STRUCTURAL STUDIES BY ELECTRON TOMOGRAPHY: From Cells to Molecules
The DOI matches its Crossref record; 85 of the 85 references it cites were found in a registry or an index.
Abstract
▪ Abstract Electron tomography (ET) is uniquely suited to obtain three-dimensional reconstructions of pleomorphic structures, such as cells, organelles or supramolecular assemblies. Although the principles of ET have been known for decades, its use has gathered momentum only in recent years, thanks to technological advances and its combination with improved specimen preparation techniques. The rapid freezing/freeze-substitution preparation is applicable to whole cells and tissues, and it is the method of choice for ET investigations of cellular ultrastructure. The frozen-hydrated preparation provides the best possible structural preservation and allows the imaging of molecules, complexes, and supramolecular assemblies in their native state and their natural environment. Devoid of staining and chemical fixation artifacts, cryo-ET provides a faithful representation of both the surface and internal structure of molecules. In combination with advanced computational methods, such as molecular identification based on pattern recognition techniques, cryo-ET is currently the most promising approach to comprehensively map macromolecular architecture inside cellular tomograms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gordon, R., Bender, R., & Herman, G. T. (1970) · Journal of Theoretical Biology · doi:10.1016/0022-5193(70)90109-8 · Cited by 2,791
Cryo-electron microscopy of vitrified specimens
Dubochet, J., Adrian, M., Chang, J.-J., Homo, J.-C., Lepault, J., McDowall, A. W., & Schultz, P. (1988) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583500004297 · Cited by 2,389
Reconstruction of Three Dimensional Structures from Electron Micrographs
DE ROSIER, D. J., & KLUG, A. (1968) · Nature · doi:10.1038/217130a0 · Cited by 1,345
A TECHNIQUE FOR ULTRACRYOTOMY OF CELL SUSPENSIONS AND TISSUES
Tokuyasu, K. T. (1973) · The Journal of Cell Biology · doi:10.1083/jcb.57.2.551 · Cited by 1,074
A Distinct Pathway Remodels Mitochondrial Cristae and Mobilizes Cytochrome c during Apoptosis
Scorrano, L., Ashiya, M., Buttle, K., Weiler, S., Oakes, S. A., Mannella, C. A., & Korsmeyer, S. J. (2002) · Developmental Cell · doi:10.1016/s1534-5807(01)00116-2 · Cited by 1,072
Dual-Axis Tomography: An Approach with Alignment Methods That Preserve Resolution
Mastronarde, D. N. (1997) · Journal of Structural Biology · doi:10.1006/jsbi.1997.3919 · Cited by 1,057
Crowther, R. A., DeRosier, D. J., & Klug, A. (1970) · Proceedings of the Royal Society of London. A. Mathematical and Physical Sciences · doi:10.1098/rspa.1970.0119 · Cited by 972
Multicolor and Electron Microscopic Imaging of Connexin Trafficking
Gaietta, G., Deerinck, T. J., Adams, S. R., Bouwer, J., Tour, O., Laird, D. W., Sosinsky, G. E., Tsien, R. Y., & Ellisman, M. H. (2002) · Science · doi:10.1126/science.1068793 · Cited by 907
The internal structure of mitochondria
Frey, T. G., & Mannella, C. A. (2000) · Trends in Biochemical Sciences · doi:10.1016/s0968-0004(00)01609-1 · Cited by 900
Macromolecular Architecture in Eukaryotic Cells Visualized by Cryoelectron Tomography
Medalia, O., Weber, I., Frangakis, A. S., Nicastro, D., Gerisch, G., & Baumeister, W. (2002) · Science · doi:10.1126/science.1076184 · Cited by 837
Self-citation
Cited by
Putnam, C. D., Hammel, M., Hura, G. L., & Tainer, J. A. (2007) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583507004635 · Cited by 1,184
Distribution and three-dimensional structure of AIDS virus envelope spikes
Zhu, P., Liu, J., Bess, J., Chertova, E., Lifson, J. D., Grisé, H., Ofek, G. A., Taylor, K. A., & Roux, K. H. (2006) · Nature · doi:10.1038/nature04817 · Cited by 780
Toward High-Performance Polymer Solar Cells: The Importance of Morphology Control
Yang, X., & Loos, J. (2007) · Macromolecules · doi:10.1021/ma0618732 · Cited by 622
