Is self-monitoring of blood glucose effective in improving glycaemic control in type 2 diabetes without insulin treatment: a meta-analysis of randomised controlled trials
Open accessThe DOI matches its Crossref record; 39 of the 42 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: The present study aimed to verify the effectiveness of self-monitoring of blood glucose (SMBG) in patients with non-insulin-treated type 2 diabetes (T2D). METHODS: A comprehensive literature search was conducted in PubMed, Cochrane Library, Web of Science, ScienceDirect and ClinicalTrials.gov from their respective inception dates to 26 October 2015. Eligible randomised controlled trials (RCTs) were included according to prespecified criteria. The quality of the included RCTs was evaluated according to the Cochrane risk of bias tool, and the evidence quality of meta-analyses was assessed by the Grading of Recommendation, Assessment, Development, and Evaluation (GRADE) criteria. A meta-analysis of primary and secondary outcome measures was performed. Sensitivity and subgroup analyses were carried out to evaluate the robustness and heterogeneity of the findings. Begg's and Egger's tests were used to quantify publication biases. RESULTS: A total of 15 RCTs, comprising 3383 patients with non-insulin-treated T2D, met the inclusion criteria. The SMBG intervention improved glycated haemoglobin (HbA1c) (mean difference -0.33; 95% CI -0.45 to -0.22; p=3.0730e-8; n=18), body mass index (BMI; -0.65; -1.18 to -0.12; p=0.0164; n=9) and total cholesterol (TC; -0.12; -0.20 to -0.04; p=0.0034; n=8) more effectively than the control in overall effect. The sensitivity analysis revealed little difference in overall effect, indicating the robustness of the results. SMBG moderated HbA1c levels better than the control in all subgroup analyses. Most of the RCTs had high risk of bias in blinding, while the overall quality of evidence for HbA1c was moderate according to the GRADE criteria. Publication bias was moderate for BMI. CONCLUSIONS: SMBG improved HbA1c levels in the short term (≤6-month follow-up) and long term (≥12-month follow-up) in patients with T2D who were not using insulin. TRIAL REGISTRATION NUMBER: CRD42015019099.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures



Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“A meta-analysis including people with non–insulin-treated type 2 diabetes showed that blood glucose monitoring is associated with a reduction in glycated haemoglobin by 0.3%,5”
From Blood glucose monitoring devices: current considerations (2023) · cites this paper as [5]
The cited source says what the claim attributes to it.
In the citing paper
“In comparison to three major meta-analyses of SMBG RCTs published in the past decade (17, 29, 31), the current review identified six studies not previously incorporated ( Supplementary Table S5 ).”
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“Furthermore, previous reviews have paid little attention to the impact of sSMBG on treatment modification, behavioral outcomes (i.e. self-care) or psychosocial outcomes (e.g. self-efficacy, treatment satisfaction, well-being, quality of life) (17, 29, 31).”
From The impact of structured self-monitoring of blood glucose on clinical, behavioral, and psychosocial outcomes among adults with non-insulin-treated type 2 diabetes: a systematic review and meta-analysis (2023) · cites this paper as [31]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bias in meta-analysis detected by a simple, graphical test
Egger, M., Smith, G. D., Schneider, M., & Minder, C. (1997) · BMJ · doi:10.1136/bmj.315.7109.629 · Cited by 56,722
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667
Dermyshi, E., Wang, Y., Yan, C., Hong, W., Qiu, G., Gong, X., & Zhang, T. (2017) · Neonatology · doi:10.1159/000454668 · Cited by 24,451
Conducting Meta-Analyses in R with the metafor Package
Viechtbauer, W. (2010) · Journal of Statistical Software · doi:10.18637/jss.v036.i03 · Cited by 20,464
Operating characteristics of a rank correlation test for publication bias
Begg, C. B., & Mazumdar, M. (1994) · Biometrics · doi:10.2307/2533446 · Cited by 16,955
PROSPERO: an international prospective register of systematic reviews
Wright, K. E. (2014) · Cited by 568
Farmer, A., Wade, A., Goyder, E., Yudkin, P., French, D., Craven, A., Holman, R., Kinmonth, A.-L., & Neil, A. (2007) · BMJ · doi:10.1136/bmj.39247.447431.be · Cited by 407
