Reproducing human and cross-species drug toxicities using a Liver-Chip
The DOI matches its Crossref record; 52 of the 52 references it cites were found in a registry or an index.
Abstract
Nonclinical rodent and nonrodent toxicity models used to support clinical trials of candidate drugs may produce discordant results or fail to predict complications in humans, contributing to drug failures in the clinic. Here, we applied microengineered Organs-on-Chips technology to design a rat, dog, and human Liver-Chip containing species-specific primary hepatocytes interfaced with liver sinusoidal endothelial cells, with or without Kupffer cells and hepatic stellate cells, cultured under physiological fluid flow. The Liver-Chip detected diverse phenotypes of liver toxicity, including hepatocellular injury, steatosis, cholestasis, and fibrosis, and species-specific toxicities when treated with tool compounds. A multispecies Liver-Chip may provide a useful platform for prediction of liver toxicity and inform human relevance of liver toxicities detected in animal studies to better determine safety and human risk.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“the current available in vivo and in vitro DILI models have low and inadequate predictive capability.7,8”
From A High-Throughput Microphysiological Liver Chip System to Model Drug-Induced Liver Injury Using Human Liver Organoids (2024) · cites this paper as [8]
In the citing paper
“Albumin and urea production are widely accepted as functional markers for cultured hepatocytes with the goal of reaching computed production levels observed in human liver in vivo (~20–105 µg and 56–159 µg per 106 hepatocytes per day, respectively)19,26.”
From Performance assessment and economic analysis of a human Liver-Chip for predictive toxicology (2022) · cites this paper as [26]
In the citing paper
“as well as superior activity relative to hepatocytes in a 2D sandwich-assay plate configuration26.”
From Performance assessment and economic analysis of a human Liver-Chip for predictive toxicology (2022) · cites this paper as [26]
In the citing paper
“previously, the same Liver-Chip has been shown to exhibit Phase I and II functional activities that are comparable to freshly isolated human hepatocytes and 3D hepatic spheroids26,30”
From Performance assessment and economic analysis of a human Liver-Chip for predictive toxicology (2022) · cites this paper as [26]
Citations
Cites
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250
Self-citationBhatia, S. N., & Ingber, D. E. (2014) · Nature Biotechnology · doi:10.1038/nbt.2989 · Cited by 3,305
Self-citationConcordance of the toxicity of pharmaceuticals in humans and in animals
Olson, H., Betton, G., Robinson, D., Thomas, K., Monro, A., Kolaja, G., Lilly, P., Sanders, J., Sipes, G., Bracken, W., et al. (2000) · Regulatory Toxicology and Pharmacology · doi:10.1006/rtph.2000.1399 · Cited by 2,050 · cited 1×
“An analysis of 150 drugs that caused adverse events in humans found that regulatory testing in rats and dogs correctly predicted just 71% of toxicities in humans (1).”
BackgroundFrom 3D cell culture to organs-on-chips
Huh, D., Hamilton, G. A., & Ingber, D. E. (2011) · Trends in Cell Biology · doi:10.1016/j.tcb.2011.09.005 · Cited by 1,834 · cited 1×
“In addition, dense 3D constructs often suffer from limited oxygen and nutrient transport, and even when spheroid cultures include endothelial cells and Kupffer cells, they lack physiologically relevant tissue-tissue interfaces and cytoarchitecture that has been demonstrated to be a key driver of cell function (10, 42).”
BackgroundSelf-citationOrgans-on-chips at the frontiers of drug discovery
Esch, E. W., Bahinski, A., & Huh, D. (2015) · Nature Reviews Drug Discovery · doi:10.1038/nrd4539 · Cited by 1,185
Mechanisms of Acetaminophen-Induced Liver Necrosis
Hinson, J. A., Roberts, D. W., & James, L. P. (2010) · Handbook of Experimental Pharmacology · doi:10.1007/978-3-642-00663-0_12 · Cited by 1,006 · cited 1×
“APAP toxicity is caused by direct injury to hepatocytes mediated by the toxic and reactive metabolite N-acetyl-p-benzoquinone imine that depletes cellular glutathione (GSH), causing oxidative stress; it can also be detoxified by hepatocytes, resulting in formation of glucuronide and sulfate metabolites (27).”
BackgroundBjörnsson, E. S., Bergmann, O. M., Björnsson, H. K., Kvaran, R. B., & Olafsson, S. (2013) · Gastroenterology · doi:10.1053/j.gastro.2013.02.006 · Cited by 865
Human kidney proximal tubule-on-a-chip for drug transport and nephrotoxicity assessment
Jang, K.-J., Mehr, A. P., Hamilton, G. A., McPartlin, L. A., Chung, S., Suh, K.-Y., & Ingber, D. E. (2013) · Integrative Biology · doi:10.1039/c3ib40049b · Cited by 849
Self-citationMcGill, M. R., Sharpe, M. R., Williams, C. D., Taha, M., Curry, S. C., & Jaeschke, H. (2012) · Journal of Clinical Investigation · doi:10.1172/jci59755 · Cited by 763 · cited 1×
“Mitochondrial dysfunction has been identified as a hazard for APAP toxicity (47).”
BackgroundDevelopment of a primary human Small Intestine-on-a-Chip using biopsy-derived organoids
Kasendra, M., Tovaglieri, A., Sontheimer-Phelps, A., Jalili-Firoozinezhad, S., Bein, A., Chalkiadaki, A., Scholl, W., Zhang, C., Rickner, H., Richmond, C. A., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-21201-7 · Cited by 754
Self-citation
Research works printed but not linked: 3
- Food and Drug Administration Drug Approval Package : Tracleer (Bosentan) (Food and Drug Administration 2001) pp. 21–290.
