Development of a neural interface for high-definition, long-term recording in rodents and nonhuman primates
Open accessThe DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Abstract
A scalable neural interface technology projected to last at least 6 years in the body samples over a thousand brain sites using flexible electronics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Referring to another brain (ECoG) recording, ultrathin film electrode arrays are a promising and widely adopted option for electrodes used on the surface of the cortex, owing to its high recording density in a non-penetrating fashion.[296,343–346]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [344]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neuronal Population Coding of Movement Direction
Georgopoulos, A. P., Schwartz, A. B., & Kettner, R. E. (1986) · Science · doi:10.1126/science.3749885 · Cited by 3,161 · cited 1×
“Direction tuning was computed by relating the mean power with movement direction, similar to spiking models used in motor cortex (35).”
MethodFully integrated silicon probes for high-density recording of neural activity
Jun, J. J., Steinmetz, N. A., Siegle, J. H., Denman, D. J., Bauza, M., Barbarits, B., Lee, A. K., Anastassiou, C. A., Andrei, A., Aydın, Ç., et al. (2017) · Nature · doi:10.1038/nature24636 · Cited by 2,190
Viventi, J., Kim, D.-H., Vigeland, L., Frechette, E. S., Blanco, J. A., Kim, Y.-S., Avrin, A. E., Tiruvadi, V. R., Hwang, S.-W., Vanleer, A. C., et al. (2011) · Nature Neuroscience · doi:10.1038/nn.2973 · Cited by 1,136
Self-citationAnalysis of Dynamic Brain Imaging Data
Mitra, P. P., & Pesaran, B. (1999) · Biophysical Journal · doi:10.1016/s0006-3495(99)77236-x · Cited by 955
Self-citationNeuroGrid: recording action potentials from the surface of the brain
Khodagholy, D., Gelinas, J. N., Thesen, T., Doyle, W., Devinsky, O., Malliaras, G. G., & Buzsáki, G. (2015) · Nature Neuroscience · doi:10.1038/nn.3905 · Cited by 938
Analysis of Dynamic Brain Imaging Data
Mitra, P. P., & Pesaran, B. (1998) · Cold Spring Harbor Laboratory Institutional Repository (Cold Spring Harbor Laboratory) · Cited by 898
Self-citationSpeech synthesis from neural decoding of spoken sentences
Anumanchipalli, G. K., Chartier, J., & Chang, E. F. (2019) · Nature · doi:10.1038/s41586-019-1119-1 · Cited by 883
Charge density and charge per phase as cofactors in neural injury induced by electrical stimulation
McCreery, D. B., Agnew, W. F., Yuen, T. G. H., & Bullara, L. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.102812 · Cited by 708
Wavelet Transform With Tunable Q-Factor
Selesnick, I. W. (2011) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2011.2143711 · Cited by 675 · cited 1×
“To adapt to varying SNR, we applied the hard-threshold SVD denoising to sub-band signals using a tight-frame tunable-Q wavelet transform (TQWT), with 10 log-spaced, redundant frequency bands in addition to a low-pass residual (32).”
MethodThe Optimal Hard Threshold for Singular Values is \(4/\sqrt {3}\)
Gavish, M., & Donoho, D. L. (2014) · IEEE Transactions on Information Theory · doi:10.1109/tit.2014.2323359 · Cited by 675
Nicolelis, M. A. L., Baccala, L. A., Lin, R. C. S., & Chapin, J. K. (1995) · Science · doi:10.1126/science.7761855 · Cited by 547
Fast Poisson disk sampling in arbitrary dimensions
Bridson, R. (2007) · ACM SIGGRAPH 2007 sketches · doi:10.1145/1278780.1278807 · Cited by 524 · cited 1×
“To vary the spatial resolution, we used Poisson disc sampling (18) with a minimum of four electrodes to approximately maintain spatial coverage but vary the average spatial resolution.”
