Reproducing human and cross-species drug toxicities using a Liver-Chip
The DOI matches its Crossref record; 52 of the 52 references it cites were found in a registry or an index.
Abstract
Nonclinical rodent and nonrodent toxicity models used to support clinical trials of candidate drugs may produce discordant results or fail to predict complications in humans, contributing to drug failures in the clinic. Here, we applied microengineered Organs-on-Chips technology to design a rat, dog, and human Liver-Chip containing species-specific primary hepatocytes interfaced with liver sinusoidal endothelial cells, with or without Kupffer cells and hepatic stellate cells, cultured under physiological fluid flow. The Liver-Chip detected diverse phenotypes of liver toxicity, including hepatocellular injury, steatosis, cholestasis, and fibrosis, and species-specific toxicities when treated with tool compounds. A multispecies Liver-Chip may provide a useful platform for prediction of liver toxicity and inform human relevance of liver toxicities detected in animal studies to better determine safety and human risk.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“the current available in vivo and in vitro DILI models have low and inadequate predictive capability.7,8”
From A High-Throughput Microphysiological Liver Chip System to Model Drug-Induced Liver Injury Using Human Liver Organoids (2024) · cites this paper as [8]
In the citing paper
“Albumin and urea production are widely accepted as functional markers for cultured hepatocytes with the goal of reaching computed production levels observed in human liver in vivo (~20–105 µg and 56–159 µg per 106 hepatocytes per day, respectively)19,26.”
From Performance assessment and economic analysis of a human Liver-Chip for predictive toxicology (2022) · cites this paper as [26]
In the citing paper
“as well as superior activity relative to hepatocytes in a 2D sandwich-assay plate configuration26.”
From Performance assessment and economic analysis of a human Liver-Chip for predictive toxicology (2022) · cites this paper as [26]
In the citing paper
“previously, the same Liver-Chip has been shown to exhibit Phase I and II functional activities that are comparable to freshly isolated human hepatocytes and 3D hepatic spheroids26,30”
From Performance assessment and economic analysis of a human Liver-Chip for predictive toxicology (2022) · cites this paper as [26]
Citations
Cites
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250
Self-citationBhatia, S. N., & Ingber, D. E. (2014) · Nature Biotechnology · doi:10.1038/nbt.2989 · Cited by 3,305
Self-citationConcordance of the toxicity of pharmaceuticals in humans and in animals
Olson, H., Betton, G., Robinson, D., Thomas, K., Monro, A., Kolaja, G., Lilly, P., Sanders, J., Sipes, G., Bracken, W., et al. (2000) · Regulatory Toxicology and Pharmacology · doi:10.1006/rtph.2000.1399 · Cited by 2,050 · cited 1×
“An analysis of 150 drugs that caused adverse events in humans found that regulatory testing in rats and dogs correctly predicted just 71% of toxicities in humans (1).”
BackgroundFrom 3D cell culture to organs-on-chips
Huh, D., Hamilton, G. A., & Ingber, D. E. (2011) · Trends in Cell Biology · doi:10.1016/j.tcb.2011.09.005 · Cited by 1,834 · cited 1×
“In addition, dense 3D constructs often suffer from limited oxygen and nutrient transport, and even when spheroid cultures include endothelial cells and Kupffer cells, they lack physiologically relevant tissue-tissue interfaces and cytoarchitecture that has been demonstrated to be a key driver of cell function (10, 42).”
BackgroundSelf-citationOrgans-on-chips at the frontiers of drug discovery
Esch, E. W., Bahinski, A., & Huh, D. (2015) · Nature Reviews Drug Discovery · doi:10.1038/nrd4539 · Cited by 1,185
Mechanisms of Acetaminophen-Induced Liver Necrosis
Hinson, J. A., Roberts, D. W., & James, L. P. (2010) · Handbook of Experimental Pharmacology · doi:10.1007/978-3-642-00663-0_12 · Cited by 1,006 · cited 1×
“APAP toxicity is caused by direct injury to hepatocytes mediated by the toxic and reactive metabolite N-acetyl-p-benzoquinone imine that depletes cellular glutathione (GSH), causing oxidative stress; it can also be detoxified by hepatocytes, resulting in formation of glucuronide and sulfate metabolites (27).”
BackgroundBjörnsson, E. S., Bergmann, O. M., Björnsson, H. K., Kvaran, R. B., & Olafsson, S. (2013) · Gastroenterology · doi:10.1053/j.gastro.2013.02.006 · Cited by 865
Human kidney proximal tubule-on-a-chip for drug transport and nephrotoxicity assessment
Jang, K.-J., Mehr, A. P., Hamilton, G. A., McPartlin, L. A., Chung, S., Suh, K.-Y., & Ingber, D. E. (2013) · Integrative Biology · doi:10.1039/c3ib40049b · Cited by 849
Self-citationMcGill, M. R., Sharpe, M. R., Williams, C. D., Taha, M., Curry, S. C., & Jaeschke, H. (2012) · Journal of Clinical Investigation · doi:10.1172/jci59755 · Cited by 763 · cited 1×
“Mitochondrial dysfunction has been identified as a hazard for APAP toxicity (47).”
