Blood-on-a-Chip
Open accessThe DOI matches its Crossref record; 77 of the 77 references it cites were found in a registry or an index.
Abstract
▪ Abstract Accurate, fast, and affordable analysis of the cellular component of blood is of prime interest for medicine and research. Yet, most often sample preparation procedures for blood analysis involve handling steps prone to introducing artifacts, whereas analysis methods commonly require skilled technicians and well-equipped, expensive laboratories. Developing more gentle protocols and affordable instruments for specific blood analysis tasks is becoming possible through the recent progress in the area of microfluidics and lab-on-a-chip-type devices. Precise control over the cell microenvironment during separation procedures and the ability to scale down the analysis to very small volumes of blood are among the most attractive capabilities of the new approaches. Here we review some of the emerging principles for manipulating blood cells at microscale and promising high-throughput approaches to blood cell separation using microdevices. Examples of specific single-purpose devices are described together with integration strategies for blood cell separation and analysis modules.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Goycoolea, A. (1997) · Cited by 3,615
Emmert-Buck, M. R., Bonner, R. F., Smith, P. D., Chuaqui, R. F., Zhuang, Z., Goldstein, S. R., Weiss, R. A., & Liotta, L. A. (1996) · Science · doi:10.1126/science.274.5289.998 · Cited by 2,534
Continuous Particle Separation Through Deterministic Lateral Displacement
Huang, L. R., Cox, E. C., Austin, R. H., & Sturm, J. C. (2004) · Science · doi:10.1126/science.1094567 · Cited by 1,634
An Integrated Nanoliter DNA Analysis Device
Burns, M. A., Johnson, B. N., Brahmasandra, S. N., Handique, K., Webster, J. R., Krishnan, M., Sammarco, T. S., Man, P. M., Jones, D., Heldsinger, D., et al. (1998) · Science · doi:10.1126/science.282.5388.484 · Cited by 1,299
Microfluidic sorting in an optical lattice
MacDonald, M. P., Spalding, G. C., & Dholakia, K. (2003) · Nature · doi:10.1038/nature02144 · Cited by 1,246
Wintrobe's clinical hematology.
Lee, G. R. (1981) · Medical Entomology and Zoology · Cited by 1,167
Wintrobe’s Clinical Hematology
Mehta, P. (2009) · JAMA · doi:10.1001/jama.2009.1818 · Cited by 1,160
Micro Total Analysis Systems. Recent Developments
Vilkner, T., Janasek, D., & Manz, A. (2004) · Analytical Chemistry · doi:10.1021/ac040063q · Cited by 968
A microfabricated fluorescence-activated cell sorter
Fu, A. Y., Spence, C., Scherer, A., Arnold, F. H., & Quake, S. R. (1999) · Nature Biotechnology · doi:10.1038/15095 · Cited by 878
Particle separation by dielectrophoresis
Gascoyne, P. R. C., & Vykoukal, J. (2002) · ELECTROPHORESIS · doi:10.1002/1522-2683(200207)23:13<1973::aid-elps1973>3.0.co;2-1 · Cited by 826
Cited by
Isolation of rare circulating tumour cells in cancer patients by microchip technology
Nagrath, S., Sequist, L. V., Maheswaran, S., Bell, D. W., Irimia, D., Ulkus, L., Smith, M. R., Kwak, E. L., Digumarthy, S., Muzikansky, A., et al. (2007) · Nature · doi:10.1038/nature06385 · Cited by 3,559
Self-citationMicrofluidic diagnostic technologies for global public health
Yager, P., Edwards, T., Fu, E., Helton, K., Nelson, K., Tam, M. R., & Weigl, B. H. (2006) · Nature · doi:10.1038/nature05064 · Cited by 1,979
Continuous inertial focusing, ordering, and separation of particles in microchannels
Di Carlo, D., Irimia, D., Tompkins, R. G., & Toner, M. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0704958104 · Cited by 1,708