Self-monitoring of blood glucose in patients with type 2 diabetes mellitus who are not using insulin
Malanda, U. L., Welschen, L. M., Riphagen, I. I., Dekker, J. M., Nijpels, G., & Bot, S. D. (2012) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd005060.pub3 · Cited by 358
Cummins, E., Royle, P., Snaith, A., Greene, A., Robertson, L., McIntyre, L., & Waugh, N. (2010) · Health Technology Assessment · doi:10.3310/hta14110 · Cited by 335
O’Kane, M. J., Bunting, B., Copeland, M., & Coates, V. E. (2008) · BMJ · doi:10.1136/bmj.39534.571644.be · Cited by 326
Meal-Related Structured Self-Monitoring of Blood Glucose
Schwedes, U., Siebolds, M., Mertes, G., & For the SMBG Study Group (2002) · Diabetes Care · doi:10.2337/diacare.25.11.1928 · Cited by 300
Guerci, B., Drouin, P., Grangé, V, Bougnères, P., Fontaine, P., Kerlan, V, Passa, P., Thivolet, C., Vialettes, B., & Charbonnel, B. (2003) · Diabetes & Metabolism · doi:10.1016/s1262-3636(07)70073-3 · Cited by 287
Self-monitoring of blood glucose in type 2 diabetes: systematic review
Clar, C., Barnard, K., Cummins, E., Royle, P., & Waugh, N. (2010) · Health Technology Assessment · doi:10.3310/hta14120 · Cited by 274
Ismail, K., Maissi, E., Thomas, S., Chalder, T., Schmidt, U., Bartlett, J., Patel, A., Dickens, C., Creed, F., & Treasure, J. (2010) · Health Technology Assessment · doi:10.3310/hta14220 · Cited by 245
Bode, B. W., Gross, T. M., Thornton, K. R., & Mastrototaro, J. J. (1999) · Diabetes Research and Clinical Practice · doi:10.1016/s0168-8227(99)00113-8 · Cited by 232
Simon, J., Gray, A., Clarke, P., Wade, A., Neil, A., & Farmer, A. (2008) · BMJ · doi:10.1136/bmj.39526.674873.be · Cited by 206
PROSPERO International prospective register of systematic reviews
Quayle, E., Cooper, K., Newman, E., & Cariola, L. A. (2017) · Cited by 186
Davidson, M. B., Castellanos, M., Kain, D., & Duran, P. (2005) · The American Journal of Medicine · doi:10.1016/j.amjmed.2004.12.006 · Cited by 178
Jr., J. N. S., Jr., N. A. N., Tan, K. M., & Grava, M. B. (2005) · Current Medical Research and Opinion · doi:10.1185/030079904x20286 · Cited by 177
Farmer, A. J., Perera, R., Ward, A., Heneghan, C., Oke, J., Barnett, A. H., Davidson, M. B., Guerci, B., Coates, V., Schwedes, U., et al. (2012) · BMJ · doi:10.1136/bmj.e486 · Cited by 156
Franciosi, M., Lucisano, G., Pellegrini, F., Cantarello, A., Consoli, A., Cucco, L., Ghidelli, R., Sartore, G., Sciangula, L., Nicolucci, A., et al. (2011) · Diabetic Medicine · doi:10.1111/j.1464-5491.2011.03268.x · Cited by 137
Poolsup, N., Suksomboon, N., & Rattanasookchit, S. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2009.0091 · Cited by 127
Self-monitoring of blood glucose in overweight type 2 diabetic patients
Muchmore, D. B., Springer, J., & Miller, M. J. (1994) · Acta Diabetologica · doi:10.1007/bf00571954 · Cited by 126
Barnett, A. H., Krentz, A. J., Strojek, K., Sieradzki, J., Azizi, F., Embong, M., Imamoglu, S., Perušičová, J., Uličiansky, V., & Winkler, G. (2008) · Diabetes, Obesity and Metabolism · doi:10.1111/j.1463-1326.2008.00894.x · Cited by 106
The value of self-monitoring of blood glucose: a review of recent evidence
John, A. S., Davis, W. A., Price, C. P., & Davis, T. M. E. (2009) · Journal of Diabetes and its Complications · doi:10.1016/j.jdiacomp.2009.01.002 · Cited by 90
Fontbonne, A., Billault, B., Acosta, M., Percheron, C., Varenne, P., Besse, A., Eschwège, É., Monnier, L., Slama, G., & Passa, P. (1989) · PubMed · Cited by 80
Malanda, U., Bot, S., & Nijpels, G. (2013) · Rivm (National Institute for Public Health and the Environment) · doi:10.2337/dc12-0831document · Cited by 74
Rating the quality of evidence and the strength of recommendations using GRADE
Canfield, S. E., & Dahm, P. (2011) · World Journal of Urology · doi:10.1007/s00345-011-0667-2 · Cited by 62 · cited 2×
“0474 ⊕⊕⊕⊖ Moderate *Grading of Recommendation, Assessment, Development, and Evaluation (GRADE).(21) BMI, body mass index; DBP, diastolic blood pressure; FPG, fasting plasma glucose; HbA1c, glycated haemoglobin; HDL, high-density lipoprotein; LDL, low-density lipoprotein; MD, mean difference; SBP, systolic blood pressu…”
MethodLü, J., Bu, R., Sun, Z., Lu, Q.-B., Jin, H., Wang, Y., Wang, S. H., Li, L., Xie, Z., & Yang, B. (2011) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2011.04.012 · Cited by 57
Self-monitoring of blood glucose in tablet-treated type 2 diabetic patients (ZODIAC).