BackgroundDevelopment of a primary human Small Intestine-on-a-Chip using biopsy-derived organoids
Kasendra, M., Tovaglieri, A., Sontheimer-Phelps, A., Jalili-Firoozinezhad, S., Bein, A., Chalkiadaki, A., Scholl, W., Zhang, C., Rickner, H., Richmond, C. A., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-21201-7 · Cited by 754
Self-citation
Research works printed but not linked: 3
- Food and Drug Administration Drug Approval Package : Tracleer (Bosentan) (Food and Drug Administration 2001) pp. 21–290.
- Institute of Medicine (U.S) Committee to Review the Fialuridine (FIAU/FIAC) Clinical Trials in Review of the Fialuridine (FIAU) Clinical Trials F. J. Manning M. N. Swartz Eds. (National Academy Press 1995) 269 pp.
- Food and Drug Administration The Food and Drug Administration Predictive Toxicology Roadmap and Its Implementation; Public Hearing; Request for Comments (Office of the Federal Register National Archives and Records Administration 2018) vol. 83 pp. 30595–30598.
Cited by
Items 201–300 of 521
A pumpless liver-on-a-chip for drug hepatotoxicity analysis
Jiao, D., Xie, L., & Xing, W. (2024) · The Analyst · doi:10.1039/d4an00602j · Cited by 22
Microtechnology-based in vitro models: Mimicking liver function and pathophysiology
Lee, S. Y., Kim, D., Sung, J. H., & Sung, J. H. (2021) · APL Bioengineering · doi:10.1063/5.0061896 · Cited by 24
Microphysiological systems to advance human pathophysiology and translational medicine
Harriot, A. D., Ward, C. W., & Kim, D. (2024) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00087.2024 · Cited by 23
Rothbauer, M., Strauss, J., Reihs, E. I., Heidenberger, J., Alphonsus, J., Gowers, S. A. N., Chen, Y., McLeod, J., Toegel, S., Ertl, P., et al. (2024) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2024.137123 · Cited by 24
Hepatic organoids as a platform for liver disease modeling and the development of novel therapies
Luce, E., Messina, A., & Duclos‐Vallée, J. (2025) · Clinics and Research in Hepatology and Gastroenterology · doi:10.1016/j.clinre.2025.102647 · Cited by 24
Hepatocyte cultures: From collagen gel sandwiches to microfluidic devices with integrated biosensors
de Hoyos‐Vega, J. M., Hong, H. J., Stybayeva, G., & Revzin, A. (2021) · APL Bioengineering · doi:10.1063/5.0058798 · Cited by 22
Lacombe, J., Soldevila, M., & Zenhausern, F. (2022) · Progress in molecular biology and translational science · doi:10.1016/bs.pmbts.2021.07.019 · Cited by 26
Biomimetic epithelium/endothelium on chips
Lin, L., Wang, X., Niu, M., Wu, Q., Wang, H., Zu, Y., & Wang, W. (2022) · Engineered Regeneration · doi:10.1016/j.engreg.2022.05.001 · Cited by 25
Integrating Liver-Chip data into pharmaceutical decision-making processes
Levner, D., & Ewart, L. C. (2023) · Expert Opinion on Drug Discovery · doi:10.1080/17460441.2023.2255127 · Cited by 20
“Characterization of the Liver-Chip has shown it to be a reproducible and functional model of human liver tissue [18,25,31], and prior studies have specifically demonstrated its ability to capture the toxicity of drugs that have led to cholestasis, steatosis, and fibrosis [18].”
BackgroundResultSelf-citationFrom cells to organs: progress and potential in cartilaginous organoids research
Wang, X., Liu, N., Zhang, H., Yin, Z., & Zha, Z.-G. (2023) · Journal of Translational Medicine · doi:10.1186/s12967-023-04591-9 · Cited by 22
“By replicating perfusion, mechanical forces, and other essential parameters for tissue and organ physiology, microfluidic systems enable a more comprehensive understanding of specific cellular responses and the fluidic and mechanical aspects of the cellular microenvironment [141].”
BackgroundKennedy, J. I., Davies, S. P., Hewett, P. W., Wilkinson, A. L., Oo, Y. H., Lu, W., Haj, A. J. E., & Shetty, S. (2024) · Frontiers in Cell and Developmental Biology · doi:10.3389/fcell.2024.1359451 · Cited by 21
Current and potential future applications of human stem cell models in drug development
Donowitz, M., Turner, J. R., Verkman, A. S., & Zachos, N. C. (2020) · Journal of Clinical Investigation · doi:10.1172/jci138645 · Cited by 22
Moon, H., Surianarayanan, N., Singh, T., & Han, B. (2023) · Biomicrofluidics · doi:10.1063/5.0179444 · Cited by 23
A Microfluidic Organ-On-A-Chip: Into the Next Decade of Bone Tissue Engineering Applied in Dentistry
Syahruddin, M. H., Anggraeni, R., & Ana, I. D. (2023) · Future Science OA · doi:10.2144/fsoa-2023-0061 · Cited by 20
A method to generate perfusable physiologic-like vascular channels within a liver-on-chip model
Ferrari, E., Monti, E. J., Cerutti, C., Visone, R., Occhetta, P., Griffith, L. G., & Rasponi, M. (2023) · Biomicrofluidics · doi:10.1063/5.0170606 · Cited by 21
Perry, A., Hadad, N., Chatterjee, E., Ramos, M. J., Farber‐Eger, E. H., Roshani, R., Stolze, L. K., Betti, M. J., Zhao, S., Huang, S., et al. (2024) · Cell Reports Medicine · doi:10.1016/j.xcrm.2024.101871 · Cited by 23
HepaChip-MP – a twenty-four chamber microplate for a continuously perfused liver coculture model
Busche, M., Tomilova, O., Schütte, J., Werner, S., Beer, M., Groll, N., Hagmeyer, B., Pawlak, M., Jones, P. D., Schmees, C., et al. (2020) · Lab on a Chip · doi:10.1039/d0lc00357c · Cited by 20
Microengineered systems with iPSC-derived cardiac and hepatic cells to evaluate drug adverse effects
Dame, K., & Ribeiro, A. J. S. (2020) · Experimental Biology and Medicine · doi:10.1177/1535370220959598 · Cited by 24
Liver organoids: From fabrication to application in liver diseases
Liu, Q., Zeng, A., Liu, Z., Wu, C., & Song, L. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2022.956244 · Cited by 19
“As the toxicity of certain drugs, such as the proprietary compound JNJ-2, can associate with significant species variability, liver organoids provide a considerably more accurate tool for drug toxicity testing than animal models (Jang et al., 2019).”