Influenza virus pleiomorphy characterized by cryoelectron tomography
Harris, A., Cardone, G., Winkler, D. C., Heymann, J. B., Brecher, M., White, J. M., & Steven, A. C. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0607614103 · Cited by 529
Castaño-Díez, D., Kudryashev, M., Arheit, M., & Stahlberg, H. (2012) · Journal of Structural Biology · doi:10.1016/j.jsb.2011.12.017 · Cited by 509
Electron tomography at 2.4-ångström resolution
Scott, M. C., Chen, C.-C., Mecklenburg, M., Zhu, C., Xu, R., Ercius, P., Dahmen, U., Regan, B. C., & Miao, J. (2012) · Nature · doi:10.1038/nature10934 · Cited by 443
Focused ion beam micromachining of eukaryotic cells for cryoelectron tomography
Rigort, A., Bäuerlein, F. J. B., Villa, E., Eibauer, M., Laugks, T., Baumeister, W., & Plitzko, J. M. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1201333109 · Cited by 430
Self-citationProteome-wide cellular protein concentrations of the human pathogen Leptospira interrogans
Malmström, J., Beck, M., Schmidt, A., Lange, V., Deutsch, E. W., & Aebersold, R. (2009) · Nature · doi:10.1038/nature08184 · Cited by 421
“The extraordinarily thin cross section of L. interrogans cells (100-180 nm) makes them an ideal specimen for cryo electron tomography (cryoET) measurements 13.”
Cryo-electron tomography: The challenge of doing structural biology in situ
Lučić, V., Rigort, A., & Baumeister, W. (2013) · Journal of Cell Biology · doi:10.1083/jcb.201304193 · Cited by 394
Self-citationFilming Biomolecular Processes by High-Speed Atomic Force Microscopy
Ando, T., Uchihashi, T., & Scheuring, S. (2014) · Chemical Reviews · doi:10.1021/cr4003837 · Cited by 392
Morone, N., Fujiwara, T., Murase, K., Kasai, R. S., Ike, H., Yuasa, S., Usukura, J., & Kusumi, A. (2006) · The Journal of Cell Biology · doi:10.1083/jcb.200606007 · Cited by 385
Palenstijn, W. J., Batenburg, K. J., & Sijbers, J. (2011) · Journal of Structural Biology · doi:10.1016/j.jsb.2011.07.017 · Cited by 384
“Electron Tomography is a powerful method for three-dimensional (3D) imaging of complex structures in the cell down to the nanoscale, such as organelles , the cytoskeleton and chromosomes [2] [3].”
MethodCryo-EM: A Unique Tool for the Visualization of Macromolecular Complexity
Nogales, E., & Scheres, S. H. W. (2015) · Molecular Cell · doi:10.1016/j.molcel.2015.02.019 · Cited by 378
The structure of FtsZ filaments in vivo suggests a force‐generating role in cell division
Li, Z., Trimble, M. J., Brun, Y. V., & Jensen, G. J. (2007) · The EMBO Journal · doi:10.1038/sj.emboj.7601895 · Cited by 369
The structural biology of PRRSV
Dokland, T. (2010) · Virus Research · doi:10.1016/j.virusres.2010.07.029 · Cited by 366
(2006) · doi:10.1007/978-0-387-69008-7 · Cited by 357
Isotropic reconstruction for electron tomography with deep learning
Liu, Y.-T., Zhang, H., Wang, H., Tao, C.-L., Bi, G.-Q., & Zhou, Z. H. (2022) · Nature Communications · doi:10.1038/s41467-022-33957-8 · Cited by 349
Snapshots of nuclear pore complexes in action captured by cryo-electron tomography
Beck, M., Lučić, V., Förster, F., Baumeister, W., & Medalia, O. (2007) · Nature · doi:10.1038/nature06170 · Cited by 348
Self-citationThe promise and the challenges of cryo‐electron tomography
Turk, M., & Baumeister, W. (2020) · FEBS Letters · doi:10.1002/1873-3468.13948 · Cited by 333
Self-citationElectron cryotomography of immature HIV‐1 virions reveals the structure of the CA and SP1 Gag shells
Wright, E. R., Schooler, J. B., Ding, H. J., Kieffer, C., Fillmore, C., Sundquist, W. I., & Jensen, G. J. (2007) · The EMBO Journal · doi:10.1038/sj.emboj.7601664 · Cited by 325
“…there was no significant correlation between those standard deviations and the polar angle from the peak to the z-axis, indicating that the ‘missing wedge’ of information inaccessible in electron tomography (Lucic et al, 2005) did not artefactually cause certain regions to appear to lack order.”
