Validation of Laboratory-Developed Molecular Assays for Infectious Diseases
Open accessThe DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Abstract
SUMMARY: Molecular technology has changed the way that clinical laboratories diagnose and manage many infectious diseases. Excellent sensitivity, specificity, and speed have made molecular assays an attractive alternative to culture or enzyme immunoassay methods. Many molecular assays are commercially available and FDA approved. Others, especially those that test for less common analytes, are often laboratory developed. Laboratories also often modify FDA-approved assays to include different extraction systems or additional specimen types. The Clinical Laboratory Improvement Amendments (CLIA) federal regulatory standards require clinical laboratories to establish and document their own performance specifications for laboratory-developed tests to ensure accurate and precise results prior to implementation of the test. The performance characteristics that must be established include accuracy, precision, reportable range, reference interval, analytical sensitivity, and analytical specificity. Clinical laboratories are challenged to understand the requirements and determine the types of experiments and analyses necessary to meet the requirements. A variety of protocols and guidelines are available in various texts and documents. Many of the guidelines are general and more appropriate for assays in chemistry sections of the laboratory but are applied in principle to molecular assays. This review presents information that laboratories may consider in their efforts to meet regulatory requirements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Implementation of mNGS in the clinical laboratory is a complex endeavour that requires customization of research protocols using a quality management approach consistent with regulatory standards90.”
From Clinical metagenomics (2019) · cites this paper as [90]
In the citing paper
“Clinical laboratories are highly regulated, and general laboratory and testing requirements apply to all molecular diagnostic assays reported for patient care90.”
From Clinical metagenomics (2019) · cites this paper as [90]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
International Organization for Standardization
(2015) · Encyclopedia of Astrobiology · doi:10.1007/978-3-662-44185-5_100574 · Cited by 6,716
Tietz Textbook of Clinical Chemistry
(1999) · Archives of Pathology and Laboratory Medicine · doi:10.5858/123.7.646b · Cited by 2,495
Thompson, M., Ellison, S. L. R., & Wood, R. (2002) · Pure and Applied Chemistry · doi:10.1351/pac200274050835 · Cited by 2,478
Real-Time PCR in Clinical Microbiology: Applications for Routine Laboratory Testing
Espy, M. J., Uhl, J. R., Sloan, L. M., Buckwalter, S. P., Jones, M. F., Vetter, E. A., Yao, J. D. C., Wengenack, N. L., Rosenblatt, J. E., Cockerill, F. R., et al. (2006) · Clinical Microbiology Reviews · doi:10.1128/cmr.19.1.165-256.2006 · Cited by 1,318
Highly sensitive real-time PCR for specific detection and quantification of Coxiella burnetii
Klee, S. R., Tyczka, J., Ellerbrok, H., Franz, T., Linke, S., Baljer, G., & Appel, B. (2006) · BMC Microbiology · doi:10.1186/1471-2180-6-2 · Cited by 323
Saah, A. J., & Hoover, D. R. (1997) · Annals of Internal Medicine · doi:10.7326/0003-4819-126-1-199701010-00026 · Cited by 269
Recommended Principles and Practices for Validating Clinical Molecular Pathology Tests
Jennings, L., Van Deerlin, V. M., & Gulley, M. L. (2009) · Archives of Pathology & Laboratory Medicine · doi:10.5858/133.5.743 · Cited by 250
Use of Bacteriophage MS2 as an Internal Control in Viral Reverse Transcription-PCR Assays
Dreier, J., Störmer, M., & Kleesiek, K. (2005) · Journal of Clinical Microbiology · doi:10.1128/jcm.43.9.4551-4557.2005 · Cited by 220
Research works printed but not linked: 16
- Code of Federal Regulations. 2010. Title 21. Food and drugs, vol. 8, chapter 1. Food and Drug Administration, Department of Health and Human Services, part 56. Institutional review boards. U.S. Government Printing Office, Washington, DC.
- Code of Federal Regulations. 2010. Title 21. Food and drugs, vol. 8, chapter 1. Food and Drug Administration, Department of Health and Human Services, part 864. Hematology and pathology devices, section 864.4020. Analyte specific reagents. U.S. Government Printing Office, Washington, DC.
