Muscle Oxygenation Trends During Dynamic Exercise Measured by Near Infrared Spectroscopy
The DOI matches its Crossref record; 54 of the 54 references it cites were found in a registry or an index.
Abstract
During the last decade, NIRS has been used extensively to evaluate the changes in muscle oxygenation and blood volume during a variety of exercise modes. The important findings from this research are as follows: (a) There is a strong correlation between the lactate (ventilatory) threshold during incremental cycle exercise and the exaggerated reduction in muscle oxygenation measured by NIRS. (b) The delay in steady-state oxygen uptake during constant work rate exercise at intensities above the lactate/ventilatory threshold is closely related to changes in muscle oxygenation measured by NIRS. (c) The degree of muscle deoxygenation at the same absolute oxygen uptake is significantly lower in older persons compared younger persons; however, these changes are negated when muscle oxygenation is expressed relative to maximal oxygen uptake values. (d) There is no significant difference between the rate of biceps brachii and vastus lateralis deoxygenation during arm cranking and leg cycling exercise, respectively, in males and females. (e) Muscle deoxygenation trends recorded during short duration, high-intensity exercise such as the Wingate test indicate that there is a substantial degree of aerobic metabolism during such exercise. Recent studies that have used NIRS at multiple sites, such as brain and muscle tissue, provide useful information pertaining to the regional changes in oxygen availability in these tissues during dynamic exercise.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Muscle oxygenation dynamics during incremental exercise have been documented in four phases (Bhambhani, 2004).”
From Muscle Oxygen Saturation Breakpoints Reflect Ventilatory Thresholds in Both Cycling and Running (2022) · cites this paper as Bhambhani, 2004
In the citing paper
“The time course of SmO2 reflects expected changes as a result of increasing performance (Figure 1) with three phases as described by Bhambhani (2004).”
From Muscle Oxygen Saturation Breakpoints Reflect Ventilatory Thresholds in Both Cycling and Running (2022) · cites this paper as Bhambhani, 2004
Citations
Cites
Principles, Techniques, and Limitations of Near Infrared Spectroscopy
Ferrari, M., Mottola, L., & Quaresima, V. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-031 · Cited by 997
Owen-Reece, H., Smith, M., Elwell, C. E., & Goldstone, J. C. (1999) · British Journal of Anaesthesia · doi:10.1093/bja/82.3.418 · Cited by 688
Validation of near-infrared spectroscopy in humans
Mancini, D. M., Bolinger, L., Li, H., Kendrick, K., Chance, B., & Wilson, J. R. (1994) · Journal of Applied Physiology · doi:10.1152/jappl.1994.77.6.2740 · Cited by 669 · cited 2×
“Although the contribution of MbO2 is quite small (Mancini et al., 1994), it could confound the validity of the findings of studies that attempt to correlate femoral venous oxygen tension with that obtained from NIRS absorbency readings.”
BackgroundInfluentialRecovery from exercise-induced desaturation in the quadriceps muscles of elite competitive rowers
Chance, B., Dait, M. T., Zhang, C., Hamaoka, T., & Hagerman, F. (1992) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1992.262.3.c766 · Cited by 528 · cited 1×
“Chance et al. (1992) demonstrated that the half time for Mox recovery from maximal rowing exercise was significantly correlated with repayment of the oxygen debt and the removal of lactate following exercise.”
BackgroundInteraction of physiological mechanisms during exercise.
Wasserman, K., Van Kessel, A. L., & Burton, G. G. (1967) · Journal of Applied Physiology · doi:10.1152/jappl.1967.22.1.71 · Cited by 526 · cited 2×
“The LT and TDMA can be detected noninvasively via alterations in respiratory gas exchange measurements during incremental exercise (Reinhard et al., 1979; Wasserman et al., 1967).”
BackgroundAdipose tissue thickness affects in vivo quantitative near-IR spectroscopy in human skeletal muscle
VAN BEEKVELT, M. C. P., BORGHUIS, M. S., VAN ENGELEN, B. G. M., WEVERS, R. A., & COLIER, W. N. J. M. (2001) · Clinical Science · doi:10.1042/cs1010021 · Cited by 369 · cited 2×
“Research (van Beekvelt et al., 2001) that has systematically examined the influence of adipose tissue thickness on the NIRS-determined oxygen consumption of the flexor digitorum superficialis muscle during sustained isometric handgrip 520 • Bhambhani exercise has indicated an inverse relationship…”
BackgroundHamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2805437 · Cited by 329
Near infrared monitoring of human skeletal muscle oxygenation during forearm ischemia
Hampson, N. B., & Piantadosi, C. A. (1988) · Journal of Applied Physiology · doi:10.1152/jappl.1988.64.6.2449 · Cited by 300 · cited 1×
“Of these two, the contribution of the skin to the total NIRS signal is quite small: approximately 5% if the source and detector of the NIRS probe are separated by more than 20 mm (Hampson and Piantidosi, 1988).”
BackgroundRådegran, G. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.83.4.1383 · Cited by 297 · cited 1×
“The latter is likely due to the fact that during the transition from rest to maximal exercise, the increase in intramuscular pressure during the contraction phase exceeds the rise in intravascular pressure, thereby decreasing the ability of blood to perfuse the exercising muscle (Radegran, 1997).”