Atomic electron tomography: 3D structures without crystals
Miao, J., Ercius, P., & Billinge, S. J. L. (2016) · Science · doi:10.1126/science.aaf2157 · Cited by 319
The Gram-Positive Bacterial Cell Wall
Rohde, M. (2019) · Microbiology Spectrum · doi:10.1128/microbiolspec.gpp3-0044-2018 · Cited by 319
TomoJ: tomography software for three-dimensional reconstruction in transmission electron microscopy
MessaoudiI, C., Boudier, T., Sorzano, C. O. S., & Marco, S. (2007) · BMC Bioinformatics · doi:10.1186/1471-2105-8-288 · Cited by 317
Cryo-Electron Tomography: Can it Reveal the Molecular Sociology of Cells in Atomic Detail?
Beck, M., & Baumeister, W. (2016) · Trends in Cell Biology · doi:10.1016/j.tcb.2016.08.006 · Cited by 316
Self-citationA molecular census of 26 S proteasomes in intact neurons
Asano, S., Fukuda, Y., Beck, F., Aufderheide, A., Förster, F., Danev, R., & Baumeister, W. (2015) · Science · doi:10.1126/science.1261197 · Cited by 311
Self-citationStuder, D., Humbel, B. M., & Chiquet, M. (2008) · Histochemistry and Cell Biology · doi:10.1007/s00418-008-0500-1 · Cited by 286
An introduction to sample preparation and imaging by cryo-electron microscopy for structural biology
Thompson, R. F., Walker, M., Siebert, C. A., Muench, S. P., & Ranson, N. A. (2016) · Methods · doi:10.1016/j.ymeth.2016.02.017 · Cited by 282
Quantitative analysis of the native presynaptic cytomatrix by cryoelectron tomography
Fernández-Busnadiego, R., Zuber, B., Maurer, U. E., Cyrklaff, M., Baumeister, W., & Lučić, V. (2010) · Journal of Cell Biology · doi:10.1083/jcb.200908082 · Cited by 267
Self-citationHrabe, T., Chen, Y., Pfeffer, S., Kuhn Cuellar, L., Mangold, A.-V., & Förster, F. (2012) · Journal of Structural Biology · doi:10.1016/j.jsb.2011.12.003 · Cited by 260
Self-citationFast tomographic reconstruction on multicore computers
Agulleiro, J. I., & Fernandez, J. J. (2011) · Bioinformatics · doi:10.1093/bioinformatics/btq692 · Cited by 260
The native 3D organization of bacterial polysomes
Brandt, F., Etchells, S. A., Ortiz, J. O., Elcock, A. H., Hartl, F. U., & Baumeister, W. (2009) · Cell · doi:10.1016/j.cell.2008.11.016 · Cited by 258
“CET is a powerful method to reconstruct the 3D electron densities of individual macromolecular objects in a close-to-native environment without the need to stain or fix the specimen (Lucic et al., 2005).”
Electron Tomography for Heterogeneous Catalysts and Related Nanostructured Materials
Friedrich, H., de Jongh, P. E., Verkleij, A. J., & de Jong, K. P. (2009) · Chemical Reviews · doi:10.1021/cr800434t · Cited by 256
Cubic membranes: a legend beyond the Flatland* of cell membrane organization
Almsherqi, Z. A., Kohlwein, S. D., & Deng, Y. (2006) · The Journal of Cell Biology · doi:10.1083/jcb.200603055 · Cited by 238
“In recent years, tremendous progress has been made based on electron tomography (ET) that allows 3D reconstruction of sections that are up to 400 nm thick, with a resolution of 5 nm, i.e., approaching the molecular level (for review see Lucic et al., 2005).”