- Code of Federal Regulations. 2010. Title 21. Food and drugs, vol. 8, chapter 1. Food and Drug Administration, Department of Health and Human Services, part 807. Establishment registration and device listing for manufacturers and initial importers of devices. U.S. Government Printing Office, Washington, DC.
- Code of Federal Regulations. 2010. Title 21. Food and drugs, vol. 8, chapter 1. Food and Drug Administration, Department of Health and Human Services, part 809. In vitro diagnostic products for human use, section 809.10. Labeling for in vitro diagnostic products. U.S. Government Printing Office, Washington, DC.
- Code of Federal Regulations. 2010. Title 21. Food and drugs, vol. 8, chapter 1. Food and Drug Administration, Department of Health and Human Services, part 809. In vitro diagnostic products for human use, section 809.20. General requirements for manufacturers and producers of in vitro diagnostic products. U.S. Government Printing Office, Washington, DC.
- Code of Federal Regulations. 2010. Title 21. Food and drugs, vol. 8, chapter 1. Food and Drug Administration, Department of Health and Human Services, part 809. In vitro diagnostic products for human use, section 809.30. Restrictions on the sale, distribution and use of analyte specific reagents. U.S. Government Printing Office, Washington, DC.
- Code of Federal Regulations. 2010. Title 21. Food and drugs, vol. 8, chapter 1. Food and Drug Administration, Department of Health and Human Services, part 812. Investigational device exemptions. U.S. Government Printing Office, Washington, DC.
- Code of Federal Regulations. 2010. Title 21. Food and drugs, vol. 8, chapter 1. Food and Drug Administration, Department of Health and Human Services, part 820. Quality system regulation. U.S. Government Printing Office, Washington, DC.
- Code of Federal Regulations. 2009. Title 42. Public health, vol. 4, chapter V. Health Care Financing Administration, Department of Health and Human Services, part 493. Laboratory requirements, section 493.1455. Standard: clinical consultant qualifications. U.S. Government Printing Office, Washington, DC.
- Code of Federal Regulations. 2009. Title 42. Public health, vol. 4, chapter V. Health Care Financing Administration, Department of Health and Human Services, part 493. Laboratory requirements, section 493.2. Definitions. U.S. Government Printing Office, Washington, DC.
- Code of Federal Regulations. 2009. Title 42. Public health, vol. 4, chapter V. Health Care Financing Administration, Department of Health and Human Services, part 493. Laboratory requirements, section 493.1253. Standard: establishment and verification of performance specifications. U.S. Government Printing Office, Washington, DC.
- Code of Federal Regulations. 2009. Title 42. Public health, vol. 4, chapter V. Health Care Financing Administration, Department of Health and Human Services, part 493. Laboratory requirements, section 493.1255. Standard: calibration and calibration verification procedures. U.S. Government Printing Office, Washington, DC.
- Code of Federal Regulations. 2009. Title 42. Public health, vol. 4, chapter V. Health Care Financing Administration, Department of Health and Human Services, part 493. Laboratory requirements, section 493.1256. Standard: control Procedures. U.S. Government Printing Office, Washington, DC.
- Code of Federal Regulations. 2009. Title 42. Public health, vol. 4, chapter V. Health Care Financing Administration, Department of Health and Human Services, part 493. Laboratory requirements, section 493.1282. Standard: corrective actions. U.S. Government Printing Office, Washington, DC.
- Social Security Act. Section 1862(a) (1), exclusions from coverage and Medicare as a second payer, now codified as Title 42, chapter 7, exclusions from coverage and Medicare as a second payer, U.S. Code. U.S. House of Representatives, Washington, DC.
- U.S. Department of Health and Human Services, Centers for Medicare and Medicaid Services. 1992. Clinical laboratory improvement amendments of 1988 (CLIA). Fed. Regist. 57:7002-7186. [PubMed] [Google Scholar]
Cited by
Items 401–500 of 550
Mozioğlu, E., Hussels, M., & Engel, S. (2024) · Diagnostic Microbiology and Infectious Disease · doi:10.1016/j.diagmicrobio.2024.116567 · Cited by 2
Advances in Molecular Technologies and Platforms for the Diagnosis of Infectious Diseases
Hasan, M. R. (2013) · Advanced materials research · doi:10.4028/www.scientific.net/amr.810.77 · Cited by 2
“However, these assays need to be standardized and validated adequately based on published recommendations and Clinical and Laboratory Standard Institute (CLSI) guidelines [101].”
