Lessons in Fluctuation Correlation Spectroscopy
Open accessThe DOI matches its Crossref record; 76 of the 76 references it cites were found in a registry or an index.
Abstract
Molecular diffusion and transport processes are fundamental in physical, chemical, and biological systems. Current approaches to measuring molecular transport in cells and tissues based on perturbation methods, e.g., fluorescence recovery after photobleaching, are invasive; single-point fluctuation correlation methods are local; and single-particle tracking requires the observation of isolated particles for relatively long periods of time. We discuss here the detection of molecular transport by exploiting spatiotemporal correlations measured among points at large distances (>1 μm). We illustrate the evolution of the conceptual framework that started with single-point fluorescence fluctuation analysis based on the transit of fluorescent molecules through a small volume of illumination. This idea has evolved to include the measurement of fluctuations at many locations in the sample using microscopy imaging methods. Image fluctuation analysis has become a rich and powerful technique that can be used to extract information about the spatial distribution of molecular concentration and transport in cells and tissues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dynamic Light Scattering: Applications of Photon Correlation Spectroscopy
(1985) · Springer eBooks · doi:10.1007/978-1-4613-2389-1 · Cited by 4,856
Evidence for the Formation of Symmetric and Asymmetric DLPC-DAPC Lipid Bilayer Domains
Ritter, M., Schmidt, S., Jakab, M., Paulmichl, M., & Henderson, R. (2013) · Cellular Physiology and Biochemistry · doi:10.1159/000350122 · Cited by 3,923
SINGLE-PARTICLE TRACKING:Applications to Membrane Dynamics
Saxton, M. J., & Jacobson, K. (1997) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.26.1.373 · Cited by 1,810 · cited 2×
“For example, Saxton & Jacobson (88) obtained a closed expression in the context of the diffusion of molecules in membranes.”
Thermodynamic Fluctuations in a Reacting System—Measurement by Fluorescence Correlation Spectroscopy
Magde, D., Elson, E., & Webb, W. W. (1972) · Physical Review Letters · doi:10.1103/physrevlett.29.705 · Cited by 1,753 · cited 1×
“(8) in 1972 for the determination of binding of ethidium bromide to double-stranded DNA.”
BackgroundFluorescence correlation spectroscopy. II. An experimental realization
Magde, D., Elson, E. L., & Webb, W. W. (1974) · Biopolymers · doi:10.1002/bip.1974.360130103 · Cited by 1,512 · cited 7×
“pCF(10) occurs at a different time depending on the diffusion coefficient.”
BackgroundMethodInfluentialFluorescence correlation spectroscopy. I. Conceptual basis and theory
Elson, E. L., & Magde, D. (1974) · Biopolymers · doi:10.1002/bip.1974.360130102 · Cited by 1,436
Sorting single molecules: application to diagnostics and evolutionary biotechnology.
Eigen, M., & Rigler, R. (1994) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.91.13.5740 · Cited by 956 · cited 2×
“This technical limitation was removed by the pioneering work of Eigen & Rigler (33) using confocal pinholes.”
Takahashi, K., & Sakurai, K. (2020) · Drug Delivery System · doi:10.2745/dds.35.332 · Cited by 917
Schwille, P., Meyer-Almes, F. J., & Rigler, R. (1997) · Biophysical Journal · doi:10.1016/s0006-3495(97)78833-7 · Cited by 817 · cited 1×
“The cross-correlation method is also common in DLS, but the use of coincidence analysis to detect the formation of molecular complexes is unique to FCS (34– 43).”
Analysis of Single-Molecule FRET Trajectories Using Hidden Markov Modeling
McKinney, S. A., Joo, C., & Ha, T. (2006) · Biophysical Journal · doi:10.1529/biophysj.106.082487 · Cited by 760 · cited 1×
“…ACF approach, the fluctuation record is a time series, and other approaches based, for example, on hidden Markov chains and other statistical analysis methods have been successfully used to extract information about the states and the rates of transition between states of a chemical system (25–32).”
