Advances in Paper-Based Analytical Devices
The DOI matches its Crossref record; 55 of the 55 references it cites were found in a registry or an index.
Abstract
Microfluidic paper-based analytical devices (μPADs) are the newest generation of lab-on-a-chip devices and have made significant strides in both our understanding of fundamental behavior and performance characteristics and expansion of their applications. μPADs have become useful analytical techniques for environmental analysis in addition to their more common application as medical point-of-care devices. Although the most common method for device fabrication is wax printing, numerous other techniques exist and have helped address factors ranging from solvent compatibility to improved device function. This review highlights recent reports of fabrication and design, modes of detection, and broad applications of μPADs. Such advances have enabled μPADs to be used in field and laboratory studies to address critical needs in fast, cheaper measurement technologies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Patterned Paper as a Platform for Inexpensive, Low‐Volume, Portable Bioassays
Martinez, A. W., Phillips, S. T., Butte, M. J., & Whitesides, G. M. (2007) · Angewandte Chemie International Edition · doi:10.1002/anie.200603817 · Cited by 2,874
A dot-immunobinding assay for monoclonal and other antibodies
Hawkes, R., Niday, E., & Gordon, J. (1982) · Analytical Biochemistry · doi:10.1016/0003-2697(82)90677-7 · Cited by 2,174
Kirk, M. D., Pires, S. M., Black, R. E., Caipo, M., Crump, J. A., Devleesschauwer, B., Döpfer, D., Fazil, A., Fischer-Walker, C. L., Hald, T., et al. (2015) · PLoS Medicine · doi:10.1371/journal.pmed.1001921 · Cited by 1,625 · cited 2×
“The US Centers for Disease Control and Prevention (CDC) reported that half of adults in the United States are affected by chronic diseases, accounting for 75% of all health care costs (69).”
BackgroundUnderstanding Wax Printing: A Simple Micropatterning Process for Paper-Based Microfluidics
Carrilho, E., Martinez, A. W., & Whitesides, G. M. (2009) · Analytical Chemistry · doi:10.1021/ac901071p · Cited by 1,612
Rapid, Low-Cost Detection of Zika Virus Using Programmable Biomolecular Components
Pardee, K., Green, A. A., Takahashi, M. K., Braff, D., Lambert, G., Lee, J. W., Ferrante, T., Ma, D., Donghia, N., Fan, M., et al. (2016) · Cell · doi:10.1016/j.cell.2016.04.059 · Cited by 1,439
Electrochemical Detection for Paper-Based Microfluidics
Dungchai, W., Chailapakul, O., & Henry, C. S. (2009) · Analytical Chemistry · doi:10.1021/ac9007573 · Cited by 1,224
Self-citationPoint-of-Care Diagnostics for Global Health
Yager, P., Domingo, G. J., & Gerdes, J. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160524 · Cited by 1,076
A perspective on paper-based microfluidics: Current status and future trends
Li, X., Ballerini, D. R., & Shen, W. (2012) · Biomicrofluidics · doi:10.1063/1.3687398 · Cited by 813
Inflammation and atherosclerosis: role of C-Reactive protein in risk assessment
Libby, P., & Ridker, P. M. (2004) · The American Journal of Medicine · doi:10.1016/j.amjmed.2004.02.006 · Cited by 595
Surveillance for Foodborne Disease Outbreaks — United States, 2009–2015
Dewey-Mattia, D., Manikonda, K., Hall, A. J., Wise, M. E., & Crowe, S. J. (2018) · MMWR. Surveillance Summaries · doi:10.15585/mmwr.ss6710a1 · Cited by 567
Paper-Based Microfluidic Devices: Emerging Themes and Applications
Yang, Y., Noviana, E., Nguyen, M. P., Geiss, B. J., Dandy, D. S., & Henry, C. S. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04581 · Cited by 501
Self-citationIntegration of paper-based microfluidic devices with commercial electrochemical readers
Nie, Z., Deiss, F., Liu, X., Akbulut, O., & Whitesides, G. M. (2010) · Lab on a Chip · doi:10.1039/c0lc00237b · Cited by 481
Wu, W., Wu, P., Yang, F., Sun, D.-L., Zhang, D.-X., & Zhou, Y.-K. (2018) · Science of The Total Environment · doi:10.1016/j.scitotenv.2018.02.183 · Cited by 429
World Trade Organization (2004) · World Trade Report · doi:10.30875/b469a751-en · Cited by 394
Flexographically Printed Fluidic Structures in Paper
Olkkonen, J., Lehtinen, K., & Erho, T. (2010) · Analytical Chemistry · doi:10.1021/ac1027066 · Cited by 369
Simple, distance-based measurement for paper analytical devices
Cate, D. M., Dungchai, W., Cunningham, J. C., Volckens, J., & Henry, C. S. (2013) · Lab on a Chip · doi:10.1039/c3lc50072a · Cited by 348
