Validation of Laboratory-Developed Molecular Assays for Infectious Diseases
Open accessThe DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Abstract
SUMMARY: Molecular technology has changed the way that clinical laboratories diagnose and manage many infectious diseases. Excellent sensitivity, specificity, and speed have made molecular assays an attractive alternative to culture or enzyme immunoassay methods. Many molecular assays are commercially available and FDA approved. Others, especially those that test for less common analytes, are often laboratory developed. Laboratories also often modify FDA-approved assays to include different extraction systems or additional specimen types. The Clinical Laboratory Improvement Amendments (CLIA) federal regulatory standards require clinical laboratories to establish and document their own performance specifications for laboratory-developed tests to ensure accurate and precise results prior to implementation of the test. The performance characteristics that must be established include accuracy, precision, reportable range, reference interval, analytical sensitivity, and analytical specificity. Clinical laboratories are challenged to understand the requirements and determine the types of experiments and analyses necessary to meet the requirements. A variety of protocols and guidelines are available in various texts and documents. Many of the guidelines are general and more appropriate for assays in chemistry sections of the laboratory but are applied in principle to molecular assays. This review presents information that laboratories may consider in their efforts to meet regulatory requirements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Implementation of mNGS in the clinical laboratory is a complex endeavour that requires customization of research protocols using a quality management approach consistent with regulatory standards90.”
From Clinical metagenomics (2019) · cites this paper as [90]
In the citing paper
“Clinical laboratories are highly regulated, and general laboratory and testing requirements apply to all molecular diagnostic assays reported for patient care90.”
From Clinical metagenomics (2019) · cites this paper as [90]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
International Organization for Standardization
(2015) · Encyclopedia of Astrobiology · doi:10.1007/978-3-662-44185-5_100574 · Cited by 6,716
Tietz Textbook of Clinical Chemistry
(1999) · Archives of Pathology and Laboratory Medicine · doi:10.5858/123.7.646b · Cited by 2,495
Thompson, M., Ellison, S. L. R., & Wood, R. (2002) · Pure and Applied Chemistry · doi:10.1351/pac200274050835 · Cited by 2,478
Real-Time PCR in Clinical Microbiology: Applications for Routine Laboratory Testing
Espy, M. J., Uhl, J. R., Sloan, L. M., Buckwalter, S. P., Jones, M. F., Vetter, E. A., Yao, J. D. C., Wengenack, N. L., Rosenblatt, J. E., Cockerill, F. R., et al. (2006) · Clinical Microbiology Reviews · doi:10.1128/cmr.19.1.165-256.2006 · Cited by 1,318
Highly sensitive real-time PCR for specific detection and quantification of Coxiella burnetii
Klee, S. R., Tyczka, J., Ellerbrok, H., Franz, T., Linke, S., Baljer, G., & Appel, B. (2006) · BMC Microbiology · doi:10.1186/1471-2180-6-2 · Cited by 323
Saah, A. J., & Hoover, D. R. (1997) · Annals of Internal Medicine · doi:10.7326/0003-4819-126-1-199701010-00026 · Cited by 269
Recommended Principles and Practices for Validating Clinical Molecular Pathology Tests
Jennings, L., Van Deerlin, V. M., & Gulley, M. L. (2009) · Archives of Pathology & Laboratory Medicine · doi:10.5858/133.5.743 · Cited by 250
Use of Bacteriophage MS2 as an Internal Control in Viral Reverse Transcription-PCR Assays
Dreier, J., Störmer, M., & Kleesiek, K. (2005) · Journal of Clinical Microbiology · doi:10.1128/jcm.43.9.4551-4557.2005 · Cited by 220
Research works printed but not linked: 16
- Code of Federal Regulations. 2010. Title 21. Food and drugs, vol. 8, chapter 1. Food and Drug Administration, Department of Health and Human Services, part 56. Institutional review boards. U.S. Government Printing Office, Washington, DC.