MethodMoshayedi, P., Ng, G., Kwok, J. C. F., Yeo, G. S. H., Bryant, C. E., Fawcett, J. W., Franze, K., & Guck, J. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.01.038 · Cited by 394
A MEMS-based flexible multichannel ECoG-electrode array
Rubehn, B., Bosman, C., Oostenveld, R., Fries, P., & Stieglitz, T. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/3/036003 · Cited by 387
Tissue damage thresholds during therapeutic electrical stimulation
Cogan, S. F., Ludwig, K. A., Welle, C. G., & Takmakov, P. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/021001 · Cited by 386
Fang, H., Yu, K. J., Gloschat, C., Yang, Z., Song, E., Chiang, C.-H., Zhao, J., Won, S. M., Xu, S., Trumpis, M., et al. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0038 · Cited by 278
Self-citationMood variations decoded from multi-site intracranial human brain activity
Sani, O. G., Yang, Y., Lee, M. B., Dawes, H. E., Chang, E. F., & Shanechi, M. M. (2018) · Nature Biotechnology · doi:10.1038/nbt.4200 · Cited by 230
Bioresorbable optical sensor systems for monitoring of intracranial pressure and temperature
Shin, J., Liu, Z., Bai, W., Liu, Y., Yan, Y., Xue, Y., Kandela, I., Pezhouh, M., MacEwan, M. R., Huang, Y., et al. (2019) · Science Advances · doi:10.1126/sciadv.aaw1899 · Cited by 227 · cited 1×
“Although we did not perform histology in these experiments, we have implanted similar devices using t-SiO2 encapsulation in the mouse brain and performed histology at 5 weeks after implant (27).”
MethodSelf-citationFang, H., Zhao, J., Yu, K. J., Song, E., Farimani, A. B., Chiang, C.-H., Jin, X., Xue, Y., Xu, D., Du, W., et al. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1605269113 · Cited by 225
Self-citationRecent Advances in Materials, Devices, and Systems for Neural Interfaces
Won, S. M., Song, E., Zhao, J., Li, J., Rivnay, J., & Rogers, J. A. (2018) · Advanced Materials · doi:10.1002/adma.201800534 · Cited by 206 · cited 1×
“ECoG arrays can also sample neural activity densely, revealing rich spatial and temporal information hidden by traditional approaches such as electroencephalography and conventional ECoG (4, 10).”
BackgroundSelf-citationHotson, G., McMullen, D. P., Fifer, M. S., Johannes, M. S., Katyal, K. D., Para, M. P., Armiger, R., Anderson, W. S., Thakor, N. V., Wester, B. A., et al. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/026017 · Cited by 201
Organic electronics for high-resolution electrocorticography of the human brain
Khodagholy, D., Gelinas, J. N., Zhao, Z., Yeh, M., Long, M., Greenlee, J. D., Doyle, W., Devinsky, O., & Buzsáki, G. (2016) · Science Advances · doi:10.1126/sciadv.1601027 · Cited by 184
Rao, V. R., Sellers, K. K., Wallace, D. L., Lee, M. B., Bijanzadeh, M., Sani, O. G., Yang, Y., Shanechi, M. M., Dawes, H. E., & Chang, E. F. (2018) · Current Biology · doi:10.1016/j.cub.2018.10.026 · Cited by 181
Towards Large-Scale, Human-Based, Mesoscopic Neurotechnologies
Chang, E. F. (2015) · Neuron · doi:10.1016/j.neuron.2015.03.037 · Cited by 163
Gliske, S., Irwin, Z. T., Chestek, C. A., Hegeman, G. L., Brinkmann, B. H., Sagher, O., Garton, H. J. L., Worrell, G. A., & Stacey, W. C. (2018) · Nature Communications · doi:10.1038/s41467-018-04549-2 · Cited by 161
Arieli, A., Grinvald, A., & Slovin, H. (2002) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(01)00507-6 · Cited by 158