Self-citationPoint of Care Diagnostics: Status and Future
Gubala, V., Harris, L. F., Ricco, A. J., Tan, M. X., & Williams, D. E. (2012) · Analytical Chemistry · doi:10.1021/ac2030199 · Cited by 1,194
Point-of-Care Diagnostics for Global Health
Yager, P., Domingo, G. J., & Gerdes, J. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160524 · Cited by 1,076
Wyatt Shields IV, C., Reyes, C. D., & López, G. P. (2015) · Lab on a Chip · doi:10.1039/c4lc01246a · Cited by 1,036
Label-free cell separation and sorting in microfluidic systems
Gossett, D. R., Weaver, W. M., Mach, A. J., Hur, S. C., Tse, H. T. K., Lee, W., Amini, H., & Di Carlo, D. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3721-9 · Cited by 930
Polymer microfabrication technologies for microfluidic systems
Becker, H., & Gärtner, C. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1692-2 · Cited by 860
Aqueous two-phase system (ATPS): an overview and advances in its applications
Iqbal, M., Tao, Y., Xie, S., Zhu, Y., Chen, D., Wang, X., Huang, L., Peng, D., Sattar, A., Shabbir, M. A. B., et al. (2016) · Biological Procedures Online · doi:10.1186/s12575-016-0048-8 · Cited by 821
Particle separation and sorting in microfluidic devices: a review
Sajeesh, P., & Sen, A. K. (2014) · Microfluidics and Nanofluidics · doi:10.1007/s10404-013-1291-9 · Cited by 767
Inertial microfluidics for continuous particle separation in spiral microchannels
Kuntaegowdanahalli, S. S., Bhagat, A. A. S., Kumar, G., & Papautsky, I. (2009) · Lab on a Chip · doi:10.1039/b908271a · Cited by 708
Microfluidic Applications of Magnetic Particles for Biological Analysis and Catalysis
Gijs, M. A. M., Lacharme, F., & Lehmann, U. (2010) · Chemical Reviews · doi:10.1021/cr9001929 · Cited by 679
Continuous particle separation in spiral microchannels using dean flows and differential migration
Bhagat, A. A. S., Kuntaegowdanahalli, S. S., & Papautsky, I. (2008) · Lab on a Chip · doi:10.1039/b807107a · Cited by 656
Inertial Focusing in Microfluidics
Martel, J. M., & Toner, M. (2014) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-121813-120704 · Cited by 571
Self-citationFan, R., Vermesh, O., Srivastava, A., Yen, B. K. H., Qin, L., Ahmad, H., Kwong, G. A., Liu, C.-C., Gould, J., Hood, L., et al. (2008) · Nature Biotechnology · doi:10.1038/nbt.1507 · Cited by 539
Microfluidic Chips for Point‐of‐Care Immunodiagnostics
Gervais, L., de Rooij, N., & Delamarche, E. (2011) · Advanced Materials · doi:10.1002/adma.201100464 · Cited by 491
Microfluidics technology for manipulation and analysis of biological cells
Yi, C., Li, C.-W., Ji, S., & Yang, M. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.12.037 · Cited by 478
Equilibrium Separation and Filtration of Particles Using Differential Inertial Focusing
Di Carlo, D., Edd, J. F., Irimia, D., Tompkins, R. G., & Toner, M. (2008) · Analytical Chemistry · doi:10.1021/ac702283m · Cited by 413
Self-citationAdvances in Plasmonic Technologies for Point of Care Applications
Tokel, O., Inci, F., & Demirci, U. (2014) · Chemical Reviews · doi:10.1021/cr4000623 · Cited by 407
Analysis of single mammalian cells on-chip
Sims, C. E., & Allbritton, N. L. (2007) · Lab on a Chip · doi:10.1039/b615235j · Cited by 400
Microfluidic immunoassays as rapid saliva-based clinical diagnostics
Herr, A. E., Hatch, A. V., Throckmorton, D. J., Tran, H. M., Brennan, J. S., Giannobile, W. V., & Singh, A. K. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0607254104 · Cited by 389
Mobile phones democratize and cultivate next-generation imaging, diagnostics and measurement tools