- Institute of Medicine (U.S) Committee to Review the Fialuridine (FIAU/FIAC) Clinical Trials in Review of the Fialuridine (FIAU) Clinical Trials F. J. Manning M. N. Swartz Eds. (National Academy Press 1995) 269 pp.
- Food and Drug Administration The Food and Drug Administration Predictive Toxicology Roadmap and Its Implementation; Public Hearing; Request for Comments (Office of the Federal Register National Archives and Records Administration 2018) vol. 83 pp. 30595–30598.
Cited by
Human organs-on-chips for disease modelling, drug development and personalized medicine
Ingber, D. E. (2022) · Nature Reviews Genetics · doi:10.1038/s41576-022-00466-9 · Cited by 1,589
Self-citationA guide to the organ-on-a-chip
Leung, C. M., de Haan, P., Ronaldson-Bouchard, K., Kim, G.-A., Ko, J., Rho, H. S., Chen, Z., Habibovic, P., Jeon, N. L., Takayama, S., et al. (2022) · Nature Reviews Methods Primers · doi:10.1038/s43586-022-00118-6 · Cited by 1,116
Organs-on-chips: into the next decade
Low, L. A., Mummery, C., Berridge, B. R., Austin, C. P., & Tagle, D. A. (2021) · Nature Reviews Drug Discovery · doi:10.1038/s41573-020-0079-3 · Cited by 1,029
Limitations of Animal Studies for Predicting Toxicity in Clinical Trials
Van Norman, G. A. (2019) · JACC: Basic to Translational Science · doi:10.1016/j.jacbts.2019.10.008 · Cited by 732
Organ-on-a-Chip: A New Paradigm for Drug Development
Ma, C., Peng, Y., Li, H., & Chen, W. (2021) · Trends in Pharmacological Sciences · doi:10.1016/j.tips.2020.11.009 · Cited by 576
“Many drugs may show no adverse effects on animals during the preclinical stage but unpredictably exhibit hepatic, cardiac, or renal impairments in patients during clinical trials [3, 4].”
BackgroundHerland, A., Maoz, B. M., Das, D., Somayaji, M. R., Prantil-Baun, R., Novak, R., Cronce, M., Huffstater, T., Jeanty, S. S. F., Ingram, M., et al. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0498-9 · Cited by 500
Self-citationOrganoid and Spheroid Tumor Models: Techniques and Applications
Gunti, S., Hoke, A. T. K., Vu, K. P., & London, N. R. (2021) · Cancers · doi:10.3390/cancers13040874 · Cited by 479
“Microfluidic organ-on-a-chip models have recently been developed for a variety of organs, including lung [63,64], liver [65,66], kidney [67] and heart [68], to model these organs in vitro [62].”
BackgroundRobotic fluidic coupling and interrogation of multiple vascularized organ chips
Novak, R., Ingram, M., Marquez, S., Das, D., Delahanty, A., Herland, A., Maoz, B. M., Jeanty, S. S. F., Somayaji, M. R., Burt, M., et al. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0497-x · Cited by 427
Self-citationHigh-Fidelity Drug-Induced Liver Injury Screen Using Human Pluripotent Stem Cell–Derived Organoids
Shinozawa, T., Kimura, M., Cai, Y., Saiki, N., Yoneyama, Y., Ouchi, R., Koike, H., Maezawa, M., Zhang, R.-R., Dunn, A., et al. (2021) · Gastroenterology · doi:10.1053/j.gastro.2020.10.002 · Cited by 378
Performance assessment and economic analysis of a human Liver-Chip for predictive toxicology
Ewart, L., Apostolou, A., Briggs, S. A., Carman, C. V., Chaff, J. T., Heng, A. R., Jadalannagari, S., Janardhanan, J., Jang, K.-J., Joshipura, S. R., et al. (2022) · Communications Medicine · doi:10.1038/s43856-022-00209-1 · Cited by 337
Self-citationMulti-lineage human iPSC-derived platforms for disease modeling and drug discovery
Sharma, A., Sances, S., Workman, M. J., & Svendsen, C. N. (2020) · Cell Stem Cell · doi:10.1016/j.stem.2020.02.011 · Cited by 296
Ingber, D. E. (2020) · Advanced Science · doi:10.1002/advs.202002030 · Cited by 277
Self-citationThe evolving role of investigative toxicology in the pharmaceutical industry
Pognan, F., Beilmann, M., Boonen, H. C. M., Czich, A., Dear, G., Hewitt, P., Mow, T., Oinonen, T., Roth, A., Steger-Hartmann, T., et al. (2023) · Nature Reviews Drug Discovery · doi:10.1038/s41573-022-00633-x · Cited by 255
Organ-on-a-chip meets artificial intelligence in drug evaluation
Deng, S., Li, C., Cao, J., Cui, Z., Du, J., Fu, Z., Yang, H., & Chen, P. (2023) · Theranostics · doi:10.7150/thno.87266 · Cited by 260
“A study comparing human, dog, and rat liver OoC platform highlighting demonstrated species-specific differences in drug metabolism and toxicity (including hepatocellular injury, steatosis, cholestasis, and fibrosis) [33], showing the significance of employing human-specific cells in some experiments, while confirming…”
BackgroundResultMarx, U. (2020) · ALTEX · doi:10.14573/altex.2001241 · Cited by 218
“It aims to beta test and conduct research using their liver system and the “Human Emulation System” (Emulate, Inc., 2017; Fitzpatrick, 2017).”