Fluorescence Correlation Spectroscopy
(2011) · SpringerReference · doi:10.1007/springerreference_33960 · Cited by 714
The Photon Counting Histogram in Fluorescence Fluctuation Spectroscopy
Chen, Y., Müller, J. D., So, P. T. C., & Gratton, E. (1999) · Biophysical Journal · doi:10.1016/s0006-3495(99)76912-2 · Cited by 682 · cited 1×
“We understand the statistics of a photon’s time of arrival and how these statistics relate to underlying chemical and physical processes (19).”
BackgroundSelf-citationFluorescence cross-correlation spectroscopy in living cells
Bacia, K., Kim, S. A., & Schwille, P. (2006) · Nature Methods · doi:10.1038/nmeth822 · Cited by 617
Imaging of single molecule diffusion.
Schmidt, T., Schütz, G. J., Baumgartner, W., Gruber, H. J., & Schindler, H. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.7.2926 · Cited by 613 · cited 1×
“This probability has been previously evaluated by several authors (88, 89).”
Fluorescence Correlation Spectroscopy: Novel Variations of an Established Technique
Haustein, E., & Schwille, P. (2007) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.36.040306.132612 · Cited by 548
Dynamics of fluorescence marker concentration as a probe of mobility
Koppel, D. E., Axelrod, D., Schlessinger, J., Elson, E. L., & Webb, W. W. (1976) · Biophysical Journal · doi:10.1016/s0006-3495(76)85776-1 · Cited by 481 · cited 1×
“Later the effect of diffusion on the fluorescence fluctuations was discussed (4, 9–12).”
Mapping the Number of Molecules and Brightness in the Laser Scanning Microscope
Digman, M. A., Dalal, R., Horwitz, A. F., & Gratton, E. (2008) · Biophysical Journal · doi:10.1529/biophysj.107.114645 · Cited by 475
Self-citationMeasuring Fast Dynamics in Solutions and Cells with a Laser Scanning Microscope
Digman, M. A., Brown, C. M., Sengupta, P., Wiseman, P. W., Horwitz, A. R., & Gratton, E. (2005) · Biophysical Journal · doi:10.1529/biophysj.105.062836 · Cited by 462 · cited 1×
“During the same period, in our lab we exploited the concept of rapidly scanning a path in the sample so that the time and the space variables can be simultaneously sampled (69, 70).”
MethodSelf-citationStatistical accuracy in fluorescence correlation spectroscopy
Koppel, D. E. (1974) · Physical Review A · doi:10.1103/physreva.10.1938 · Cited by 450 · cited 2×
“A few years after its introduction, most of the theory of single-point FCS was developed together with the understanding of the technology needed to record and analyze the fluctuations (13).”
BackgroundFluorescence correlation spectroscopy in living cells
Kim, S. A., Heinze, K. G., & Schwille, P. (2007) · Nature Methods · doi:10.1038/nmeth1104 · Cited by 444
Petersen, N. O., Höddelius, P., Wiseman, P. W., Seger, O., & Magnusson, K. (1993) · Biophysical Journal · doi:10.1016/s0006-3495(93)81173-1 · Cited by 443 · cited 1×
“Petersen and colleagues (53–55) exploited this principle to obtain the average size of large protein aggregates in biological membranes.”
Fluorescence Correlation Spectroscopy: Theory and Applications
Rigler, R., & Elson, E. S. (2001) · Springer Series in Chemical Physics · doi:10.1007/978-3-642-59542-4 · Cited by 413
Hebert, B., Costantino, S., & Wiseman, P. W. (2005) · Biophysical Journal · doi:10.1529/biophysj.104.054874 · Cited by 406
Dertinger, T., Pacheco, V., von der Hocht, I., Hartmann, R., Gregor, I., & Enderlein, J. (2007) · ChemPhysChem · doi:10.1002/cphc.200600638 · Cited by 345 · cited 1×
“Conceptually, scanning FCS is different from the use of an arbitrary shape or size for the volume of illumination such as the dual-foci method (1, 52), as different volumes are excited at different times in scanning FCS.”
MethodKolin, D. L., & Wiseman, P. W. (2007) · Cell Biochemistry and Biophysics · doi:10.1007/s12013-007-9000-5 · Cited by 277 · cited 1×
“By this time, the idea of exploiting spatio-temporal correlation to determine diffusion and aggregation was in full development, mainly because of the efforts of the group of Petersen and Wiseman (56–68).”