- Code of Federal Regulations. 2010. Title 21. Food and drugs, vol. 8, chapter 1. Food and Drug Administration, Department of Health and Human Services, part 864. Hematology and pathology devices, section 864.4020. Analyte specific reagents. U.S. Government Printing Office, Washington, DC.
- Code of Federal Regulations. 2010. Title 21. Food and drugs, vol. 8, chapter 1. Food and Drug Administration, Department of Health and Human Services, part 807. Establishment registration and device listing for manufacturers and initial importers of devices. U.S. Government Printing Office, Washington, DC.
- Code of Federal Regulations. 2010. Title 21. Food and drugs, vol. 8, chapter 1. Food and Drug Administration, Department of Health and Human Services, part 809. In vitro diagnostic products for human use, section 809.10. Labeling for in vitro diagnostic products. U.S. Government Printing Office, Washington, DC.
- Code of Federal Regulations. 2010. Title 21. Food and drugs, vol. 8, chapter 1. Food and Drug Administration, Department of Health and Human Services, part 809. In vitro diagnostic products for human use, section 809.20. General requirements for manufacturers and producers of in vitro diagnostic products. U.S. Government Printing Office, Washington, DC.
- Code of Federal Regulations. 2010. Title 21. Food and drugs, vol. 8, chapter 1. Food and Drug Administration, Department of Health and Human Services, part 809. In vitro diagnostic products for human use, section 809.30. Restrictions on the sale, distribution and use of analyte specific reagents. U.S. Government Printing Office, Washington, DC.
- Code of Federal Regulations. 2010. Title 21. Food and drugs, vol. 8, chapter 1. Food and Drug Administration, Department of Health and Human Services, part 812. Investigational device exemptions. U.S. Government Printing Office, Washington, DC.
- Code of Federal Regulations. 2010. Title 21. Food and drugs, vol. 8, chapter 1. Food and Drug Administration, Department of Health and Human Services, part 820. Quality system regulation. U.S. Government Printing Office, Washington, DC.
- Code of Federal Regulations. 2009. Title 42. Public health, vol. 4, chapter V. Health Care Financing Administration, Department of Health and Human Services, part 493. Laboratory requirements, section 493.1455. Standard: clinical consultant qualifications. U.S. Government Printing Office, Washington, DC.
- Code of Federal Regulations. 2009. Title 42. Public health, vol. 4, chapter V. Health Care Financing Administration, Department of Health and Human Services, part 493. Laboratory requirements, section 493.2. Definitions. U.S. Government Printing Office, Washington, DC.
- Code of Federal Regulations. 2009. Title 42. Public health, vol. 4, chapter V. Health Care Financing Administration, Department of Health and Human Services, part 493. Laboratory requirements, section 493.1253. Standard: establishment and verification of performance specifications. U.S. Government Printing Office, Washington, DC.
- Code of Federal Regulations. 2009. Title 42. Public health, vol. 4, chapter V. Health Care Financing Administration, Department of Health and Human Services, part 493. Laboratory requirements, section 493.1255. Standard: calibration and calibration verification procedures. U.S. Government Printing Office, Washington, DC.
- Code of Federal Regulations. 2009. Title 42. Public health, vol. 4, chapter V. Health Care Financing Administration, Department of Health and Human Services, part 493. Laboratory requirements, section 493.1256. Standard: control Procedures. U.S. Government Printing Office, Washington, DC.
- Code of Federal Regulations. 2009. Title 42. Public health, vol. 4, chapter V. Health Care Financing Administration, Department of Health and Human Services, part 493. Laboratory requirements, section 493.1282. Standard: corrective actions. U.S. Government Printing Office, Washington, DC.
- Social Security Act. Section 1862(a) (1), exclusions from coverage and Medicare as a second payer, now codified as Title 42, chapter 7, exclusions from coverage and Medicare as a second payer, U.S. Code. U.S. House of Representatives, Washington, DC.