InfluentialCarlson, L.-A., Briggs, J. A. G., Glass, B., Riches, J. D., Simon, M. N., Johnson, M. C., Müller, B., Grünewald, K., & Kräusslich, H.-G. (2008) · Cell Host & Microbe · doi:10.1016/j.chom.2008.10.013 · Cited by 230
A visual approach to proteomics
Nickell, S., Kofler, C., Leis, A. P., & Baumeister, W. (2006) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm1861 · Cited by 228
Self-citationComplex Dynamic Development of Poliovirus Membranous Replication Complexes
Belov, G. A., Nair, V., Hansen, B. T., Hoyt, F. H., Fischer, E. R., & Ehrenfeld, E. (2012) · Journal of Virology · doi:10.1128/jvi.05937-11 · Cited by 222
“To reveal their spatial organization, 200-nm-thick sections of cells fixed at different times after infection were examined by electron tomography (4, 37).”
MethodSite-specific cryo-focused ion beam sample preparation guided by 3D correlative microscopy
Arnold, J., Mahamid, J., Lucic, V., de Marco, A., Fernandez, J.-J., Laugks, T., Mayer, T., Hyman, A. A., Baumeister, W., & Plitzko, J. M. (2016) · Biophysical Journal · doi:10.1016/j.bpj.2015.10.053 · Cited by 221
Self-citationVisualizing cells at the nanoscale
Leis, A., Rockel, B., Andrees, L., & Baumeister, W. (2009) · Trends in Biochemical Sciences · doi:10.1016/j.tibs.2008.10.011 · Cited by 220
Self-citationChowdhury, D. (2013) · Physics Reports · doi:10.1016/j.physrep.2013.03.005 · Cited by 212
“Modern electron microscopy has already provided deep insight into the structure and function of many molecular machines [2179, 2180, 2181, 2182, 2183, 2184, 2185].”
BackgroundThree-dimensional architecture of murine rod outer segments determined by cryoelectron tomography
Nickell, S., Park, P. S.-H., Baumeister, W., & Palczewski, K. (2007) · The Journal of Cell Biology · doi:10.1083/jcb.200612010 · Cited by 209
“The missing information in Fourier space as the result of a limited tilt range of specimens (i.e., missing wedge; Lucic et al., 2005) was not taken into account in the calculation of the mass of spacers.”
Self-citationIntegrating diverse data for structure determination of macromolecular assemblies
Alber, F., Förster, F., Korkin, D., Topf, M., & Sali, A. (2008) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.77.060407.135530 · Cited by 206
Self-citationElectron cryotomography sample preparation using the Vitrobot
Iancu, C. V., Tivol, W. F., Schooler, J. B., Dias, D. P., Henderson, G. P., Murphy, G. E., Wright, E. R., Li, Z., Yu, Z., Briegel, A., et al. (2006) · Nature Protocols · doi:10.1038/nprot.2006.432 · Cited by 202
“Electron cryotomography (ECT) is an increasingly important technique for determining the structure of unique objects such as flexible large protein complexes, irregular viruses, organelles or small cells (Lucic et al., 2005; Nickell et al., 2006).”
BackgroundElectron Tomography of the Contact between T Cells and SIV/HIV-1: Implications for Viral Entry
Sougrat, R., Bartesaghi, A., Lifson, J. D., Bennett, A. E., Bess, J. W., Zabransky, D. J., & Subramaniam, S. (2007) · PLoS Pathogens · doi:10.1371/journal.ppat.0030063 · Cited by 193
“Electron tomography is a powerful approach for determining the three-dimensional (3-D) structures of large and heterogeneous sub-cellular assemblies at resolutions that are typically one to two orders of magnitude higher than those that can be currently achieved using light microscopy [”
Zeuschner, D., Geerts, W. J. C., van Donselaar, E., Humbel, B. M., Slot, J. W., Koster, A. J., & Klumperman, J. (2006) · Nature Cell Biology · doi:10.1038/ncb1371 · Cited by 192
“It has been argued repeatedly that rapid freezing procedures are superior to chemical fixation methods for avoiding artefacts such as vesiculation of membrane”
Structural Basis of Vesicle Formation at the Inner Nuclear Membrane
Hagen, C., Dent, K. C., Zeev-Ben-Mordehai, T., Grange, M., Bosse, J. B., Whittle, C., Klupp, B. G., Siebert, C. A., Vasishtan, D., Bäuerlein, F. J. B., et al. (2015) · Cell · doi:10.1016/j.cell.2015.11.029 · Cited by 188
“CryoET imaging of areas deeper inside cells typically requires vitreous sections in order to provide electron transparent specimens of 500 nm thickness (Luci c et al., 2005).”