BackgroundDetermination of Anaerobic Threshold by the Ventilation Equivalent in Normal Individuals
Reinhard, U., Müller, P. H., & Schmülling, R.-M. (2009) · Respiration · doi:10.1159/000194056 · Cited by 271 · cited 5×
“, the second metabolic threshold (Reinhard et al., 1979).”
BackgroundInfluential
Research works printed but not linked: 7
- Belardinelli R., 1995, G. Ital. Cardiol., 25, 715
- Demarie S., 2001, J. Sports Med. Phys. Fitness, 41, 448
- Matsushita K., 1998, Proc. SPIE Int. Soc. Opt. Eng., 3194, 159
- McCully K.K., 2000, Exerc. Sport Sci. Rev., 28, 123
- Nielsen H.B., 2001, Acta Phsyiol. Scand., 171, 63
- Nielsen H.B., 1999, Am. J. Physiol., 277, H1045
- Wasserman K., 1991, NIPS, 6, 29
Cited by
Principles, Techniques, and Limitations of Near Infrared Spectroscopy
Ferrari, M., Mottola, L., & Quaresima, V. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-031 · Cited by 997
Progress of near-infrared spectroscopy and topography for brain and muscle clinical applications
Ferrari, M. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2804899 · Cited by 600
Ferrari, M., Muthalib, M., & Quaresima, V. (2011) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2011.0230 · Cited by 450
Hamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2805437 · Cited by 329
Effects of acute hypoxia on cerebral and muscle oxygenation during incremental exercise
Subudhi, A. W., Dimmen, A. C., & Roach, R. C. (2007) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01460.2006 · Cited by 271
Ekkekakis, P. (2009) · Journal of Sport and Exercise Psychology · doi:10.1123/jsep.31.4.505 · Cited by 218
“…in exercise science for several years but has been applied mainly to the noninvasive investigation of the hemodynamics of the working muscle (e.g., Bhambhani, 2004; Boushel et al., 2001; Neary, 2004; Pereira, Gomes, & Bhambhani, 2007; Quaresima, Lepanto, & Ferrari, 2003; for a recent exception,…”
MethodValidity and reliability of the Moxy oxygen monitor during incremental cycling exercise
Crum, E. M., O'Connor, W. J., Van Loo, L., Valckx, M., & Stannard, S. R. (2017) · European Journal of Sport Science · doi:10.1080/17461391.2017.1330899 · Cited by 206
“Minute ventilation (VE) and concentrations of O2 and CO2 values were used to calculate the volume of inspired air (VI) using the Haldane transformation, where VE was corrected for barometric pressure, ambient temperature and atmospheric water saturation.”
BackgroundInfluentialHamaoka, T., McCully, K. K., Niwayama, M., & Chance, B. (2011) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2011.0298 · Cited by 186
McManus, C. J., Collison, J., & Cooper, C. E. (2018) · Journal of Biomedical Optics · doi:10.1117/1.jbo.23.1.015007 · Cited by 205
“It is generally assumed that NIR light reaching a detector has an effective penetration depth of ∼50% to 60% of the interoptode distance.(31) Therefore, the PortaMon (maximum source:detector separation of 40 mm) would be expected to detect more light from the deeper muscle tissue than the MOXY (maximum source:detector…”
BackgroundRespiratory muscle unloading improves leg muscle oxygenation during exercise in patients with COPD
Borghi-Silva, A., Oliveira, C. C., Carrascosa, C., Maia, J., Berton, D. C., Queiroga, F., Ferreira, E. M., Almeida, D. R., Nery, L. E., & Neder, J. A. (2008) · Thorax · doi:10.1136/thx.2007.090167 · Cited by 156
Near Infrared Brain and Muscle Oximetry: From the Discovery to Current Applications
Ferrari, M., & Quaresima, V. (2012) · Journal of Near Infrared Spectroscopy · doi:10.1255/jnirs.973 · Cited by 116
Repeated‐sprint performance and vastus lateralis oxygenation: Effect of limited O 2 availability
Billaut, F., & Buchheit, M. (2013) · Scandinavian Journal of Medicine and Science in Sports · doi:10.1111/sms.12052 · Cited by 123
“…a measure of the local tissue blood volume, whereas the individual concentrations of the two forms of hemoglobin are the result of the interplay between physiological parameters such as regional blood volume, regional blood flow, and metabolic rate of oxygen (Grassi et al., 2003; Bhambhani, 2004).”
BackgroundMethodBiceps brachii myoelectric and oxygenation changes during static and sinusoidal isometric exercises
Felici, F., Quaresima, V., Fattorini, L., Sbriccoli, P., Filligoi, G. C., & Ferrari, M. (2007) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2007.07.010 · Cited by 110
Archiza, B., Andaku, D. K., Caruso, F., Bonjorno, J. C., de Oliveira, C. R., Ricci, P. A., Amaral, A. C., Mattiello, S. M., Libardi, C. A., Phillips, S. A., et al. (2017) · Journal of Sports Sciences · doi:10.1080/02640414.2017.1340659 · Cited by 115
“Also, [tHb] has been used as an index of local blood volume as [Hbtot] = [O2Hb] + [HHb] (Bhambhani, 2004; Borghi-Silva et al., 2008).”