- U.S. Department of Health and Human Services, Centers for Medicare and Medicaid Services. 1992. Clinical laboratory improvement amendments of 1988 (CLIA). Fed. Regist. 57:7002-7186. [PubMed] [Google Scholar]
Cited by
Items 501–550 of 550
Sampieri, L., Rodríguez-Lombardi, G., & Bernardi, M. E. (2024) · Transfusion and Apheresis Science · doi:10.1016/j.transci.2024.103869
Impact of COVID-19 on the development of detection methods: a narrative review.
Djedović, H. (2023) · Bioengineering Studies · doi:10.37868/bes.v4i1.id257
“For these reasons, no test will ever be 100 percent accurate, and the lack of a gold standard against which to assess future performance only compounds the problem [21].”
BackgroundChurch, D. L. (2024) · Wiley eBooks · doi:10.1002/9781683673941.ch53
Piliper, E. A., Reed, J. C., & Greninger, A. L. (2024) · medRxiv · doi:10.1101/2024.06.13.24308891
Rapid on-site detection of echinococcosis and schistosomiasis based on RPA
Tian, L., Shi, Y., Yu, Y., & Wang, Y. (2024) · Memórias do Instituto Oswaldo Cruz · doi:10.1590/0074-02760230244
“(18) RPA is a new nucleic acid isothermal amplification technology developed by Piepenburg et al. using protein recombination and repair involved in cell DNA synthesis.”
MethodSystems for Identification of Bacteria and Fungi
Heaton, P. R., & Bhatti, M. M. (2023) · Wiley eBooks · doi:10.1002/9781683670438.mcm0006.pub2
Specimen Collection, Transport, and Processing: Virology
Dunn, J. J., & Pinsky, B. A. (2023) · Wiley eBooks · doi:10.1002/9781683674849.mcm0082
Systems for Identification of Bacteria and Fungi
Heaton, P. R., & Bhatti, M. M. (2023) · ClinMicroNow · doi:10.1002/9781683670438.mcm0006
Sequence‐Based Identification and Typing
She, R. C., Fisher, M. A., Kozyreva, V. K., & Yang, S. (2023) · Wiley eBooks · doi:10.1002/9781683670438.cmph0156
General Aspects of Molecular Diagnostics
Cybulski, R. J., Chiaruttini, J., Lee, M. J., Lieberman, J. A., Salipante, S. J., Binnicker, M. J., Hill, J. N., Stevenson, J. B., Bard, J. D., & Truong, T. (2023) · ClinMicroNow · doi:10.1002/9781683670438.cmph0153
Specimen Collection, Transport, and Processing: Virology
Dunn, J. J., & Pinsky, B. A. (2023) · Wiley eBooks · doi:10.1002/9781683670438.mcm0082 · Cited by 1
Park, B., Won, E. J., Sung, H., & Kim, M. (2025) · Parasites Hosts and Diseases · doi:10.3347/phd.24071
“Instead of clinical samples, spiking samples with known parasitic pathogens could serve as alternative materials for assay performance evaluation [15,16].”
