Development of a neural interface for high-definition, long-term recording in rodents and nonhuman primates
Open accessThe DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Abstract
A scalable neural interface technology projected to last at least 6 years in the body samples over a thousand brain sites using flexible electronics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Referring to another brain (ECoG) recording, ultrathin film electrode arrays are a promising and widely adopted option for electrodes used on the surface of the cortex, owing to its high recording density in a non-penetrating fashion.[296,343–346]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [344]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neuronal Population Coding of Movement Direction
Georgopoulos, A. P., Schwartz, A. B., & Kettner, R. E. (1986) · Science · doi:10.1126/science.3749885 · Cited by 3,161 · cited 1×
“Direction tuning was computed by relating the mean power with movement direction, similar to spiking models used in motor cortex (35).”
MethodFully integrated silicon probes for high-density recording of neural activity
Jun, J. J., Steinmetz, N. A., Siegle, J. H., Denman, D. J., Bauza, M., Barbarits, B., Lee, A. K., Anastassiou, C. A., Andrei, A., Aydın, Ç., et al. (2017) · Nature · doi:10.1038/nature24636 · Cited by 2,190
Viventi, J., Kim, D.-H., Vigeland, L., Frechette, E. S., Blanco, J. A., Kim, Y.-S., Avrin, A. E., Tiruvadi, V. R., Hwang, S.-W., Vanleer, A. C., et al. (2011) · Nature Neuroscience · doi:10.1038/nn.2973 · Cited by 1,136
Self-citationAnalysis of Dynamic Brain Imaging Data
Mitra, P. P., & Pesaran, B. (1999) · Biophysical Journal · doi:10.1016/s0006-3495(99)77236-x · Cited by 955
Self-citationNeuroGrid: recording action potentials from the surface of the brain
Khodagholy, D., Gelinas, J. N., Thesen, T., Doyle, W., Devinsky, O., Malliaras, G. G., & Buzsáki, G. (2015) · Nature Neuroscience · doi:10.1038/nn.3905 · Cited by 938
Analysis of Dynamic Brain Imaging Data
Mitra, P. P., & Pesaran, B. (1998) · Cold Spring Harbor Laboratory Institutional Repository (Cold Spring Harbor Laboratory) · Cited by 898
Self-citationSpeech synthesis from neural decoding of spoken sentences
Anumanchipalli, G. K., Chartier, J., & Chang, E. F. (2019) · Nature · doi:10.1038/s41586-019-1119-1 · Cited by 883
Charge density and charge per phase as cofactors in neural injury induced by electrical stimulation
McCreery, D. B., Agnew, W. F., Yuen, T. G. H., & Bullara, L. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.102812 · Cited by 708
Wavelet Transform With Tunable Q-Factor
Selesnick, I. W. (2011) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2011.2143711 · Cited by 675 · cited 1×
“To adapt to varying SNR, we applied the hard-threshold SVD denoising to sub-band signals using a tight-frame tunable-Q wavelet transform (TQWT), with 10 log-spaced, redundant frequency bands in addition to a low-pass residual (32).”
MethodThe Optimal Hard Threshold for Singular Values is \(4/\sqrt {3}\)
Gavish, M., & Donoho, D. L. (2014) · IEEE Transactions on Information Theory · doi:10.1109/tit.2014.2323359 · Cited by 675
Cited by
Items 201–211 of 211
Chen, Y., Nam, S., Byun, S.-W., Velcich, P., Cho, S., Lee, C., Lee, J. Y., Weaver, S., Brugnolotto, E., Hwang, E., et al. (2026) · IEEE Symposium on VLSI Technology and Circuits (VLSI Technology and Circuits) · doi:10.1109/vlsitechnologyandcir65830.2026.11577263
Self-citationDesign and Testing of Different Sensor Electrode Grids for Tactile Sensing
Sharma, M. D., & Binong, J. (2026) · IEEE Sensors Letters · doi:10.1109/lsens.2026.3707945
“The localization of particular electrical activity is facilitated by electrode grids [8].”
Dong, Q., Guan, D., Boroomand, S., Biney, B. W., Wu, Y., Hetke, J. F., Cogan, S. F., Orazem, M. E., & Otto, K. J. (2025) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner61569.2025.11588998
“Furthermore, higher spatial resolution afforded by UMEAs improves the precision of neural recordings and the efficacy of neuromodulation applications [7][8][9].”
Intracortical Microstimulation in Brain–Computer Interfaces: Evoking Perception and Plasticity
Hu, P., Chen, C., Zang, Y., Li, X., & Dong, M. I. N. G. (2026) · Cyborg and Bionic Systems · doi:10.34133/cbsystems.0690
“Structurally, current flexible electrodes generally fall into 3 categories: flexible thin-film electrodes [ 35 ], flexible filament electrodes [ 36 , 37 ], and flexible mesh electrodes [ 38 ].”