Accurate Single-Molecule FRET Studies Using Multiparameter Fluorescence Detection
Sisamakis, E., Valeri, A., Kalinin, S., Rothwell, P. J., & Seidel, C. A. M. (2010) · Methods in Enzymology · doi:10.1016/s0076-6879(10)75018-7 · Cited by 268
Bacia, K., & Schwille, P. (2003) · Methods · doi:10.1016/s1046-2023(02)00291-8 · Cited by 245
Wiseman, P. W., Brown, C. M., Webb, D. J., Hebert, B., Johnson, N. L., Squier, J. A., Ellisman, M. H., & Horwitz, A. F. (2004) · Journal of Cell Science · doi:10.1242/jcs.01416 · Cited by 232
Digman, M. A., Sengupta, P., Wiseman, P. W., Brown, C. M., Horwitz, A. R., & Gratton, E. (2005) · Biophysical Journal · doi:10.1529/biophysj.105.061788 · Cited by 221 · cited 1×
“During the same period, in our lab we exploited the concept of rapidly scanning a path in the sample so that the time and the space variables can be simultaneously sampled (69, 70).”
MethodSelf-citationWidengren, J., Kudryavtsev, V., Antonik, M., Berger, S., Gerken, M., & Seidel, C. A. M. (2006) · Analytical Chemistry · doi:10.1021/ac0522759 · Cited by 217 · cited 1×
“…ACF approach, the fluctuation record is a time series, and other approaches based, for example, on hidden Markov chains and other statistical analysis methods have been successfully used to extract information about the states and the rates of transition between states of a chemical system (25–32).”
Probing protein oligomerization in living cells with fluorescence fluctuation spectroscopy
Chen, Y., Wei, L.-N., & Müller, J. D. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2533045100 · Cited by 217
Kalinin, S., Valeri, A., Antonik, M., Felekyan, S., & Seidel, C. A. M. (2010) · The Journal of Physical Chemistry B · doi:10.1021/jp102156t · Cited by 195
BROWN, C. M., DALAL, R. B., HEBERT, B., DIGMAN, M. A., HORWITZ, A. R., & GRATTON, E. (2008) · Journal of Microscopy · doi:10.1111/j.1365-2818.2007.01871.x · Cited by 193
Self-citationAccurate Determination of Membrane Dynamics with Line-Scan FCS
Ries, J., Chiantia, S., & Schwille, P. (2009) · Biophysical Journal · doi:10.1016/j.bpj.2008.12.3888 · Cited by 193
Two-Dimensional Fluorescence Intensity Distribution Analysis: Theory and Applications
Kask, P., Palo, K., Fay, N., Brand, L., Mets, Ü., Ullmann, D., Jungmann, J., Pschorr, J., & Gall, K. (2000) · Biophysical Journal · doi:10.1016/s0006-3495(00)76722-1 · Cited by 178 · cited 1×
“…the temporal spectrum of the fluctuation, which is obtained using the autocorrelation function (ACF) approach, and the other is the analysis of the amplitude spectrum, which is obtained using the photon-counting histogram approach or fluctuation intensity distribution analysis (Figure 3) (17–24).”
Single-Molecule Spectroscopy and Imaging of Biomolecules in Living Cells
Lord, S. J., Lee, H. D., & Moerner, W. E. (2010) · Analytical Chemistry · doi:10.1021/ac9024889 · Cited by 175 · cited 1×
“The cross-correlation method is also common in DLS, but the use of coincidence analysis to detect the formation of molecular complexes is unique to FCS (34– 43).”
Two‐photon image correlation spectroscopy and image cross‐correlation spectroscopy
Wiseman, P. W., Squier, J. A., Ellisman, M. H., & Wilson, K. R. (2000) · Journal of Microscopy · doi:10.1046/j.1365-2818.2000.00736.x · Cited by 175
Scanning fluorescence correlation spectroscopy. I. Theory and simulation of aggregation measurements
Petersen, N. O. (1986) · Biophysical Journal · doi:10.1016/s0006-3495(86)83709-2 · Cited by 175
Imaging Barriers to Diffusion by Pair Correlation Functions
Digman, M. A., & Gratton, E. (2009) · Biophysical Journal · doi:10.1016/j.bpj.2009.04.048 · Cited by 173 · cited 1×
“The basic idea of the pCF method is to statistically follow the same fluorescent molecule diffusing in the cell (2, 85).”