MethodFerreira, L. F., Hueber, D. M., & Barstow, T. J. (2007) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00920.2005 · Cited by 90
“Due to its relative ease of use and noninvasive nature, NIRS has gained wide acceptance in the investigation of muscle oxygenation in exercising humans (3), without any direct examination of the potential confounding effects of the underlying assumption that scattering is constant during exercise.”
BackgroundPereira, M., Gomes, P. S. C., & BHAMBHANI, Y. N. (2007) · Sports Medicine · doi:10.2165/00007256-200737070-00005 · Cited by 118
Self-citationRegulation of Cellular Gas Exchange, Oxygen Sensing, and Metabolic Control
Clanton, T. L., Hogan, M. C., & Gladden, L. B. (2013) · Comprehensive Physiology · doi:10.1002/cphy.c120030 · Cited by 80
van der Zwaard, S., Jaspers, R. T., Blokland, I. J., Achterberg, C., Visser, J. M., den Uil, A. R., Hofmijster, M. J., Levels, K., Noordhof, D. A., de Haan, A., et al. (2016) · PLOS ONE · doi:10.1371/journal.pone.0162914 · Cited by 95
“Asymmetrical changes during exercise may partially be explained by blood volume changes [26,49], increased haemoglobin concentration (i.”
BackgroundRelated Trends in Locomotor and Respiratory Muscle Oxygenation during Exercise
LEGRAND, R., MARLES, A., PRIEUR, F., LAZZARI, S., BLONDEL, N., & MUCCI, P. (2007) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000241638.90348.67 · Cited by 70
Novel links between HIFs, type 2 diabetes, and metabolic syndrome
Girgis, C. M., Cheng, K., Scott, C. H., & Gunton, J. E. (2012) · Trends in Endocrinology and Metabolism · doi:10.1016/j.tem.2012.05.003 · Cited by 83
Application of Near Infrared Spectroscopy to Exercise Sports Science
Neary, J. P. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-032 · Cited by 73
“Passons, parce qu’elle a été discutée précédemment, la question des principes, des techniques, des limites, de la fiabilité, et de la validité de la NIRS pour l’étude des tissus cérébral et musculaire (Bhambhani 2004), surtout au cours d’un effort donné.”
BackgroundInfluentialLai, N., Zhou, H., Saidel, G. M., Wolf, M., McCully, K., Gladden, L. B., & Cabrera, M. E. (2009) · Journal of Applied Physiology · doi:10.1152/japplphysiol.91102.2008 · Cited by 72
“NEAR-INFRARED SPECTROSCOPY (NIRS) is applied to study tissue oxygenation in brain and skeletal muscle under a variety of experimental conditions (3, 5, 21, 27, 46, 56, 66).”
MethodAcute l-arginine supplementation increases muscle blood volume but not strength performance
Álvares, T. S., Conte, C. A., Paschoalin, V. M. F., Silva, J. T., Meirelles, C. D. M., Bhambhani, Y. N., & Gomes, P. S. C. (2012) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/h11-144 · Cited by 71
Self-citationEvaluation of cartilage defects with near-infrared spectroscopy (NIR): An ex vivo study
Spahn, G., Plettenberg, H., Nagel, H., Kahl, E., Klinger, H.-M., Mückley, T., Günther, M., Hofmann, G. O., & Mollenhauer, J. A. (2007) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2007.04.009 · Cited by 69
“liver [23], skin [24], and muscle [ 25 ] oxygenization.”
BackgroundGastrocnemius Medialis and Vastus Lateralis Oxygenation during Whole-Body Vibration Exercise
CARDINALE, M., FERRARI, M., & QUARESIMA, V. (2007) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31803084d8 · Cited by 60
“The possibility of noninvasively studying local muscle oxidative metabolism during exercise has been enhanced in the last few years, thanks to the use of NIRS ( 2 ,10,12,15, 21,31).”
BackgroundMethodInfluentialMoalla, W., Elloumi, M., Chamari, K., Dupont, G., Maingourd, Y., Tabka, Z., & Ahmaïdi, S. (2012) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/h2012-036 · Cited by 63
Esaki, K., Hamaoka, T., Rådegran, G., Boushel, R., Hansen, J., Katsumura, T., Haga, S., & Mizuno, M. (2005) · European Journal of Applied Physiology · doi:10.1007/s00421-005-0008-5 · Cited by 65
“Bhambhani (2004) suggested that the findings observed by Quaresima et al. (2001) highlight the importance of ensuring the consistency of probe placement among NIRS studies so that appropriate comparisons can be made.”
BackgroundMethodHofmann, G. O., Marticke, J. K., Großstück, R., Hoffmann, M., Lange, M., Plettenberg, H., Braunschweig, R., Schilling, O., Kaden, I., & Spahn, G. (2009) · Pathophysiology · doi:10.1016/j.pathophys.2009.04.001 · Cited by 53
Faster Pulmonary Oxygen Uptake Kinetics in Trained versus Untrained Male Adolescents
Marwood, S., Roche, D. M., Rowland, T., Garrard, M., & Unnithan, V. B. (2009) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181af20d0 · Cited by 53
“Fat acts as a low-scattering constant absorber of near infrared light; therefore increased subcutaneous fat has the potential to blunt the interrogative depth of near infrared light into the exercising muscle (9,43) and reduce the detectable change in haemoglobin oxygenation in response to exercise (43).”