Opportunities for Microphysiological Systems in Toxicity Testing of New Drug Modalities
Maulana, T. I., Wevers, N. R., Kristoforus, T., Chandler, M. R., Lanz, H. L., Joore, J., Vulto, P., Villenave, R., Kustermann, S., Loskill, P., et al. (2024) · The Annual Review of Pharmacology and Toxicology · doi:10.1146/annurev-pharmtox-061724-080621 · Cited by 24
Liu, J., Wu, G., Wu, D., Wu, L., Sun, C., Zhang, W., Du, Q., Lu, Q., Hu, W., Meng, H., et al. (2025) · Lab on a Chip · doi:10.1039/d4lc00902a · Cited by 20
Integrated Patient Digital and Biomimetic Twins for Precision Medicine: A Perspective
Miedel, M. T., Schurdak, M. E., Stern, A. M., Soto–Gutiérrez, A., Strobl, E. V., Behari, J., & Taylor, D. L. (2025) · Seminars in Liver Disease · doi:10.1055/a-2649-1560 · Cited by 23
New approach methodologies (NAMs) for drug-induced liver injury (DILI): Where are we now?
Shrimali, S., Chen, M., Li, D., & Tong, W. (2025) · Drug Discovery Today · doi:10.1016/j.drudis.2025.104452 · Cited by 20
Atrial-specific hiPSC-derived cardiomyocytes in drug discovery and disease modeling
Gharanei, M., Shafaattalab, S., Sangha, S. S., Gunawan, M. G., Laksman, Z., Hove‐Madsen, L., & Tibbits, G. F. (2021) · Methods · doi:10.1016/j.ymeth.2021.06.009 · Cited by 21
Analytical and biomedical applications of microfluidics in traditional Chinese medicine research
Shen, P., Jia, Y., Shi, S., Sun, J. T., & Han, X. (2022) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2022.116851 · Cited by 18
The role of the gut microbiome in graft fibrosis after pediatric liver transplantation
Qin, T., Fu, J., & Verkade, H. J. (2020) · Human Genetics · doi:10.1007/s00439-020-02221-8 · Cited by 20
Lung on a Chip Development from Off-Stoichiometry Thiol–Ene Polymer
Rimša, R., Galvanovskis, A., Plūme, J., Rūmnieks, F., Grindulis, K., Paidere, G., Erentraute, S., Mozoļevskis, G., & Ābols, A. (2021) · Micromachines · doi:10.3390/mi12050546 · Cited by 19
Lipid Hormones at the Intersection of Metabolic Imbalances and Endocrine Disorders
Dobre, M.-Z., Vîrgolici, B., & Cioarca-Nedelcu, R. (2025) · Current Issues in Molecular Biology · doi:10.3390/cimb47070565 · Cited by 23
“Recent studies have successfully modeled steatosis, inflammation, and fibrogenesis on liver-on-chip platforms, demonstrating these systems’ potential for drug screening, toxicity testing, and biomarker discovery in MASLD research [160].”
Advanced Biomanufacturing Technologies for Micro-physiological Systems
Kim, M. K., Yoon, J., Kim, D., Kim, J., Kim, J.-S., Go, G., Song, J., Son, S., Park, K., Lee, J., et al. (2025) · International Journal of Precision Engineering and Manufacturing · doi:10.1007/s12541-025-01330-6 · Cited by 16
Lei, Y., Zhang, Y., Zhou, L., Zhou, Z., Rothbauer, M., Bai, L., Xu, J., Xie, D., Mobasheri, A., Zhang, X., et al. (2025) · Journal of Orthopaedic Translation · doi:10.1016/j.jot.2025.10.013 · Cited by 32
“…performance to ensure that they reliably predict human responses and generate consistent, reproducible data [130], as recently demonstrated by multispecies liver-chip assays that reproduced human-specific DILI at clinically relevant exposures and outperformed corresponding animal studies [131].”
Advances and applications of organ-on-a-chip technology
Kong, J. S., Kim, J., Jang, J., & Cho, D.-W. (2026) · Cell Reports Methods · doi:10.1016/j.crmeth.2026.101361 · Cited by 20
“91 The optimization of cell ratios, spatial organization, and culture conditions for co-culture systems presents ongoing challenges.”