Performance Characteristic: Analytical Specificity
Rebekah M. Martin PhD, D. (2025) · doi:10.1002/9781683674481.ch11
Parikh, B. A., & Anderson, N. W. (2025) · Wiley eBooks · doi:10.1002/9781683674597.ch12
Verification, Validation, and Quality Assurance for Nucleic Acid Amplification Tests
Larkin, P. M. K., Mehta, N., & Martin, R. M. (2025) · doi:10.1002/9781683674597.ch15
Performance evaluation of Human Immunodeficiency Virus Type 1 RNA Quantitative Diagnostic Kit assay
Vázquez, A. F., & Pérez-Guevara, M. T. (2025) · Jornal Brasileiro de Doenças Sexualmente Transmissíveis · doi:10.5327/dst-2177-8264-2025371439
Karita, H. C. S., Magaret, A., Selke, S., Pascual, R., Irimia, B., Barbee, L. A., Wald, A., & Soge, O. O. (2025) · Open Forum Infectious Diseases · doi:10.1093/ofid/ofaf388
“…with known concentrations of cultured organisms are generally acceptable for validation and evaluation of the performance of molecular assays [20, 21], they do not reflect the full complexity of real-world clinical specimens, including pathogen diversity and the biological variations found in…”
Wang, C. Y. T., Ballard, E. L., Pava, Z., Marquart, L., Gaydon, J., Murphy, S. C., Whiley, D. M., O'Rourke, P. K., & McCarthy, J. S. (2021) · Figshare · doi:10.6084/m9.figshare.14398492
Choi, Y. J., Kim, Y., Park, H. J., Kim, D., Lee, H., Kim, Y. A., & Lee, K. (2024) · Figshare · doi:10.6084/m9.figshare.25556485
Choi, Y. J., Kim, Y., Park, H. J., Kim, D., Lee, H., Kim, Y. A., & Lee, K. (2024) · Figshare · doi:10.6084/m9.figshare.25556696
Faifi, K. H. A., Zoeir, A. R., Musawa, H. H., Albalawi, W. F., Alqhtani, M. S., Altemani, S. S., Albalawi, K. F., Alsulami, B. M., Alahmari, M. M., Aljohani, O. M., et al. (2025) · Journal of Clinical Practice and Medical Research · doi:10.59324/jcpmr.2025.1(3).21
Hauner, A., Milua, S., Rogé, S., Reet, N. V., Cnops, L., da Luz, R. I., Esbroeck, M. V., Kapandji, M., Matondo-Kuamfumu, M., Kiabanzawoko, O. N., et al. (2026) · BMC Infectious Diseases · doi:10.1186/s12879-026-12550-0 · Cited by 1
“A real-time PCR efficiency between 90 and 110% and R² > 0.98 is generally considered acceptable [32–34].”
InfluentialControl of chronic Epstein-Barr virus infection : consequences of altered B lymphocyte activation
Sanosyan, A. (2016) · theses.fr (ABES) · doi:10.70675/2c4c2972z2dadz4c2azbe8ezb99eee8ba41e
Electrochemical biosensing of circulating MicroRNAs in endometrial Cancer
Patel, N., Afzal, M., Mishra, R., Upadhya, S., Phalak, P., Pandey, S. N., Thakur, P., Shahwan, M., Kalra, A., & Mishra, R. (2026) · Clinica Chimica Acta · doi:10.1016/j.cca.2026.121002
Revolutionizing genomic medicine with artificial intelligence and data analytics
Patra, P. P. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-27638-5.00013-4
A LAMP‐Assay for the Detection and Genotyping of HPV Causing Plantar Warts From Skin Scrapes Samples
Aldana‐Caballero, A., Tejedor, F. M., Mayordomo, R., & van Marle, G. (2026) · Journal of Medical Virology · doi:10.1002/jmv.70975
Unlu, Y. S., & Tulum, I. (2026) · Australasian Plant Pathology · doi:10.1007/s13313-026-01155-5
“01.2 + 418) using the ggplot2 package for visualization, following the established guidelines for clinical microbiology and diagnostic validation (Burd 2010).”
InfluentialIntegrating HTS and CRISPR/Cas for next-generation nucleic and non-nucleic acid diagnostics
Mishra, M. K., Pamu, S., Guptha, P. M., Vanangamudi, M., Mittapalli, S. K., Dash, P. P., Thakor, V., Yanadaiah, P., & Patyar, S. (2026) · Molecular Genetics and Genomics · doi:10.1007/s00438-026-02468-2
“To ascertain that the optimised assay is accurate and reliable in detecting pathogens, genetic variants, and infectious diseases, an appropriate validation process using well-char-acterised samples is necessary (Burd 2010).”
