Validation of Laboratory-Developed Molecular Assays for Infectious Diseases
Open accessThe DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Abstract
SUMMARY: Molecular technology has changed the way that clinical laboratories diagnose and manage many infectious diseases. Excellent sensitivity, specificity, and speed have made molecular assays an attractive alternative to culture or enzyme immunoassay methods. Many molecular assays are commercially available and FDA approved. Others, especially those that test for less common analytes, are often laboratory developed. Laboratories also often modify FDA-approved assays to include different extraction systems or additional specimen types. The Clinical Laboratory Improvement Amendments (CLIA) federal regulatory standards require clinical laboratories to establish and document their own performance specifications for laboratory-developed tests to ensure accurate and precise results prior to implementation of the test. The performance characteristics that must be established include accuracy, precision, reportable range, reference interval, analytical sensitivity, and analytical specificity. Clinical laboratories are challenged to understand the requirements and determine the types of experiments and analyses necessary to meet the requirements. A variety of protocols and guidelines are available in various texts and documents. Many of the guidelines are general and more appropriate for assays in chemistry sections of the laboratory but are applied in principle to molecular assays. This review presents information that laboratories may consider in their efforts to meet regulatory requirements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Implementation of mNGS in the clinical laboratory is a complex endeavour that requires customization of research protocols using a quality management approach consistent with regulatory standards90.”
From Clinical metagenomics (2019) · cites this paper as [90]
In the citing paper
“Clinical laboratories are highly regulated, and general laboratory and testing requirements apply to all molecular diagnostic assays reported for patient care90.”
From Clinical metagenomics (2019) · cites this paper as [90]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
International Organization for Standardization
(2015) · Encyclopedia of Astrobiology · doi:10.1007/978-3-662-44185-5_100574 · Cited by 6,716
Tietz Textbook of Clinical Chemistry
(1999) · Archives of Pathology and Laboratory Medicine · doi:10.5858/123.7.646b · Cited by 2,495
Thompson, M., Ellison, S. L. R., & Wood, R. (2002) · Pure and Applied Chemistry · doi:10.1351/pac200274050835 · Cited by 2,478
Real-Time PCR in Clinical Microbiology: Applications for Routine Laboratory Testing
Espy, M. J., Uhl, J. R., Sloan, L. M., Buckwalter, S. P., Jones, M. F., Vetter, E. A., Yao, J. D. C., Wengenack, N. L., Rosenblatt, J. E., Cockerill, F. R., et al. (2006) · Clinical Microbiology Reviews · doi:10.1128/cmr.19.1.165-256.2006 · Cited by 1,318
Highly sensitive real-time PCR for specific detection and quantification of Coxiella burnetii
Klee, S. R., Tyczka, J., Ellerbrok, H., Franz, T., Linke, S., Baljer, G., & Appel, B. (2006) · BMC Microbiology · doi:10.1186/1471-2180-6-2 · Cited by 323
Saah, A. J., & Hoover, D. R. (1997) · Annals of Internal Medicine · doi:10.7326/0003-4819-126-1-199701010-00026 · Cited by 269
Recommended Principles and Practices for Validating Clinical Molecular Pathology Tests
Jennings, L., Van Deerlin, V. M., & Gulley, M. L. (2009) · Archives of Pathology & Laboratory Medicine · doi:10.5858/133.5.743 · Cited by 250
Use of Bacteriophage MS2 as an Internal Control in Viral Reverse Transcription-PCR Assays
Dreier, J., Störmer, M., & Kleesiek, K. (2005) · Journal of Clinical Microbiology · doi:10.1128/jcm.43.9.4551-4557.2005 · Cited by 220
Research works printed but not linked: 16
- Code of Federal Regulations. 2010. Title 21. Food and drugs, vol. 8, chapter 1. Food and Drug Administration, Department of Health and Human Services, part 56. Institutional review boards. U.S. Government Printing Office, Washington, DC.
- Code of Federal Regulations. 2010. Title 21. Food and drugs, vol. 8, chapter 1. Food and Drug Administration, Department of Health and Human Services, part 864. Hematology and pathology devices, section 864.4020. Analyte specific reagents. U.S. Government Printing Office, Washington, DC.
- Code of Federal Regulations. 2010. Title 21. Food and drugs, vol. 8, chapter 1. Food and Drug Administration, Department of Health and Human Services, part 807. Establishment registration and device listing for manufacturers and initial importers of devices. U.S. Government Printing Office, Washington, DC.
- Code of Federal Regulations. 2010. Title 21. Food and drugs, vol. 8, chapter 1. Food and Drug Administration, Department of Health and Human Services, part 809. In vitro diagnostic products for human use, section 809.10. Labeling for in vitro diagnostic products. U.S. Government Printing Office, Washington, DC.
- Code of Federal Regulations. 2010. Title 21. Food and drugs, vol. 8, chapter 1. Food and Drug Administration, Department of Health and Human Services, part 809. In vitro diagnostic products for human use, section 809.20. General requirements for manufacturers and producers of in vitro diagnostic products. U.S. Government Printing Office, Washington, DC.