Tamargo-Rubio, I., Simpson, A. B., Hoogerland, J. A., & Fu, J. (2023) · Frontiers in Pharmacology · doi:10.3389/fphar.2023.1223108 · Cited by 22
“, 2022), including human-specific drug toxicity (Jang et al., 2019).”
Zeng, Y.-L., Du, Y., Xu, X., Wang, Y., Yu, S., Liu, T., Luo, S., Xiang, X., Liu, W., Chen, Y.-C., et al. (2023) · Nano Today · doi:10.1016/j.nantod.2023.101947 · Cited by 19
National reflection on organs-on-chip for drug development: New regulatory challenges
Teixeira, S. G., Houeto, P., Gattacceca, F., Petitcollot, N., Debruyne, D., Guerbet, M., Guillemain, J., Fabre, I., Louin, G., & Salomon, V. (2023) · Toxicology Letters · doi:10.1016/j.toxlet.2023.09.011 · Cited by 22
On-microparticle construction of endothelialized liver microtissues for drug testing
Wu, Z., Zheng, Y., Lin, J., Li, Y., Li, Y., Wang, X., & Lin, L. (2023) · Chemical Engineering Journal · doi:10.1016/j.cej.2023.148403 · Cited by 18
Integrated Array Chip for High-Throughput Screening of Species Differences in Metabolism
Ai, X., Zhao, L., Lu, Y., Hou, Y., Lv, T., Jiang, Y., Tu, P., & Guo, X. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c01590 · Cited by 17
Proceedings of a workshop to address animal methods bias in scientific publishing
Krebs, C. E., Camp, C., Constantino, H., Courtot, L., Kavanagh, O., Leite, S. B., Madden, J., Paini, A., Poojary, B., Tripodi, I. J., et al. (2022) · ALTEX · doi:10.14573/altex.2210211 · Cited by 17
“…et al., 2020), bone marrow (Chou et al., 2020), and other tissues and organs, as well as for vaccine testing (Goyal et al., 2022) and drug toxicology (Jang et al., 2019), where they are identifying drug toxicities to humans that had not been detected in animals (Ewart et al., 2021).”
BackgroundScoon, W. A., Mâncio-Silva, L., Suder, E. L., Villacorta-Martín, C., Lindstrom-Vautrin, J., Bernbaum, J. G., Mazur, S., Johnson, R. F., Olejnik, J., Flores, E. Y., et al. (2022) · Stem Cell Reports · doi:10.1016/j.stemcr.2022.08.003 · Cited by 17
Otumala, A. E., Hellen, D. J., Luna, C. A., Delgado, P., Dissanayaka, A., Ugwumadu, C., Oshinowo, O. T., Islam, M. M., Shen, L., Karpen, S. J., et al. (2023) · Lab on a Chip · doi:10.1039/d2lc00940d · Cited by 17
Advancement of organ-on-chip towards next generation medical technology
Singh, G., Mishra, A., Mathur, A. K., Shastri, S., Nizam, A., Rizwan, A., Dadial, A. S., Firdous, A., & Hassan, H. (2024) · Biosensors and Bioelectronics X · doi:10.1016/j.biosx.2024.100480 · Cited by 22
Establishment of advanced tumor organoids with emerging innovative technologies
Mao, Y., & Hu, H. (2024) · Cancer Letters · doi:10.1016/j.canlet.2024.217122 · Cited by 20
Cipriano, M., Pinheiro, P. F., Sequeira, C. O., Rodrigues, J. S., Oliveira, N., Antunes, A. M. M., Castro, M., Marques, M. M., Pereira, S. A., & Miranda, J. P. (2020) · International Journal of Molecular Sciences · doi:10.3390/ijms21113998 · Cited by 18
“However, until today, few authors performed a thorough study on drug metabolism in such devices [26,27].”
BackgroundResultSaydmohammed, M., Jha, A., Mahajan, V., Gavlock, D. C., Shun, T. Y., DeBiasio, R., Lefever, D. E., Li, X., Reese, C. E., Kershaw, E. E., et al. (2021) · Experimental Biology and Medicine · doi:10.1177/15353702211009228 · Cited by 20
Latest impact of engineered human liver platforms on drug development
Monckton, C. P., Brown, G. E., & Khetani, S. R. (2021) · APL Bioengineering · doi:10.1063/5.0051765 · Cited by 18
Irrechukwu, O., Yeager, R., David, R. M., Ekert, J., Saravanakumar, A., & Choi, C. K. (2023) · ALTEX · doi:10.14573/altex.2204071 · Cited by 25
“In these models, the cells were exposed to higher concentrations of fatty acids (oleic and palmitic acids), resulting in lipid accumulation in the hepatocytes (Jang et al., 2019; Kostrzewski et al., 2017; Kozyra et al., 2018).”
BackgroundMultispecies liver-on-a-chip for improved drug toxicity testing
Dickson, I. (2019) · Nature Reviews Gastroenterology & Hepatology · doi:10.1038/s41575-019-0244-5 · Cited by 16
Abdalkader, R., Chaleckis, R., Wheelock, C. E., & Kamei, K. (2021) · Experimental Eye Research · doi:10.1016/j.exer.2021.108646 · Cited by 16
“Many OoC platforms developed to study the metabolism and transport mechanisms use optical or fluorescent assays [e.g., 3-(4,5-dimethylthial-2-yl)-2,5-diphenyltetrazalium bromide (MTT)] and lucifer yellow (Bovard et al., 2018; Jang et al., 2019; McAleer et al., 2019).”