BackgroundMuscle Oxygen Supply Impairment during Exercise in Poorly Controlled Type 1 Diabetes
Tagougui, S., Leclair, E., Fontaine, P., Matran, R., Marais, G., Aucouturier, J., Descatoire, A., Vambergue, A., Oussaidene, K., Baquet, G., et al. (2014) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000424 · Cited by 53
“Therefore, the significant increase in $THb in both groups of healthy controls and of patients with adequate glycemic control in the present study is consistent with the increase in muscle blood volume usually observed with increasing exercise intensity (7).”
BackgroundResultQuantitative Biomedical Optics: Theory, Methods, and Applications
Bigio, I. J., & Fantini, S. (2016) · Cited by 46
Binzoni, T., Cooper, C. E., Wittekind, A., Beneke, R., Elwell, C. E., Ville, D. V. D., & Leung, T. S. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/9/014 · Cited by 47
Vastus Lateralis O2 Desaturation in Response to Fast and Short Maximal Contraction
CETTOLO, V., FERRARI, M., BIASINI, V., & QUARESIMA, V. (2007) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181453476 · Cited by 40
Biceps brachii muscle oxygenation in electrical muscle stimulation
Muthalib, M., Jubeau, M., Millet, G. Y., Maffiuletti, N. A., Ferrari, M., & Nosaka, K. (2010) · Clinical Physiology and Functional Imaging · doi:10.1111/j.1475-097x.2010.00953.x · Cited by 40
“The theoretical basis, application and limitations of NIRS have been previously reviewed (Bhambhani, 2004; Ferrari et al., 2004; Neary, 2004).”
BackgroundTuesta, M., Yáñez-Sepúlveda, R., Verdugo-Marchese, H., Mateluna, C., & Alvear-Ordenes, I. (2022) · Biology · doi:10.3390/biology11071073 · Cited by 37
“For that, muscle oxygenation was obtained by the relative changes in the oxy/deoxyhemoglobin/myoglobin concentrations and blood flow by changes in total hemoglobin, as was previously described [9,76,77].”
MethodPaquette, M., Bieuzen, F., & Billaut, F. (2019) · Frontiers in Sports and Active Living · doi:10.3389/fspor.2019.00006 · Cited by 40
“In supramaximal efforts, it is likely that strong muscle contraction limit O2 delivery (Bhambhani, 2004), as suggested by decreased total hemoglobin concentration during SIT (Jones et al.”
Backgroundde Oliveira, G. V., do Nascimento, L. A. D., Volino‐Souza, M., Mesquita, J. S., & Álvares, T. S. (2018) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2017-0828 · Cited by 39
“Muscle oxygenation may be measured non-invasively by near-infrared 54 spectroscopy (NIRS), which register the balance between muscle O2 delivery and 55 utilization during exercise and/or exercise recovery in real time (Bhambhani, 2004).”
Methodde Oliveira, G. V., Morgado, M., Conte‐Júnior, C. A., & Álvares, T. S. (2017) · PLoS ONE · doi:10.1371/journal.pone.0188893 · Cited by 36
Angius, L., & Crisafulli, A. (2020) · European Journal of Preventive Cardiology · doi:10.1177/2047487320906919 · Cited by 36
The repeated-bout effect: influence on biceps brachii oxygenation and myoelectrical activity
Muthalib, M., Lee, H.-S., Millet, G. Y., Ferrari, M., & Nosaka, K. (2011) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00191.2010 · Cited by 36
“The theoretical basis, application, and limitations of NIRS have been previously reviewed (3, 13, 25).”
BackgroundMuscle Oxygen Saturation Breakpoints Reflect Ventilatory Thresholds in Both Cycling and Running
Feldmann, A., Ammann, L., Gächter, F., Zibung, M., & Erlacher, D. (2022) · Journal of Human Kinetics · doi:10.2478/hukin-2022-0054 · Cited by 41
“A fourth phase described by Bhambhani (2004) is the expected hyperemia response, and it was also seen, but not analyzed.”
BackgroundInfluentialKounalakis, S. N., & Geladas, N. D. (2012) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/h2012-011 · Cited by 38
Manchado-Gobatto, F. D. B., Marostegan, A. B., Rasteiro, F. M., Cirino, C., da Cruz, J. P., Moreno, M. A., & Gobatto, C. A. (2020) · Scientific Reports · doi:10.1038/s41598-020-63297-w · Cited by 36
Biomedical applications of wireless continuous wave near infrared spectroscopy
Macnab, A. J., & Shadgan, B. (2012) · Biomedical Spectroscopy and Imaging · doi:10.3233/bsi-2012-0018 · Cited by 33
“…been extensively used by exercise scientists to investigate changes in muscle oxygen consumption and perfusion during different types of exercise [4–6, 28 , There is a growing literature reporting studies using wireless CW NIRS that have increased understanding of muscle physiology [8–12, 17,41,…”
Olivier, N., Weissland, T., Legrand, R., Berthoin, S., Rogez, J., Thévenon, A., & Prieur, F. (2010) · Clinical Journal of Sport Medicine · doi:10.1097/jsm.0b013e3181c967b8 · Cited by 31
Lai, N., Dash, R. K., Nasca, M. M., Saidel, G. M., & Cabrera, M. E. (2006) · European Journal of Applied Physiology · doi:10.1007/s00421-006-0176-y · Cited by 37
“2005; Richard et al. 2004; Rowland and Obert 2002; Tordi et al. 2004) and muscle oxygenation ( Bhambhani 2004; Cerretelli and Grassi 2001; Ferrari et al. 2004; Neary 2004; Rolfe 2000).”