A very large-scale microelectrode array for cellular-resolution electrophysiology
Tsai, D., Sawyer, D., Bradd, A., Yuste, R., & Shepard, K. L. (2017) · Nature Communications · doi:10.1038/s41467-017-02009-x · Cited by 152
Self-citationStable long-term BCI-enabled communication in ALS and locked-in syndrome using LFP signals
Milekovic, T., Sarma, A. A., Bacher, D., Simeral, J. D., Saab, J., Pandarinath, C., Sorice, B. L., Blabe, C., Oakley, E. M., Tringale, K. R., et al. (2018) · Journal of Neurophysiology · doi:10.1152/jn.00493.2017 · Cited by 137
Behavioral detection of tactile stimuli during 7–12 Hz cortical oscillations in awake rats
Wiest, M., & Nicolelis, M. A. L. (2003) · Nature Neuroscience · doi:10.1038/nn1107 · Cited by 137
A high-density, high-channel count, multiplexed μECoG array for auditory-cortex recordings
Escabí, M. A., Read, H. L., Viventi, J., Kim, D.-H., Higgins, N. C., Storace, D. A., Liu, A. S. K., Gifford, A. M., Burke, J. F., Campisi, M., et al. (2014) · Journal of Neurophysiology · doi:10.1152/jn.00179.2013 · Cited by 99
Self-citationA MEMS fabricated flexible electrode array for recording surface field potentials
Hollenberg, B. A., Richards, C. D., Richards, R. F., Bahr, D. F., & Rector, D. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.10.016 · Cited by 96
Kaiju, T., Doi, K., Yokota, M., Watanabe, K., Inoue, M., Ando, H., Takahashi, K., Yoshida, F., Hirata, M., & Suzuki, T. (2017) · Frontiers in Neural Circuits · doi:10.3389/fncir.2017.00020 · Cited by 94 · cited 1×
“Many subsets with four to seven electrodes had relative decoding scores of more than half the maximum accuracy and less than twice the minimum error, similar to previous sensory decoding results (19).”
ResultMulti-scale analysis of neural activity in humans: Implications for micro-scale electrocorticography
Kellis, S., Sorensen, L. B., Darvas, F., Sayres, C., O’Neill, K., Brown, R. B., House, P. A., Ojemann, J. G., & Greger, B. E. (2015) · Clinical Neurophysiology · doi:10.1016/j.clinph.2015.06.002 · Cited by 87
Cortical stimulation mapping using epidurally implanted thin-film microelectrode arrays
Molina-Luna, K., Buitrago, M. M., Hertler, B., Schubring-Giese, M., Haiss, F., Nisch, W., Schulz, J. B., & Luft, A. R. (2006) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2006.10.025 · Cited by 74
Song, E., Li, R., Jin, X., Du, H., Huang, Y., Zhang, J., Xia, Y., Fang, H., Lee, Y. K., Yu, K. J., et al. (2018) · ACS Nano · doi:10.1021/acsnano.8b05552 · Cited by 72
Self-citationHemispheric Mapping of Secondary Somatosensory Cortex in the Rat
Benison, A. M., Rector, D. M., & Barth, D. S. (2007) · Journal of Neurophysiology · doi:10.1152/jn.00673.2006 · Cited by 69
Fontanini, A., & Katz, D. B. (2005) · Journal of Neurophysiology · doi:10.1152/jn.01035.2004 · Cited by 68
The effect of micro-ECoG substrate footprint on the meningeal tissue response
Schendel, A. A., Nonte, M. W., Vokoun, C., Richner, T. J., Brodnick, S. K., Atry, F., Frye, S., Bostrom, P., Pashaie, R., Thongpang, S., et al. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/4/046011 · Cited by 67 · cited 1×
“Scar tissue may be observed under similarly sized electrode arrays when chronically implanted based on prior studies (26).”