Lymphoid follicle formation and human vaccination responses recapitulated in an organ-on-a-chipPreprint
Goyal, G., Prabhala, P., Mahajan, G., Bausk, B., Gilboa, T., Xie, L., Zhai, Y., Lazarovits, R., Mansour, A., Kim, M. S., et al. (2019) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/806505 · Cited by 16
Self-citationHollow Microfiber Assembly‐Based Endocrine Pancreas‐on‐a‐Chip for Sugar Substitute Evaluation
Tian, L., Shi, J., Li, W., Zhang, Y., & Gao, X. (2023) · Advanced Healthcare Materials · doi:10.1002/adhm.202302104 · Cited by 17
Royse, M. K., Fowler, M., Mai, A. K., He, Y., Durante, M. R., Buist, N., Procopio, A. T., Xu, J., & Veiseh, O. (2024) · Biomaterials Science · doi:10.1039/d4bm00663a · Cited by 17
Tumoroids, a valid preclinical screening platform for monitoring cancer angiogenesis
Abbasi‐Malati, Z., Khanicheragh, P., Narmi, M. T., Mardi, N., Khosrowshahi, N. D., Hiradfar, A., Rezabakhsh, A., Sadeghsoltani, F., Rashidi, S., Chegeni, S. A., et al. (2024) · Stem Cell Research & Therapy · doi:10.1186/s13287-024-03880-4 · Cited by 17
Samantasinghar, A., Sunildutt, N., Ahmed, F., Memon, F. H., Kang, C.-U., & Choi, K. H. (2025) · ACS Omega · doi:10.1021/acsomega.4c11227 · Cited by 20
Human organ chips for regenerative pharmacology
Goyal, G., Belgur, C., & Ingber, D. E. (2023) · Pharmacology Research & Perspectives · doi:10.1002/prp2.1159 · Cited by 15
“…of healthy and diseased human Organ Chips including models of lung small airway, 2 intestine, 3 liver, 4 kidney, 5,6 skin, blood–brain barrier, 7,8 female genital tract, 9,10 bone marrow, 11,12 and lymph node, 13 as well as non-human primate (NHP), dog, rat, 14 and mouse 15,16 Organ Chip models.”
BackgroundSelf-citationSano, E., Deguchi, S., Matsuoka, N., Tsuda, M., Wang, M., Kosugi, K., Mori, C., Yagi, K., Wada, A., Yamasaki, S., et al. (2021) · ACS Omega · doi:10.1021/acsomega.1c03719 · Cited by 15
Myszczyszyn, A., Muench, A., Lehmann, V., Sinnige, T., van Steenbeek, F. G., Bouwmeester, M., Samsom, R.-A., Keuper-Navis, M., van der Made, T. K., Kogan, D., et al. (2025) · Biofabrication · doi:10.1088/1758-5090/adc3ce · Cited by 14
“Current liver-on-a-chip models do not meet the 3Rs’ principles [3], as they utilize fetal bovine serum-rich media and animal-derived ECM components such as Matrigel from mouse sarcoma, rat tail collagen I and bovine fibronectin [9].”
Goralski, T. D. P., Jenkins, C. C., Angelini, D. J., Horsmon, J. R., Dhummakupt, E. S., Rizzo, G. M., Simmons, B. L., Liem, A. T., Roth, P. A., Karavis, M. A., et al. (2023) · PLoS ONE · doi:10.1371/journal.pone.0280883 · Cited by 14
“Four different cell types of hepatic origin are maintained in this model They consist of hepatocytes in the top channel and a layer composed of the nonparenchymal (NPC) Kupffer cells, human stellate cells (HSCs), and liver sinusoidal endothelial cells (LSECs) in the bottom channel [5].”
BackgroundMethodHigh-throughput cell spheroid production and assembly analysis by microfluidics and deep learning
Trossbach, M., Åkerlund, E., Langer, K., Seashore-Ludlow, B. A., & Joensson, H. N. (2023) · SLAS TECHNOLOGY · doi:10.1016/j.slast.2023.03.003 · Cited by 15
Sun, S., Xue, X., & Fu, J. (2023) · Current Opinion in Genetics & Development · doi:10.1016/j.gde.2023.102097 · Cited by 15
Nassar, A., Kodi, T., Satarker, S., Gurram, P. C., Fayaz, S. M., & Nampoothiri, M. (2023) · Gene · doi:10.1016/j.gene.2023.147898 · Cited by 15
Three-Dimensional Tumor Models to Study Cancer Stemness-Mediated Drug Resistance
Lamichhane, A., & Tavana, H. (2024) · Cellular and Molecular Bioengineering · doi:10.1007/s12195-024-00798-y · Cited by 18
“Microfluidic organ-on-chip models have been established for a variety of organs, including lung [112, 113], liver [114], kidney [115], and heart [116].”
BackgroundModelling the innate immune system in microphysiological systems
Rupar, M. J., Hanson, H. M., Rogers, S., Botlick, B. L., Trimmer, S. J., & Hickman, J. J. (2024) · Lab on a Chip · doi:10.1039/d3lc00812f · Cited by 17
Soragni, C., Rabussier, G., Lanz, H. L., Bircsak, K. M., Windt, L. J. D., Trietsch, S. J., Murdoch, C. E., & Ng, C. P. (2022) · Redox Biology · doi:10.1016/j.redox.2022.102488 · Cited by 20
“High concentration was expected as generally used with organ-on-a-chip models to induce ROS [29,30,52,53].”
