Validation of the Fitbit Wireless Activity Tracker for Prediction of Energy Expenditure
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Objective: The purpose of this study was to examine the accuracy of the Fitbit wireless activity tracker in assessing energy expenditure (EE) for different activities. Methods: Twenty participants (10 males, 10 females) wore the Fitbit Classic wireless activity tracker on the hip and the Oxycon Mobile portable metabolic system (criterion). Participants performed walking and running trials on a treadmill and a simulated free-living activity routine. Paired t tests were used to test for differences between estimated (Fitbit) and criterion (Oxycon) kcals for each of the activities. Results: Mean bias for estimated energy expenditure for all activities was −4.5 ± 1.0 kcals/6 min (95% limits of agreement: −25.2 to 15.8 kcals/6 min). The Fitbit significantly underestimated EE for cycling, laundry, raking, treadmill (TM) 3 mph at 5% grade, ascent/descent stairs, and TM 4 mph at 5% grade, and significantly overestimated EE for carrying groceries. Energy expenditure estimated by the Fitbit was not significantly different than EE calculated from the Oxycon Mobile for 9 activities. Conclusion: The Fitbit worn on the hip significantly underestimates EE of activities. The variability in underestimation of EE for the different activities may be problematic for weight loss management applications since accurate EE estimates are important for tracking/monitoring energy deficit.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physical Activity in the United States Measured by Accelerometer
TROIANO, R. P., BERRIGAN, D., DODD, K. W., MÂSSE, L. C., TILERT, T., & MCDOWELL, M. (2008) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31815a51b3 · Cited by 7,638
Calibration of the Computer Science and Applications, Inc. accelerometer
FREEDSON, P. S., MELANSON, E., & SIRARD, J. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199805000-00021 · Cited by 3,825
Self-citationUsing Pedometers to Increase Physical Activity and Improve Health: A Systematic Review
Bravata, D. M., Smith-Spangler, C., Sundaram, V., Gienger, A. L., Lin, N., Lewis, R., Stave, C. D., Olkin, I., & Sirard, J. R. (2007) · JAMA · doi:10.1001/jama.298.19.2296 · Cited by 2,064
Staudenmayer, J., Pober, D., Crouter, S., Bassett, D., & Freedson, P. (2009) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00465.2009 · Cited by 361
Self-citationSpring, B., Schneider, K., McFadden, H. G., Vaughn, J., Kozak, A. T., Smith, M., Moller, A. C., Epstein, L. H., DeMott, A., Hedeker, D., et al. (2012) · Archives of Internal Medicine · doi:10.1001/archinternmed.2012.1044 · Cited by 208
Accelerometer output and MET values of common physical activities
KOZEY, S. L., LYDEN, K., HOWE, C. A., STAUDENMAYER, J. W., & FREEDSON, P. S. (2010) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181d479f2 · Cited by 174
Self-citation
Cited by
Systematic review of the validity and reliability of consumer-wearable activity trackers
Evenson, K. R., Goto, M. M., & Furberg, R. D. (2015) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-015-0314-1 · Cited by 1,232
Fuller, D., Colwell, E., Low, J., Orychock, K., Tobin, M. A., Simango, B., Buote, R., Van Heerden, D., Luan, H., Cullen, K., et al. (2020) · JMIR mHealth and uHealth · doi:10.2196/18694 · Cited by 715
“device energy expenditure measurements compared with reference standard criterion measures, including direct calorimetry [86,104] and indirect calorimetry [20,21,29-31,38,39,41-43,53,55,63,66,73,85,87,93,95,97,103, 105,116,117,129,130,142,143,146,148,159,165,166,177], in controlled settings.”
BackgroundMethodAccuracy of Fitbit Devices: Systematic Review and Narrative Syntheses of Quantitative Data
Feehan, L. M., Geldman, J., Sayre, E. C., Park, C., Ezzat, A. M., Yoo, J. Y., Hamilton, C. B., & Li, L. C. (2018) · JMIR mHealth and uHealth · doi:10.2196/10527 · Cited by 616
“or indirect (16 studies) calorimetry (Multimedia Appendix 3) [29,34,37,39,46,68-80].”
BackgroundSullivan, A. N., & Lachman, M. E. (2017) · Frontiers in Public Health · doi:10.3389/fpubh.2016.00289 · Cited by 458
“Research supports the usefulness of activity trackers for measuring steps, while other metrics such as EE may not be as accurate (78, 79, 123).”