MethodLeptospira Diagnosis in Serum and Urine of Dogs by Real Time PCR
Quintana, M. R. S. (2015) · Journal of Veterinary Science & Medical Diagnosis · doi:10.4172/2325-9590.1000157 · Cited by 2
Méthodes moléculaires et automatisation en microbiologie
Herrmann, J. (2016) · Revue Francophone des Laboratoires · doi:10.1016/s1773-035x(16)30170-8 · Cited by 2
Templar, A., Schofield, D. M., & Nesbeth, D. (2016) · Biomolecular Detection and Quantification · doi:10.1016/j.bdq.2016.12.001 · Cited by 2
Külkamp‐Guerreiro, I. C., Davies, S., Guterres, S. S., & Berlitz, S. J. (2019) · Drug Analytical Research · doi:10.22456/2527-2616.82578 · Cited by 2
McCloskey, C. B., & Dunn, S. T. (2012) · Springer eBooks · doi:10.1007/978-1-4614-2170-2_3 · Cited by 2
Good Cell Culture Practice (GCCP)
OECD (2018) · OECD series on testing and assessment · doi:10.1787/9789264304796-16-en · Cited by 4
Test and reference/control items
OECD (2018) · OECD series on testing and assessment · doi:10.1787/9789264304796-11-en · Cited by 2
Khan, I. A., Ali, I. I., Khan, S., & Ahmed, S. (2022) · Advanced Gut & Microbiome Research · doi:10.1155/2022/5143833 · Cited by 2
“We have painstakingly developed a TaqManTM assay on the OpenArrayTM platform, with a resistance option for rapid detection and speciation of fungi and bacteria most commonly observed to harm the foot and nails [6, 7].”
MethodCENTRO DE INVESTIGACIÓN EN ABEJAS SOCIALES - CIAS
Apicola, S. (2015) · Cited by 2
Saremi, M., Alebouyeh, M., & Owlia, P. (2020) · Jundishapur Journal of Microbiology · doi:10.5812/jjm.98035 · Cited by 2
“This measurement was done as described by Tawe (13) and Burd (14).”
MethodLuchetta, J., Bennett, W. N., V, Solis, L., Wicker, J., Joshi, V., Omballa, V., & Turnbull, L. B. (2025) · doi:10.12688/verixiv.678.1 · Cited by 2
Manufacturing and Control of Viral‐Vector Vaccines
Chavda, V. P., Vaghela, D. A., Barman, D., Newar, A., & Ahmed, N. (2025) · Wiley eBooks · doi:10.1002/9781394271566.ch8 · Cited by 3
da Rocha, A. C. A., Rodrigues, G. M., Hellwig, A. H. D. S., Pereira, D. C., Volpato, F. C. Z., Barth, A. L., & de Paris, F. (2025) · Diagnostics · doi:10.3390/diagnostics15020214 · Cited by 1
Andrea, M., Pugliese, M., Valfrè, P., & Canfora, L. (2025) · Biological Control · doi:10.1016/j.biocontrol.2025.105723 · Cited by 1
Development of a Multiplex Real-Time PCR for Diagnosis of Tuberculosis and Multidrug Resistance
Arı, O., Durmaz, R., Vezir, S., & Arslantürk, A. (2025) · Current Microbiology · doi:10.1007/s00284-025-04196-z · Cited by 3
“Performance tests of the designed PCR assay were carried out in accordance with the recommendations of the Laboratory Standard Institute (CLSI) [15–17].”