BackgroundChallenges in the Development and Application of Organ-on-Chips for Intranasal Drug Delivery Studies
Khan, M. U., Cai, X., Shen, Z., Mekonnen, T. T., Kourmatzis, A., Cheng, S., & Gholizadeh, H. (2023) · Pharmaceutics · doi:10.3390/pharmaceutics15051557 · Cited by 14
Human Cell-Based in vitro Phenotypic Profiling for Drug Safety-Related Attrition
Berg, E. L. (2019) · Frontiers in Big Data · doi:10.3389/fdata.2019.00047 · Cited by 14
“Despite this, identified mechanisms reveal critical differences between humans and animals commonly employed in safety tests (Jang et al., 2019).”
BackgroundFerrari, I., Limiti, E., Giannitelli, S. M., Trombetta, M., Rainer, A., D’Amelio, M., Barbera, L. L., & Gori, M. (2025) · International Journal of Molecular Sciences · doi:10.3390/ijms26199478 · Cited by 15
“…by Emulate Inc. for predicting species-specific toxicities of hepatotoxic compounds, and for a toxicology screening that compared outcomes from hepatic organoids and mouse models with liver-on-chips, to better evaluate risk assessment and human relevance of microfluidic liver models [84,85].”
Shrimali, S., Li, D., Knox, B., Tong, W., & Ning, B. (2025) · Drug Metabolism and Disposition · doi:10.1016/j.dmd.2025.100187 · Cited by 15
Long, Y., Liang, K., Niu, Y., Wang, R., Liu, R., Zhang, Y., Ao, Y., Jin, Y., Wu, Z., Wu, B., et al. (2025) · Science Advances · doi:10.1126/sciadv.adu7596 · Cited by 13
“Many 3D models developed in recent years, which mainly mimic the structure of the in vivo microenvironment ( 45 – 47 ), are unable to accurately replicate both the hemodynamic and matrix environments of cirrhosis and to reproduce pathological features such as modeling angiogenesis in early fibrosis…”
Alternatives to animal testing to assess MASH drugs and hepatotoxicity
Brenner, D. A. (2023) · Hepatology · doi:10.1097/hep.0000000000000669 · Cited by 15
Qu, B., Mu, Q., Bi, H., Chen, Y., Wang, Q., Ma, X., & Lu, L. (2024) · Frontiers in Cell and Developmental Biology · doi:10.3389/fcell.2024.1433111 · Cited by 14
“Recently, micro fl uidic organoid-on-a-chip models have been developed for modeling various organs in vitro , including the lungs (Shrestha et al., 2020), liver (Jang et al., 2019), kidneys (Wilmer et al., 2016), and heart (Abulaiti et al., 2020).”
Schneider, R. S., Nieves, E. B., Aggarwal, B., Bowles, A. C., Stevens, H. Y., Kippner, L. E., Boden, S. D., Mautner, K., Drissi, H., Roy, K., et al. (2025) · Nature Communications · doi:10.1038/s41467-025-60158-w · Cited by 15
“…2D assay data, there has been a notable shift towards development and valida-tionof3Dmodels,includingorganoidmodels 12 – 15 and ‘ organ-on-a-chip ’ microphysiological systems 16,17 to better emulate the complexity of in vivo environments and enhance predictive accuracy in clinical decision-making.”
Self-citationDirecting Cholangiocyte Morphogenesis in Natural Biomaterial Scaffolds
Smith, Q., Bays, J., Li, L., Shareef, H., Chen, C. S., & Bhatia, S. N. (2021) · Advanced Science · doi:10.1002/advs.202102698 · Cited by 16
Baka, Z., Stiefel, M., Figarol, A., Godier, C., Mallick, A., Joubert, O., Ashammakhi, N. A., Gaffet, É., & Alem, H. (2022) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ac8259 · Cited by 15
“In this context, OOCs have been shown to accurately reproduce clinically observed vascular [145], hepatic [146] and renal [147] side effects of new molecules developed by pharmaceutical companies.”
Microphysiological Models for Mechanistic-Based Prediction of Idiosyncratic DILI
Stern, S., Wang, H., & Sadrieh, N. K. (2023) · Cells · doi:10.3390/cells12111476 · Cited by 14
Recent Advances in Drug Discovery Toxicology
Tang, B., & More, V. R. (2023) · International Journal of Toxicology · doi:10.1177/10915818231189659 · Cited by 15
Alb, M., Reiche, K., Rade, M., Sewald, K., Loskill, P., Cipriano, M., Maulana, T. I., van der Meer, A. D., Weener, H. J., Clerbaux, L., et al. (2024) · Journal of Immunotoxicology · doi:10.1080/1547691x.2024.2345158 · Cited by 15
“…(Gholizadeh et al. 2022; Shroff et al. 2022; Maass et al. 2019; McAleer et al. 2019) or immune cell recruitment (Kerns et al. 2021; Cipriano et al. 2022; Rogal et al. 2022) nor in animal models (Jang et al. 2019; Richardson et al. 2020; Koning et al. 2021; Bjornson-Hooper et al. 2022; Ingber 2022).”