BackgroundTransferred, Ultrathin Oxide Bilayers as Biofluid Barriers for Flexible Electronic Implants
Song, E., Lee, Y. K., Li, R., Li, J., Jin, X., Yu, K. J., Xie, Z., Fang, H., Zhong, Y., Du, H., et al. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201702284 · Cited by 66
Self-citationSpatial resolution dependence on spectral frequency in human speech cortex electrocorticography
Muller, L., Hamilton, L. S., Edwards, E., Bouchard, K. E., & Chang, E. F. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/5/056013 · Cited by 64 · cited 1×
“The spatial correlation is also highly dependent on the frequency band (29, 30).”
BackgroundLong-term recording reliability of liquid crystal polymer µ ECoG arrays
Woods, V., Trumpis, M., Bent, B., Palopoli-Trojani, K., Chiang, C.-H., Wang, C., Yu, C., Insanally, M. N., Froemke, R. C., & Viventi, J. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aae39d · Cited by 63
Self-citationLee, Y. K., Yu, K. J., Kim, Y., Yoon, Y., Xie, Z., Song, E., Luan, H., Feng, X., Huang, Y., & Rogers, J. A. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b15302 · Cited by 59 · cited 1×
“T-SiO2 encapsulation provides a robust, bendable, and ultrathin (~1 m) moisture barrier that is free of pinhole defects and, unlike polymer-based encapsulation, is reliable while devices are powered with direct current (dc) bias voltages (5, 11).”
BackgroundSelf-citationUnsupervised Learning of Spatiotemporal Interictal Discharges in Focal Epilepsy
Baud, M. O., Kleen, J. K., Anumanchipalli, G. K., Hamilton, L. S., Tan, Y.-L., Knowlton, R. C., & Chang, E. F. (2017) · Neurosurgery · doi:10.1093/neuros/nyx480 · Cited by 49
A low-cost, multiplexed μ ECoG system for high-density recordings in freely moving rodents
Insanally, M., Trumpis, M., Wang, C., Chiang, C.-H., Woods, V., Palopoli-Trojani, K., Bossi, S., Froemke, R. C., & Viventi, J. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/026030 · Cited by 45
Self-citationFabrication and testing of a large area, high density, parylene MEMS
Ledochowitsch, P., Felus, R. J., Gibboni, R. R., Miyakawa, A., Bao, S., & Maharbiz, M. M. (2011) · 2011 IEEE 24th International Conference on Micro Electro Mechanical Systems · doi:10.1109/memsys.2011.5734604 · Cited by 41
Orsborn, A. L., Wang, C., Chiang, K., Maharbiz, M. M., Viventi, J., & Pesaran, B. (2015) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2015.7146643 · Cited by 27
Self-citationA Cortical Recording Platform Utilizing ¿ECoG Electrode Arrays
Kim, J., Wilson, J. A., & Williams, J. C. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353551 · Cited by 25
A low-cost, scalable, current-sensing digital headstage for high channel count μ ECoG
Trumpis, M., Insanally, M., Zou, J., Elsharif, A., Ghomashchi, A., Sertac Artan, N., Froemke, R. C., & Viventi, J. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa5a82 · Cited by 23
Self-citationSpatial oversampling in imaging sensors: Benefits in sensitivity and detection
Caulfield, J. T., Wilson, J. A., & Dhar, N. K. (2012) · IEEE Applied Imagery Pattern Recognition Workshop · doi:10.1109/aipr.2012.6528210 · Cited by 6
Cited by
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
A high-performance neuroprosthesis for speech decoding and avatar control
Metzger, S. L., Littlejohn, K. T., Silva, A. B., Moses, D. A., Seaton, M. P., Wang, R., Dougherty, M. E., Liu, J. R., Wu, P., Berger, M. A., et al. (2023) · Nature · doi:10.1038/s41586-023-06443-4 · Cited by 522
Materials for flexible bioelectronic systems as chronic neural interfaces
Song, E., Li, J., Won, S. M., Bai, W., & Rogers, J. A. (2020) · Nature Materials · doi:10.1038/s41563-020-0679-7 · Cited by 498
Self-citationSkin-inspired soft bioelectronic materials, devices and systems
Zhao, C., Park, J., Root, S. E., & Bao, Z. (2024) · Nature Reviews Bioengineering · doi:10.1038/s44222-024-00194-1 · Cited by 408
Flexible brain–computer interfaces
Tang, X., Shen, H., Zhao, S., Li, N., & Liu, J. (2023) · Nature Electronics · doi:10.1038/s41928-022-00913-9 · Cited by 373
“To improve the stability of flexible BCIs, the current approach involves the formation of an interwoven neural network at the interface through mesh-like flexible electronics.”