MethodSelf-citationProbing the integrin-actin linkage using high-resolution protein velocity mapping
Brown, C. M., Hebert, B., Kolin, D. L., Zareno, J., Whitmore, L., Horwitz, A. R., & Wiseman, P. W. (2006) · Journal of Cell Science · doi:10.1242/jcs.03321 · Cited by 167
Berland, K. M., So, P. T. C., Chen, Y., Mantulin, W. W., & Gratton, E. (1996) · Biophysical Journal · doi:10.1016/s0006-3495(96)79242-1 · Cited by 161 · cited 2×
“Although this principle was known since the early days, the technical realization of a practical system based on rapidly scanning a path in the sample made the technology easy to implement (46).”
BackgroundSelf-citationStoichiometry of molecular complexes at adhesions in living cells
Digman, M. A., Wiseman, P. W., Choi, C. K., Horwitz, A. R., & Gratton, E. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0806036106 · Cited by 160 · cited 1×
“It is noteworthy to mention that we have developed the number and brightness approach, which is based on pixel resolution for methods used to extract information on the amplitude of the fluctuations (69–71”
Self-citationPalmer, A. G., & Thompson, N. L. (1987) · Biophysical Journal · doi:10.1016/s0006-3495(87)83213-7 · Cited by 159 · cited 1×
“Briefly, the FCS analysis is traditionally done using correlation functions, although other approaches have been proposed (14–16).”
Wiseman, P. W., & Petersen, N. O. (1999) · Biophysical Journal · doi:10.1016/s0006-3495(99)77260-7 · Cited by 159
Paxillin Dynamics Measured during Adhesion Assembly and Disassembly by Correlation Spectroscopy
Digman, M. A., Brown, C. M., Horwitz, A. R., Mantulin, W. W., & Gratton, E. (2007) · Biophysical Journal · doi:10.1529/biophysj.107.104984 · Cited by 150
Self-citationPalo, K., Mets, Ü., Jäger, S., Kask, P., & Gall, K. (2000) · Biophysical Journal · doi:10.1016/s0006-3495(00)76523-4 · Cited by 149
Modular scanning FCS quantifies receptor-ligand interactions in living multicellular organisms
Ries, J., Yu, S. R., Burkhardt, M., Brand, M., & Schwille, P. (2009) · Nature Methods · doi:10.1038/nmeth.1355 · Cited by 148
Digman, M. A., Wiseman, P. W., Horwitz, A. R., & Gratton, E. (2009) · Biophysical Journal · doi:10.1016/j.bpj.2008.09.051 · Cited by 135
Self-citationAnalysis of diffusion and binding in cells using the RICS approach
Digman, M. A., & Gratton, E. (2008) · Microscopy Research and Technique · doi:10.1002/jemt.20655 · Cited by 125
Self-citationTwo-Photon Cross-Correlation Analysis of Intracellular Reactions with Variable Stoichiometry
Kim, S. A., Heinze, K. G., Bacia, K., Waxham, M. N., & Schwille, P. (2005) · Biophysical Journal · doi:10.1529/biophysj.104.055319 · Cited by 123
Determination of molecular weights by fluctuation spectroscopy: application to DNA.
