The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Abstract
Soft lithography is an alternative to silicon-based micromachining that uses replica molding of nontraditional elastomeric materials to fabricate stamps and microfluidic channels. We describe here an extension to the soft lithography paradigm, multilayer soft lithography, with which devices consisting of multiple layers may be fabricated from soft materials. We used this technique to build active microfluidic systems containing on-off valves, switching valves, and pumps entirely out of elastomer. The softness of these materials allows the device areas to be reduced by more than two orders of magnitude compared with silicon-based devices. The other advantages of soft lithography, such as rapid prototyping, ease of fabrication, and biocompatibility, are retained.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288
Xia, Y., & Whitesides, G. M. (1998) · Angewandte Chemie International Edition · doi:10.1002/(sici)1521-3773(19980316)37:5<550::aid-anie550>3.0.co;2-g · Cited by 4,285
Micromachined inertial sensors
Yazdi, N., Ayazi, F., & Najafi, K. (1998) · Proceedings of the IEEE · doi:10.1109/5.704269 · Cited by 1,823
Micromachining a Miniaturized Capillary Electrophoresis-Based Chemical Analysis System on a Chip
Harrison, D. J., Fluri, K., Seiler, K., Fan, Z., Effenhauser, C. S., & Manz, A. (1993) · Science · doi:10.1126/science.261.5123.895 · Cited by 1,800
Chemical Amplification: Continuous-Flow PCR on a Chip
Kopp, M. U., Mello, A. J. D., & Manz, A. (1998) · Science · doi:10.1126/science.280.5366.1046 · Cited by 1,212
A microfabricated fluorescence-activated cell sorter
Fu, A. Y., Spence, C., Scherer, A., Arnold, F. H., & Quake, S. R. (1999) · Nature Biotechnology · doi:10.1038/15095 · Cited by 878
Self-citationThe mechanical properties of the rubber elastic polymer polydimethylsiloxane for sensor applications
Lötters, J. C., Olthuis, W., Veltink, P. H., & Bergveld, P. (1997) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/7/3/017 · Cited by 827
Patterned Delivery of Immunoglobulins to Surfaces Using Microfluidic Networks
Delamarche, E., Bernard, A., Schmid, H., Michel, B., & Biebuyck, H. (1997) · Science · doi:10.1126/science.276.5313.779 · Cited by 678
Microfabrication Inside Capillaries Using Multiphase Laminar Flow Patterning
Kenis, P. J. A., Ismagilov, R. F., & Whitesides, G. M. (1999) · Science · doi:10.1126/science.285.5424.83 · Cited by 659
Complex Optical Surfaces Formed by Replica Molding Against Elastomeric Masters
Xia, Y., Kim, E., Zhao, X.-M., Rogers, J. A., Prentiss, M., & Whitesides, G. M. (1996) · Science · doi:10.1126/science.273.5273.347 · Cited by 643
Effenhauser, C. S., Bruin, G. J. M., Paulus, A., & Ehrat, M. (1997) · Analytical Chemistry · doi:10.1021/ac9703919 · Cited by 640
A batch-fabricated silicon accelerometer
Roylance, L. M., & Angell, J. B. (1979) · IEEE Transactions on Electron Devices · doi:10.1109/t-ed.1979.19795 · Cited by 512
High-Speed Separations on a Microchip
Jacobson, S. C., Hergenroder, R., Koutny, L. B., & Ramsey, J. M. (1994) · Analytical Chemistry · doi:10.1021/ac00079a029 · Cited by 450
Applications of dielectrophoresis in biotechnology
PETHIG, R., & MARKX, G. (1997) · Trends in Biotechnology · doi:10.1016/s0167-7799(97)01096-2 · Cited by 369
Silicon Diffused-Element Piezoresistive Diaphragms
Tufte, O. N., Chapman, P. W., & Long, D. (1962) · Journal of Applied Physics · doi:10.1063/1.1931164 · Cited by 267
Microfluidic Devices for Electrokinetically Driven Parallel and Serial Mixing
Jacobson, S. C., McKnight, T. E., & Ramsey, J. M. (1999) · Analytical Chemistry · doi:10.1021/ac990576a · Cited by 233
Duffy, D. C., Schueller, O. J. A., Brittain, S. T., & Whitesides, G. M. (1999) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/9/3/301 · Cited by 205
Shoji, S. (1998) · Topics in current chemistry · doi:10.1007/3-540-69544-3_7 · Cited by 60
Fuhr, G., & Shirley, S. G. (1995) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/5/2/006 · Cited by 39
Cited by
Microfluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379
Self-citationEngineering Flows in Small Devices: Microfluidics Toward a Lab-on-a-Chip
Stone, H. A., Stroock, A. D., & Ajdari, A. (2004) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.36.050802.122124 · Cited by 3,666
Bacterial Persistence as a Phenotypic Switch
Balaban, N. Q., Merrin, J., Chait, R., Kowalik, L., & Leibler, S. (2004) · Science · doi:10.1126/science.1099390 · Cited by 2,952
The present and future role of microfluidics in biomedical research
Sackmann, E. K., Fulton, A. L., & Beebe, D. J. (2014) · Nature · doi:10.1038/nature13118 · Cited by 2,995
Diagnostics for the Developing World: Microfluidic Paper-Based Analytical Devices
Martinez, A. W., Phillips, S. T., Whitesides, G. M., & Carrilho, E. (2010) · Analytical Chemistry · doi:10.1021/ac9013989 · Cited by 2,674
Metadata
- Authors
- Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R.
- Venue
- Science
- Published
- 2000-04-07
- Volume
- 288
- Issue
- 5463
- Pages
- 113-116
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2071311642
- Cited by
- 4,010
- References
- 19
- FWCI
- 55.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.