CTF determination and correction in electron cryotomography
Fernández, J. J., Li, S., & Crowther, R. A. (2006) · Ultramicroscopy · doi:10.1016/j.ultramic.2006.02.004 · Cited by 188
Structure and gating of the nuclear pore complex
Eibauer, M., Pellanda, M., Turgay, Y., Dubrovsky, A., Wild, A., & Medalia, O. (2015) · Nature Communications · doi:10.1038/ncomms8532 · Cited by 187
An Introduction to Sparse Stochastic Processes
Unser, M., & Tafti, P. D. (2014) · Cambridge University Press eBooks · doi:10.1017/cbo9781107415805 · Cited by 184
Fully automated, sequential tilt-series acquisition with Leginon
Suloway, C., Shi, J., Cheng, A., Pulokas, J., Carragher, B., Potter, C. S., Zheng, S. Q., Agard, D. A., & Jensen, G. J. (2009) · Journal of Structural Biology · doi:10.1016/j.jsb.2009.03.019 · Cited by 181
“Electron tomography (ET) is the highest resolution technique available today for observing the 3D structure of unique biological objects such as cells, many viruses, and certain flexible macromolecules, and is also being used increasingly in various ‘‘Materials science” applications (Jensen and Briegel, 2007; Lučić et…”
BackgroundMoving into the cell: single-molecule studies of molecular motors in complex environments
Veigel, C., & Schmidt, C. F. (2011) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm3062 · Cited by 176
“Imaging of single actin filaments and microtubules in situ in cells is now within reach with high-resolution electron tomograph”
BackgroundCorrelative Super-Resolution Microscopy: New Dimensions and New Opportunities
Hauser, M., Wojcik, M., Kim, D., Mahmoudi, M., Li, W., & Xu, K. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00604 · Cited by 176
Classification of cryo-electron sub-tomograms using constrained correlation
Förster, F., Pruggnaller, S., Seybert, A., & Frangakis, A. S. (2008) · Journal of Structural Biology · doi:10.1016/j.jsb.2007.07.006 · Cited by 174
Self-citationNative 3D intermediates of membrane fusion in herpes simplex virus 1 entry
Maurer, U. E., Sodeik, B., & Grünewald, K. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0801674105 · Cited by 173
“Cellular cryo-ET (12), however, is limited to specimen areas with a maximal thickness of 1 m (13), and therefore we could only analyze the outer rims of Vero cells.”
Coherent X-Ray Diffraction Imaging
Miao, J., Sandberg, R. L., & Song, C. (2012) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2011.2157306 · Cited by 172
High-Pressure Freezing, Cellular Tomography, and Structural Cell Biology
McDonald, K. L., & Auer, M. (2006) · BioTechniques · doi:10.2144/000112226 · Cited by 172
Hard X-ray fluorescence tomography—an emerging tool for structural visualization
de Jonge, M. D., & Vogt, S. (2010) · Current Opinion in Structural Biology · doi:10.1016/j.sbi.2010.09.002 · Cited by 172
“Several excellent recent reviews introduce the main concepts for tomography and nano-tomography [14–16].”
BackgroundLiu, J., Lin, T., Botkin, D. J., McCrum, E., Winkler, H., & Norris, S. J. (2009) · Journal of Bacteriology · doi:10.1128/jb.00340-09 · Cited by 168
“Cryo-ET has emerged as a three-dimensional (3-D) imaging technique to bridge the information gap between X-ray crystallographic and optical microscopic methods (24, 30).”
MethodDevelopments, applications, and prospects of cryo‐electron microscopy
Benjin, X., & Ling, L. (2020) · Protein Science · doi:10.1002/pro.3805 · Cited by 166
“In recent years, much new knowledge has been gained in the field of cell biology by means of cryo-ET, including the ultrastructure of mitochondria, ribosomes, the endoplasmic reticulum and the Golgi complex, the structure of spindles involved in cell division, the tissue structure of insect flying muscles, the 3D stru…”
BackgroundGan, L., & Jensen, G. J. (2012) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583511000102 · Cited by 165
“In this review, we will summarize the current methods and technologies to prepare a specimen, collect data, generate a tomogram, and finally interpret and analyze the result (for additional technical details, see also Frank, 2006 ; Koster et al. 1997 ; Lucic et al. 2005).”