BackgroundInfluentialOrgans-on-a-chip models for biological research
Vunjak-Novakovic, G., Ronaldson-Bouchard, K., & Radisic, M. (2021) · Cell · doi:10.1016/j.cell.2021.08.005 · Cited by 248
“This study found liver toxicity and fibrosis from compounds that were discontinued upon rodent studies, proving that OOCs can detect similar effects in rodent-based devices and predict liver injury in humans (Jang et al., 2019).”
BackgroundStrategies to reduce the risks of mRNA drug and vaccine toxicity
Bitounis, D., Jacquinet, E., Rogers, M. A., & Amiji, M. M. (2024) · Nature Reviews Drug Discovery · doi:10.1038/s41573-023-00859-3 · Cited by 224
“A recent study aptly demonstrated that a liver-on-chip consisting of hepatocytes and non-parenchymal cells (Kupffer, stellate and sinusoidal endothelial cells) could generate drug-specific biomarkers and metabolites and reproduce drug-induced cell death 239 .”
Mechanical communication in fibrosis progression
Long, Y., Niu, Y., Liang, K., & Du, Y. (2022) · Trends in Cell Biology · doi:10.1016/j.tcb.2021.10.002 · Cited by 233
Modeling alpha-synuclein pathology in a human brain-chip to assess blood-brain barrier disruption
Pediaditakis, I., Kodella, K. R., Manatakis, D. V., Le, C. Y., Hinojosa, C. D., Tien-Street, W., Manolakos, E. S., Vekrellis, K., Hamilton, G. A., Ewart, L., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-26066-5 · Cited by 237
Self-citation3D cell culture models: Drug pharmacokinetics, safety assessment, and regulatory consideration
Wang, H., Brown, P. C., Chow, E. C. Y., Ewart, L., Ferguson, S. S., Fitzpatrick, S., Freedman, B. S., Guo, G. L., Hedrich, W., Heyward, S., et al. (2021) · Clinical and Translational Science · doi:10.1111/cts.13066 · Cited by 212
Self-citationMicrofluidic organ-on-a-chip models of human liver tissue
Moradi, E., Jalili-Firoozinezhad, S., & Solati-Hashjin, M. (2020) · Acta Biomaterialia · doi:10.1016/j.actbio.2020.08.041 · Cited by 204
Integrating organoids and organ-on-a-chip devices
Zhao, Y., Landau, S., Okhovatian, S., Liu, C., Lu, R. X. Z., Lai, B. F. L., Wu, Q., Kieda, J., Cheung, K., Rajasekar, S., et al. (2024) · Nature Reviews Bioengineering · doi:10.1038/s44222-024-00207-z · Cited by 185
“These systems have been used for liver disease modelling 84 , as well as to study the role of liver metabolism in modulating drug effects 85 and animal species-specific drug responses 84 .”
A human liver organoid screening platform for DILI risk prediction
Zhang, C. J., Meyer, S. R., O’Meara, M. J., Huang, S., Capeling, M. M., Ferrer-Torres, D., Childs, C. J., Spence, J. R., Fontana, R. J., & Sexton, J. Z. (2023) · Journal of Hepatology · doi:10.1016/j.jhep.2023.01.019 · Cited by 191
Limitations of Animal Studies for Predicting Toxicity in Clinical Trials
Van Norman, G. A. (2020) · JACC: Basic to Translational Science · doi:10.1016/j.jacbts.2020.03.010 · Cited by 186
“(68) developed a multispecies liver OC that was able to differentiate speciesspecific toxicities of test compounds in human, canine, and rat species.”
BackgroundOrgans-on-chips technologies – A guide from disease models to opportunities for drug development
Monteduro, A. G., Rizzato, S., Caragnano, G., Trapani, A., Giannelli, G., & Maruccio, G. (2023) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2023.115271 · Cited by 175
Advances in Engineering Human Tissue Models
Moysidou, C.-M., Barberio, C., & Owens, R. M. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.620962 · Cited by 179
The Importance of Mechanical Forces for in vitro Endothelial Cell Biology
Gordon, E., Schimmel, L., & Frye, M. (2020) · Frontiers in Physiology · doi:10.3389/fphys.2020.00684 · Cited by 171
Mehta, V., & Rath, S. N. (2021) · Bio-Design and Manufacturing · doi:10.1007/s42242-020-00112-5 · Cited by 163
Hendriks, D., Artegiani, B., Hu, H., Chuva de Sousa Lopes, S., & Clevers, H. (2021) · Nature Protocols · doi:10.1038/s41596-020-00411-2 · Cited by 159
Mechanical Stimulation: A Crucial Element of Organ-on-Chip Models
Thompson, C. L., Fu, S., Heywood, H. K., Knight, M. M., & Thorpe, S. D. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.602646 · Cited by 178
A Comprehensive Review of Organ-on-a-Chip Technology and Its Applications
Doost, N. F., & Srivastava, S. K. (2024) · Biosensors · doi:10.3390/bios14050225 · Cited by 187
“This allows for the delivery of cell-specific media to each compartment while allowing paracrine interactions between the compartments, as demonstrated by OOC devices that mimic the skin [51] and liver [52].”