Ozcan, A. (2014) · Lab Chip · doi:10.1039/c4lc00010b · Cited by 364
Nano/Microfluidics for diagnosis of infectious diseases in developing countries
Lee, W. G., Kim, Y.-G., Chung, B. G., Demirci, U., & Khademhosseini, A. (2010) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2009.11.016 · Cited by 357
Heath, J. R., & Davis, M. E. (2008) · Annual Review of Medicine · doi:10.1146/annurev.med.59.061506.185523 · Cited by 354
Bhagat, A. A. S., Hou, H. W., Li, L. D., Lim, C. T., & Han, J. (2011) · Lab on a Chip · doi:10.1039/c0lc00633e · Cited by 350
Microfluidic high-throughput encapsulation and hydrodynamic self-sorting of single cells
Chabert, M., & Viovy, J.-L. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0708321105 · Cited by 344
A microfluidic device for practical label-free CD4+ T cell counting of HIV-infected subjects
Cheng, X., Irimia, D., Dixon, M., Sekine, K., Demirci, U., Zamir, L., Tompkins, R. G., Rodriguez, W., & Toner, M. (2007) · Lab Chip · doi:10.1039/b612966h · Cited by 340
Self-citationMicrofluidic sorting and multimodal typing of cancer cells in self-assembled magnetic arrays
Saliba, A.-E., Saias, L., Psychari, E., Minc, N., Simon, D., Bidard, F.-C., Mathiot, C., Pierga, J.-Y., Fraisier, V., Salamero, J., et al. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1001515107 · Cited by 337
Fundamentals and application of magnetic particles in cell isolation and enrichment: a review
Plouffe, B. D., Murthy, S. K., & Lewis, L. H. (2015) · Reports on Progress in Physics · doi:10.1088/0034-4885/78/1/016601 · Cited by 334
“Toner and Irimia (2005) presented a thorough review of blood-on-a-chip technology which describes the challenges of handling blood and the information that can be gleaned from the various components of blood.”
BackgroundInertial microfluidics for continuous particle filtration and extraction
Bhagat, A. A. S., Kuntaegowdanahalli, S. S., & Papautsky, I. (2009) · Microfluidics and Nanofluidics · doi:10.1007/s10404-008-0377-2 · Cited by 334
Continuous scalable blood filtration device using inertial microfluidics
Mach, A. J., & Di Carlo, D. (2010) · Biotechnology and Bioengineering · doi:10.1002/bit.22833 · Cited by 334
Numerical Simulation of Flowing Blood Cells
Freund, J. B. (2014) · Annual Review of Fluid Mechanics · doi:10.1146/annurev-fluid-010313-141349 · Cited by 323
Gravity-Driven Microfluidic Particle Sorting Device with Hydrodynamic Separation Amplification
Huh, D., Bahng, J. H., Ling, Y., Wei, H.-H., Kripfgans, O. D., Fowlkes, J. B., Grotberg, J. B., & Takayama, S. (2007) · Analytical Chemistry · doi:10.1021/ac061542n · Cited by 315
One-step pathogen specific DNA extraction from whole blood on a centrifugal microfluidic device
Cho, Y.-K., Lee, J.-G., Park, J.-M., Lee, B.-S., Lee, Y., & Ko, C. (2007) · Lab on a Chip · doi:10.1039/b616115d · Cited by 312
Flow-induced clustering and alignment of vesicles and red blood cells in microcapillaries
McWhirter, J. L., Noguchi, H., & Gompper, G. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0811484106 · Cited by 300
Advances in microfluidic PCR for point-of-care infectious disease diagnostics
Park, S., Zhang, Y., Lin, S., Wang, T.-H., & Yang, S. (2011) · Biotechnology Advances · doi:10.1016/j.biotechadv.2011.06.017 · Cited by 299
Automated cellular sample preparation using a Centrifuge-on-a-Chip
Mach, A. J., Kim, J. H., Arshi, A., Hur, S. C., & Di Carlo, D. (2011) · Lab on a Chip · doi:10.1039/c1lc20330d · Cited by 280
DC-Dielectrophoretic separation of biological cells by size
Kang, Y., Li, D., Kalams, S. A., & Eid, J. E. (2008) · Biomedical Microdevices · doi:10.1007/s10544-007-9130-y · Cited by 276
