CoChat

Extending Top-Down Mass Spectrometry to Proteins with Masses Greater Than 200 Kilodaltons

Han, Xuemei, Jin, Mi, Breuker, Kathrin, McLafferty, Fred W. · 2006 · Science

The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.

Abstract

For characterization of sequence and posttranslational modifications, molecular and fragment ion mass data from ionizing and dissociating a protein in the mass spectrometer are far more specific than are masses of peptides from the protein's digestion. We extend the ∼500-residue, ∼50-kilodalton (kD) dissociation limitation of this top-down methodology by using electrospray additives, heated vaporization, and separate noncovalent and covalent bond dissociation. This process can cleave 287 interresidue bonds in the termini of a 1314-residue (144-kD) protein, specify previously unidentified disulfide bonds between 8 of 27 cysteines in a 1714-residue (200-kD) protein, and correct sequence predictions in two proteins, one with 2153 residues (229 kD).

Overview

Integrity signals

Registry

Crossref · 10.1126/science.1128868

Cites

27 of 27 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 27 references

Research works printed but not linked: 1

  1. 10.1021/ac030174 · doi:10.1021/ac030174

Cited by

Items 101–200 of 372

Metadata

Authors
Han, X., Jin, M., Breuker, K., & McLafferty, F. W.
Affiliations
Universität Innsbruck (AT)
Corresponding author
  • Han, Xuemei
  • Jin, Mi
  • McLafferty, Fred W.
Venue
Science
Published
2006-10-06
Volume
314
Issue
5796
Pages
109-112
ISSN
  • 0036-8075 (ISSN-L)
  • 1095-9203
OpenAlex
W2048091951
Cited by
328
References
27
Citations by year
2026: 3 · 2025: 4 · 2024: 4 · 2023: 7 · 2022: 7 · 2021: 10 · 2020: 7 · 2019: 8 · 2018: 10 · 2017: 7 · 2016: 12 · 2015: 22 · 2014: 20 · 2013: 27 · 2012: 18
FWCI
15.07
Type
journal article
Language
en
Open access
closed
Locations
  • Science (publishedVersion)
  • PubMed (publishedVersion)
Funders
National Institute of General Medical Sciences (GM 16609)
Topics
  • Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
  • Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Metabolomics and Mass Spectrometry Studies
Keywords
top-down mass spectrometry, large proteins, protein sequence determination, post-translational modification, disulfide bond mapping, sequence correction
MeSH terms
Acyltransferases, Amino Acid Sequence, Chemistry, Physical, Complement C4, Cysteine, Humans, Molecular Weight, Peptide Fragments, Protein Conformation, Protein Processing, Post-Translational, Proteins, Mass Spectrometry, Protein Folding, Carbon-Nitrogen Ligases with Glutamine as Amide-N-Donor, Spectrometry, Mass, Electrospray Ionization, Proteomics, Chemical Phenomena

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.