Self-citationYu, J., Ge, L., Huang, J., Wang, S., & Ge, S. (2011) · Lab on a Chip · doi:10.1039/c0lc00524j · Cited by 327
Origami multiple paper-based electrochemical biosensors for pesticide detection
Arduini, F., Cinti, S., Caratelli, V., Amendola, L., Palleschi, G., & Moscone, D. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.10.014 · Cited by 322
Paper-based analytical devices for environmental analysis
Meredith, N. A., Quinn, C., Cate, D. M., Reilly, T. H., Volckens, J., & Henry, C. S. (2016) · The Analyst · doi:10.1039/c5an02572a · Cited by 299
Self-citationMultiplexed paper analytical device for quantification of metals using distance-based detection
Cate, D. M., Noblitt, S. D., Volckens, J., & Henry, C. S. (2015) · Lab on a Chip · doi:10.1039/c5lc00364d · Cited by 250
Self-citationQi, J., Li, B., Wang, X., Zhang, Z., Wang, Z., Han, J., & Chen, L. (2017) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2017.05.052 · Cited by 244
Water Analysis: Emerging Contaminants and Current Issues
Richardson, S. D. (2007) · Analytical Chemistry · doi:10.1021/ac070719q · Cited by 233
Tools for water quality monitoring and mapping using paper-based sensors and cell phones
Sicard, C., Glen, C., Aubie, B., Wallace, D., Jahanshahi-Anbuhi, S., Pennings, K., Daigger, G. T., Pelton, R., Brennan, J. D., & Filipe, C. D. M. (2015) · Water Research · doi:10.1016/j.watres.2014.12.005 · Cited by 216
Srisa-Art, M., Boehle, K. E., Geiss, B. J., & Henry, C. S. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04628 · Cited by 216
Self-citationLópez-Marzo, A. M., & Merkoçi, A. (2016) · Lab on a Chip · doi:10.1039/c6lc00737f · Cited by 215
Microfluidic Lab-on-a-Chip Platforms: Requirements, Characteristics and Applications
Mark, D., Haeberle, S., Roth, G., Von Stetten, F., & Zengerle, R. (2010) · NATO Science for Peace and Security Series A: Chemistry and Biology · doi:10.1007/978-90-481-9029-4_17 · Cited by 214
Wei, X., Tian, T., Jia, S., Zhu, Z., Ma, Y., Sun, J., Lin, Z., & Yang, C. J. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b04294 · Cited by 210
Novel reagentless paper-based screen-printed electrochemical sensor to detect phosphate
Cinti, S., Talarico, D., Palleschi, G., Moscone, D., & Arduini, F. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2016.03.011 · Cited by 195
Electrochemical paper‐based microfluidic devices
Adkins, J., Boehle, K., & Henry, C. (2015) · ELECTROPHORESIS · doi:10.1002/elps.201500084 · Cited by 194
Self-citationRapid and low-cost biosensor for the detection of Staphylococcus aureus
Suaifan, G. A. R. Y., Alhogail, S., & Zourob, M. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.11.047 · Cited by 184
Qi, J., Li, B., Wang, X., Fu, L., Luo, L., & Chen, L. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b01291 · Cited by 183
Semiquantitative Specific Test Paper for Glucose in Urine
Comer, J. P. (1956) · Analytical Chemistry · doi:10.1021/ac60119a030 · Cited by 177
Rapid fabrication of pressure-driven open-channel microfluidic devices in omniphobic RF paper
Glavan, A. C., Martinez, R. V., Maxwell, E. J., Subramaniam, A. B., Nunes, R. M. D., Soh, S., & Whitesides, G. M. (2013) · Lab on a Chip · doi:10.1039/c3lc50371b · Cited by 167
Maejima, K., Tomikawa, S., Suzuki, K., & Citterio, D. (2013) · RSC Advances · doi:10.1039/c3ra40828k · Cited by 165
Ochoa‐Hueso, R., Munzi, S., Alonso, R., Arróniz‐Crespo, M., Àvila, A., Bermejo, V., Bobbink, R., Branquinho, C., Concostrina‐Zubiri, L., Cruz, C., et al. (2017) · Environmental Pollution · doi:10.1016/j.envpol.2017.04.062 · Cited by 149
A wearable origami-like paper-based electrochemical biosensor for sulfur mustard detection
Colozza, N., Kehe, K., Dionisi, G., Popp, T., Tsoutsoulopoulos, A., Steinritz, D., Moscone, D., & Arduini, F. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.01.002 · Cited by 139
Asano, H., & Shiraishi, Y. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.04.014 · Cited by 137
Nanomaterials-modified cellulose paper as a platform for biosensing applications
Ge, S., Zhang, L., Zhang, Y., Lan, F., Yan, M., & Yu, J. (2017) · Nanoscale · doi:10.1039/c6nr08846e · Cited by 122
Chiang, C.-K., Kurniawan, A., Kao, C., & Wang, M. (2018) · Talanta · doi:10.1016/j.talanta.2018.10.104 · Cited by 122
Microwave-assisted digestion of organic samples: How simple can it become?