BackgroundGeraskin, D., Boeth, H., & Kohl‐Bareis, M. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3184425 · Cited by 33
Zhang, Z., Wang, B., Gong, H., Xu, G., Nioka, S., & Chance, B. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3309741 · Cited by 34
“The accumulated H+ in the local muscle will increase the oxyhemoglobin dissociation via the Bohr effect and consequently accelerate the decrease in muscle oxygenation.(17) The accumulated H+ will also be transported out of the muscle and be buffered by bicarbonate or other buffers in the systemic blood, resulting in t…”
BackgroundResultInfluentialMatsuura, C., Gomes, P. S. C., Haykowsky, M. J., & BHAMBHANI, Y. N. (2010) · Clinical Physiology and Functional Imaging · doi:10.1111/j.1475-097x.2010.00986.x · Cited by 31
“…Physiol Funct Imaging (2011) 31, pp114–123 doi: 10.1111/j.1475-097X.2010.00986.x 2010 The Authors Clinical Physiology and Functional Imaging 2010 Scandinavian Society of Clinical Physiology and Nuclear Medicine 31, 2, 114–123114 to be an index of mitochondrial oxygen utilization (Bhambhani, 2004).”
BackgroundInfluentialSelf-citationRissanen, A.-P. E., Tikkanen, H. O., Koponen, A. S., Aho, J. M., Hägglund, H., Lindholm, H., & Peltonen, J. E. (2012) · Frontiers in Physiology · doi:10.3389/fphys.2012.00265 · Cited by 25
“…that metabolic changes within the muscle tissue affect oxygenation changes, and are one essential part of ventilatory response control during incremental exercise (Turner, 1991; Bhambhani, 2004), but there likely is more inter-individual variability during treadmill exercise than during cycling.”
BackgroundFlodgren, G., Crenshaw, A. G., Hellström, F., & Fahlström, M. (2010) · BioMed Research International · doi:10.1155/2010/513803 · Cited by 24
“In this, and in previous studies [9, 10], the work and the position of the probe were standardised, to enable appropriate comparison between studies [55].”
ResultThe evolution of near infrared spectroscopy in urology
Macnab, A. J. (2014) · Biomedical Spectroscopy and Imaging · doi:10.3233/bsi-140091 · Cited by 25
“The relevant literature is broad coming from studies of muscle, brain, and other tissues where reproducible effects on NIRS parameters are seen in response to physiologic effects generated in experimental studies, or observed to occur in the microcirculation due to specific systemic and organ pathology [12,13,16,24,34…”
BackgroundNon-invasive physiological monitoring of exercise and fitness
Burkow-Heikkinen, L. (2011) · Neurological Research · doi:10.1179/1743132810y.0000000014 · Cited by 26
(2012) · Europe PMC (PubMed Central) · Cited by 23
Macnab, A. J., Shadgan, B., & Stothers, L. S. (2012) · Journal of Near Infrared Spectroscopy · doi:10.1255/jnirs.963 · Cited by 23
Wolf, U., Wolf, M., Choi, J. H., Paunescu, L. A., Michalos, A., & Gratton, E. (2007) · Journal of Vascular and Interventional Radiology · doi:10.1016/j.jvir.2007.06.004 · Cited by 25
Muscle oxygenation trends after tapering in trained cyclists
Neary, J. P., McKenzie, D. C., & BHAMBHANI, Y. N. (2005) · Dynamic Medicine · doi:10.1186/1476-5918-4-4 · Cited by 24
“Therefore, it appears that NIRSCWS can be used to record the peripheral metabolic changes in trained endurance cyclists after a period of taper training, and this research has contributed further to our understanding of the application of NIRS to exercise sports science [45-47].”
Self-citationAllart, E., Olivier, N., Hovart, H., Thévenon, A., & Tiffreau, V. (2012) · Neuromuscular Disorders · doi:10.1016/j.nmd.2012.04.011 · Cited by 25
“The NIRS signal reflects the balance between O2 supply by the circulation and O2 consumption by the muscle and thus enables the measurement of not only quantitative variations in muscle oxygenation but also the kinetics of deoxygenation and reoxygenation (for a review, see [6,7]).”
Oranchuk, D. J., Koral, J., da Mota, G. R., Wrightson, J. G., Soares, R. N., Twomey, R., & Millet, G. Y. (2019) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2019-0579 · Cited by 23
“…exercise modes such as walking, running or cycling do not result in substantial decreases in muscle oxygenation in healthy humans at submaximal exercise intensities Page 3 of 29 https://mc06.manuscriptcentral.com/apnm-pubs Applied Physiology, Nutrition, and Metabolism Draft 4 (Bhambhani 2004).”
BackgroundPaulauskas, R., Kamarauskas, P., Nekriošius, R., & Bigwood, N. M. (2020) · Journal of Human Kinetics · doi:10.2478/hukin-2019-0100 · Cited by 23
“Since SmO2 is a measure of the mean localised muscle capillary content, greater O2 muscle uptake means the O2 content of the capillaries perfusing the muscle will decrease, as this includes the inflow of O2 as well as the outflow of CO2 (Bhambhani, 2004).”