A pooled testing strategy for enterovirus D68 to facilitate local, resource-conserving surveillance
Spradley, M. E., Williams, T., McHenry, R. E., Short, L. L., Nelson, D. J., Chappell, J. D., Halasa, N., Haselton, F. R., & Schmitz, J. E. (2025) · Diagnostic Microbiology and Infectious Disease · doi:10.1016/j.diagmicrobio.2025.116934 · Cited by 1
“With this strategy, we foresee the largest benefit for local epidemiologic surveillance, although a two-step algorithm could also be utilized for patient-level EV-D68 diagnoses (requiring validation in accordance with local regulations for on-site developed diagnostics [25]).”
Amini‐Bavil‐Olyaee, S., & Pourkarim, M. R. (2012) · Hepatitis Monthly · doi:10.5812/hepatmon.6155 · Cited by 1
Molecular Pathology Laboratory Management
Rennert, H., & Leonard, D. G. B. (2016) · Springer eBooks · doi:10.1007/978-3-319-19674-9_62 · Cited by 1
Templar, A., Marsh, D., & Nesbeth, D. (2016) · SpringerPlus · doi:10.1186/s40064-016-3074-8 · Cited by 1
“Method comparison by XY plot (Burd 2010) gives a slope of 1.”
BackgroundMethodInfluentialPitfalls of viral load testing
Higgins, G. (2010) · Microbiology Australia · doi:10.1071/ma10119 · Cited by 1
First Principles of Clinical Microbiology: Collection, Handling, and Diagnostics
Bachman, M. A., & LeBar, W. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-801238-3.66116-0 · Cited by 3
Tataje‐Lavanda, L., Huamán-Gutiérrez, K., Bobadilla, V. L., López, G., Nolasco, O., Bendezú, J., & Fernández‐Díaz, M. (2018) · Journal of Veterinary Science & Technology · doi:10.4172/2157-7579.1000543 · Cited by 1
“Precision was defined as the reproducibility of ILTV gene copy number; diagnostic specificity as the absence of impurities (closely related structural components); LoB as the highest fluorescence apparent signal of the ILTV gene found in replicates of a DNA material without target sequences of the ILTV gene; LoD was d…”
BackgroundMethodStandardisation and accreditation bodies
OECD (2018) · OECD series on testing and assessment · doi:10.1787/9789264304796-20-en · Cited by 1
OECD (2018) · OECD series on testing and assessment · doi:10.1787/9789264304796-6-en · Cited by 1
Shabbir, S., Ali, N., Iftikhar, A., Khurshid, A., Rao, M. F. S., Hussain, S., & Rizwan, M. (2022) · Pakistan Journal of Medical and Health Sciences · doi:10.53350/pjmhs221610804 · Cited by 1
Aston, D., Besser, M. W., Goddard, B., Maggs, N., Ahmed, H. M., & Falter, F. (2022) · Clinical and Applied Thrombosis/Hemostasis · doi:10.1177/10760296221148162 · Cited by 2
“Due to the exploratory nature of this investigation and the lack of any previous data to inform sample size calculation we obtained guidance from the laboratory literature.(12) The paired POC and laboratory APRs were evaluated for their degree of agreement.”
MethodSchilhabel, A., Szczepanowski, M., van Gastel-Mol, E. J., Schillalies, J., Ray, J., Kim, D. S., Nováková, M., Dombrink, I., van der Velden, V. H. J., Böettcher, S., et al. (2023) · Frontiers in Oncology · doi:10.3389/fonc.2022.1111209 · Cited by 1
Tosun, A. İ., Kolukırık, M., Yılmaz, M., Ötgün, S. N., Aygün, G., Kolukirik, C. Z. K., Zeybek, Ü., Ozgumus, G. G., Turan, M., Kuşkucu, M. A., et al. (2023) · Journal of Microbiological Methods · doi:10.1016/j.mimet.2023.106690 · Cited by 1
Aijaz, J., Khan, J., Naseer, F., Kumar, D., & Hussain, S. (2023) · Practical Laboratory Medicine · doi:10.1016/j.plabm.2023.e00326 · Cited by 1
“A CV of more than 15% was considered unacceptable [14], while a p-value of less than 0.”