Weissman, M. B., Schindler, H., & Fehér, G. (1976) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.73.8.2776 · Cited by 123 · cited 1×
“Early in the field’s development, it was understood that by moving the illumination volume in a periodic pattern in the sample at a rate such that the molecules will not move much during a period, the record of the intensity fluctuations along the path will contain spatial information about the location where the fluc…”
BackgroundOssato, G., Digman, M. A., Aiken, C. T., Lukácsovich, T., Marsh, J., & Gratton, E. (2010) · Biophysical Journal · doi:10.1016/j.bpj.2010.02.058 · Cited by 112
Self-citationDalal, R. B., Digman, M. A., Horwitz, A. F., Vetri, V., & Gratton, E. (2007) · Microscopy Research and Technique · doi:10.1002/jemt.20526 · Cited by 110
Self-citationMembrane Lateral Diffusion and Capture of CFTR within Transient Confinement Zones
Bates, I. R., Hébert, B., Luo, Y., Liao, J., Bachir, A. I., Kolin, D. L., Wiseman, P. W., & Hanrahan, J. W. (2006) · Biophysical Journal · doi:10.1529/biophysj.106.084830 · Cited by 103
Kolin, D. L., Ronis, D., & Wiseman, P. W. (2006) · Biophysical Journal · doi:10.1529/biophysj.106.082768 · Cited by 102
Heinze, K. G., Jahnz, M., & Schwille, P. (2004) · Biophysical Journal · doi:10.1016/s0006-3495(04)74129-6 · Cited by 102
Quick tour of fluorescence correlation spectroscopy from its inception
Elson, E. L. (2004) · Journal of Biomedical Optics · doi:10.1117/1.1779234 · Cited by 98 · cited 1×
“(b) From the total intensity carpet we select the nuclear compartment, calculate the autocorrelation function (ACF) (right panel ), and (c) the pair correlation function (pCF) function at a distance that entirely correlates with the cytoplasm [in this case pCF(12) for columns 3–12].”
BackgroundAccuracy and Dynamic Range of Spatial Image Correlation and Cross-Correlation Spectroscopy
Costantino, S., Comeau, J., Kolin, D. L., & Wiseman, P. W. (2005) · Biophysical Journal · doi:10.1529/biophysj.104.057364 · Cited by 98
Kalinin, S., Felekyan, S., Antonik, M. D., & Seidel, C. A. M. (2007) · The Journal of Physical Chemistry B · doi:10.1021/jp072293p · Cited by 86
Cardarelli, F., & Gratton, E. (2010) · PLoS ONE · doi:10.1371/journal.pone.0010475 · Cited by 80 · cited 2×
“The complete analysis of this case has recently been published (85).”
BackgroundMethodSelf-citationTheory of sample translation in fluorescence correlation spectroscopy
Palmer, A. G. I., & Thompson, N. L. (1987) · Biophysical Journal · doi:10.1016/s0006-3495(87)83340-4 · Cited by 80 · cited 1×
“Briefly, the FCS analysis is traditionally done using correlation functions, although other approaches have been proposed (14–16).”
Palo, K., Brand, L., Eggeling, C., Jäger, S., Kask, P., & Gall, K. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75195-3 · Cited by 78
Kalinin, S., Felekyan, S., Valeri, A., & Seidel, C. A. M. (2008) · The Journal of Physical Chemistry B · doi:10.1021/jp711942q · Cited by 76
Multiparameter fluorescence imagespectroscopy to study molecular interactions
Weidtkamp‐Peters, S., Felekyan, S., Bleckmann, A., Simon, R. G., Becker, W. H., Kühnemuth, R., & Seidel, C. A. M. (2009) · Photochemical & Photobiological Sciences · doi:10.1039/b903245m · Cited by 71
The optics and performance of dual-focus fluorescence correlation spectroscopy
Dertinger, T., Loman, A., Ewers, B., Müller, C. B., Krämer, B., & Enderlein, J. (2008) · Optics Express · doi:10.1364/oe.16.014353 · Cited by 71 · cited 3×
“Conceptually, scanning FCS is different from the use of an arbitrary shape or size for the volume of illumination such as the dual-foci method (1, 52), as different volumes are excited at different times in scanning FCS.”
MethodAnalysis of membrane protein cluster densities and sizes in situ by image correlation spectroscopy
Petersen, N. O., Brown, C. M., Kaminski, A., Rocheleau, J. V., Srivastava, M., & Wiseman, P. W. (1999) · Faraday Discussions · doi:10.1039/a806677i · Cited by 66 · cited 1×
“Petersen and colleagues (53–55) exploited this principle to obtain the average size of large protein aggregates in biological membranes.”