- Code of Federal Regulations. 2010. Title 21. Food and drugs, vol. 8, chapter 1. Food and Drug Administration, Department of Health and Human Services, part 809. In vitro diagnostic products for human use, section 809.30. Restrictions on the sale, distribution and use of analyte specific reagents. U.S. Government Printing Office, Washington, DC.
- Code of Federal Regulations. 2010. Title 21. Food and drugs, vol. 8, chapter 1. Food and Drug Administration, Department of Health and Human Services, part 812. Investigational device exemptions. U.S. Government Printing Office, Washington, DC.
- Code of Federal Regulations. 2010. Title 21. Food and drugs, vol. 8, chapter 1. Food and Drug Administration, Department of Health and Human Services, part 820. Quality system regulation. U.S. Government Printing Office, Washington, DC.
- Code of Federal Regulations. 2009. Title 42. Public health, vol. 4, chapter V. Health Care Financing Administration, Department of Health and Human Services, part 493. Laboratory requirements, section 493.1455. Standard: clinical consultant qualifications. U.S. Government Printing Office, Washington, DC.
- Code of Federal Regulations. 2009. Title 42. Public health, vol. 4, chapter V. Health Care Financing Administration, Department of Health and Human Services, part 493. Laboratory requirements, section 493.2. Definitions. U.S. Government Printing Office, Washington, DC.
- Code of Federal Regulations. 2009. Title 42. Public health, vol. 4, chapter V. Health Care Financing Administration, Department of Health and Human Services, part 493. Laboratory requirements, section 493.1253. Standard: establishment and verification of performance specifications. U.S. Government Printing Office, Washington, DC.
- Code of Federal Regulations. 2009. Title 42. Public health, vol. 4, chapter V. Health Care Financing Administration, Department of Health and Human Services, part 493. Laboratory requirements, section 493.1255. Standard: calibration and calibration verification procedures. U.S. Government Printing Office, Washington, DC.
- Code of Federal Regulations. 2009. Title 42. Public health, vol. 4, chapter V. Health Care Financing Administration, Department of Health and Human Services, part 493. Laboratory requirements, section 493.1256. Standard: control Procedures. U.S. Government Printing Office, Washington, DC.
- Code of Federal Regulations. 2009. Title 42. Public health, vol. 4, chapter V. Health Care Financing Administration, Department of Health and Human Services, part 493. Laboratory requirements, section 493.1282. Standard: corrective actions. U.S. Government Printing Office, Washington, DC.
- Social Security Act. Section 1862(a) (1), exclusions from coverage and Medicare as a second payer, now codified as Title 42, chapter 7, exclusions from coverage and Medicare as a second payer, U.S. Code. U.S. House of Representatives, Washington, DC.
- U.S. Department of Health and Human Services, Centers for Medicare and Medicaid Services. 1992. Clinical laboratory improvement amendments of 1988 (CLIA). Fed. Regist. 57:7002-7186. [PubMed] [Google Scholar]
Cited by
Items 301–400 of 550
(2016) · Molecular Microbiology · doi:10.1128/9781555819071.ch6 · Cited by 10
“The assay should be shown to be significantly robust with valid limits of detection, accuracy, specificity, and reproducibility (70).”
MethodRosa, A. M. M., Nazaré, M. R., & Prazeres, D. M. F. (2019) · Biotechnology Journal · doi:10.1002/biot.201800590 · Cited by 8
Emerging infectious disease laboratory and diagnostic preparedness to accelerate vaccine development
Roberts, C. C. (2019) · Human Vaccines & Immunotherapeutics · doi:10.1080/21645515.2019.1634992 · Cited by 8
“2, 39, 41, [63] [64] [65] [66] [67] [68] [69] [70] [71] There may be an incomplete understanding of the biology or epidemiology of a new pathogen, which can delay or confound the selection of a relevant vaccine target and the subsequent assay development to be used to evaluate the candidates.”
BackgroundSahu, P., Satapathy, A., Satapathy, A., & Satapathy, T. (2025) · Letters in Drug Design & Discovery · doi:10.1016/j.lddd.2026.100286 · Cited by 10
Sesler, C. L., & Grigorenko, E. V. (2018) · The Journal of Applied Laboratory Medicine · doi:10.1373/jalm.2017.025924 · Cited by 8
Ötgün, S. N., Kolukirik, C. Z. K., Şahin, N. Ü., Kolukırık, M., Ozgumus, G. G., Turan, M., Elmas, M., & Kılıç, S. (2024) · Journal of Microbiological Methods · doi:10.1016/j.mimet.2024.106899 · Cited by 7
Shen, H., Shi, W., Wang, J., Wang, M., Li, J., Zhang, C., Nie, K., Yang, M., Zhang, Y., Li, A., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0075704 · Cited by 7
“) to calculate the analytical sensitivity [21].”
Michelutti, L., Bulfoni, M., Bolzon, V., & Nencioni, E. (2020) · Cosmetics · doi:10.3390/cosmetics7030054 · Cited by 8
“Plate count is operator-dependent and affected by the microorganisms’ status and the composition of the cosmetic sample and its preservatives; more importantly, it cannot lead to any timely corrective action with a secondary level exam [5,9,22,51,52,62].”