BackgroundAccuracy of Expired BinaxNOW Rapid Antigen Tests
Vaeth, M. J. E., Abdullah, O. R., Cheema, M., Sun, K. J., Elhabashy, M., Mitchell, A., Foyez, M., Talla, M., Cheema, A., Locke, C. F. S., et al. (2023) · Microbiology Spectrum · doi:10.1128/spectrum.02088-23 · Cited by 1
“The expiration dates for COVID-19 rapid antigen tests were initially determined based on accelerated stability studies, which are commonly used to estimate the shelf life of diagnostic products (10).”
MethodTranslational and clinical applications of the GeoMx digital spatial profiling platform
Church, S., Perez, J., Murphy, B., Sato, H., Warren, S. E., & Beechem, J. (2023) · Elsevier eBooks · doi:10.1016/b978-0-12-822824-1.00034-1 · Cited by 2
Tao, L., Chan, A., Maris, A. S., & Schmitz, J. E. (2024) · Influenza and Other Respiratory Viruses · doi:10.1111/irv.13207 · Cited by 1
“15 Analytically, moreover, C t -values can vary considerably on the same specimen when analyzed across different testing platforms.”
BackgroundInfluentialSARS-CoV-2 Variants Genotyping and Diagnostic Performance of a 2-Genes Detection Assay
Matheka, C., Kilonzo, J., Mbugua, E., Munshi, Z., Nyasinga, J., Revathi, G., & Njau, A. N. (2024) · The Journal of Applied Laboratory Medicine · doi:10.1093/jalm/jfad127 · Cited by 1
Tan, W., & Ward, M. P. (2024) · Australian Veterinary Journal · doi:10.1111/avj.13376 · Cited by 1
Pelier, C. V. R., Téllez, G. M., Rives, B. T., Rosales, Y. Z., Alexis, A. G., & Perera, A. M. (2013) · Revista Habanera de Ciencias Médicas · Cited by 1
Clinical Relevance of Molecular Microbiology
Gupte, S. (2016) · Journal of Human Virology & Retrovirology · doi:10.15406/jhvrv.2016.03.00107 · Cited by 1
“Clinical application: Allow subtype differentiation of bacterial isolates beyond the species and subspecies levels [9].”
BackgroundNonspecific Amplification of Human DNA by Streptococcus pneumoniae LytA Primer
Thangamony, H. H., Kumar, R., Thangavelu, C. P., Mani, M., Grace, V. M. B., & Brahmadathan, K. N. (2018) · Indian Journal of Medical Microbiology · doi:10.4103/ijmm.ijmm_17_342 · Cited by 2
“Optimisation of such tests starts with the validation of selected primers by delineating various test characteristics including analytical specificity and sensitivity.[1] Normally, the specificity of the chosen primers is determined by testing them against genetically related and unrelated microbial pathogens as well…”
BackgroundVerbeke, H., Dierick, A. M., Ghislain, V., Coucke, W., & Soumali, M. R. (2019) · Accreditation and Quality Assurance · doi:10.1007/s00769-019-01418-3 · Cited by 1
Verification of a rapid von Willebrand factor propeptide assay
Maleka, R. B., & Meiring, M. (2020) · Journal of Medical Laboratory Science & Technology of South Africa · doi:10.36303/jmlstsa.2020.2.2.47 · Cited by 1
Li, J., Wang, M., Jia, R., Ma, Z., Zhang, X., Li, J., Xiao, X., Zhou, Y., & Wang, Q. (2022) · Magnetochemistry · doi:10.3390/magnetochemistry8040041 · Cited by 1
“Even for confirmed patients, the highest positivity rate is only 30% to 60%, and a large number of patients have always been “false negatives” [6].”