Spatial Diffusivity and Availability of Intracellular Calmodulin
Sanabria, H., Digman, M. A., Gratton, E., & Waxham, M. N. (2008) · Biophysical Journal · doi:10.1529/biophysj.108.138974 · Cited by 52
Self-citationWiseman, P. W., Höddelius, P., Petersen, N. O., & Magnusson, K. (1997) · FEBS Letters · doi:10.1016/s0014-5793(96)01429-9 · Cited by 49
Scanning Fluorescence Correlation Spectroscopy
Petrášek, Z., & Schwille, P. (2007) · Springer series in biophysics · doi:10.1007/978-3-540-73924-1_4 · Cited by 35
Durisic, N., Bachir, A. I., Kolin, D. L., Hébert, B., Lagerholm, B. C., Grütter, P., & Wiseman, P. W. (2007) · Biophysical Journal · doi:10.1529/biophysj.107.106864 · Cited by 31
Krishnan, K., Holub, O., Gratton, E., Clayton, A. H. A., Cody, S. H., & Moens, P. (2009) · Biophysical Journal · doi:10.1016/j.bpj.2009.03.034 · Cited by 30 · cited 1×
“This approach is called scanning FCS, and it is practiced today in several labs (47–51).”
Self-citationCounting dendritic spines in brain tissue slices by image correlation spectroscopy analysis
Wiseman, P. W., Capani, F., Squier, J. A., & Martone, M. E. (2002) · Journal of Microscopy · doi:10.1046/j.0022-2720.2001.00985.x · Cited by 28
What it means to measure a single molecule in a solution by fluorescence fluctuation spectroscopy
Földes‐Papp, Z. (2006) · Experimental and Molecular Pathology · doi:10.1016/j.yexmp.2006.01.001 · Cited by 27
Földes‐Papp, Z. (2006) · Experimental and Molecular Pathology · doi:10.1016/j.yexmp.2006.12.002 · Cited by 21
Gaiduk, A., Kühnemuth, R., Felekyan, S., Antonik, M. D., Becker, W. H., Kudryavtsev, V., Sandhagen, C., & Seidel, C. A. M. (2007) · Microscopy Research and Technique · doi:10.1002/jemt.20430 · Cited by 20
A new concept for ultrasensitive fluorescence measurements of molecules in solution and membrane:
Földes‐Papp, Z., Demel, U., & Tilz, G. P. (2004) · Journal of Immunological Methods · doi:10.1016/j.jim.2004.01.007 · Cited by 10
Cited by
DLS and zeta potential – What they are and what they are not?
Bhattacharjee, S. (2016) · Journal of Controlled Release · doi:10.1016/j.jconrel.2016.06.017 · Cited by 4,702
Physicochemical Properties of Cells and Their Effects on Intrinsically Disordered Proteins (IDPs)
Theillet, F.-X., Binolfi, A., Frembgen-Kesner, T., Hingorani, K., Sarkar, M., Kyne, C., Li, C., Crowley, P. B., Gierasch, L., Pielak, G. J., et al. (2014) · Chemical Reviews · doi:10.1021/cr400695p · Cited by 503
Jeyaraj, M., Gurunathan, S., Qasim, M., Kang, M.-H., & Kim, J.-H. (2019) · Nanomaterials · doi:10.3390/nano9121719 · Cited by 481
Lipid and polymer nanoparticles for drug delivery to bacterial biofilms
Forier, K., Raemdonck, K., De Smedt, S. C., Demeester, J., Coenye, T., & Braeckmans, K. (2014) · Journal of Controlled Release · doi:10.1016/j.jconrel.2014.03.055 · Cited by 464
Fluorescence Correlation Spectroscopy: Past, Present, Future
Elson, E. L. (2011) · Biophysical Journal · doi:10.1016/j.bpj.2011.11.012 · Cited by 438
Metadata
- Authors
- Digman, M. A., & Gratton, E.
- Venue
- Annual Review of Physical Chemistry
- Publisher
- Annual Reviews
- Published
- 2011-05-05
- Volume
- 62
- Issue
- 1
- Pages
- 645-668
- ISSN
- 0066-426X (ISSN-L)
- 1545-1593
- OpenAlex
- W2112459741
- Cited by
- 214
- References
- 76
- FWCI
- 1.70
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.