BackgroundSahoo, S., Mandal, S., Das, P., Bhattacharya, S., & Chandy, M. (2021) · Indian Journal of Medical Microbiology · doi:10.1016/j.ijmmb.2021.09.007 · Cited by 11
MicroRNA levels quantified in whole blood varies from PBMCs
Atarod, S., Smith, H., Dickinson, A. M., & Wang, X. (2014) · F1000Research · doi:10.12688/f1000research.4884.2 · Cited by 11
Detection of Salmonella Typhi in Bile by Quantitative Real-Time PCR
Higginson, E. E., Nkeze, J., Permala-Booth, J., Kasumba, I. N., Lagos, R., Hormazábal, J. C., Byrne, A. M. P., Frankel, G. M., Levine, M. M., & Tennant, S. M. (2022) · Microbiology Spectrum · doi:10.1128/spectrum.00249-22 · Cited by 7
“Additionally, routine use of the qPCR method to monitor chronic carriers will require further validation (23).”
MethodAlignment of Fellowship Training with Practice Patterns for Molecular Pathologists
Velu, P., Cushman‐Vokoun, A. M., Ewalt, M. D., Feilotter, H. E., Gastier, J. M., Goswami, R. S., Laudadio, J., Olsen, R. J., Johnson, R., Schlinsog, A., et al. (2022) · Journal of Molecular Diagnostics · doi:10.1016/j.jmoldx.2022.04.011 · Cited by 7
Encarnación-Medina, J., Godoy, L. J., Matta, J. L., & Ortíz, C. (2023) · Cells · doi:10.3390/cells12091339 · Cited by 7
Carossino, M., Balasuriya, U. B. R., Thieulent, C., Barrandeguy, M. E., Vissani, M. A., & Parreño, V. G. (2023) · Viruses · doi:10.3390/v15081626 · Cited by 7
“Cycle threshold (Ct) cut-off values were determined as the average Ct + 3 standard deviations of 12 replicates of the endpoint dilution [64].”
MethodRapid Screening of New Psychoactive Substances Using pDART-QqQ-MS
Hsu, W.-H., Cheng, K., Feng, T.-H., Chen, J., Chen, G., Chen, L., Weng, T., & Hsu, C. (2024) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.4c00124 · Cited by 7
Munson, E. L., Schroeder, E. R., Ross, K. C., Yauck, C., Bieganski, T., Amrhein, R. D., Napierala, M., & Harkins, A. L. (2014) · Journal of Clinical Microbiology · doi:10.1128/jcm.03624-13 · Cited by 7
“A final alternative strategy entails extensive verification of a routine automated cytology processing protocol (as described in Materials and Methods), with subsequent Aptima HPV screening designated a laboratory-modified test (16).”
MethodBertão-Santos, A., Dias, L. D. S., Alves, M. R., Pinheiro, R. O., Moraes, M. O., Manta, F. S. D. N., & Costa, A. D. T. (2024) · PLoS neglected tropical diseases · doi:10.1371/journal.pntd.0012032 · Cited by 11
Detection of Yellow Fever Virus by Quantitative Real-Time PCR (qPCR)
Trindade, G. F., de Lima, S. M. B., Britto, C., & Fernandes, A. G. (2019) · Methods in molecular biology · doi:10.1007/978-1-4939-9833-3_6 · Cited by 6
Reed, J. C., Kwak, G., Piliper, E. A., Degli-Angeli, E., Goecker, E. A., & Greninger, A. L. (2023) · Journal of Clinical Virology · doi:10.1016/j.jcv.2023.105632 · Cited by 6
D'Angelo, R. Y., Weiss, R. L., Wolfe, D., Chinnam, R. B., Murat, A., Gluesing, J. C., & Somers, T. M. (2018) · American Journal of Clinical Pathology · doi:10.1093/ajcp/aqy014 · Cited by 6
“Useful resources include not-forprofit agencies, such as the CLSI, the College of American Pathologists, and the International Organization for Standardization, which develop and recommend clinical laboratory standards and accreditation criteria.(10) To this end, the CLSI has recommended implementation of 12 QSEs ❚Tab…”
BackgroundPerformance of Saliva Samples for COVID-19 Diagnosis by Using the AllplexTM 2019-nCoV Assay Kit
Tapia, C. V., Marcia, C., Ivone, M., Nadia, P., Lesly, M., Camila, G., Valentina, A., Paula, I., & Magne, F. (2021) · Frontiers in Medicine · doi:10.3389/fmed.2021.617399 · Cited by 7
“Food and Drug Administration or the “Conformitè Europëenne” marking), it is necessary to verify some parameters recommended by the manufacturer (11, 12).”