BackgroundFerrari, E., Palma, C., Vesentini, S., Occhetta, P., & Rasponi, M. (2020) · Biosensors · doi:10.3390/bios10090110 · Cited by 172
“Various organs and tissues have been modeled, spanning from lung [20,21], heart [22,23], liver [24,25], gut [26,27], kidney [28,29], muscle [30,31], bone [32,33], cartilage [34,35], blood-brain barrier [36,37], as well as nervous systems [38,39].”
BackgroundDrug Toxicity Evaluation Based on Organ-on-a-chip Technology: A Review
Cong, Y., Han, X., Wang, Y., Chen, Z., Lu, Y., Liu, T., Wu, Z., Jin, Y., Luo, Y., & Zhang, X. (2020) · Micromachines · doi:10.3390/mi11040381 · Cited by 140
“[66] constructed a human, dog, and rat two-cell and four-cell species-specific liver chip, and used this chip in combination with microscopic observation, fluorescent staining, and biomarker labeling to verify a variety of phenotypes for drug-induced liver injury, correlation between species-specific liver chips and h…”
BackgroundMethodMicrofluidic Organ-on-a-Chip System for Disease Modeling and Drug Development
Li, Z., Hui, J., Yang, P., & Mao, H. (2022) · Biosensors · doi:10.3390/bios12060370 · Cited by 120
Fernandez-Checa, J. C., Bagnaninchi, P., Ye, H., Sancho-Bru, P., Falcon-Perez, J. M., Royo, F., Garcia-Ruiz, C., Konu, O., Miranda, J., Lunov, O., et al. (2021) · Journal of Hepatology · doi:10.1016/j.jhep.2021.06.021 · Cited by 126
“170 Crucially, this system could identify both species-speci fi c toxicity of drugs, such as APAP, and identify toxic events in hepatocyte and vascular channels.”
BackgroundHuman biomimetic liver microphysiology systems in drug development and precision medicine
Gough, A., Soto-Gutierrez, A., Vernetti, L., Ebrahimkhani, M. R., Stern, A. M., & Taylor, D. L. (2021) · Nature Reviews Gastroenterology & Hepatology · doi:10.1038/s41575-020-00386-1 · Cited by 117
Sharma, K., Dhar, N., Thacker, V. V., Simonet, T. M., Signorino‐Gelo, F., Knott, G. W., & McKinney, J. D. (2021) · eLife · doi:10.7554/elife.66481 · Cited by 130
In vitro grafting of hepatic spheroids and organoids on a microfluidic vascular bed
Bonanini, F., Kurek, D., Previdi, S., Nicolas, A., Hendriks, D., de Ruiter, S., Meyer, M., Clapés Cabrer, M., Dinkelberg, R., García, S. B., et al. (2022) · Angiogenesis · doi:10.1007/s10456-022-09842-9 · Cited by 112
“These chips have been shown to be advantageous for disease induction, liver zonation [23], and studying species-specific toxicity [24].”
BackgroundBreakthroughs and Applications of Organ-on-a-Chip Technology
Koyilot, M. C., Natarajan, P., Hunt, C. R., Sivarajkumar, S., Roy, R., Joglekar, S. S., Pandita, S., Tong, C. W.-C., Marakkar, S., Subramanian, L., et al. (2022) · Cells · doi:10.3390/cells11111828 · Cited by 117
Liver organ-on-chip models for toxicity studies and risk assessment
Messelmani, T., Morisseau, L., Sakai, Y., Legallais, C., Goff, A. L., Leclerc, É., & Jellali, R. (2022) · Lab on a Chip · doi:10.1039/d2lc00307d · Cited by 120
Organ-on-a-chip technology: a novel approach to investigate cardiovascular diseases
Paloschi, V., Sabater‐Lleal, M., Middelkamp, H. H. T., Vivas, A., Johansson, S., van der Meer, A. D., Tenje, M., & Mäegdefessel, L. (2021) · Cardiovascular Research · doi:10.1093/cvr/cvab088 · Cited by 116
“There are current protocols available for the generation of cardiomyocytes, 112 defined atrial and ventricular cardiomyocyte sub-types, 113 ECs as well as pericytes and vascular SMCs. 114,115 An important limitation of iPSC-CMs relates to their immaturity.”
MethodLee, S. J., Jeong, W., & Atala, A. (2024) · Advanced Materials · doi:10.1002/adma.202408032 · Cited by 120
Modeling the Human Body on Microfluidic Chips
Jalili-Firoozinezhad, S., Miranda, C. C., & Cabral, J. M. S. (2021) · Trends in Biotechnology · doi:10.1016/j.tibtech.2021.01.004 · Cited by 101
In Vivo and In Vitro Models to Study Liver Fibrosis: Mechanisms and Limitations
Lee, Y.-S., & Seki, E. (2023) · Cellular and Molecular Gastroenterology and Hepatology · doi:10.1016/j.jcmgh.2023.05.010 · Cited by 94
Rubiano, A., Indapurkar, A., Yokosawa, R., Miedzik, A., Rosenzweig, B., Arefin, A., Moulin, C. M., Dame, K., Hartman, N., Volpe, D. A., et al. (2021) · Clinical and Translational Science · doi:10.1111/cts.12969 · Cited by 96
Tumor-on-a-chip model for advancement of anti-cancer nano drug delivery system
Tian, C., Zheng, S., Liu, X., & Kamei, K. (2022) · Journal of Nanobiotechnology · doi:10.1186/s12951-022-01552-0 · Cited by 101
“Implanting human-derived cells in liver-on-a-chip platforms has proven to be speciesspecific and potential in predicting multiple types of human hepatoxicities [103].”