Artificial intelligence in molecular diagnostics for pandemic preparedness
Sagar, K., Mukherjee, D., Savareh, B. A., Touré, C. T., Ceruti, A., Ghosh, P., Weidmann, M., Truyen, U., Wahed, A. A. E., & Kobialka, R. M. (2026) · Expert Review of Molecular Diagnostics · doi:10.1080/14737159.2026.2697900
Salazar, M. G. M., Picelli, A. M., da Silva, V. C. P. R., Bisneto, P. F., da Cruz, C. B. N., Carvalho, É. D. S., Alencar, R. M., Nascimento, T. P., Monteiro, W. M., Wen, F. H., et al. (2026) · Experimental and Molecular Pathology · doi:10.1016/j.yexmp.2026.105062
Bédard, O., Vallières, É., Vadboncoeur, J., Hamel, P., Lavallée, C., Lefebvre, B., Fafard, J., Lévesque, S., Bazet, M. A., Fortin, C., et al. (2026) · Microbiology Spectrum · doi:10.1128/spectrum.00701-26
“To ensure optimal laboratory practices, these tests can be used on specimens from other anatomical sites only after completion of a validation process, which includes performance analysis (15, 16).”
Validation of sample pooling for high-throughput RT-qPCR subtyping of avian influenza A(H5)
Higerd‐Rusli, G. P., Hoffman, S. A., Karan, A. M., Huang, C., Sahoo, M. K., Morante, I. E. A., Hernandez, M. M., & Pinsky, B. A. (2026) · Microbiology Spectrum · doi:10.1128/spectrum.00850-26
Jańczak, D., Kędziorek, J., Antecki, M., & Wesołowski, R. (2026) · Applied Sciences · doi:10.3390/app16147124
Cherney, B., Diaz, A., Ghattas, C., Gregory, M., Stow, E., Onyewuenyi, J., Kocherlakota, L. S., White, L., Vidyaprakash, E., Scott, S., et al. (2026) · Journal of Clinical Microbiology · doi:10.1128/jcm.00213-26
“I n c o m p l e t e u n d e r s t a n d i n g o f a ss a y p e r f o r m a n c e c a n t r a n s l a t e i n t o t h e r e p o r t i n g o f i n a cc u r a t e r e s u l t s .”
Su, Y., Zheng, Y. J., Zhou, J., Liu, B., Su, H., Yao, C., Qi, L., Wang, Y., Niu, Y., Mj, L., et al. (2026) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2026.140580
Sharma, S., Salaudeen, H. D., Ransom, E. M., VanEpps, J. S., & Yau, S. ‐. (2026) · Microbiology Spectrum · doi:10.1128/spectrum.00487-26
“We have conducted an analytical validation of the RDAP following the guidelines for laboratory-developed tests (14) (see supple mental material).”
Ko, S., Song, E., Stachnik, M., Collet, B., Gorgoglione, B., Lee, P., Yáñez, A. J., Jeong, J. B., Kim, K., Kim, Y., et al. (2026) · Aquaculture · doi:10.1016/j.aquaculture.2026.744469
Jacomasso, T., & Costa, A. D. T. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-40634-8.00030-1
Hsu, L.-C., Weng, Y., & Liu, W. (2026) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.70334
“Diagnostic performance can be influenced by spectrum effects, referral patterns, and disease severity distribution [27], particularly in febrile illnesses where hematologic abnormalities overlap across infections [28, 29].”
Clinical and Analytical Performance of the AP Biotech Discovery® Dengue Virus RT-PCR Detection Kit
Hjelt, V., Dronseck, A., Schey, A., Martí, M. B., Civerchia, L., Cavatorta, A. L., Codino, E., Nader, V., Garro, N. A., Aranda, F. M., et al. (2026) · Viruses · doi:10.3390/v18080914
Gauthier, N. P. G., Kapoor, V., Gaston, D. C., Prasad, N., Nwaobia, P., Kraft, C. S., & Mittar, D. (2026) · Journal of Clinical Microbiology · doi:10.1128/jcm.00987-26
“Existing quality frameworks, including CLSI guidance, CAP checklist expectations, and CLIA laboratory oversight, provide useful foundations for documentation, validation, competency, and reporting but do not fully address the agnostic and continuously evolving nature of mNGS diagnostics (50, 51).”