Towards non- and minimally instrumented, microfluidics-based diagnostic devices
Weigl, B., Domingo, G., LaBarre, P., & Gerlach, J. (2008) · Lab on a Chip · doi:10.1039/b811314a · Cited by 259
Iso-acoustic focusing of cells for size-insensitive acousto-mechanical phenotyping
Augustsson, P., Karlsen, J. T., Su, H.-W., Bruus, H., & Voldman, J. (2016) · Nature Communications · doi:10.1038/ncomms11556 · Cited by 246
Continuous separation of blood cells in spiral microfluidic devices
Nivedita, N., & Papautsky, I. (2013) · Biomicrofluidics · doi:10.1063/1.4819275 · Cited by 245
Nasiri, R., Shamloo, A., Ahadian, S., Amirifar, L., Akbari, J., Goudie, M. J., Lee, K., Ashammakhi, N., Dokmeci, M. R., Di Carlo, D., et al. (2020) · Small · doi:10.1002/smll.202000171 · Cited by 244
Quartz crystal microbalance-based biosensors as rapid diagnostic devices for infectious diseases
Lim, H. J., Saha, T., Tey, B. T., Tan, W. S., & Ooi, C. W. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112513 · Cited by 236
Passive blood plasma separation at the microscale: a review of design principles and microdevices
Tripathi, S., Varun Kumar, Y. V. B., Prabhakar, A., Joshi, S. S., & Agrawal, A. (2015) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/25/8/083001 · Cited by 223
Micro-scale blood plasma separation: from acoustophoresis to egg-beaters
Kersaudy-Kerhoas, M., & Sollier, E. (2013) · Lab on a Chip · doi:10.1039/c3lc50432h · Cited by 220
Rapid isolation of cancer cells using microfluidic deterministic lateral displacement structure
Liu, Z., Huang, F., Du, J., Shu, W., Feng, H., Xu, X., & Chen, Y. (2013) · Biomicrofluidics · doi:10.1063/1.4774308 · Cited by 220
Microfluidics for Manipulating Cells
Mu, X., Zheng, W., Sun, J., Zhang, W., & Jiang, X. (2013) · Small · doi:10.1002/smll.201200996 · Cited by 214
Electrokinetic motion of particles and cells in microchannels
Kang, Y., & Li, D. (2009) · Microfluidics and Nanofluidics · doi:10.1007/s10404-009-0408-7 · Cited by 210
Design, fabrication and characterization of drug delivery systems based on lab-on-a-chip technology
Nguyen, N.-T., Shaegh, S. A. M., Kashaninejad, N., & Phan, D.-T. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.05.008 · Cited by 210
“In vitro (pharmaco-kinetics) 1) Brain-on-a-chip [58, 59] 2) Heart-on-a-chip [60] 3) Liver-on-a-chip [13, 61-64] 4) Lung-on-a-chip [3, 65, 66] 5) Kidney-on-a-chip [67, 68] 6) Spleen-on-a-chip [51] 7) Intestine-on-a-chip [51, 69] 8) Gut-on-a-chip [70, 71] 9) Cornea-on-a-chip [60] 10) Blood vessel-on-a-chip [72-79] 11) M…”
Dynamic self-assembly and control of microfluidic particle crystals
Lee, W., Amini, H., Stone, H. A., & Di Carlo, D. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1010297107 · Cited by 209
D'Avino, G., Romeo, G., Villone, M. M., Greco, F., Netti, P. A., & Maffettone, P. L. (2012) · Lab on a Chip · doi:10.1039/c2lc21154h · Cited by 205
Bio‐microfluidics: Biomaterials and Biomimetic Designs
Domachuk, P., Tsioris, K., Omenetto, F. G., & Kaplan, D. L. (2010) · Advanced Materials · doi:10.1002/adma.200900821 · Cited by 205
Lima, R., Wada, S., Tanaka, S., Takeda, M., Ishikawa, T., Tsubota, K.-I., Imai, Y., & Yamaguchi, T. (2008) · Biomedical Microdevices · doi:10.1007/s10544-007-9121-z · Cited by 201
“…(so-called bio-micro-electromechanical systems or a lab-on-a-chip; Sutton et al. 1997; Gomez et al. 2001; Beebe et al. 2002; Gifford et al. 2003; Minas et al. 2004; Toner and Irimia 2005; Faivre et al. 2006) capable of providing useful information about the general health status of patients.”