BackgroundAcute effects of sustained isometric knee extension on cerebral and muscle oxygenation responses
Pereira, M., Gomes, P. S. C., & BHAMBHANI, Y. N. (2009) · Clinical Physiology and Functional Imaging · doi:10.1111/j.1475-097x.2009.00870.x · Cited by 25
“While these criteria were developed on the cerebral (Bhambhani et al., 2007; Rasmussen et al., 2007a; Perrey, 2008) and muscle (Bhambhani, 2004; Racinais et al., 2007) hemodynamic factors that can be measured by NIRS, other direct measures of neuronal activation such as electroencephalography and…”
BackgroundSelf-citationPhysiological influence of basic perturbations assessed by non-invasive optical techniques in humans
Svanberg, E. K., Wollmer, P., Andersson‐Engels, S., & Åkeson, J. (2011) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/h11-119 · Cited by 21
Agbangla, N. F., Audiffren, M. F., & Albinet, C. T. (2017) · Physiological Research · doi:10.33549/physiolres.933612 · Cited by 21
“Because these two chromophores have identical spectral characteristics, it is impossible to distinguish their respective light absorption (Binzoni et al. 1999, Van Beekvelt et al. 2001, Bhambhani 2004).”
BackgroundDalamitros, A. A., Semaltianou, E., Toubekis, A. G., & Kabasakalis, A. (2021) · Frontiers in Sports and Active Living · doi:10.3389/fspor.2021.759925 · Cited by 19
“Near-infrared spectroscopy (NIRS) is a relatively new technique with increasing popularity due to the fact that it non-invasively and directly enables measurements of changes in tissue oxygenation and hemodynamics as a response to dynamic exercise (Bhambhani, 2004).”
BackgroundNear‐Infrared Spectroscopy of the Bladder: New Parameters for Evaluating Voiding Dysfunction
Macnab, A. J., Shadgan, B., Afshar, K., & Stothers, L. S. (2011) · International Journal of Spectroscopy · doi:10.1155/2011/814179 · Cited by 22
Olivier, N., Thévenon, A., Berthoin, S., & Prieur, F. (2012) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2012.10.028 · Cited by 26
Kauppi, K., Korhonen, V. O., Ferdinando, H., Kallio, M., & Myllylä, T. (2017) · Journal of Innovative Optical Health Sciences · doi:10.1142/s1793545816500565 · Cited by 20
Beyond VO2: the complex cardiopulmonary exercise test
Mattavelli, I., Vignati, C., Farina, S., Apostolo, A., Cattadori, G., Martino, F. D., Pezzuto, B., Zaffalon, D., & Agostoni, P. (2023) · European Journal of Preventive Cardiology · doi:10.1093/eurjpc/zwad154 · Cited by 22
Marwood, S., Roche, D. M., Garrard, M., & Unnithan, V. B. (2011) · European Journal of Applied Physiology · doi:10.1007/s00421-011-1901-8 · Cited by 20
“Since fat acts as a low-scattering constant absorber of near-infrared light an increased subcutaneous fat thickness has the potential to blunt the interrogative depth of near-infrared light into the tissue of interest and therefore reduce the detectable change in haemoglobin oxygenation in response to exercise (Bhambh…”
BackgroundBourdillon, N., Mollard, P., Letournel, M., Beaudry, M., & Richalet, J. (2009) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2009.08.011 · Cited by 20
Muscle deoxygenation of upper-limb muscles during progressive arm-cranking exercise
Lusina, S.-J. C., Warburton, D. E. R., Hatfield, N. G., & Sheel, A. W. (2008) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/h07-156 · Cited by 18
“The theory and application of NIRS has been described in detail elsewhere (Bhambhani 2004; Boushel et al. 2001; Boushel and Piantadosi 2000; Elwell 1995; Neary 2004).”
BackgroundMethodBHAMBHANI, Y. N. (2012) · Journal of Near Infrared Spectroscopy · doi:10.1255/jnirs.978 · Cited by 19
Self-citationContreras-Briceño, F., Espinosa-Ramirez, M., Keim-Bagnara, V., Carreño-Román, M., Rodríguez-Villagra, R., Villegas-Belmar, F., Viscor, G., Gabrielli, L., Andía, M. E., Araneda, O. F., et al. (2022) · Life · doi:10.3390/life12030444 · Cited by 17
“…responses during exercise in a non-steady-state [19], breathing patterns adopted during effort [21], intensity of physical exercise performed [20,34–36], decreased muscle perfusion as a consequence of muscular contractions [37,38], loss of SmO 2 signal due to changes in positions and/or adipose…”
Monitoring Detrusor Oxygenation and Hemodynamics Noninvasively during Dysfunctional Voiding
Macnab, A. J., Stothers, L. S., & Shadgan, B. (2012) · Advances in Urology · doi:10.1155/2012/676303 · Cited by 17
“Simultaneous NIRS and UDS studies done to date, additional urologic research using wireless NIRS [9–11, 24], and the body of NIRS studies in muscle [2–4, 23, 25–28] offer urologists an opportunity to evaluate where abnormal detrusor hemodynamics or oxygen supply and demand underlie voiding dysfunction due to BPH.”
