Near-Field Optics: Microscopy, Spectroscopy, and Surface Modification Beyond the Diffraction Limit
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
The near-field optical interaction between a sharp probe and a sample of interest can be exploited to image, spectroscopically probe, or modify surfaces at a resolution (down to ∼12 nm) inaccessible by traditional far-field techniques. Many of the attractive features of conventional optics are retained, including noninvasiveness, reliability, and low cost. In addition, most optical contrast mechanisms can be extended to the near-field regime, resulting in a technique of considerable versatility. This versatility is demonstrated by several examples, such as the imaging of nanometric-scale features in mammalian tissue sections and the creation of ultrasmall, magneto-optic domains having implications for highdensity data storage. Although the technique may find uses in many diverse fields, two of the most exciting possibilities are localized optical spectroscopy of semiconductors and the fluorescence imaging of living cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Binnig, G., Quate, C. F., & Gerber, C. (1986) · Physical Review Letters · doi:10.1103/physrevlett.56.930 · Cited by 14,762
Surface Studies by Scanning Tunneling Microscopy
Binnig, G., Rohrer, H., Gerber, C., & Weibel, E. (1982) · Physical Review Letters · doi:10.1103/physrevlett.49.57 · Cited by 4,777
Cytogenetic analysis using quantitative, high-sensitivity, fluorescence hybridization.
Pinkel, D., Straume, T., & Gray, J. W. (1986) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.83.9.2934 · Cited by 3,219
Beiträge zur Theorie des Mikroskops und der mikroskopischen Wahrnehmung
Abbe, E. (1873) · Archiv für Mikroskopische Anatomie · doi:10.1007/bf02956173 · Cited by 2,724
Theory of Diffraction by Small Holes
Bethe, H. A. (1944) · Physical Review · doi:10.1103/physrev.66.163 · Cited by 2,607
Optical stethoscopy: Image recording with resolution λ/20
Pohl, D. W., Denk, W., & Lanz, M. (1984) · Applied Physics Letters · doi:10.1063/1.94865 · Cited by 2,040
Breaking the Diffraction Barrier: Optical Microscopy on a Nanometric Scale
Betzig, E., Trautman, J. K., Harris, T. D., Weiner, J. S., & Kostelak, R. L. (1991) · Science · doi:10.1126/science.251.5000.1468 · Cited by 1,534
Self-citationSuper-resolution Aperture Scanning Microscope
ASH, E. A., & NICHOLLS, G. (1972) · Nature · doi:10.1038/237510a0 · Cited by 953
XXXVIII.A suggested method for extending microscopic resolution into the ultra-microscopic region
Synge, E. H. (1928) · The London, Edinburgh, and Dublin Philosophical Magazine and Journal of Science · doi:10.1080/14786440808564615 · Cited by 843
Development of a 500 Å spatial resolution light microscope
Lewis, A., Isaacson, M., Harootunian, A., & Muray, A. (1984) · Ultramicroscopy · doi:10.1016/0304-3991(84)90201-8 · Cited by 757
Near-field magneto-optics and high density data storage
Betzig, E., Trautman, J. K., Wolfe, R., Gyorgy, E. M., Finn, P. L., Kryder, M. H., & Chang, C.-H. (1992) · Applied Physics Letters · doi:10.1063/1.108198 · Cited by 753
Self-citationNear Field Scanning Optical Microscopy (NSOM)
Betzig, E., Lewis, A., Harootunian, A., Isaacson, M., & Kratschmer, E. (1986) · Biophysical Journal · doi:10.1016/s0006-3495(86)83640-2 · Cited by 441
Self-citationSubmicroscopic pattern replication with visible light
Fischer, U. C., & Zingsheim, H. P. (1981) · Journal of Vacuum Science and Technology · doi:10.1116/1.571227 · Cited by 418
Observation of Single-Particle Plasmons by Near-Field Optical Microscopy
Fischer, U. C., & Pohl, D. (1989) · Physical Review Letters · doi:10.1103/physrevlett.62.458 · Cited by 366
A suggested method for extending microscopic resolution into ultra - microscopec resolution
Synge, E. H. (1928) · The Philosophical Magazine A Journal of Theoretical Experimental and Applied Physics · Cited by 359
The Topografiner: An Instrument for Measuring Surface Microtopography
Young, R., Ward, J., & Scire, F. (1972) · Review of Scientific Instruments · doi:10.1063/1.1685846 · Cited by 336
Interphase and Metaphase Resolution of Different Distances Within the Human Dystrophin Gene
Lawrence, J. B., Singer, R. H., & McNeil, J. A. (1990) · Science · doi:10.1126/science.2203143 · Cited by 257
Loew, L. M. (2018) · CRC Press eBooks · doi:10.1201/9781351076807 · Cited by 220
Submicroscopic contact imaging with visible light by energy transfer
Fischer, U. C., & Zingsheim, H. P. (1982) · Applied Physics Letters · doi:10.1063/1.93050 · Cited by 49
Cited by
Imaging Intracellular Fluorescent Proteins at Nanometer Resolution
Betzig, E., Patterson, G. H., Sougrat, R., Lindwasser, O. W., Olenych, S., Bonifacino, J. S., Davidson, M. W., Lippincott-Schwartz, J., & Hess, H. F. (2006) · Science · doi:10.1126/science.1127344 · Cited by 8,772
Self-citationExtraordinary optical transmission through sub-wavelength hole arrays
Ebbesen, T. W., Lezec, H. J., Ghaemi, H. F., Thio, T., & Wolff, P. A. (1998) · Nature · doi:10.1038/35570 · Cited by 7,687
Novotny, L., & Hecht, B. (2025) · Cambridge University Press eBooks · doi:10.1017/9781108781503 · Cited by 6,220
Ghosh, S. K., & Pal, T. (2007) · Chemical Reviews · doi:10.1021/cr0680282 · Cited by 2,782
Genet, C., & Ebbesen, T. W. (2007) · Nature · doi:10.1038/nature05350 · Cited by 2,007
Metadata
- Authors
- Betzig, E., & Trautman, J. K.
- Venue
- Science
- Published
- 1992-07-10
- Volume
- 257
- Issue
- 5067
- Pages
- 189-195
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2036078488
- Cited by
- 1,808
- References
- 20
- FWCI
- 75.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.