Kleefstra, N., Hortensius, J., Logtenberg, S. J. J., Slingerland, R. J., Groenier, K. H., Houweling, S. T., Gans, R. O. B., van Ballegooie, E., & Bilo, H. J. G. (2010) · PubMed · Cited by 41
Kempf, K., Tankova, T., & Martin, S. (2013) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2012.0213 · Cited by 40
McIntosh, B., Yu, C., Lal, A., Chelak, K., Cameron, C. G., Singh, S. R., & Dahl, M. (2010) · PubMed Central · Cited by 40
Harashima, S., Fukushima, T., Sasaki, M., Nishi, Y., Fujimoto, S., Ogura, M., Yamane, S., Tanaka, D., Harada, N., Hamasaki, A., et al. (2013) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.2363 · Cited by 26
García de la Torre, N., Durán, A., del Valle, L., Fuentes, M., Barca, I., Martín, P., Montañez, C., Perez-Ferre, N., Abad, R., Sanz, F., et al. (2013) · Acta Diabetologica · doi:10.1007/s00592-013-0467-9 · Cited by 24
Davidson, J. A., Wolffenbuttel, B. H. R., Arakaki, R. F., Caballero, A. E., Jiang, H. H., & Hardin, D. S. (2013) · PubMed · Cited by 17
Malanda, U. L., Bot, S. D. M., Kostense, P. J., Snoek, F. J., Dekker, J. M., & Nijpels, G. (2016) · Diabetic Medicine · doi:10.1111/dme.12849 · Cited by 12
Shekelle, P., Munjas, B. A., Romanová, M., Towfigh, A., Weinreb, J. E., Zhou, A., & Suttorp, M. J. (2007) · Europe PMC (PubMed Central) · Cited by 5
Cited by
Hennessy, E. A., Johnson, B. T., Acabchuk, R. L., McCloskey, K., & Stewart-James, J. (2020) · Health Psychology Review · doi:10.1080/17437199.2019.1679654 · Cited by 239
“…and cholesterol, had mixed results, with one meta-analysis of eight studies indicating a significant reduction in total cholesterol (Zhu et al., 2016) and two meta-analyses indicating that benefits did not translate to systolic or diastolic blood pressure (Farmer et al., 2012; Zhu et al., 2016).”
ResultSendekie, A. K., Netere, A. K., Kasahun, A. E., & Belachew, E. A. (2022) · PLoS ONE · doi:10.1371/journal.pone.0274971 · Cited by 151
Mannucci, E., Antenore, A., Giorgino, F., & Scavini, M. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296817719290 · Cited by 90
“4% in patients using SMBG compared with control groups not using SMBG.(6-12) The reported size of HbA1c reduction may be perceived as small and may be influenced by some characteristics of the study participants, including baseline HbA1c and type of prescribed diabetes medications.”
BackgroundGlycemic control among diabetic patients in Ethiopia: A systematic review and meta-analysis
Gebreyohannes, E. A., Netere, A. K., & Belachew, S. A. (2019) · PLOS ONE · doi:10.1371/journal.pone.0221790 · Cited by 84
Efficacy of telemedicine on glycaemic control in patients with type 2 diabetes: A meta-analysis
De Groot, J., Wu, D., Flynn, D., Robertson, D., Grant, G., & Sun, J. (2021) · World Journal of Diabetes · doi:10.4239/wjd.v12.i2.170 · Cited by 77
Metadata
- Authors
- Zhu, H., Zhu, Y., & Leung, S.-W.
- Affiliations
- University of Macau (MO)
- Corresponding author
- Leung, Siu-wai
- Venue
- BMJ Open
- Publisher
- BMJ
- Published
- 2016-09
- Volume
- 6
- Issue
- 9
- Pages
- e010524
- ISSN
- 2044-6055 (ISSN-L)
- PMC
- PMC5020874
- OpenAlex
- W2510638245
- Cited by
- 84
- References
- 42
- Citations by year
- 2026: 4 · 2025: 2 · 2024: 1 · 2023: 16 · 2022: 13 · 2021: 8 · 2020: 8 · 2019: 15 · 2018: 10 · 2017: 7
- FWCI
- 1.57
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by-nc
- Locations
- BMJ Open (publishedVersion, cc-by-nc)
- Europe PMC (PubMed Central) (publishedVersion, cc-by-nc)
- PubMed Central (publishedVersion, cc-by-nc)
- PubMed (publishedVersion)
- HighWire Press Open Archive (submittedVersion)
- Funders
- Universidade de Macau (MYRG2014-00117-ICMS-QRCM)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Keywords
- self-monitoring of blood glucose, type 2 diabetes, non-insulin-treated diabetes, glycemic control, HbA1c, body mass index, total cholesterol, patient self-management, lifestyle intervention, risk of bias, publication bias, subgroup analysis, quality of evidence, GRADE
- MeSH terms
- Adult, Aged, Blood Glucose, Diabetes Mellitus, Type 2, Glycated Hemoglobin, Humans, Insulin, Middle Aged, Blood Glucose Self-Monitoring, Treatment Outcome
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.