BackgroundStorage and retention of records and materials
OECD (2018) · OECD series on testing and assessment · doi:10.1787/9789264304796-15-en · Cited by 1
General Aspects of Molecular Diagnostics
Leber, A. L. (2016) · ASM Press eBooks · doi:10.1128/9781555818814.ch12.2.1 · Cited by 1
Zhao, Y., Kontoyiannis, D. P., Roilides, E., Walsh, T. J., & Perlin, D. S. (2014) · Journal of Clinical Microbiology · doi:10.1128/jcm.01711-14 · Cited by 1
Molecular Tests for the Identification of Viruses
Duong, S., & Ginocchio, C. C. (2016) · Wiley eBooks · doi:10.1002/9781119021872.ch6 · Cited by 1
Sunohara-Neilson, J. (2013) · The Atrium (University of Guelph) · Cited by 1
White, S., Tchuenkam, V. P. K., Mbouh, M., Gaither, C., Bouopda-Tuedom, A. G., Kiam, B. C., Popkin-Hall, Z. R., Sadler, J. M., Carey-Ewend, K., Hand, E., et al. (2025) · medRxiv · doi:10.1101/2025.04.28.25326551 · Cited by 1
“To determine the limit of detection (LOD) for the P. ovale spp. gametocyte assay, probit analysis was conducted on replicate rt-qPCR runs using templates with known copy number concentrations (48).”
Selection of Nucleic Acid Amplification Systems
Starolis, M. W. (2025) · Wiley eBooks · doi:10.1002/9781683674597.ch14 · Cited by 1
Robinson, D. R., Pennisi, I., Cavuto, M. L., Kiemdé, F., Chamai, M., Some, D. Y., Quigley, E., Malpartida-Cardenas, K., Ndiath, M. O., Correa, S., et al. (2025) · medRxiv · doi:10.1101/2025.07.12.25331425 · Cited by 1
Validation of PCR assays for detection of Shiga toxin-producing E. coli O104:H4 and O121 in food
Tawe, J. (2014) · KTH Publication Database DiVA (KTH Royal Institute of Technology) · Cited by 1
Quality Assurance for Molecular Diagnostic Laboratories
Burd, E. M., Wang, J., & Hill, C. E. (2014) · Elsevier eBooks · doi:10.1016/b978-0-12-386456-7.07710-8
Self-citationJúnior, M. C. R. (2014) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/t.60.2014.tde-17042015-143833 · Cited by 1
Múnera, M. I., Ramírez-Puerta, B. S., Ávila, S. M. C., & Rojas-Ríos, R. (2012) · Infectio · doi:10.1016/s0123-9392(12)70052-8
Research findings: What utility managers need to know
Speight, V. L. (2012) · American Water Works Association · doi:10.5942/jawwa.2012.104.0010
Regulation of laboratory-developed diagnostic assays: Where we are
Bansal, N. (2011) · Clinical Research and Regulatory Affairs · doi:10.3109/10601333.2011.597761
“Moreover these diagnostic assays have made detection of many diseases faster and easier, which would otherwise take a long time for detection due to slow growth or difficulty in growing cultures (2).”
BackgroundPadlock Probe-Based Assays for Molecular Diagnostics
Mezger, A. (2015) · DiVA (Stockholm University)
Laboratory management: Quality assurance and inspection
Post, K. M., & Liang Cheng, C. (2013) · doi:10.1007/978-1-4614-4800-6-46
General Principles of Validating a Molecular Test
Dumur, C. I. (2015) · Springer eBooks · doi:10.1007/978-3-319-16304-8_6
Gurman, P. (2017) · Cambridge University Press eBooks · doi:10.1017/9781316084304.012
Medical Devices: Other Considerations
Hunter, T. B., Taljanovic, M. S., & Wild, J. R. (2017) · Cambridge University Press eBooks · doi:10.1017/9781316084304.009
Non-Infectious Stabilized MS2 Virus As a Universal Full-Process Molecular Control
McGlynn, K. E. (2014)
Nshimyimana, J. P. (2017) · DR-NTU (Nanyang Technological University) · doi:10.32657/10356/72263 · Cited by 2
Desenvolvimento de uma plataforma molecular para detecção de Mycoplasma spp. em culturas celulares
de Macedo, M. D. (2014) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/d.60.2014.tde-17042015-144258 · Cited by 2
The diagnostic molecular pathology of colorectal carcinoma using automated PCR
Colling, R. T. (2017) · UCL Discovery (University College London)
Ranjbar, R., & Afshar, D. (2017) · Archives of Pediatric Infectious Diseases · doi:10.5812/pedinfect.61604
An Agile Quality Management System For Laboratory Developed Tests
D'Angelo, R. Y. (2018) · Human Biology
Fletcher, G. J., Anantharam, R., Radhakrishnan, K., Singh, U., Karunakaran, A., Jeyaseelan, V., & Abraham, P. (2018) · Journal of Immunoassay and Immunochemistry · doi:10.1080/15321819.2018.1529680
“Analytical sensitivity was calculated by Probit analysis.([12]) Within laboratory precision (intra and inter) was calculated by estimating the CV%.”
