True Atomic Resolution by Atomic Force Microscopy Through Repulsive and Attractive Forces
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
The (10 1 4) cleavage plane of calcite has been investigated by atomic force microscopy in water at room temperature. True lateral atomic-scale resolution was achieved; the atomic-scale periodicities as well as the expected relative positions of the atoms within each unit cell were obtained. Along monoatomic step lines, atomic-scale kinks, representing point-like defects, were resolved. Attractive forces on the order of 10 -11 newton acting between single atomic sites on the sample and the front atoms of the tip were directly measured and provided the highest, most reliable resolution on a flat, well-ordered surface.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Binnig, G., Quate, C. F., & Gerber, C. (1986) · Physical Review Letters · doi:10.1103/physrevlett.56.930 · Cited by 14,762
Self-citationReview of Progress in Quantitative Nondestructive Evaluation: Volume 15A
(1996) · Springer eBooks · doi:10.1007/978-1-4613-0383-1 · Cited by 1,963
The general theory of van der Waals forces
Dzyaloshinskii, I. E., Lifshitz, E. M., & Pitaevskii, L. P. (1961) · Advances in Physics · doi:10.1080/00018736100101281 · Cited by 1,737
Imaging Crystals, Polymers, and Processes in Water with the Atomic Force Microscope
Drake, B., Prater, C. B., Weisenhorn, A. L., Gould, S. A. C., Albrecht, T. R., Quate, C. F., Cannell, D. S., Hansma, H. G., & Hansma, P. K. (1989) · Science · doi:10.1126/science.2928794 · Cited by 1,033
From Molecules to Cells: Imaging Soft Samples with the Atomic Force Microscope
Radmacher, M., Tillmann, R. W., Fritz, M., & Gaub, H. E. (1992) · Science · doi:10.1126/science.1411505 · Cited by 900
Forces in atomic force microscopy in air and water
Weisenhorn, A. L., Hansma, P. K., Albrecht, T. R., & Quate, C. F. (1989) · Applied Physics Letters · doi:10.1063/1.101024 · Cited by 632
Rugar, D., & Hansma, P. (1990) · Physics Today · doi:10.1063/1.881238 · Cited by 589
Atomic Resolution with Atomic Force Microscope
Binnig, G., Gerber, C., Stoll, E., Albrecht, T. R., & Quate, C. F. (1987) · Europhysics Letters (EPL) · doi:10.1209/0295-5075/3/12/006 · Cited by 559
Self-citationWeisenhorn, A. L., Maivald, P., Butt, H.-J., & Hansma, P. K. (1992) · Physical Review B · doi:10.1103/physrevb.45.11226 · Cited by 485
Atomic-Resolution Electrochemistry with the Atomic Force Microscope: Copper Deposition on Gold
Manne, S., Hansma, P. K., Massie, J., Elings, V. B., & Gewirth, A. A. (1991) · Science · doi:10.1126/science.251.4990.183 · Cited by 411
Scanning Tunneling Microscopy and Atomic Force Microscopy in Organic Chemistry
Frommer, J. (1992) · Angewandte Chemie International Edition in English · doi:10.1002/anie.199212981 · Cited by 383
Atomic force microscopy of liquid-covered surfaces: Atomic resolution images
Marti, O., Drake, B., & Hansma, P. K. (1987) · Applied Physics Letters · doi:10.1063/1.98374 · Cited by 303
Atomic-scale imaging of calcite growth and dissolution in real time
Hillner, P. E., Gratz, A. J., Manne, S., & Hansma, P. K. (1992) · Geology · doi:10.1130/0091-7613(1992)020<0359:asiocg>2.3.co;2 · Cited by 301
Quantized adhesion detected with the atomic force microscope
Hoh, J. H., Cleveland, J. P., Prater, C. B., Revel, J. P., & Hansma, P. K. (1992) · Journal of the American Chemical Society · doi:10.1021/ja00038a075 · Cited by 252
Step dynamics and spiral growth on calcite
Gratz, A. J., Hillner, P. E., & Hansma, P. K. (1993) · Geochimica et Cosmochimica Acta · doi:10.1016/0016-7037(93)90449-7 · Cited by 248
A new force sensor incorporating force-feedback control for interfacial force microscopy
Joyce, S. A., & Houston, J. E. (1991) · Review of Scientific Instruments · doi:10.1063/1.1142072 · Cited by 220
AFM images of dissolution and growth on a calcite crystal
Hillner, P. E., Manne, S., Gratz, A. J., & Hansma, P. K. (1992) · Ultramicroscopy · doi:10.1016/0304-3991(92)90454-r · Cited by 167
Effect of tip profile on atomic-force microscope images: A model study
ABRAHAM, F. F., Batra, I. P., & Çiraci, S. (1988) · Physical Review Letters · doi:10.1103/physrevlett.60.1314 · Cited by 130
Cited by
Advances in atomic force microscopy
Giessibl, F. J. (2003) · Reviews of Modern Physics · doi:10.1103/revmodphys.75.949 · Cited by 2,278
Atomic Resolution of the Silicon (111)-(7×7) Surface by Atomic Force Microscopy
Giessibl, F. J. (1995) · Science · doi:10.1126/science.267.5194.68 · Cited by 1,189
Tapping mode atomic force microscopy in liquids
Hansma, P. K., Cleveland, J. P., Radmacher, M., Walters, D. A., Hillner, P. E., Bezanilla, M., Fritz, M., Vie, D., Hansma, H. G., Prater, C. B., et al. (1994) · Applied Physics Letters · doi:10.1063/1.111795 · Cited by 875
(1996) · Handbook of Microscopy · doi:10.1002/9783527620524.ch13 · Cited by 726
de Leeuw, N. H., & Parker, S. C. (1998) · The Journal of Physical Chemistry B · doi:10.1021/jp973210f · Cited by 588
Metadata
- Authors
- Ohnesorge, F., & Binnig, G.
- Venue
- Science
- Published
- 1993-06-04
- Volume
- 260
- Issue
- 5113
- Pages
- 1451-1456
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2018691623
- Cited by
- 700
- References
- 18
- FWCI
- 34.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.