Background3D cancer models: One step closer to in vitro human studies
Manduca, N., Maccafeo, E., Maria, R. D., Sistigu, A., & Musella, M. (2023) · Frontiers in Immunology · doi:10.3389/fimmu.2023.1175503 · Cited by 110
Human microphysiological systems for drug development
Roth, A., & 2019, M.-W. B. (2021) · Science · doi:10.1126/science.abc3734 · Cited by 94
Drug-Induced Liver Injury: Highlights and Controversies in the Recent Literature
Clinton, J. W., Kiparizoska, S., Aggarwal, S., Woo, S., Davis, W., & Lewis, J. H. (2021) · Drug Safety · doi:10.1007/s40264-021-01109-4 · Cited by 88
3d organ-on-a-chip: the convergence of microphysiological systems and organoids
Baptista, L. S., Porrini, C., Kronemberger, G. S., Kelly, D. J., & Perrault, C. M. (2022) · Frontiers in Cell and Developmental Biology · doi:10.3389/fcell.2022.1043117 · Cited by 90
“The most common problems are absence of efficacy and unforeseen side effects, leading to withdrawal of drugs from the market (Jang et al., 2019).”
BackgroundInfluentialAndrysiak, K., Stępniewski, J., & Dulak, J. (2021) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/s00424-021-02536-z · Cited by 102
Translational Roadmap for the Organs-on-a-Chip Industry toward Broad Adoption
Allwardt, V., Ainscough, A. J., Viswanathan, P., Sherrod, S. D., McLean, J. A., Haddrick, M., & Pensabene, V. (2020) · Bioengineering · doi:10.3390/bioengineering7030112 · Cited by 88
“This indicates that the technology offered is still in development and not in its final form: only in the last couple of years, the emerging OOAC companies have established partnerships and collaborative relationships with pharmaceutical companies to accelerate the development of OOAC technology and testing [27].”
BackgroundMethodMicrofluidic high-throughput 3D cell culture
Ko, J., Park, D., Lee, J., Jung, S., Baek, K., Sung, K. E., Lee, J., & Jeon, N. L. (2024) · Nature Reviews Bioengineering · doi:10.1038/s44222-024-00163-8 · Cited by 88
“Biological complexity can be increasingly implemented in microfluidic cell culture platforms, without compromising throughput, thereby providing an alternative to animal models for certain applications 134 .”
Modeling alcohol-associated liver disease in a human Liver-Chip
Nawroth, J. C., Petropolis, D. B., Manatakis, D. V., Maulana, T. I., Burchett, G., Schlünder, K., Witt, A., Shukla, A., Kodella, K., Ronxhi, J., et al. (2021) · Cell Reports · doi:10.1016/j.celrep.2021.109393 · Cited by 88
“Therefore, we assessed the secretion of cytokines in response to ethanol and LPS, as our Liver-Chip model contains Kupffer cells, which are a major source of proinflammatory cytokines (Jang et al., 2019).”
InfluentialSelf-citationiPSC-derived organ-on-a-chip models for personalized human genetics and pharmacogenomics studies
Palasantzas, V. E. J. M., Tamargo-Rubio, I., Le, K., Slager, J., Wijmenga, C., Jonkers, I. H., Kumar, V., Fu, J., & Withoff, S. (2023) · Trends in Genetics · doi:10.1016/j.tig.2023.01.002 · Cited by 86
The new paradigm in animal testing – “3Rs alternatives”
Poh, W. T., & Stanslas, J. (2024) · Regulatory Toxicology and Pharmacology · doi:10.1016/j.yrtph.2024.105705 · Cited by 100
Varone, A., Nguyen, J. K., Leng, L., Barrile, R., Sliz, J. D., Lucchesi, C., Wen, N., Gravanis, A., Hamilton, G. A., Karalis, K., et al. (2021) · Biomaterials · doi:10.1016/j.biomaterials.2021.120957 · Cited by 94
Self-citationUse of artificial intelligence to enhance phenotypic drug discovery
Malandraki-Miller, S., & Riley, P. R. (2021) · Drug Discovery Today · doi:10.1016/j.drudis.2021.01.013 · Cited by 97
Bein, A., Fadel, C. W., Swenor, B., Cao, W., Powers, R. K., Camacho, D. M., Naziripour, A., Parsons, A., LoGrande, N., Sanjay, S. T., et al. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00899-x · Cited by 83
Self-citationStrelez, C., Chilakala, S., Ghaffarian, K., Lau, R., Spiller, E. R., Ung, N. M., Hixon, D., Yoon, A. Y., Sun, R., Lenz, H., et al. (2021) · iScience · doi:10.1016/j.isci.2021.102509 · Cited by 92
“The microfluidic nature of these systems sustains longer-term experiments and allows for continuous effluent collection to monitor byproducts as an indirect measure of tissue function and viability (Bai et al., 2015; Jang et al., 2019; McAleer et al., 2019; Pavesi et al., 2017).”