MethodSaid, R., & Tsimberidou, A. M. (2015) · Wiley eBooks · doi:10.1002/9781118468678.ch37
Domingues, W. (2019) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/t.99.2019.tde-20022019-093808
Update in the Molecular Diagnostics of Sexually Transmitted Infections
Paxton, R. J., Munson, E. L., & Barta, K. (2019) · Physician Assistant Clinics · doi:10.1016/j.cpha.2019.02.003
Assessment of Lysenow® Perforated Card on Preservation of Dengue Virus RNA in Whole Blood
Lee, C.-R. R., Chen, H., Defang, G. N., & Wu, S.-J. L. (2019) · Annals of Microbiology and Infectious Diseases · doi:10.22259/2637-5346.0202003
Wankhede, G., Mundhada, S., Desai, S., & Dakhave, M. (2019) · Global Journal of Transfusion Medicine · doi:10.4103/gjtm.gjtm_54_19
“As per the manufacturer, the performance characteristics of the NATSpert ID TripleH Detection assay have been determined using NIBSC WHO standards for infectious Diseases.”
MethodShaik, A. H., Govindan, V., Nagaraj, G., & Ravikumar, K. L. (2019) · Journal of Applied Biology & Biotechnology · doi:10.7324/jabb.2019.70503
Diagnostic testing for swine respiratory viruses using oral fluids in Saskatchewan
Kulanayake, S. (2016) · HARVEST (University of Saskatchewan)
Development of a Novel Cytochrome b Real-Time PCR Assay for Identification of Plasmodium malariae
Hang, D. T. T., Nga, V. T., Tong, H. V., Su, H. X., Tuấn, L. Q., Chuyên, N. V., Trinh, N. T. M., & Sơn, H. A. (2020) · VNU Journal of Science Medical and Pharmaceutical Sciences · doi:10.25073/2588-1132/vnumps.4233
Jovičić, S. M. (2020) · medRxiv · doi:10.1101/2020.10.02.20205823
“All conditions should be stable and quality control samples should be used to minimize false results, taking into the account diverse influencing factors [26].”
BackgroundSevere acute respiratory syndrome coronavirus 2 (SARS CoV-2) detection pitfalls
Goldschmidt, P. L. (2021) · International Journal of Science and Research Archive · doi:10.30574/ijsra.2021.2.2.0049
“000 copies/ml for one of the antigen point of care tests [43], [44), [45].”
BackgroundUnbiased Pandemic Pathogen Detection and the Federal Register
Greninger, A. L. (2021) · Journal of Clinical Microbiology · doi:10.1128/jcm.01346-21
“Establishing performance characteristics of a diagnostic assay prior to its execution is a requirement in the United States either for Food and Drug Administration (FDA) authorization or under the Clinical Laboratory Improvements Amendments (CLIA) (5).”
MethodMolecular Detection of Blueberry Stunt Phytoplasma in Eastern Canada: a Multi-year StudyPreprint
Hammond, C., Pérez‐López, E., Town, J. R., Vincent, C., Moreau, D. L., & Dumonceaux, T. (2021) · Research Square · doi:10.21203/rs.3.rs-668203/v1
Definition of “Tissue-Based Biomarker,” its Place in Medicine, and Molecular Pathology
Sağol, Ö., & Sarıoğlu, S. (2022) · Springer eBooks · doi:10.1007/978-3-030-84432-5_1
Pusterla, N., Leutenegger, C. M., Crossley, B. M., & Hietela, S. (2020) · Elsevier eBooks · doi:10.1016/b978-0-323-55445-9.00029-x
Cerf–Bensussan, N. (2019) · Faculty Opinions – Post-Publication Peer Review of the Biomedical Literature · doi:10.3410/f.726760263.793561381
Favacho, J. D. F. R., Leite, K. K., Gomes, S. T. M., Mota, G. D., Mesquita, M. D. P. M., Schluga, P. H. D. C., Tassi, W., Jacomasso, T., Farias, A. B., Rampazzo, . D. C. P., et al. (2019) · Research Square · doi:10.21203/rs.2.11147/v1
“The 95% limit of detection (LOD95%) for detection of the Chlamydia genomic target was calculated by Probit regression analysis[25].”