BackgroundMoragas, M., Gomez, S., Fernández, M. F., Golemba, M. D., Palladino, M., Borgnia, D., Ruvinsky, S., Fraquelli, L. E., Buchovsky, A., Bologna, R., et al. (2021) · Frontiers in Medicine · doi:10.3389/fmed.2021.675282 · Cited by 5
Evaluation of 5 Polymerase Chain Reaction Assays for the Detection of Mpox Virus
Fattouh, R., Boissinot, K., Jeong, E., Mendlowitz, A. B., Sjaarda, C. P., Wong, H., Kozak, R. A., Sheth, P. M., & Matukas, L. M. (2024) · The Journal of Infectious Diseases · doi:10.1093/infdis/jiad464 · Cited by 6
Iwai-Itamochi, M., Yoshida, H., Obara, M., Horimoto, E., Kurata, T., & Takizawa, T. (2013) · Journal of Virological Methods · doi:10.1016/j.jviromet.2013.10.004 · Cited by 6
Lin, C., Ho, C., Tamamyan, G., Yang, S., Peng, C., & Chang, J. (2016) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.21945 · Cited by 6
“However, the analytic sensitivity or LOD of HRM analysis in these studies has not been validated strictly as those suggested by Clinical and Laboratory Standards Institute (CLSI) (26) or other authors (27).”
MethodWozniak, A., Geoffroy, E., Miranda, C., Castillo, C., Sanhueza, F., & García, P. (2016) · Diagnostic Microbiology and Infectious Disease · doi:10.1016/j.diagmicrobio.2016.07.008 · Cited by 6
“The yield and quality of nucleic acids (NAs) are crucial for the performance of molecular tests for microbial detection (Muldrew, 2009; Ince &McNally, 2009; Burd, 2010).”
BackgroundStatistics for Method Verification of Qualitative Assays in Clinical Microbiology
Wolk, D. M. (2017) · Clinical Microbiology Newsletter · doi:10.1016/j.clinmicnews.2017.03.008 · Cited by 6
Molecular Contamination and Amplification Product Inactivation
Sefers, S. E., & Schmitz, J. E. (2018) · Springer eBooks · doi:10.1007/978-3-319-33900-9_24 · Cited by 6
Manuel, C. S., Suther, C., Moore, M. D., & Jaykus, L. (2021) · PLoS ONE · doi:10.1371/journal.pone.0248581 · Cited by 6
“Real-time RT-PCR is a major advancement because it essentially performs both amplification and confirmation in a single tube while offering an improved sensitivity (lower LOD) compared to traditional RT-PCR [10].”
MethodInfluentialZemtsova, G. E., Watkins, N. E., & Levin, M. L. (2014) · Journal of Medical Entomology · doi:10.1603/me13221 · Cited by 6
“To determine the reportable range, a linearity test was performed using indicated PCR parameters (Burd 2010).”
Evaluation of antenatal rapid human immunodeficiency virus testing in rural South Africa
Mashamba-Thompson, T. P., Moodley, P., Sartorius, B. K. D., & Drain, P. K. (2018) · Southern African Journal of HIV Medicine · doi:10.4102/sajhivmed.v19i1.771 · Cited by 7
Robinson, D. R., Pennisi, I., Cavuto, M. L., Kiemdé, F., Chamai, M., Some, D. Y., Quigley, E., Malpartida-Cardenas, K., Ndiath, M. O., Correa, S., et al. (2025) · Nature Communications · doi:10.1038/s41467-025-64027-4 · Cited by 8
Zhang, S., Xu, Y., Huang, M., Pan, Y., Shangguan, J., Peng, R., Hu, X., Zheng, F., Luo, N., Chen, X., et al. (2025) · Thorax · doi:10.1136/thorax-2025-223553 · Cited by 5
“24 25 ddPCR mitigates these issues by partitioning the reaction mixture into microreactions, thereby reducing background DNA interference and enhancing assay reliability.”
Shalaby, M., Busin, V., Yan, X., Cengiz, S., Adıgüzel, M. C., Cooper, J. M., Forde, T., & Reboud, J. (2025) · Lab on a Chip · doi:10.1039/d4lc00907j · Cited by 6
Silgado, A., Moure, Z., de Oliveira, M. T., Serre‐Delcor, N., Salvador, F., Oliveira, I., Molina, I., Pumarola, T., Ramı́rez, J. C., & Sulleiro, E. (2020) · Future Microbiology · doi:10.2217/fmb-2020-0023 · Cited by 5
Ünal, E., & Romano, T. A. (2021) · Journal of Zoological and Botanical Gardens · doi:10.3390/jzbg2040040 · Cited by 6
Evaluation of Xpert Carba-R for detecting carbapenemase-producing organisms in South Africa
Duze, S. T., Thomas, T., Pelego, T., Jallow, S., Perovic, O., & Duse, A. G. (2022) · African Journal of Laboratory Medicine · doi:10.4102/ajlm.v12i1.1898 · Cited by 5
Huang, Z., Song, J., Shi, C., Fan, X., Xiao, Y., & Wang, X. (2025) · Frontiers in Cellular and Infection Microbiology · doi:10.3389/fcimb.2025.1529336 · Cited by 6
“The LoD was de fi ned as the concentration of the lowest dilution that could be detected with ≥ 95% probability and calculated by Probit analysis (Burd, 2010), which is a type of regression analysis commonly used in molecular assays to empirically determine the lowest concentration of analyte that…”
Rennert, H., Fernandes, H., Gilani, Z., & Sipley, J. D. (2015) · American Journal of Clinical Pathology · doi:10.1309/ajcpxkuglg3q3mpx · Cited by 5
Peng, Q., Liao, S., He, Y., Liang, L., Su, X., Rao, C., Li, W., Li, S., & Lu, X. (2020) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.23337 · Cited by 5
Jiménez-Montenegro, L., Mendizabal, J. A., Alfonso, L., Azparren, L., & Urrutia, O. (2022) · Scientific Reports · doi:10.1038/s41598-022-20586-w · Cited by 6
Multianalyte tests in clinical care
Aponte, J., Silva, P. J., & Ramos, K. S. (2023) · Elsevier eBooks · doi:10.1016/b978-0-12-824010-6.00030-7 · Cited by 5
Bristy, S. F., Uddin, M. R., Jahan, N., Islam, D. Z., Meghla, B. A., Tisha, T. A., Uddin, M. A., Islam, M. T., Mie, M., Kobatake, E., et al. (2024) · Journal of Applied Pharmaceutical Science · doi:10.7324/japs.2024.175488 · Cited by 8
“This study suggests that diagnostic tests’ accuracy, precision, analytical sensitivity, analytical specificity, repor table range, and internal reference should be validated regularly against gold standards and monitored by proper regulatory authorities [33].”