Manatakis, D. V., VanDevender, A. P., & Manolakos, E. S. (2020) · Bioinformatics · doi:10.1093/bioinformatics/btaa654 · Cited by 13
Breaking down the barriers to animal-free research
Hope, L., & Bailey, J. (2025) · Alternatives to Laboratory Animals · doi:10.1177/02611929251349465 · Cited by 12
Reconstitution of human tissue barrier function for precision and personalized medicine
Kim, J., Yoon, T., Lee, S. W., Kim, P. J., & Kim, Y. (2024) · Lab on a Chip · doi:10.1039/d4lc00104d · Cited by 16
Organ‐on‐Chip: The Future of Nutrition Research in a One Health World
Cassotta, M., Elexpuru-Zabaleta, M., Cano, S. S., Díaz, Y. A., Giampieri, F., Xiaobo, Z., Zhang, D., Grosso, G., & Battino, M. A. (2025) · Food Frontiers · doi:10.1002/fft2.70000 · Cited by 12
Pérez‐Calixto, M., Peto‐Gutiérrez, C., Shapiro, A., Huerta, L., Hautefeuille, M., Macías‐Silva, M., Pérez‐Calixto, D., & Vázquez‐Victorio, G. (2025) · Advanced Healthcare Materials · doi:10.1002/adhm.202404686 · Cited by 12
Maschmeyer, I., & Kakava, S. (2020) · Advances in biochemical engineering, biotechnology · doi:10.1007/10_2020_135 · Cited by 16
Prenatal Development and Function of Human Mononuclear Phagocytes
Miah, M., Goh, I., & Haniffa, M. A. (2021) · Frontiers in Cell and Developmental Biology · doi:10.3389/fcell.2021.649937 · Cited by 13
Whiteford, J. R., Arokiasamy, S., Thompson, C. L., & Dufton, N. (2022) · In vitro models · doi:10.1007/s44164-022-00034-9 · Cited by 14
“) in line with manufacturer’s protocols[10, 17].”
BackgroundHuman Liver Organoid Models for Assessment of Drug Toxicity at the Preclinical Stage
Karabicici, M., Akbari, S., Ertem, Ö., Gümüştekin, M., & Erdal, E. (2023) · Endocrine Metabolic & Immune Disorders - Drug Targets · doi:10.2174/1871530323666230411100121 · Cited by 12
Harnessing the power of microphysiological systems for COVID-19 research
Kleinstreuer, N., & Holmes, A. M. (2021) · Drug Discovery Today · doi:10.1016/j.drudis.2021.06.020 · Cited by 12
Standard: human liver-on-a-chip
Liu, H., Zhang, X., Wang, Y., Zhang, M., Wang, P., Shang, J., Li, Z., Gong, L., Xie, X., Liu, D., et al. (2025) · Cell Regeneration · doi:10.1186/s13619-025-00226-0 · Cited by 12
Constructing biomimetic microenvironments for liver regeneration
(2025) · doi:10.1186/s12951-025-03729-9 · Cited by 11
Current Research Trends in the Application of In Vitro Three-Dimensional Models of Liver Cells
Yun, C., Kim, S. H., & Jung, Y. (2022) · Pharmaceutics · doi:10.3390/pharmaceutics15010054 · Cited by 15
“Therefore, the accurate identification of the specific toxicity of a species and identifying DILIs in human-relevant animals have become goals for the use of animal models [111].”
Beyond the hype and toward application: liver complex in vitro models in preclinical drug safety
Jadalannagari, S., & Ewart, L. C. (2024) · Expert Opinion on Drug Metabolism & Toxicology · doi:10.1080/17425255.2024.2328794 · Cited by 15
“In the short term, researchers working with liver CIVMs focus measurement of albumin or ALT and AST, but urea is a good marker of mitochondrial function and has been measured in liver CIVMs [45,62,97] while miR122, which signals hepatocyte damage, has also been measured in liver CIVMs [98,99].”
Self-citationRevolutionizing renal research: The future of kidney-on-a-chip in biotechnology
Nishimura, Y. (2024) · Regenerative Therapy · doi:10.1016/j.reth.2024.06.006 · Cited by 15
Wang, W., Lian, H., Liang, Y., Ye, Y., Tam, P. K. H., & Chen, Y. (2024) · Cells · doi:10.3390/cells13231997 · Cited by 13
“However, a major drawback of these mice is that the immunological and pathological characteristics they exhibit have limited correlation with clinical practice [168].”
Developments and Applications of Liver-on-a-Chip Technology—Current Status and Future Prospects
Mugaanyi, J., Huang, J., Fang, J., Musinguzi, A., Lu, C., & Chen, Z. (2025) · Biomedicines · doi:10.3390/biomedicines13061272 · Cited by 14
“LiOC systems have also been shown to model diverse mechanisms of toxicity and to measure relevant clinical biomarkers, outperforming animal models in predicting human responses to drugs [104,105].”
Lab-on-a-Chip and Microfluidics Technologies for Nano Drug Delivery
Guo, B., Zhao, Y., & Zhang, X. (2026) · Bioengineering · doi:10.3390/bioengineering13030363 · Cited by 12
“A liver-on-chip model developed by Jang et al. [148], consisting of rat, dog, or human hepatocytes; endothelial cells; Kupffer cells; and stellate cells, confirmed the mechanism of action of several known hepatotoxic drugs and experimental compounds.”