MethodThe Three-Dimensional Organization of Polyribosomes in Intact Human Cells
Brandt, F., Carlson, L.-A., Hartl, F. U., Baumeister, W., & Grünewald, K. (2010) · Molecular Cell · doi:10.1016/j.molcel.2010.08.003 · Cited by 165
Self-citationDirect visualization of dispersed lipid bicontinuous cubic phases by cryo-electron tomography
Demurtas, D., Guichard, P., Martiel, I., Mezzenga, R., Hébert, C., & Sagalowicz, L. (2015) · Nature Communications · doi:10.1038/ncomms9915 · Cited by 162
Visual proteomics of the human pathogen Leptospira interrogans
Beck, M., Malmström, J. A., Lange, V., Schmidt, A., Deutsch, E. W., & Aebersold, R. (2009) · Nature Methods · doi:10.1038/nmeth.1390 · Cited by 156
Human T-Lymphotropic Virus-1 Visualized at the Virological Synapse by Electron Tomography
Majorovits, E., Nejmeddine, M., Tanaka, Y., Taylor, G. P., Fuller, S. D., & Bangham, C. R. M. (2008) · PLoS ONE · doi:10.1371/journal.pone.0002251 · Cited by 110
“tomography permits the reconstruction of a 3D image [17] from”
BackgroundSchur, F. K. M., Hagen, W. J. H., de Marco, A., & Briggs, J. A. G. (2013) · Journal of Structural Biology · doi:10.1016/j.jsb.2013.10.015 · Cited by 90
SuRVoS: Super-Region Volume Segmentation workbench
Luengo, I., Darrow, M. C., Spink, M. C., Sun, Y., Dai, W., He, C. Y., Chiu, W., Pridmore, T., Ashton, A. W., Duke, E. M. H., et al. (2017) · Journal of Structural Biology · doi:10.1016/j.jsb.2017.02.007 · Cited by 89
Vimentin filaments integrate low-complexity domains in a complex helical structure
Eibauer, M., Weber, M. S., Kronenberg-Tenga, R., Beales, C. T., Boujemaa-Paterski, R., Turgay, Y., Sivagurunathan, S., Kraxner, J., Köster, S., Goldman, R. D., et al. (2024) · Nature Structural & Molecular Biology · doi:10.1038/s41594-024-01261-2 · Cited by 87
Electron tomographic analysis of synaptic ultrastructure
Burette, A. C., Lesperance, T., Crum, J., Martone, M., Volkmann, N., Ellisman, M. H., & Weinberg, R. J. (2012) · Journal of Comparative Neurology · doi:10.1002/cne.23067 · Cited by 85
Xu, W., Xu, F., Jones, M., Keszthelyi, B., Sedat, J., Agard, D., & Mueller, K. (2010) · Journal of Structural Biology · doi:10.1016/j.jsb.2010.03.018 · Cited by 71
“Electron Tomography (ET) (see for example Frank, 2006, or Lucic et al., 2005) uniquely enables the 3D study of complex cellular structures, such as the cytoskeleton, organelles, viruses and chromosomes.”
BackgroundMethodGui, L., Song, K., Tritschler, D., Bower, R., Yan, S., Dai, A., Augspurger, K., Sakizadeh, J., Grzemska, M., Ni, T., et al. (2019) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1910960116 · Cited by 60
A matrix approach to tomographic reconstruction and its implementation on GPUs
Vázquez, F., Garzón, E. M., & Fernández, J. J. (2010) · Journal of Structural Biology · doi:10.1016/j.jsb.2010.01.021 · Cited by 39
“Electron tomography (ET) is an essential structural technique in cellular biology (Lucic et al., 2005).”
Background
Metadata
- Authors
- Lučić, V., Förster, F., & Baumeister, W.
- Venue
- Annual Review of Biochemistry
- Publisher
- Annual Reviews
- Published
- 2005-06-01
- Volume
- 74
- Issue
- 1
- Pages
- 833-865
- ISSN
- 0066-4154 (ISSN-L)
- 1545-4509
- OpenAlex
- W2123176293
- Cited by
- 702
- References
- 85
- FWCI
- 3.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.