Recent Advances in Organ‐on‐Chips Integrated with Bioprinting Technologies for Drug Screening
Rezaei, N. T., Kumar, H., Liu, H., Lee, S. S., Park, S. S., & Kim, K. (2023) · Advanced Healthcare Materials · doi:10.1002/adhm.202203172 · Cited by 83
Organ-on-a-chip platforms for evaluation of environmental nanoparticle toxicity
Lu, R. X. Z., & Radisic, M. (2021) · Bioactive Materials · doi:10.1016/j.bioactmat.2021.01.021 · Cited by 94
Experimental liver models: From cell culture techniques to microfluidic organs‐on‐chip
Polidoro, M. A., Ferrari, E., Marzorati, S., Lleò, A., & Rasponi, M. (2021) · Liver International · doi:10.1111/liv.14942 · Cited by 82
Roadblocks confronting widespread dissemination and deployment of Organs on Chips
Alver, C. G., Drabbe, E., Ishahak, M., & Agarwal, A. (2024) · Nature Communications · doi:10.1038/s41467-024-48864-3 · Cited by 74
“Recapitulation of a speci fi c disease microenvironment ensures that the ef fi cacy of a drug — both in terms of its function and its targeting to a speci fi c organ system — can beappropriatelyvalidatedintheearlystagesofdrugdevelopment 34 – 36 .”
A Review of Biomaterials and Scaffold Fabrication for Organ-on-a-Chip (OOAC) Systems
Osório, L. A., Silva, E., & Mackay, R. E. (2021) · Bioengineering · doi:10.3390/bioengineering8080113 · Cited by 81
Microfluidic Organ-on-a-Chip Devices for Liver Disease Modeling In Vitro
Kanabekova, P., Kadyrova, A., & Kulsharova, G. (2022) · Micromachines · doi:10.3390/mi13030428 · Cited by 70
“used methotrexate to treat 3D layer-membrane co-culture in liver-on-chip [87].”
MethodApplication of new approach methodologies for nonclinical safety assessment of drug candidates
Beilmann, M., Adkins, K., Boonen, H. C. M., Hewitt, P. G., Hu, W., Mader, R., Moore, S., Rana, P., Steger‐Hartmann, T., Villenave, R., et al. (2025) · Nature Reviews Drug Discovery · doi:10.1038/s41573-025-01182-9 · Cited by 85
“For this, NAMs with cells from nonclinical animal species must be developed that can be used in direct comparison with the human NAM, as suggested by InSphero’s cross-species consortium with focus on spheroids and human DILI prediction 101 , or using a liver chip as suggested by Jang et al. 102 .”
Shroff, T., Aina, K., Maass, C., Cipriano, M., Lambrecht, J., Tacke, F., Mosig, A., & Loskill, P. (2022) · Open Biology · doi:10.1098/rsob.210333 · Cited by 68
In Vitro Models for the Study of Liver Biology and Diseases: Advances and Limitations
Kaur, S., Kidambi, S., Ortega-Ribera, M., Thuy, L. T. T., Nieto, N., Cogger, V. C., Xie, W.-F., Tacke, F., & Gracia-Sancho, J. (2023) · Cellular and Molecular Gastroenterology and Hepatology · doi:10.1016/j.jcmgh.2022.11.008 · Cited by 65
Real-time monitoring of liver fibrosis through embedded sensors in a microphysiological system
Farooqi, H. M. U., Kang, B., Khalid, M. A. U., Salih, A. R. C., Hyun, K., Park, S. H., Huh, D., & Choi, K. H. (2021) · Nano Convergence · doi:10.1186/s40580-021-00253-y · Cited by 71
Implementing organ-on-chip in a next-generation risk assessment of chemicals: a review
Nitsche, K. S., Müller, I. I., Malcomber, S., Carmichael, P. L., & Bouwmeester, H. (2022) · Archives of Toxicology · doi:10.1007/s00204-022-03234-0 · Cited by 80
Gut microbiota in health and disease: advances and future prospects
Zhang, Y., Wang, H., Sang, Y., Liu, M., Wáng, Q., Yang, H., & Li, X. (2024) · MedComm · doi:10.1002/mco2.70012 · Cited by 80
On-Chip Construction of Liver Lobules with Self-Assembled Perfusable Hepatic Sinusoid Networks
Ya, S., Ding, W., Li, S., Du, K., Zhang, Y., Li, C., Liu, J., Li, F., Li, P., Luo, T., et al. (2021) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.1c00794 · Cited by 61
Sunildutt, N., Parihar, P., Salih, A. R. C., Lee, S. H., & Choi, K. H. (2023) · Frontiers in Pharmacology · doi:10.3389/fphar.2023.1139229 · Cited by 71
Primary Hepatocyte Isolation and Cultures: Technical Aspects, Challenges and Advancements
Kaur, I., Vasudevan, A., Rawal, P., Tripathi, D. M., Ramakrishna, S., Kaur, S., & Sarin, S. K. (2023) · Bioengineering · doi:10.3390/bioengineering10020131 · Cited by 64
“Species-specific medication toxicities, as well as species-specific variances in the drug response, were simulated between humans and animals using a variety of phenotypes, including hepatotoxicity, steatosis modeling, and fibrosis [77].”
Challenges and Future of Drug-Induced Liver Injury Research—Laboratory Tests
Weber, S., & Gerbes, A. L. (2022) · International Journal of Molecular Sciences · doi:10.3390/ijms23116049 · Cited by 67
Opportunities and challenges with microphysiological systems: a pharma end-user perspective
Ewart, L. C., & Roth, A. B. (2020) · Nature Reviews Drug Discovery · doi:10.1038/d41573-020-00030-2 · Cited by 62
Self-citationAdoption of organ-on-chip platforms by the pharmaceutical industry
Vulto, P., & Joore, J. (2021) · Nature Reviews Drug Discovery · doi:10.1038/s41573-021-00323-0 · Cited by 58
Kammerer, S. (2021) · International Journal of Molecular Sciences · doi:10.3390/ijms221910214 · Cited by 59
“Further, the co-culture system could recapitulate toxicities of several hepatotoxic compounds [123].”