Yi, W., Luo, H., Luo, F., Li, Q., Huang, X., Yu, Q., Deng, G., & Liu, S. (2026) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2026.1949504
“Clinical translation still requires assessment of lot-to-lot stability and resistance to interference in complex specimens (Burd, 2010).”
Li, Y., Liu, F., Zhang, H., Peng, Z., Wang, Y., Liu, T., & Wang, Y. (2026) · Journal of Medical Biochemistry · doi:10.5937/jomb0-68184
“The corresponding 95% LoA were -12.34% to 12.65%, -14.93% to 14.37%, -11.36% to 9.50%, -10.11% to 11.72%, -15.35% to 14.20%, and -15.37% to 15.34%, respectively.”
InfluentialSaravanabhavan, S. S., & Vijayan, D. S. (2026) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2026.119157
Deep Learning-Based HSV-1 Detection Using Transfer Learning with MobileNetV2
Agrawal, P., Jain, A., & Gupta, P. (2026) · IEEE World Conference on Applied Intelligence and Computing (AIC) · doi:10.1109/aic70896.2026.11716895
“Attempting to obtain a clinical diagnosis is usually completed using a variety of methodologies, including the use of viral culture, serology and various molecular techniques (including PCR) [8][11].”
Gao, Z., Li, J., & Jiang, D. (2026) · Clinica Chimica Acta · doi:10.1016/j.cca.2026.122885
Santella, B., Donato, A., Satriani, V., Grumiro, L., Stracquadanio, S., Santoro, E., Fortino, L., Colosimo, C., Nicolosi, A., Calvo, M., et al. (2026) · Antibiotics · doi:10.3390/antibiotics15101012
“Such results should therefore be interpreted as discordant findings rather than simply as false-positive molecular results, especially when supported by selective culture verification [21].”
Son, E., Lee, S. Y., Lee, M.-J., Kang, S., Lee, S., & Lee, J. S. (2026) · Diagnostic Microbiology and Infectious Disease · doi:10.1016/j.diagmicrobio.2026.117692
Metadata
- Authors
- Burd, E. M.
- Affiliations
- Emory University Hospital (US)
- Corresponding author
- Burd, Eileen M.
- ORCID
- Burd, Eileen M.
- Venue
- Clinical Microbiology Reviews
- Publisher
- American Society for Microbiology
- Published
- 2010-07
- Volume
- 23
- Issue
- 3
- Pages
- 550-576
- ISSN
- 0893-8512 (ISSN-L)
- 1098-6618
- PMC
- PMC2901657
- OpenAlex
- W2096278562
- Cited by
- 550
- References
- 48
- Citations by year
- 2026: 30 · 2025: 43 · 2024: 36 · 2023: 42 · 2022: 42 · 2021: 41 · 2020: 38 · 2019: 36 · 2018: 39 · 2017: 37 · 2016: 44 · 2015: 35 · 2014: 32 · 2013: 21 · 2012: 18
- FWCI
- 1.74
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- journals.asm.org/non-commercial-tdm-license (tdm)
- Locations
- Clinical Microbiology Reviews (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Medicine › Microbiology (medical) › Bacterial Identification and Susceptibility Testing
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Healthcare Regulation
- Keywords
- laboratory-developed tests, molecular diagnosis, infectious diseases, assay validation, analytical sensitivity, analytical specificity, precision and accuracy, reference values, assay modification
- MeSH terms
- Communicable Diseases, Humans, Clinical Laboratory Techniques, Molecular Diagnostic Techniques, Validation Studies as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.