BackgroundSaunders, N., & Sharp, I. (2014) · Methods in molecular biology · doi:10.1007/978-1-4939-2004-4_6 · Cited by 5
General Guidelines for Quality Assurance of Immunohistochemistry in a Mohs Lab
Kinas, C. G., & Carroll, B. T. (2017) · Dermatologic Surgery · doi:10.1097/dss.0000000000001033 · Cited by 5
Developing a Quality System for Quantitative Laboratory-Developed Tests
Grys, T. E. (2011) · Clinical Microbiology Newsletter · doi:10.1016/j.clinmicnews.2011.11.001 · Cited by 5
Moon, H., Kim, H. N., Kim, J., Hur, M., Kim, H., & Yun, Y. (2016) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2016.08.013 · Cited by 5
Lü, S., Duplat, D., Benitez-Bolivar, P., León, C. M., Villota, S. D., Veloz-Villavicencio, E., Arévalo, V., Jaenes, K., Guo, Y., Cicek, S., et al. (2022) · medRxiv · doi:10.1101/2022.02.27.22271548 · Cited by 5
White-Nose Syndrome Diagnostic Laboratory Network handbook
Alger, K. E., & White Nose Syndrome National Response Team Diagnostic Working Group (2023) · Techniques and methods · doi:10.3133/tm15e1 · Cited by 5
Decentralized molecular diagnostics for viral diseases
Arizti-Sanz, J., & Sabeti, P. C. (2026) · Nature Reviews Bioengineering · doi:10.1038/s44222-026-00456-0 · Cited by 5
“The appropriate number of samples for validation depends on assay characteristics, disease prevalence, reference method accuracy and practical constraints 173 .”
InfluentialRamírez, A. M., Argos, L. B., Lanza, M., Rubio, C. C., Pérez‐Ayala, A., Hisam, S. R., & Rubio, J. M. (2023) · Pathogens and Global Health · doi:10.1080/20477724.2023.2232595 · Cited by 4
“Furthermore, assessment of Dual-LAMP-P spp included the performance of precision measurements, defined as closeness of agreement between independent measurement results obtained under stipulated conditions [46].”
MethodInterpretation and Relevance of Advanced Technique Results
Stratton, C. W., & Tang, Y. (2012) · Springer eBooks · doi:10.1007/978-1-4614-3970-7_47 · Cited by 4
“Molecular assays have been heralded as the “diagnostic tool for the millennium” [ 189, 190 ] .”
MethodStatistics for Method Verification of Quantitative Assays in Clinical Microbiology
Whitfield, N. N., & Wolk, D. M. (2019) · Clinical Microbiology Newsletter · doi:10.1016/j.clinmicnews.2019.05.001 · Cited by 4
Bufkin, K. B., Karim, Z. A., & Silva, J. (2024) · Science Progress · doi:10.1177/00368504241288776 · Cited by 4
Reframing analytical validation in preimplantation genetic testing: phase 1
Popovic, M., Mounts, E. L., Jalas, C., & Scott, R. T. (2025) · Fertility and Sterility · doi:10.1016/j.fertnstert.2025.08.019 · Cited by 5
Assessing Parasite Load in Chagas Disease Patients by Quantitative Multiplex Real-Time PCR
Ramı́rez, J. C., & Moreira, O. C. (2019) · Methods in molecular biology · doi:10.1007/978-1-4939-9148-8_16 · Cited by 4
Chabrolles, H., Pons‐Rejraji, H., Chaput, L., Brebion, A., Fiot, M., Pereira, B., Brugnon, F., & Henquell, C. (2022) · Reproductive BioMedicine Online · doi:10.1016/j.rbmo.2022.09.004 · Cited by 4
“Adequate repeatability is defined by Ct SD <0.2log10, i.e. 0.66Ct; reproducibility by <0.25log10, i.e. 0.83Ct (Burd, 2010; Société Française de Microbiologie (SFM) 2019b).”