BackgroundAccuracy of Heart Rate Watches: Implications for Weight Management
Wallen, M. P., Gomersall, S. R., Keating, S. E., Wisløff, U., & Coombes, J. S. (2016) · PLOS ONE · doi:10.1371/journal.pone.0154420 · Cited by 336
Behavior Change Techniques Present in Wearable Activity Trackers: A Critical Analysis
Mercer, K., Li, M., Giangregorio, L., Burns, C., & Grindrod, K. (2016) · JMIR mHealth and uHealth · doi:10.2196/mhealth.4461 · Cited by 304
“The newer-generation wearable activity trackers are also fairly accurate when compared with research-grade devices, [10] but only when used by people who do not have the atypical gaits often seen in those who experienced stroke or traumatic brain injury or have Parkinson's disease [11-16].”
Sember, V., Meh, K., Sorić, M., Starc, G., Rocha, P., & Jurak, G. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17197161 · Cited by 266
How consumer physical activity monitors could transform human physiology research
Wright, S. P., Hall Brown, T. S., Collier, S. R., & Sandberg, K. (2017) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00349.2016 · Cited by 234
Tully, M. A., McBride, C., Heron, L., & Hunter, R. F. (2014) · BMC Research Notes · doi:10.1186/1756-0500-7-952 · Cited by 172
“Much of the previous research has involved the validation of energy expenditure in controlled environments [4-7].”
Comparison of Consumer and Research Monitors under Semistructured Settings
BAI, Y., WELK, G. J., NAM, Y. H., LEE, J. A., LEE, J.-M., KIM, Y., MEIER, N. F., & DIXON, P. M. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000727 · Cited by 149
“A number of other studies have reported on the accuracy of Fitbit in estimating steps counts (1,29) and EE (13,17,22,28), but other consumer monitors are not well represented in the literature.”
BackgroundHickey, A. M., & Freedson, P. S. (2016) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2016.02.006 · Cited by 77
Self-citationDegroote, L., Hamerlinck, G., Poels, K., Maher, C., Crombez, G., De Bourdeaudhuij, I., Vandendriessche, A., Curtis, R. G., & DeSmet, A. (2020) · JMIR mhealth and uhealth · doi:10.2196/16674 · Cited by 60
“The validity to measure PA in free-living conditions has been examined for several activity trackers, such as Fitbit One, Zip, Ultra, Classic, Flex [16-18,33-38], Misfit Shine [18], and Withings Pulse [18].”
BackgroundComparison of wrist-worn and hip-worn activity monitors under free living conditions
Hargens, T. A., Deyarmin, K. N., Snyder, K. M., Mihalik, A. G., & Sharpe, L. E. (2017) · Journal of Medical Engineering & Technology · doi:10.1080/03091902.2016.1271046 · Cited by 30
Accuracy of Consumer Monitors for Estimating Energy Expenditure and Activity Type
WOODMAN, J. A., CROUTER, S. E., BASSETT, D. R., FITZHUGH, E. C., & BOYER, W. R. (2017) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001090 · Cited by 29
“To date, numerous consumer-based monitors have been validated in laboratory settings, including the Fitbit (7,15,17,18,22,25,28), Nike FuelBand (15,25,26), Jawbone Up (3,9,15,17), and Misfit Shine (3,9,17).”
BackgroundInfluentialCongruent Accuracy of Wrist-worn Activity Trackers during Controlled and Free-living Conditions
Dondzila, C. J., Lewis, C., Lopez, J. R., & Parker, T. (2018) · International Journal of Exercise Science · doi:10.70252/ubbt6886 · Cited by 16
“It is interesting to note the trend for waist-worn Fitbit devices in underestimating kcals (19, 23), with reference to wrist-worn Fitbit devices.”
Background
Metadata
- Authors
- Sasaki, J. E., Hickey, A., Mavilia, M., Tedesco, J., John, D., Keadle, S. K., & Freedson, P. S.
- Venue
- Journal of Physical Activity and Health
- Publisher
- Human Kinetics
- Published
- 2015-02
- Volume
- 12
- Issue
- 2
- Pages
- 149-154
- ISSN
- 1543-3080 (ISSN-L)
- 1543-5474
- OpenAlex
- W2125917807
- Cited by
- 116
- References
- 6
- FWCI
- 8.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.