Langowska, K., Palivan, C. G., & Meier, W. (2012) · Biointerphases · doi:10.1007/s13758-011-0009-3 · Cited by 468
A literature review and novel theoretical approach on the optical properties of whole blood
Bosschaart, N., Edelman, G. J., Aalders, M. C. G., van Leeuwen, T. G., & Faber, D. J. (2014) · Lasers in Medical Science · doi:10.1007/s10103-013-1446-7 · Cited by 459
Laser‐Induced Release of Encapsulated Materials inside Living Cells
Skirtach, A. G., Muñoz Javier, A., Kreft, O., Köhler, K., Piera Alberola, A., Möhwald, H., Parak, W. J., & Sukhorukov, G. B. (2006) · Angewandte Chemie · doi:10.1002/ange.200504599 · Cited by 455
Deep Learning in Label-free Cell Classification
Chen, C. L., Mahjoubfar, A., Tai, L.-C., Blaby, I. K., Huang, A., Niazi, K. R., & Jalali, B. (2016) · Scientific Reports · doi:10.1038/srep21471 · Cited by 443
A review of in‐vivo optical properties of human tissues and its impact on PDT
Sandell, J. L., & Zhu, T. C. (2011) · Journal of Biophotonics · doi:10.1002/jbio.201100062 · Cited by 384
Extended theory of selective photothermolysis
Altshuler, G. B., Anderson, R. R., Manstein, D., Zenzie, H. H., & Smirnov, M. Z. (2001) · Lasers in Surgery and Medicine · doi:10.1002/lsm.1136 · Cited by 342
Sorg, B. S., Moeller, B. J., Donovan, O., Cao, Y., & Dewhirst, M. W. (2005) · Journal of Biomedical Optics · doi:10.1117/1.2003369 · Cited by 306
Tissue-mimicking phantoms for photoacoustic and ultrasonic imaging
Cook, J. R., Bouchard, R. R., & Emelianov, S. Y. (2011) · Biomedical Optics Express · doi:10.1364/boe.2.003193 · Cited by 285
Friebel, M., Roggan, A., Müller, G., & Meinke, M. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2203659 · Cited by 283
Self-citationOxygen Saturation-Dependent Absorption and Scattering of Blood
Faber, D. J., Aalders, M. C. G., Mik, E. G., Hooper, B. A., van Gemert, M. J. C., & van Leeuwen, T. G. (2004) · Physical Review Letters · doi:10.1103/physrevlett.93.028102 · Cited by 264
Galanzha, E. I., Shashkov, E. V., Spring, P. M., Suen, J. Y., & Zharov, V. P. (2009) · Cancer Research · doi:10.1158/0008-5472.can-08-4900 · Cited by 259
O’Brien, K. P., Khan, S., Gilligan, K. E., Zafar, H., Lalor, P., Glynn, C., O’Flatharta, C., Ingoldsby, H., Dockery, P., De Bhulbh, A., et al. (2018) · Oncogene · doi:10.1038/s41388-017-0116-9 · Cited by 215
Optical Stimulation of Neurons
C. Thompson, A., R. Stoddart, P., & Jansen, E. D. (2015) · Current Molecular Imaging · doi:10.2174/2211555203666141117220611 · Cited by 105
“Absorption coefficient in water [140] and oxygenated blood (5% haematocrit) [141].”
BackgroundMignon, C., Tobin, D. J., Zeitouny, M., & Uzunbajakava, N. E. (2018) · Biomedical Optics Express · doi:10.1364/boe.9.000852 · Cited by 43
Noninvasive optical inhibition with a red-shifted microbial rhodopsin
Chuong, A. S., Miri, M. L., Busskamp, V., Matthews, G. A. C., Acker, L. C., Sørensen, A. T., Young, A., Klapoetke, N. C., Henninger, M. A., Kodandaramaiah, S. B., et al. (2014) · Nature Neuroscience · doi:10.1038/nn.3752 · Cited by 33
Nishimura, G., Kida, I., & Tamura, M. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/11/021 · Cited by 20
Measuring haemolysis in cattle serum by direct UV–VIS and RGB digital image-based methods
Larrán, B., López-Alonso, M., Miranda, M., Pereira, V., Rigueira, L., Suárez, M. L., & Herrero-Latorre, C. (2022) · Scientific Reports · doi:10.1038/s41598-022-17842-4 · Cited by 7
Metadata
- Authors
- Roggan, A., Friebel, M., Dörschel, K., Hahn, A., & Müller, G.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 1999
- Volume
- 4
- Issue
- 1
- Pages
- 36
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W1973846615
- Cited by
- 819
- References
- 11
- FWCI
- 11.85
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.