Zhong, Y., Yu, J. S., Wang, X., Binas, B., & Yoo, H. H. (2021) · The FASEB Journal · doi:10.1096/fj.202001629rr · Cited by 13
A proof-of-concept study poised to remodel the drug development process
Nahle, Z. A. (2022) · Frontiers in Medical Technology · doi:10.3389/fmedt.2022.1053588 · Cited by 12
Organ mimicking technologies and their applications in drug discovery
Qu, Y., Ye, J., Lin, B., Luo, Y., & Zhang, X. (2023) · Intelligent Pharmacy · doi:10.1016/j.ipha.2023.05.003 · Cited by 14
Bai, H., Olson, K. N. P., Pan, M., Marshall, T., Singh, H., Ma, J., Gilbride, P., Yuan, Y., McCormack, J., Si, L., et al. (2023) · Advanced Science · doi:10.1002/advs.202304332 · Cited by 14
“This is consistent with previous publications suggesting that dynamic 3D 268 culture improves hepatocyte long-term viability and metabolic competence (25-27).”
ResultDeng, Q., Qu, Y., Luo, Y., & Zhang, X. (2025) · Journal of Ethnopharmacology · doi:10.1016/j.jep.2025.119633 · Cited by 11
Novel emerging cell and organoid systems for the study of drug metabolism and toxicity in humans
Gracey, E. G., & Lampe, J. N. (2025) · Drug Metabolism and Disposition · doi:10.1016/j.dmd.2025.100188 · Cited by 11
Nah, H., Michell, A. R., Rogy, K. M., Lally, O. J., & Khetani, S. R. (2025) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2025.115737 · Cited by 11
Metadata
- Authors
- Jang, K.-J., Otieno, M. A., Ronxhi, J., Lim, H.-K., Ewart, L., Kodella, K. R., Petropolis, D. B., Kulkarni, G., Rubins, J. E., Conegliano, D., Nawroth, J., Simic, D., Lam, W., Singer, M., Barale, E., Singh, B., Sonee, M., Streeter, A. J., Manthey, C., Jones, B., Srivastava, A., Andersson, L. C., Williams, D., Park, H., Barrile, R., Sliz, J., Herland, A., Haney, S., Karalis, K., Ingber, D. E., & Hamilton, G. A.
- Affiliations
- Emulate (United States) (US)
- Janssen Pharmaceutical Research and Development, Nonclinical Safety, 1400 Welsh and McKean Road, Spring House, PA 19477, USA.
- Janssen Pharmaceutical Research and Development, Drug Metabolism and Pharmacokinetics, 1400 Welsh and McKean Road, Spring House, PA 19477, USA.
- AstraZeneca (United Kingdom) (GB)
- Emulate Inc., 27 Drydock Avenue, Boston, MA 02210, USA.
- Janssen Pharmaceutical Research and Development, IPD Biology, 1400 Welsh and McKean Road, Spring House, PA 19477, USA.
- AstraZeneca (Sweden) (SE)
- Harvard University (US)
- Boston Children's Hospital (US)
- Corresponding author
- Otieno, Monicah A.
- Hamilton, Geraldine A.
- ORCID
- Jang, Kyung-Jin
- Otieno, Monicah A.
- Ronxhi, Janey
- Lim, Heng-Keang
- Ewart, Lorna
- Kodella, Konstantia R.
- Petropolis, Debora B.
- Kulkarni, Gauri
- Rubins, Jonathan E.
- Conegliano, David
- Nawroth, Janna
- Lam, Wing
- Singer, Monica
- Barale, Erio
- Singh, Bhanu
- Sonee, Manisha
- Streeter, Anthony J.
- Manthey, Carl
- Srivastava, Abhishek
- Andersson, Linda C.
- Williams, Dominic
- Park, Hyoungshin
- Barrile, Riccardo
- Sliz, Josiah
- Herland, Anna
- Karalis, Katia
- Ingber, Donald E.
- Hamilton, Geraldine A.
- Venue
- Science Translational Medicine
- Published
- 2019-11-06
- Volume
- 11
- Issue
- 517
- ISSN
- 1946-6234 (ISSN-L)
- 1946-6242
- OpenAlex
- W2983383732
- Cited by
- 511
- References
- 52
- Citations by year
- 2026: 87 · 2025: 73 · 2024: 66 · 2023: 71 · 2022: 79 · 2021: 83 · 2020: 47 · 2019: 5
- FWCI
- 53.88
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Science Translational Medicine (publishedVersion)
- PubMed (publishedVersion)
- Funders
- AstraZeneca
- Janssen Biotech
- Janssen Pharmaceuticals
- the Defense Advanced Research Projects Agency (W911NF-12-2-0036)
- the Wyss Institute for Biologically Inspired Engineering at Harvard University
- Topics
- Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Pharmacology › Drug-Induced Hepatotoxicity and Protection
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Health Sciences › Veterinary › Small Animals › Animal testing and alternatives
- Keywords
- organ-on-a-chip, drug toxicity prediction, hepatotoxicity, species-specific toxicity, primary hepatocytes, liver sinusoidal endothelial cells, Kupffer cells, hepatic stellate cells, hepatocyte injury, steatosis, cholestasis, liver fibrosis, microfluidic organ models
- MeSH terms
- Animals, Dogs, Humans, Kupffer Cells, Liver, Liver Diseases, Phenotype, Risk Factors, Species Specificity, Reproducibility of Results, Biomarkers, Rats, Chemical and Drug Induced Liver Injury, Lab-On-A-Chip Devices, Drug-Related Side Effects and Adverse Reactions
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.