Method
Metadata
- Authors
- Chiang, C.-H., Won, S. M., Orsborn, A. L., Yu, K. J., Trumpis, M., Bent, B., Wang, C., Xue, Y., Min, S., Woods, V., Yu, C., Kim, B. H., Kim, S. B., Huq, R., Li, J., Seo, K. J., Vitale, F., Richardson, A., Fang, H., Huang, Y., Shepard, K., Pesaran, B., Rogers, J. A., & Viventi, J.
- Affiliations
- Duke University (US)
- Sungkyunkwan University (KR)
- University of Washington (US)
- Yonsei University (KR)
- Northwestern University (US)
- University of Wisconsin–Madison (US)
- Michigan Technological University (US)
- Soongsil University (KR)
- Columbia University (US)
- Northeastern University (US)
- Philadelphia VA Medical Center (US)
- University of Pennsylvania (US)
- NYU Langone Health (US)
- Corresponding author
- Chiang, Chia-Han
- Won, Sang Min
- Orsborn, Amy L.
- Yu, Ki Jun
- Pesaran, Bijan
- Rogers, John A.
- Viventi, Jonathan
- ORCID
- Chiang, Chia-Han
- Won, Sang Min
- Orsborn, Amy L.
- Yu, Ki Jun
- Trumpis, Michael
- Bent, Brinnae
- Xue, Yeguang
- Min, Seunghwan
- Woods, Virginia
- Yu, Chunxiu
- Kim, Bong Hoon
- Kim, Sung Bong
- Huq, Rizwan
- Li, Jinghua
- Seo, Kyung Jin
- Vitale, Flavia
- Richardson, Andrew
- Fang, Hui
- Huang, Yonggang
- Shepard, Kenneth
- Pesaran, Bijan
- Rogers, John A.
- Viventi, Jonathan
- Venue
- Science Translational Medicine
- Published
- 2020-04-08
- Volume
- 12
- Issue
- 538
- ISSN
- 1946-6234 (ISSN-L)
- 1946-6242
- PMC
- PMC7478122
- OpenAlex
- W3015415357
- Cited by
- 211
- References
- 49
- Citations by year
- 2026: 22 · 2025: 31 · 2024: 30 · 2023: 35 · 2022: 35 · 2021: 43 · 2020: 15
- FWCI
- 14.67
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Science Translational Medicine (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Digital Commons - Michigan Tech (Michigan Technological University) (submittedVersion)
- Funders
- National Science Foundation (CCF1422914, CCF1564051)
- National Institute of Neurological Disorders and Stroke (U01NS099697)
- Defense Advanced Research Projects Agency (DARPA-BAA-13-20, DARPA-BAA-16-09)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Social Sciences › Education › Undergraduate Neuroscience Education and Research
- Keywords
- neural interfaces, flexible electrode arrays, long-term neural recording, implant encapsulation, implant survival, neuroprosthetics, brain mapping, rodents, non-human primates
- MeSH terms
- Animals, Brain, Brain Mapping, Electrodes, Implanted, Microelectrodes, Primates, Rodentia
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.