BackgroundThe effect of severe intensity bouts on muscle oxygen saturation responses in trained cyclists
Yogev, A., Arnold, J. I., Nelson, H., Clarke, D. C., Guenette, J. A., Sporer, B. C., & Koehle, M. S. (2023) · Frontiers in Sports and Active Living · doi:10.3389/fspor.2023.1086227 · Cited by 19
Barberán-García, A., Muñoz, P. A., Gimeno‐Santos, E., Burgos, F., Torralba, Y., Gistau, C., Roca, J., & Rodriguez, D. A. (2019) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12572 · Cited by 19
“…NIRS has evolved through significant achievements in terms of standardization of the technique leading to acceptable robustness of measurements (Bhambhani, 2004; Ferrari et al., 2004; Hamaoka et al., 2007) and well-established usefulness for monitoring in intensive care (Pareznik et al., 2006;…”
Changes in Tissue Oxygen Saturation in Response to Different Calf Compression Sleeves
Dermont, T., Morizot, L., Bouhaddi, M., & Ménétrier, A. (2015) · Journal of Sports Medicine · doi:10.1155/2015/857904 · Cited by 17
“A transparent film was placed between the skin and the probe to protect it from sweat [23].”
BackgroundAlgorithm construction methodology for diagnostic classification of near-infrared spectroscopy data
Erra, R. G., Stothers, L. S., & Macnab, A. J. (2011) · Spectroscopy An International Journal · doi:10.1155/2011/752101 · Cited by 19
Wang, B., Tian, Q., Zhang, Z., & Gong, H. (2012) · European Journal of Applied Physiology · doi:10.1007/s00421-011-2007-z · Cited by 15
“2001) has been introduced to the exercise physiology detection and has promoted our understanding of the aerobic metabolism in local skeletal muscles (Wolf et al. 2007; Hamaoka et al. 2007; Bhambhani 2004; Boushel et al. 2001; Zhang et al. 2010; Sako et al. 2001).”
BackgroundTabira, K., Horie, J., Fujii, H., Aida, T., Ito, K., Fukumoto, T., Imagita, H., & Ishihara, H. (2012) · Respiratory Care · doi:10.4187/respcare.01602 · Cited by 20
Influence of muscle fibre composition on muscle oxygenation during maximal running
Kitada, T., Machida, S., & Naıto, H. (2015) · BMJ Open Sport & Exercise Medicine · doi:10.1136/bmjsem-2015-000062 · Cited by 19
“5 cm.(5) 9 Changes in the NIRS signal are reported as Hb/Mb because the signal does not distinguish between Hb and Mb.”
BackgroundExercise Intolerance in Cystic Fibrosis: Importance of Skeletal Muscle
Rodriguez‐Miguelez, P., Seigler, N., Ishii, H., Crandall, R. H., McKie, K. T., Forseen, C. J., & Harris, R. A. (2020) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000002521 · Cited by 17
Homma, T., Hamaoka, T., Sako, T., Murakami, M., Esaki, K., Kime, R., & Katsumura, T. (2005) · Dynamic Medicine · doi:10.1186/1476-5918-4-2 · Cited by 16
“Since then, many more groups have applied this technique [16-20].”
MethodMetcalfe, R. S., & Vollaard, N. B. J. (2024) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2024-0024 · Cited by 18
Hasnan, N., Saadon, N. S. M., Hamzaid, N. A., Teoh, M., Ahmadi, S., & Davis, G. M. (2018) · Medicine · doi:10.1097/md.0000000000012922 · Cited by 14
“who observed a lower muscle deoxygenation during maximal exercise, and faster changes in muscle deoxygenation during exercise oxygen uptake (VO2) in SCI individuals when compared to their able-bodied cohort.([14]) Muscle oxygenation responses”
ResultPaulauskas, R., Nekriošius, R., Dadelienė, R., Sousa, A., & Figueira, B. (2022) · Sensors · doi:10.3390/s22218238 · Cited by 16
“Several studies have focused on the application of NIRS in assessing the effectiveness of sports training programs [9], and the effects of endurance, interval, and hypoxic training on muscle oxygenation in trained and untrained subjects [10].”
BackgroundReproducibility of Measurement of Muscle Deoxygenation in Children During Exercise
Leclair, E., Thévenet, D., Reguem, S. C., Borel, B., Baquet, G., Berthoin, S., & Mucci, P. (2010) · Pediatric Exercise Science · doi:10.1123/pes.22.2.183 · Cited by 15
Wilson, V. D., Thomas, C., Passerieux, E., Hugon, G., Pillard, F., de Andrade, A. G. P., Bommart, S., Picot, M., Pincemail, J., Mercier, J. G., et al. (2018) · JCSM Rapid Communications · doi:10.1002/j.2617-1619.2018.tb00002.x · Cited by 14
“Determination of muscle oxygenation by near‐infrared spectroscopy and data analysis The NIRS signal reflects the balance between O2 supply by the circulatory system and O2 consumption by the muscle and thus allows measuring the quantitative variations in muscle oxygenation, but also the kinetics of deoxygenation and r…”
BackgroundMethodNagasawa, T. (2013) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0b013e3182908fcc · Cited by 16
Anaerobic Capacity of the Upper Arms in Top-Level Team Handball Players
Kounalakis, S. N., Bayios, I. A., Koskolou, M. D., & Geladas, N. D. (2008) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.3.3.251 · Cited by 19
Uchiyama, K., Miaki, H., Terada, S., & Hoso, M. (2011) · Journal of Physical Therapy Science · doi:10.1589/jpts.23.349 · Cited by 13
Puttini, F., Pezzuto, B., & Vignati, C. (2025) · Medicina · doi:10.3390/medicina61101770 · Cited by 17
“…of inert gases, and thoracic bioimpedance [82], which measures changes in the electrical impedance of the chest generated by the passage of blood; while near-infrared spectroscopy (NIRS) allows non-invasive assessment of muscle oxygenation and, therefore, the state of peripheral perfusion [83].”