Hybrid Flexible–Soft Neural Interface as a Practical Solution for Long‐Term Implants
Ji, B., Zhang, Z., You, X., Wang, X., Huang, Y., Cao, J., Bai, R., Chen, J., Zhao, H., Chang, H., et al. (2026) · Rare Metals · doi:10.1002/rar2.70619
Self-citationZheng, K., Yu, W., Gu, Y., He, Z., Wang, X., & Li, Y. (2026) · ACS Materials Letters · doi:10.1021/acsmaterialslett.6c00685
BioNICs: Biomaterial-enabled neural interfaces with closed-loop control for brain disorders
Ju, Y., Dou, Z., Yang, Y., & Yang, F. (2026) · EngMedicine · doi:10.1016/j.engmed.2026.100167
Conformability of laminated beams with shear-lag effects on slightly corrugated elastic substrates
Wang, Z., & Lu, N. (2026) · Journal of Applied Physics · doi:10.1063/5.0323483
Distributed implantable microchips as wireless networks for neural sensing and stimulation
Lee, A.-H., Lee, J., Leung, V., Larson, L., & Nurmikko, A. V. (2026) · Frontiers in Neuroscience · doi:10.3389/fnins.2026.1855768
“Recently, however, such integration has been shown possible in an all-on-Si-wafer approach that incorporated active electronics (Chiang et al., 2020) as well as in polymer-based scalable multielec-trode arrays (Lee K. et al., 2024).”
Pang, B., Yang, G., Cheng, Q., Zhou, S., Wang, Z., Wang, X., Qiu, Y., Gong, H., Bu, T., Xie, B., et al. (2026) · Nature Biomedical Engineering · doi:10.1038/s41551-026-01814-4 · Cited by 1
Wang, Y., Jiao, Y., Jian, W., Zhu, Y., Wang, Z., 马寅集, & Feng, X. (2026) · Science China Materials · doi:10.1007/s40843-026-4430-y
Metadata
- Authors
- Chiang, C.-H., Won, S. M., Orsborn, A. L., Yu, K. J., Trumpis, M., Bent, B., Wang, C., Xue, Y., Min, S., Woods, V., Yu, C., Kim, B. H., Kim, S. B., Huq, R., Li, J., Seo, K. J., Vitale, F., Richardson, A., Fang, H., Huang, Y., Shepard, K., Pesaran, B., Rogers, J. A., & Viventi, J.
- Affiliations
- Duke University (US)
- Sungkyunkwan University (KR)
- University of Washington (US)
- Yonsei University (KR)
- Northwestern University (US)
- University of Wisconsin–Madison (US)
- Michigan Technological University (US)
- Soongsil University (KR)
- Columbia University (US)
- Northeastern University (US)
- Philadelphia VA Medical Center (US)
- University of Pennsylvania (US)
- NYU Langone Health (US)
- Corresponding author
- Chiang, Chia-Han
- Won, Sang Min
- Orsborn, Amy L.
- Yu, Ki Jun
- Pesaran, Bijan
- Rogers, John A.
- Viventi, Jonathan
- ORCID
- Chiang, Chia-Han
- Won, Sang Min
- Orsborn, Amy L.
- Yu, Ki Jun
- Trumpis, Michael
- Bent, Brinnae
- Xue, Yeguang
- Min, Seunghwan
- Woods, Virginia
- Yu, Chunxiu
- Kim, Bong Hoon
- Kim, Sung Bong
- Huq, Rizwan
- Li, Jinghua
- Seo, Kyung Jin
- Vitale, Flavia
- Richardson, Andrew
- Fang, Hui
- Huang, Yonggang
- Shepard, Kenneth
- Pesaran, Bijan
- Rogers, John A.
- Viventi, Jonathan
- Venue
- Science Translational Medicine
- Published
- 2020-04-08
- Volume
- 12
- Issue
- 538
- ISSN
- 1946-6234 (ISSN-L)
- 1946-6242
- PMC
- PMC7478122
- OpenAlex
- W3015415357
- Cited by
- 211
- References
- 49
- Citations by year
- 2026: 22 · 2025: 31 · 2024: 30 · 2023: 35 · 2022: 35 · 2021: 43 · 2020: 15
- FWCI
- 14.67
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Science Translational Medicine (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Digital Commons - Michigan Tech (Michigan Technological University) (submittedVersion)
- Funders
- National Science Foundation (CCF1422914, CCF1564051)
- National Institute of Neurological Disorders and Stroke (U01NS099697)
- Defense Advanced Research Projects Agency (DARPA-BAA-13-20, DARPA-BAA-16-09)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Social Sciences › Education › Undergraduate Neuroscience Education and Research
- Keywords
- neural interfaces, flexible electrode arrays, long-term neural recording, implant encapsulation, implant survival, neuroprosthetics, brain mapping, rodents, non-human primates
- MeSH terms
- Animals, Brain, Brain Mapping, Electrodes, Implanted, Microelectrodes, Primates, Rodentia
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.