MethodOECD (2018) · OECD series on testing and assessment · doi:10.1787/9789264304796-14-en
List of viability testing methods (non-inclusive) of cell cultures
OECD (2018) · OECD series on testing and assessment · doi:10.1787/9789264304796-24-en · Cited by 1
Костюк, С. А., & Poluyan, O. S. (2021) · Лабораторная диагностика Восточная Европа · doi:10.34883/pi.2020.9.4.002 · Cited by 1
Research findings: What utility managers need to know
Speight, V. L. (2012) · American Water Works Association · doi:10.5942/jawwa.2013.105.0007
“Ideally, the limit of detection (LOD) should be reported where it is defined as the lowest target concentration at which positive detection occurs with ≥ 95% probability (Burd, 2010).”
Костюк, С. А., & Poluyan, O. S. (2020) · Лабораторная диагностика Восточная Европа · doi:10.34883/pi.2020.9.3.012
OECD (2018) · OECD series on testing and assessment · doi:10.1787/9789264304796-13-en
Apparatus, material and reagents
OECD (2018) · OECD series on testing and assessment · doi:10.1787/9789264304796-9-en
OECD GIVIMP meeting 23-24 March, 2017 - participating experts
OECD (2018) · OECD series on testing and assessment · doi:10.1787/9789264304796-19-en
OECD (2018) · OECD series on testing and assessment · doi:10.1787/9789264304796-8-en
Laboratory Management: Quality Assurance and Inspection
Post, K. M., & Liang Cheng, C. (2012) · Springer eBooks · doi:10.1007/978-1-4614-4800-6_46
Sharma, P., Batheja, G., Verma, H. N., & Seth, P. (2022) · Research Square · doi:10.21203/rs.3.rs-1666885/v1
Sharma, P., Batheja, G., Verma, H. N., & Seth, P. (2022) · Research Square · doi:10.21203/rs.3.rs-1708998/v1
Moragas, M., Golemba, M. D., Fernández, M. F., Palladino, M., Gómez, S., Borgnia, D., Ruhle, M., Arias, A., Ruvinsky, S., Bologna, R., et al. (2023) · Brazilian Journal of Microbiology · doi:10.1007/s42770-023-01009-y
Metadata
- Authors
- Burd, E. M.
- Affiliations
- Emory University Hospital (US)
- Corresponding author
- Burd, Eileen M.
- ORCID
- Burd, Eileen M.
- Venue
- Clinical Microbiology Reviews
- Publisher
- American Society for Microbiology
- Published
- 2010-07
- Volume
- 23
- Issue
- 3
- Pages
- 550-576
- ISSN
- 0893-8512 (ISSN-L)
- 1098-6618
- PMC
- PMC2901657
- OpenAlex
- W2096278562
- Cited by
- 550
- References
- 48
- Citations by year
- 2026: 30 · 2025: 43 · 2024: 36 · 2023: 42 · 2022: 42 · 2021: 41 · 2020: 38 · 2019: 36 · 2018: 39 · 2017: 37 · 2016: 44 · 2015: 35 · 2014: 32 · 2013: 21 · 2012: 18
- FWCI
- 1.74
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- journals.asm.org/non-commercial-tdm-license (tdm)
- Locations
- Clinical Microbiology Reviews (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Medicine › Microbiology (medical) › Bacterial Identification and Susceptibility Testing
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Healthcare Regulation
- Keywords
- laboratory-developed tests, molecular diagnosis, infectious diseases, assay validation, analytical sensitivity, analytical specificity, precision and accuracy, reference values, assay modification
- MeSH terms
- Communicable Diseases, Humans, Clinical Laboratory Techniques, Molecular Diagnostic Techniques, Validation Studies as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.