Nóbrega, J. A., Pirola, C., Fialho, L. L., Rota, G., Jordão, C. E. K. M. A. D. C., & Pollo, F. (2012) · Talanta · doi:10.1016/j.talanta.2012.06.079 · Cited by 107
Kazi, T. G., Jamali, M. K., Arain, M. B., Afridi, H. I., Jalbani, N. B., Sarfraz, R. A., & Ansari, R. (2008) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2008.04.103 · Cited by 98
Kaneta, T., Alahmad, W., & Varanusupakul, P. (2018) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2018.1457045 · Cited by 93
Zhao, W. M., Zhang, W., Zhang, Z., He, R., Lin, Y., Xie, M., Wang, H., & Pang, D. (2012) · Analytical Chemistry · doi:10.1021/ac203102u · Cited by 84
Mobile phone-based electrochemiluminescence sensing exploiting the ‘USB On-The-Go’ protocol
Doeven, E. H., Barbante, G. J., Harsant, A. J., Donnelly, P. S., Connell, T. U., Hogan, C. F., & Francis, P. S. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.04.087 · Cited by 84
Paper strip-embedded graphene quantum dots: a screening device with a smartphone readout
Álvarez-Diduk, R., Orozco, J., & Merkoçi, A. (2017) · Scientific Reports · doi:10.1038/s41598-017-01134-3 · Cited by 76
Chen, C., Wang, P., Yen, Y.-C., Lin, H.-L., Fan, Y.-C., Wu, S., & Chen, C.-F. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.11.071 · Cited by 65
Portable Colorimetric Paper-Based Biosensing Device for the Assessment of Bisphenol A in Indoor Dust
Alkasir, R. S. J., Rossner, A., & Andreescu, S. (2015) · Environmental Science & Technology · doi:10.1021/acs.est.5b01588 · Cited by 62
Kim, H. J., Kim, Y., Park, S. J., Kwon, C., & Noh, H. (2018) · BioChip Journal · doi:10.1007/s13206-018-2404-z · Cited by 62
Low-cost fabrication of a paper-based microfluidic using a folded pattern paper
Xie, L., Zi, X., Zeng, H., Sun, J., Xu, L., & Chen, S. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2018.12.001 · Cited by 54
An animal cell culture monitoring system using a smartphone-mountable paper-based analytical device
Im, S. H., Kim, K. R., Park, Y. M., Yoon, J. H., Hong, J. W., & Yoon, H. C. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.01.121 · Cited by 47
A folding affinity paper-based electrochemical impedance device for cardiovascular risk assessment
Boonyasit, Y., Chailapakul, O., & Laiwattanapaisal, W. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.09.031 · Cited by 45
A nanocomposite-based biosensor for bovine haptoglobin on a 3D paper-based analytical device
Weng, X., Ahmed, S. R., & Neethirajan, S. R. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.03.061 · Cited by 37
Nechaeva, D., Shishov, A. Y., Ermakov, S., & Bulatov, A. V. (2018) · Talanta · doi:10.1016/j.talanta.2018.02.074 · Cited by 33
Paper-based point-of-care testing for diagnosis of dengue infections
Choi, J. R., Hu, J., Wang, S., Yang, H., Abas, W. A. B. W., Pingguan‐Murphy, B., & Xu, F. (2016) · Critical Reviews in Biotechnology · doi:10.3109/07388551.2016.1139541 · Cited by 32
Lee, S., Park, J., Park, J., et al. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.06.059 · Cited by 18
Cited by
Microfluidic Paper-Based Analytical Devices: From Design to Applications
Noviana, E., Ozer, T., Carrell, C. S., Link, J. S., McMahon, C., Jang, I., & Henry, C. S. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01335 · Cited by 631
Self-citationRecent Advances in Microfluidic Technology for Bioanalysis and Diagnostics
Berlanda, S. F., Breitfeld, M., Dietsche, C. L., & Dittrich, P. S. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.0c04366 · Cited by 305
Microfluidic chain reaction of structurally programmed capillary flow events
Yafia, M., Ymbern, O., Olanrewaju, A. O., Parandakh, A., Sohrabi Kashani, A., Renault, J., Jin, Z., Kim, G., Ng, A., & Juncker, D. (2022) · Nature · doi:10.1038/s41586-022-04683-4 · Cited by 203
Metadata
- Authors
- Ozer, T., McMahon, C., & Henry, C. S.
- Venue
- Annual Review of Analytical Chemistry
- Publisher
- Annual Reviews
- Published
- 2020-06-12
- Volume
- 13
- Issue
- 1
- Pages
- 85-109
- ISSN
- 1936-1327 (ISSN-L)
- 1936-1335
- OpenAlex
- W3002047737
- Cited by
- 330
- References
- 55
- FWCI
- 5.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.