IMPLEMENTACIÓN DEL LABORATORIO CLÍNICO MODERNO
Cecilia Tapia, P., S., T. C. V., & C., C. R. (2015) · Revista Médica Clínica Las Condes · doi:10.1016/j.rmclc.2015.11.008 · Cited by 4
Review of critical factors affecting analytical characteristics of serological and molecular assays
Bowden, T. R., Crowther, J. R., & WANG, J. (2021) · Scientific and Technical Review (World Organisation for Animal Health) · doi:10.20506/rst.40.1.3208 · Cited by 4
Domingues, W., dos Santos, E. H., Yamamoto, L., Santi, S. M. D., Kanunfre, K. A., & Okay, T. S. (2021) · Journal of Microbiological Methods · doi:10.1016/j.mimet.2021.106398 · Cited by 4
Gassiep, I., Bauer, M. J., Pagé, M., Harris, P. N. A., & Norton, R. E. (2022) · Access Microbiology · doi:10.1099/acmi.0.000333 · Cited by 4
“The authors note that determining a reportable range requires five–seven concentrations with two replicates each [26].”
BackgroundClinical implementation of RNA signatures for pharmacogenomic decision-making
Gulley, M. L., Tang, Hu, Z., Muallem, & Gulley, M. L. (2011) · Pharmacogenomics and Personalized Medicine · doi:10.2147/pgpm.s14888 · Cited by 5
PCR em tempo real para diagnóstico da leucose enzoótica bovina
Dias, N. L., Júnior, A. A. F., Rodrigues, D. S., & Camargos, M. F. (2012) · Ciência Rural · doi:10.1590/s0103-84782012005000053 · Cited by 5
Molecular Diagnostic Assays for Detection of Viral Respiratory Pathogens in Institutional Outbreaks
Antonishyn, N. A., & Levett, P. N. (2010) · Molecular Diagnosis & Therapy · doi:10.1007/bf03256384 · Cited by 4
“In-house or home-brew assays also require user validation for both analytical limits of detection and, more importantly, clinical sensitivity and specificity.([40,41]) In general, for manufactured assays, the performance specifications that are stated by the manufacturer must be verified.”
BackgroundMossoro‐Kpinde, C. D., Bouassa, R. M., Jenabian, M.-A., Wolyec, S. T., Robin, L., Matta, M., Longo, J. D. D., Grésenguet, G., Andréoletti, L., & Bélec, L. (2016) · AIDS Research and Treatment · doi:10.1155/2016/7954810 · Cited by 4
“In the present report, we evaluated the HIV-1 RNA-based Amplix real-time PCR platform according to the Clinical and Laboratory Standards Institute (CLSI) guidelines for clinical use [10, 11] and guidelines recommended by the pSMILE project (Patient Safety Monitoring in International Laboratories) (http://www.”
MethodSample Selection, Preservation, Transport, and Storage
Dunn, J. J., & Graf, E. H. (2025) · Wiley eBooks · doi:10.1002/9781683674597.ch11 · Cited by 6
Interpretation and Relevance of Advanced Technique Results
Stratton, C. W., & Tang, Y. (2018) · Springer eBooks · doi:10.1007/978-3-319-95111-9_31 · Cited by 8
“Molecular methods such as nucleic acid amplification tests (NAATs) rapidly are being developed and introduced in the clinical laboratory setting [3, 4].”
MethodKim, G. H., Shin, D. J., Choi, J. Y., Choi, H. D., Min, J. G., & Kim, K. I. (2024) · Journal of Fish Diseases · doi:10.1111/jfd.14073 · Cited by 3
Ramı́rez, J. C., & Moreira, O. C. (2025) · Methods in molecular biology · doi:10.1007/978-1-0716-4848-3_11 · Cited by 3
Gürtler, V., Mayall, B. C., Wang, J., & Ghaly-Derias, S. (2013) · Journal of Virological Methods · doi:10.1016/j.jviromet.2013.10.043 · Cited by 3
Quintana, S., Recavarren, M. I., Scialfa, E. A., Viera, I., Rivero, M., & Krivokapich, S. (2015) · Journal of Food Safety · doi:10.1111/jfs.12244 · Cited by 3
Bioinspired Material-Integrated Sensors for Improving Nanoplasmonic Characteristics
İnci, F. (2022) · Hacettepe Journal of Biology and Chemistry · doi:10.15671/hjbc.1035918 · Cited by 3
Payne, M., Ritchie, G., Lawson, T., Young, M., Jang, W., Stefanovic, A., Romney, M. G., Matic, N., & Lowe, C. F. (2025) · Journal of Clinical Virology · doi:10.1016/j.jcv.2025.105762 · Cited by 3
Susceptibility Test Methods: Viruses
Huang, D. D., & Bankowski, M. J. (2015) · ASM Press eBooks · doi:10.1128/9781555817381.ch112 · Cited by 3
Templar, A., Woodhouse, S., Keshavarz‐Moore, E., & Nesbeth, D. (2016) · Journal of Microbiological Methods · doi:10.1016/j.mimet.2016.05.013 · Cited by 3
Sönmez, C., Çöplü, N., Gözalan, A., Akin, L., & Esen, B. (2017) · Journal of Immunological Methods · doi:10.1016/j.jim.2017.03.012 · Cited by 3
Development and Validation of Molecular Assays for Limited Tissue Samples
Sussman, R. T., & Rosenbaum, J. N. (2019) · Acta Cytologica · doi:10.1159/000499109 · Cited by 4
Golemba, M. D., Moragas, M., Fernández, M. F., Borgnia, D., Ruhle, M., Palladino, M., Arias, A. P., Ruvinsky, S., Bologna, R., & Mangano, A. M. (2022) · Revista Argentina de Microbiología · doi:10.1016/j.ram.2022.09.002 · Cited by 4
“All statistical analyses were performed with the software R (version 3.6.0).”