Portable muscle oxygenation monitor based on near infrared spectroscopy
Zhang, Z., Wang, B., Qing, N., Luo, Q., & Gong, H. (2009) · Frontiers of Optoelectronics in China · doi:10.1007/s12200-009-0050-8 · Cited by 12
Ichiwata, T., Sasao, G., Abe, T., Kikuchi, K., Koyama, K., Fujiwara, H., Nagai, A., Kuwahira, I., & Nagao, K. (2009) · Advances in experimental medicine and biology · doi:10.1007/978-1-4419-1241-1_78 · Cited by 11
“Near-infrared spectroscopy (NIRS) has recently been used to evaluate muscle oxygenation [3, 4 ].”
MethodWu, Y., Song, T., & Xu, G. (2015) · Frontiers of Optoelectronics · doi:10.1007/s12200-015-0532-9 · Cited by 11
Gagnon, D. D., Peltonen, J. E., Rintamäki, H., Gagnon, S. S., Herzig, K., & Kyröläinen, H. (2016) · Journal of Sports Sciences · doi:10.1080/02640414.2016.1245436 · Cited by 10
“As V̇O2 is the most influential factor of skeletal muscle tissue deoxygenation during exercise (Bhambhani, 2004; Hiroyuki et al., 2002), clamping oxygen consumption provided a window of examination on tissue temperature and was not based on fixed external mechanical work.”
BackgroundInfluentialHolmes, M. E., Koutakis, P., & Ismaeel, A. (2022) · European Journal of Applied Physiology · doi:10.1007/s00421-022-04944-0 · Cited by 9
Reinpõld, K., Rannama, I., & Port, K. (2024) · Sports · doi:10.3390/sports12020040 · Cited by 8
“…2 value was achieved, and the signal started to systematically decrease (usually after the first increment at 100 W). during the start of exercise [19], the BP modelling starting point was set at the time when the maximum SmO value was achieved, and the signal started to systematically decrease…”
BackgroundInfluentialBHAMBHANI, Y. N., Gross, D. P., Haykowsky, M. J., & Rashiq, S. (2010) · European Journal of Applied Physiology · doi:10.1007/s00421-009-1332-y · Cited by 7
“The change in muscle oxygenation measured by NIRS reXects the balance between oxygen delivery and removal at the level of the small blood vessels (arterioles, capillaries and venules) and has been used as a surrogate for skeletal muscle oxygen extraction (Bhambhani 2004; Hamaoka et al. 2007).”
BackgroundMethodSelf-citationOsmani, F., Lago-Fuentes, C., Alemany-Iturriaga, J., & Barcala-Furelos, M. (2023) · Frontiers in Physiology · doi:10.3389/fphys.2023.1155037 · Cited by 8
“…resting baseline values iii) leveling off when the participant reaches maximal volitional fatigue during this incremental test, being these results the lowest and below the resting baseline values and, and iv) an increase over baseline values during the first minutes of recovery (Bhambhani, 2004).”
Background
Metadata
- Authors
- Bhambhani, Y. N.
- Affiliations
- University of Alberta (CA)
- Corresponding author
- Bhambhani, Yagesh N.
- Venue
- Canadian Journal of Applied Physiology
- Publisher
- Canadian Science Publishing
- Published
- 2004-08-01
- Volume
- 29
- Issue
- 4
- Pages
- 504-523
- ISSN
- 1066-7814 (ISSN-L)
- OpenAlex
- W2072612155
- Cited by
- 149
- References
- 54
- Citations by year
- 2026: 3 · 2025: 3 · 2024: 6 · 2023: 7 · 2022: 6 · 2021: 5 · 2020: 7 · 2019: 6 · 2018: 4 · 2017: 8 · 2016: 5 · 2015: 6 · 2014: 5 · 2013: 5 · 2012: 15
- FWCI
- 1.14
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.nrcresearchpress.com/page/about/CorporateTextAndDataMining (tdm)
- Locations
- Canadian Journal of Applied Physiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
- Keywords
- muscle oxygenation, muscle deoxygenation, near-infrared spectroscopy, dynamic exercise, lactate threshold, ventilatory threshold, steady-state oxygen uptake, muscle blood volume, aging, sex differences, biceps brachii, vastus lateralis, arm cranking, leg cycling, Wingate test, high-intensity exercise, aerobic metabolism
- MeSH terms
- Adipose Tissue, Humans, Oxygen Consumption, Exercise, Exercise Tolerance, Muscle, Skeletal, Spectroscopy, Near-Infrared
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.