BackgroundSensors in heart-on-a-chip: A review on recent progress
Cho, K. W., Lee, W. H., Kim, B., & Kim, D. (2020) · Talanta · doi:10.1016/j.talanta.2020.121269 · Cited by 63
Hendriks, D. F. G., Vorrink, S. U., Smutny, T., Sim, S. C., Nordling, Å., Ullah, S., Kumondai, M., Jones, B. C., Johansson, I., Andersson, T. B., et al. (2020) · Clinical Pharmacology & Therapeutics · doi:10.1002/cpt.1860 · Cited by 57
Self-citationYouhanna, S. C., Kemas, A. M., Preiss, L. C., Zhou, Y., Shen, J. X., Cakal, S. D., Paqualini, F. S., Goparaju, S. K., Shafagh, R. Z., Lind, J. U., et al. (2022) · Pharmacological Reviews · doi:10.1124/pharmrev.120.000238 · Cited by 67
Modelling host–microbiome interactions in organ-on-a-chip platforms
Shin, Y. C., Than, N., Min, S., Shin, W., & Kim, H. J. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00130-9 · Cited by 65
“…are collaborating 214 to address the challenges and hurdles to the commercialization and preclinical adoption of organ-on-a-chip technologies, focusing on drug testing, in particular, preclinical safety evaluation by cytotoxicity assays of the kidney 215 , liver 216 , skin 217 and bone marrow 9 .”
In vitro immunity: an overview of immunocompetent organ-on-chip models
Morrison, A. I., Sjoerds, M. J., Vonk, L. A., Gibbs, S., & Koning, J. J. (2024) · Frontiers in Immunology · doi:10.3389/fimmu.2024.1373186 · Cited by 61
Comprehensive Development in Organ-On-A-Chip Technology
Joseph, X., Akhil, V., Arathi, A., & Mohanan, P. V. (2021) · Journal of Pharmaceutical Sciences · doi:10.1016/j.xphs.2021.07.014 · Cited by 61
Microphysiological Systems: Stakeholder Challenges to Adoption in Drug Development
Hargrove-Grimes, P., Low, L. A., & Tagle, D. A. (2022) · Cells Tissues Organs · doi:10.1159/000517422 · Cited by 48
“Researchers have developed rat, dog, and human liver tissue chips with species-specific liver cells under physiologically relevant flow, capable of detecting species-specific hepatotoxicity of several known hepatotoxic drugs and experimental compounds [Jang et al., 2019].”
BackgroundLiver-on-a-chip devices: the pros and cons of complexity
Dalsbecker, P., Adiels, C. B., & Goksör, M. (2022) · American Journal of Physiology-Gastrointestinal and Liver Physiology · doi:10.1152/ajpgi.00346.2021 · Cited by 64
Zhang, J., Chan, H. F., Wang, H., Shao, D., Tao, Y., & Li, M. (2021) · Journal of Tissue Engineering · doi:10.1177/2041731420986711 · Cited by 52
Liver–heart on chip models for drug safety
Ferrari, E., & Rasponi, M. (2021) · APL Bioengineering · doi:10.1063/5.0048986 · Cited by 53
Shao, W., Xu, H., Zeng, K., Ye, M., Pei, R., & Wang, K. (2025) · Stem Cell Research & Therapy · doi:10.1186/s13287-025-04139-2 · Cited by 64
Three-dimensional liver models: state of the art and their application for hepatotoxicity evaluation
Zhang, X., Jiang, T., Chen, D., Wang, Q., & Zhang, L. W. (2020) · Critical Reviews in Toxicology · doi:10.1080/10408444.2020.1756219 · Cited by 50
Engineering Organ-on-a-Chip to Accelerate Translational Research
Ko, J., Park, D., Lee, S., Gümüşcü, B., & Jeon, N. L. (2022) · Micromachines · doi:10.3390/mi13081200 · Cited by 59
“Beyond the application of OoC in drug discovery, the incorporation of OoC models with gene editing strategies such as the CRISPR-Cas9 molecular system could help in the screening of cell phenotypes [2,72,111].”
BackgroundMethodOrganoids‐On‐a‐Chip for Personalized Precision Medicine
Man, Y., Liu, Y., Chen, Q., Zhang, Z., Li, M., Xu, L., Tan, Y., & Liu, Z. (2024) · Advanced Healthcare Materials · doi:10.1002/adhm.202401843 · Cited by 58
Rothbauer, M., Bachmann, B., Eilenberger, C., Kratz, S. R. A., Spitz, S., Höll, G., & Ertl, P. (2021) · Micromachines · doi:10.3390/mi12050470 · Cited by 55
“[106] investigated organotypic liver function as a drug screening and disease modelling platform to investigate species-specific responses.”
BackgroundFanizza, F., Campanile, M., Forloni, G., Giordano, C., & Albani, D. (2022) · Journal of Tissue Engineering · doi:10.1177/20417314221095339 · Cited by 58
In Vitro Models for Studying Chronic Drug-Induced Liver Injury
Donato, M. T., Ferrer, G. G., & Tolosa, L. (2022) · International Journal of Molecular Sciences · doi:10.3390/ijms231911428 · Cited by 54
“OoC technology recreates 3D organ microenvironments, such as multicellular architecture, vascular perfusion, fluid flow and other relevant physiological microenvironment of organs [111].”