MethodInfluentialDetection of Multiple Fungal Species in Blood Samples by Real-Time PCR: an Interpretative Challenge
Halliday, C. L., Sorrell, T. C., & Chen, S. C.-A. (2014) · Journal of Clinical Microbiology · doi:10.1128/jcm.01685-14 · Cited by 3
“The sensitivity, specificity, and accuracy (3) of modern assays is high for tissue and sterile-site specimens (1, 4) but not blood, where the fungal burden is low ( 10 CFU/ml).”
BackgroundMOVER approximated CV: A tool for quantifying precision in ratiometric droplet digital PCR assays
Dide-Agossou, C., Rossmassler, K., Reid, J. J., Purohit, J., Savić, R. M., Nahid, P., Phillips, P. P. J., Moore, C. M., & Walter, N. D. (2022) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2022.114664 · Cited by 2
Ramírez, C. C., Enríquez-Valencia, C. E., Méndez-Callejas, G., Meza, G., Tafur-Gómez, G. A., & Corredor, D. W. S. (2024) · Heliyon · doi:10.1016/j.heliyon.2024.e41088 · Cited by 3
Ahmed, T., Platts-Mills, J. A., Pholwat, S., Campbell, G., Wettstone, E. G., Smith, J. A., & Taniuchi, M. (2025) · Journal of Environmental Engineering · doi:10.1061/joeedu.eeeng-7921 · Cited by 2
White, S. J., Tchuenkam, V. P. K., Mbouh, M., Gaither, C., Bouopda-Tuedom, A. G., Kiam, B. C., Popkin-Hall, Z. R., Sadler, J. M., Carey-Ewend, K., Hand, E., et al. (2025) · PLoS neglected tropical diseases · doi:10.1371/journal.pntd.0013549 · Cited by 4
“To determine the limit of detection (LOD) for the P. ovale spp. gametocyte assay, probit analysis was conducted on replicate rt-qPCR runs using templates with known copy number concentrations [49].”
JC virus PCR assay reporting for PML: promises, perils, and pitfalls
Avasarala, J., & Gangadhara, S. (2025) · Journal of Neurology · doi:10.1007/s00415-025-13452-y · Cited by 2
“This constitutes a systems-level error: a failure of laboratory transparency that undermines patient safety [21].”
Gupta, J., Gataa, I. S., Singh, N. S. S., Padmapriya, G., Ray, S., Pal, A., Arora, V., Smerat, A., Abilkasimov, A., & Latipova, M. (2025) · Folia Microbiologica · doi:10.1007/s12223-025-01367-0 · Cited by 6
Moreira, O. C., Faier-Pereira, A., Valença-Barbosa, C., & Finamore-Araújo, P. (2025) · Methods in molecular biology · doi:10.1007/978-1-0716-4848-3_9 · Cited by 2
Validation of a multiplex qRT-PCR assay for the detection of RSV, influenza A/B virus and SARS-CoV-2
Bulgurcu, A., & Sayıner, A. A. (2026) · BMC Microbiology · doi:10.1186/s12866-025-04646-5 · Cited by 2
“The sample concentrations selected for the precision study were adjusted to approximate the limit of detection [9, 10].”
Validation of a 2-Gene Blood Test for Kawasaki Disease in Febrile Children
Kuo, H., Xue, X., Liu, F., Mortensen, R. D., Chou, C. J., Jin, B., Wei, J., Luo, Q., Weng, K.-P., Guo, M. M., et al. (2026) · JAMA Network Open · doi:10.1001/jamanetworkopen.2026.15420 · Cited by 2
Li, S. C., Sparks, K. J., & Sender, L. S. (2020) · Medical Sciences · doi:10.3390/medsci8010014 · Cited by 2
“Taken together, these parameters indicated that our LC480 PCR assay system met the standard, as set by Burd’s guidelines [18].”
