The DOI matches its Crossref record.
A patient‐to‐computed‐tomography image registration method based on digitally reconstructed radiographs
Abstract
An automatic method for the accurate registration of computed tomography (CT) data with two camera‐calibrated radiographs is presented. The registration is based on the skull as visualized both in the plain radiographs and in radiographs digitally reconstructed from CT. A reference coordinate system is established based on the radiographic projection parameters obtained using an angiographic stereotactic localizer. The CT‐derived reconstructed radiographs are aligned iteratively at multiple resolutions until a best match is found by adjusting the position and orientation of the CT data set relative to the reference coordinate system. The results of experiments with a skull phantom performed under stereotactic control which show that reliable registration is possible with an accuracy better than 1 mm are presented. Possible applications include intraoperative patient‐to‐CT frameless registration and registration of radiographic data with frameless CT for depth electroencephalogram electrode position confirmation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A survey of medical image registration
Maintz, J. B. A., & Viergever, M. A. (1998) · Medical Image Analysis · doi:10.1016/s1361-8415(01)80026-8 · Cited by 3,327
Hill, D. L. G., Batchelor, P. G., Holden, M., & Hawkes, D. J. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/3/201 · Cited by 2,093
A comparison of similarity measures for use in 2-D-3-D medical image registration
Penney, G. P., Weese, J., Little, J. A., Desmedt, P., Hill, D. L. G., & hawkes, D. J. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.730403 · Cited by 782
A Review of 3d/2d Registration Methods for Image-Guided Interventions
Markelj, P., Tomaževič, D., Likar, B., & Pernuš, F. (2012) · Medical Image Analysis · doi:10.1016/j.media.2010.03.005 · Cited by 746
Mahfouz, M. R., Hoff, W. A., Komistek, R. D., & Dennis, D. A. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.820027 · Cited by 305
In vivo determination of normal and anterior cruciate ligament-deficient knee kinematics
Dennis, D. A., Mahfouz, M. R., Komistek, R. D., & Hoff, W. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.02.042 · Cited by 302
Russakoff, D. B., Rohlfing, T., Mori, K., Rueckert, D., Ho, A., Adler, J. R., & Maurer, C. R. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.856749 · Cited by 142
McLaughlin, R. A., Hipwell, J., Hawkes, D. J., Noble, J. A., Byrne, J. V., & Cox, T. C. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.852067 · Cited by 63
van der Bom, I. M. J., Klein, S., Staring, M., Homan, R., Bartels, L. W., & Pluim, J. P. W. (2011) · SPIE Proceedings · doi:10.1117/12.877655 · Cited by 55
3D-2D Registration for Surgical Guidance: Effect of Projection View Angles on Registration Accuracy
Uneri, A., Otake, Y., Wang, A. S., Kleinszig, G., Vogt, S., Khanna, A. J., & Siewerdsen, J. H. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/2/271 · Cited by 53
Birkfellner, W., Stock, M., Figl, M., Gendrin, C., Hummel, J., Dong, S., Kettenbach, J., Georg, D., & Bergmann, H. (2009) · Medical Physics · doi:10.1118/1.3157111 · Cited by 44
Effective Intensity-Based 2D/3D Rigid Registration between Fluoroscopic X-Ray and CT
Knaan, D., & Joskowicz, L. (2003) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-39899-8_44 · Cited by 43
Evaluation of Intensity-Based 2D-3D Spine Image Registration Using Clinical Gold-Standard Data
Russakoff, D. B., Rohlfing, T., Ho, A., Kim, D. H., Shahidi, R., Adler, J. R., & Maurer, C. R. (2003) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-39701-4_16 · Cited by 43
“Gold standard” data for evaluation and comparison of 3D/2D registration methods
Tomaževič, D., Likar, B., & Pernuš, F. (2004) · Computer Aided Surgery · doi:10.3109/10929080500097687 · Cited by 40
Gendrin, C., Markelj, P., Pawiro, S. A., Spoerk, J., Bloch, C., Weber, C., Figl, M., Bergmann, H., Birkfellner, W., Likar, B., et al. (2011) · Medical Physics · doi:10.1118/1.3553403 · Cited by 38
Accurate and precise 2D–3D registration based on X-ray intensity
Aouadi, S., & Sarry, L. (2008) · Computer Vision and Image Understanding · doi:10.1016/j.cviu.2007.05.006 · Cited by 30
Registration of 2D x-ray images to 3D MRI by generating pseudo-CT data
van der Bom, M. J., Pluim, J. P. W., Gounis, M. J., van de Kraats, E. B., Sprinkhuizen, S. M., Timmer, J., Homan, R., & Bartels, L. W. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/4/010 · Cited by 21
Deep learning-based plane pose regression in obstetric ultrasound
Di Vece, C., Dromey, B., Vasconcelos, F., David, A. L., Peebles, D., & Stoyanov, D. (2022) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-022-02609-z · Cited by 17
Extended Capture Range of Rigid 2D/3D Registration by Estimating Riemannian Pose Gradients
Gu, W., Gao, C., Grupp, R., Fotouhi, J., & Unberath, M. (2020) · Lecture Notes in Computer Science · doi:10.1007/978-3-030-59861-7_29 · Cited by 16
Rapid patient-specific neural networks for intraoperative X-ray to volume registration
Gopalakrishnan, V., Chlorogiannis, D.-D., Abumoussa, A., Larson, A. M., Haouchine, N., Orbach, D. B., Frisken, S., Dey, N., & Golland, P. (2025) · arXiv · doi:10.48550/arxiv.2503.16309 · Cited by 13
Toward Accurate and Robust 2-D/3-D Registration of Implant Models to Single-Plane Fluoroscopy
Miao, S., Liao, R., Lucas, J., & Chefd’hotel, C. (2013) · Lecture Notes in Computer Science · doi:10.1007/978-3-642-40843-4_11 · Cited by 10
“Gold Standard” 2D/3D Registration of X-Ray to CT and MR Images
Tomaevič, D., Likar, B., & Pernuš, F. (2002) · Lecture Notes in Computer Science · doi:10.1007/3-540-45787-9_58 · Cited by 9
Metadata
- Authors
- Lemieux, L., Jagoe, R., Fish, D. R., Kitchen, N. D., & Thomas, D. G. T.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 1994-11
- Volume
- 21
- Issue
- 11
- Pages
- 1749-1760
- ISSN
- 0094-2405 (ISSN-L)
- 2473-4209
- OpenAlex
- W2000293349
- Cited by
- 222
- References
- 0
- FWCI
- 5.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.