BackgroundState-of-the-art liver disease research using liver-on-a-chip
Deguchi, S., & Takayama, K. (2022) · Inflammation and Regeneration · doi:10.1186/s41232-022-00248-0 · Cited by 46
“developed Liver-Chip, which cultures primary human, rat, dog hepatocytes, LSECs, KCs, and HSCs in a microfluidic device with two parallel channels [22].”
Liver microphysiological platforms for drug metabolism applications
Kulsharova, G., & Kurmangaliyeva, A. (2021) · Cell Proliferation · doi:10.1111/cpr.13099 · Cited by 52
A History of Regulatory Animal Testing: What Can We Learn?
Swaters, D., van Veen, A., van Meurs, W. P., Turner, J. E., & Ritskes-Hoitinga, M. J. (2022) · Alternatives to Laboratory Animals · doi:10.1177/02611929221118001 · Cited by 56
“Animal experiments still underpin the requirements of regulatory agencies, and according to this court ruling, “the statutory and regulatory scheme here [in the US] explicitly contemplates that the results of animal studies are predictive of the results of human trials”, despite increasing evidence to the contrary.(4,…”
ResultWu, X., Jiang, D., Yang, Y., Li, S., & Ding, Q. (2023) · Cell Regeneration · doi:10.1186/s13619-022-00148-1 · Cited by 52
“An analysis of 150 drugs that caused adverse events in humans showed that the regulatory testings in rats and dogs can only correctly predict 71% of toxicities in humans (Jang et al. 2019).”
Method
Metadata
- Authors
- Jang, K.-J., Otieno, M. A., Ronxhi, J., Lim, H.-K., Ewart, L., Kodella, K. R., Petropolis, D. B., Kulkarni, G., Rubins, J. E., Conegliano, D., Nawroth, J., Simic, D., Lam, W., Singer, M., Barale, E., Singh, B., Sonee, M., Streeter, A. J., Manthey, C., Jones, B., Srivastava, A., Andersson, L. C., Williams, D., Park, H., Barrile, R., Sliz, J., Herland, A., Haney, S., Karalis, K., Ingber, D. E., & Hamilton, G. A.
- Affiliations
- Emulate (United States) (US)
- Janssen Pharmaceutical Research and Development, Nonclinical Safety, 1400 Welsh and McKean Road, Spring House, PA 19477, USA.
- Janssen Pharmaceutical Research and Development, Drug Metabolism and Pharmacokinetics, 1400 Welsh and McKean Road, Spring House, PA 19477, USA.
- AstraZeneca (United Kingdom) (GB)
- Emulate Inc., 27 Drydock Avenue, Boston, MA 02210, USA.
- Janssen Pharmaceutical Research and Development, IPD Biology, 1400 Welsh and McKean Road, Spring House, PA 19477, USA.
- AstraZeneca (Sweden) (SE)
- Harvard University (US)
- Boston Children's Hospital (US)
- Corresponding author
- Otieno, Monicah A.
- Hamilton, Geraldine A.
- ORCID
- Jang, Kyung-Jin
- Otieno, Monicah A.
- Ronxhi, Janey
- Lim, Heng-Keang
- Ewart, Lorna
- Kodella, Konstantia R.
- Petropolis, Debora B.
- Kulkarni, Gauri
- Rubins, Jonathan E.
- Conegliano, David
- Nawroth, Janna
- Lam, Wing
- Singer, Monica
- Barale, Erio
- Singh, Bhanu
- Sonee, Manisha
- Streeter, Anthony J.
- Manthey, Carl
- Srivastava, Abhishek
- Andersson, Linda C.
- Williams, Dominic
- Park, Hyoungshin
- Barrile, Riccardo
- Sliz, Josiah
- Herland, Anna
- Karalis, Katia
- Ingber, Donald E.
- Hamilton, Geraldine A.
- Venue
- Science Translational Medicine
- Published
- 2019-11-06
- Volume
- 11
- Issue
- 517
- ISSN
- 1946-6234 (ISSN-L)
- 1946-6242
- OpenAlex
- W2983383732
- Cited by
- 511
- References
- 52
- Citations by year
- 2026: 87 · 2025: 73 · 2024: 66 · 2023: 71 · 2022: 79 · 2021: 83 · 2020: 47 · 2019: 5
- FWCI
- 53.88
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Science Translational Medicine (publishedVersion)
- PubMed (publishedVersion)
- Funders
- AstraZeneca
- Janssen Biotech
- Janssen Pharmaceuticals
- the Defense Advanced Research Projects Agency (W911NF-12-2-0036)
- the Wyss Institute for Biologically Inspired Engineering at Harvard University
- Topics
- Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Pharmacology › Drug-Induced Hepatotoxicity and Protection
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Health Sciences › Veterinary › Small Animals › Animal testing and alternatives
- Keywords
- organ-on-a-chip, drug toxicity prediction, hepatotoxicity, species-specific toxicity, primary hepatocytes, liver sinusoidal endothelial cells, Kupffer cells, hepatic stellate cells, hepatocyte injury, steatosis, cholestasis, liver fibrosis, microfluidic organ models
- MeSH terms
- Animals, Dogs, Humans, Kupffer Cells, Liver, Liver Diseases, Phenotype, Risk Factors, Species Specificity, Reproducibility of Results, Biomarkers, Rats, Chemical and Drug Induced Liver Injury, Lab-On-A-Chip Devices, Drug-Related Side Effects and Adverse Reactions
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.