MethodInfluentialComparison of the clinical sensitivity and specificity of two commercial RNA SARS-CoV-2 assays
Litchfield, M., Brookes, P., Ojrzynska, A., Kavi, J., & Dawood, R. M. (2022) · International Journal of Infectious Diseases · doi:10.1016/j.ijid.2022.02.032 · Cited by 2
Lieberman, J. A., & Bourassa, L. A. (2023) · Current Fungal Infection Reports · doi:10.1007/s12281-023-00471-3 · Cited by 2
Latella, A., Gómez, S., Palladino, M., Navia, M., Mangano, A. M., Borgnia, D., Rino, P. B., González, C., Felice, M. S., Rosé, A., et al. (2023) · Journal of Pediatric Hematology/Oncology · doi:10.1097/mph.0000000000002691 · Cited by 1
Zelyas, N. J., Pabbaraju, K., Croxen, M. A., Lynch, T., McCullough, E., Murphy, S. A., Shokoples, S., Wong, A. A., Kanji, J. N., & Tipples, G. A. (2023) · Scientific Reports · doi:10.1038/s41598-023-44796-y · Cited by 2
“The %CV of the markers had a range of 0.22–1.08% for inter-assay reproducibility and 0.01–1.28% for intra-assay reproducibility, which were deemed acceptable based on a threshold of 15% 37 .”
MethodInfluentialAldana‐Caballero, A., Álvarez, E. M., Mayordomo, R., & Tejedor, F. M. (2023) · Heliyon · doi:10.1016/j.heliyon.2023.e23550 · Cited by 2
“Missed positives in precision assays could make up for the samples below the 20 % of the LOD used on the precision assays, as suggested in literature [12] and/or the differences of instruments (Thermocycler, pipettes, handling) in a different laboratory.”
MethodGao, P., Fan, Y., Kong, X., Zhang, R., Chen, L., Jiang, Y., Liu, Y., Zhao, M., Deng, G., Cao, Y., et al. (2023) · Frontiers in Microbiology · doi:10.3389/fmicb.2023.1249085 · Cited by 2
“…2019 ( COVID-19 ), which has become a sustained global pandemic The feasibility of a detection system to be applied in clinical laboratories is influenced by various factors, including instrument cost, laboratory space, complexity, testing capability, handling time, and result time (Burd, 2010).”
BackgroundShincy, M. R., Govindan, V., Akhila, M. M., Shilpa, R., & Lingegowda, R. K. (2024) · Bioanalysis · doi:10.4155/bio-2023-0111 · Cited by 2
Lewis, J. D., & Salipante, S. J. (2024) · Journal of Clinical Microbiology · doi:10.1128/jcm.00243-24 · Cited by 2
“When performing NAATs for clinical molecular diagnosis, it is critical to include an appropriate combination of negative, positive, and internal controls to assess successful assay performance (28–30).”
MethodFavacho, J. D. F. R., Leite, K. K., Jacomasso, T., Farias, A. B., Filho, L. C. F., Gomes, S. T. M., dos Reis, H. S., Mota, G. D., Schluga, P. H. D. C., Tassi, W. S., et al. (2024) · Diagnostics · doi:10.3390/diagnostics14090892 · Cited by 3
“Detection of a host gene also controls for the reagents’ quality and adequate instrument operation, which, together with the production of reagents under current good manufacturing practices (cGMPs), ensures the high performance of the newly developed test [43].”
BackgroundMethodCoupland, L. J., Woodward, K., Dervisevic, S., Hale, R., & Brolly, S. (2024) · Viruses · doi:10.3390/v16050671 · Cited by 2
“However, variability is still observed when testing clinical samples in the laboratory, particularly between institutions [9,16,17]; therefore, validation procedures are required for each new assay introduced [18].”
BackgroundZhang, Y., Tian, W., Zhang, S., Lin, L., Song, C., Liu, Y., Xu, Y., Zhang, L., Geng, S., Li, X., et al. (2024) · The Journal of Infectious Diseases · doi:10.1093/infdis/jiae442 · Cited by 4
Metadata
- Authors
- Burd, E. M.
- Affiliations
- Emory University Hospital (US)
- Corresponding author
- Burd, Eileen M.
- ORCID
- Burd, Eileen M.
- Venue
- Clinical Microbiology Reviews
- Publisher
- American Society for Microbiology
- Published
- 2010-07
- Volume
- 23
- Issue
- 3
- Pages
- 550-576
- ISSN
- 0893-8512 (ISSN-L)
- 1098-6618
- PMC
- PMC2901657
- OpenAlex
- W2096278562
- Cited by
- 550
- References
- 48
- Citations by year
- 2026: 30 · 2025: 43 · 2024: 36 · 2023: 42 · 2022: 42 · 2021: 41 · 2020: 38 · 2019: 36 · 2018: 39 · 2017: 37 · 2016: 44 · 2015: 35 · 2014: 32 · 2013: 21 · 2012: 18
- FWCI
- 1.74
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- journals.asm.org/non-commercial-tdm-license (tdm)
- Locations
- Clinical Microbiology Reviews (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Medicine › Microbiology (medical) › Bacterial Identification and Susceptibility Testing
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Healthcare Regulation
- Keywords
- laboratory-developed tests, molecular diagnosis, infectious diseases, assay validation, analytical sensitivity, analytical specificity, precision and accuracy, reference values, assay modification
- MeSH terms
- Communicable Diseases, Humans, Clinical Laboratory Techniques, Molecular Diagnostic Techniques, Validation Studies as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.