BackgroundLee, B. S., Lee, Y. U., Kim, H.-S., Kim, T.-H., Park, J., Lee, J.-G., Kim, J., Kim, H., Lee, W. G., & Cho, Y.-K. (2011) · Lab Chip · doi:10.1039/c0lc00205d · Cited by 200
Biomanufacturing for clinically advanced cell therapies
Aijaz, A., Li, M., Smith, D., Khong, D., LeBlon, C., Fenton, O. S., Olabisi, R. M., Libutti, S., Tischfield, J., Maus, M. V., et al. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0246-6 · Cited by 191
The intersection of flow cytometry with microfluidics and microfabrication
Piyasena, M. E., & Graves, S. W. (2014) · Lab Chip · doi:10.1039/c3lc51152a · Cited by 189
Continuous separation of microparticles by size with Direct current‐dielectrophoresis
Kang, K. H., Kang, Y., Xuan, X., & Li, D. (2006) · ELECTROPHORESIS · doi:10.1002/elps.200500558 · Cited by 188
Joule heating in electrokinetic flow
Xuan, X. (2008) · ELECTROPHORESIS · doi:10.1002/elps.200700302 · Cited by 182
A Review of Biomedical Centrifugal Microfluidic Platforms
Tang, M., Wang, G., Kong, S.-K., & Ho, H.-P. (2016) · Micromachines · doi:10.3390/mi7020026 · Cited by 181
Engineering fluid flow using sequenced microstructures
Amini, H., Sollier, E., Masaeli, M., Xie, Y., Ganapathysubramanian, B., Stone, H. A., & Di Carlo, D. (2013) · Nature Communications · doi:10.1038/ncomms2841 · Cited by 173
Microfluidic technologies for circulating tumor cell isolation
Cho, H., Kim, J., Song, H., Sohn, K. Y., Jeon, M., & Han, K.-H. (2018) · The Analyst · doi:10.1039/c7an01979c · Cited by 167
Microfluidic Devices for Blood Fractionation
Hou, H. W., Bhagat, A. A. S., Lee, W. C., Huang, S., Han, J., & Lim, C. T. (2011) · Micromachines · doi:10.3390/mi2030319 · Cited by 167
Cell research with physically modified microfluidic channels: A review
Kim, S. M., Lee, S. H., & Suh, K. Y. (2008) · Lab on a Chip · doi:10.1039/b800835c · Cited by 166
Xu, L., Lee, H., Jetta, D., & Oh, K. W. (2015) · Lab on a Chip · doi:10.1039/c5lc00716j · Cited by 164
Microfluidic: An innovative tool for efficient cell sorting
Autebert, J., Coudert, B., Bidard, F.-C., Pierga, J.-Y., Descroix, S., Malaquin, L., & Viovy, J.-L. (2012) · Methods · doi:10.1016/j.ymeth.2012.07.002 · Cited by 163
“Objectives of blood cells subpopulation capture and existing solutions have been described by Toner and Irimia[1].”
MethodInertial Manipulation and Transfer of Microparticles Across Laminar Fluid Streams
Gossett, D. R., Tse, H. T. K., Dudani, J. S., Goda, K., Woods, T. A., Graves, S. W., & Di Carlo, D. (2012) · Small · doi:10.1002/smll.201200588 · Cited by 163
Polymer-Based Microfluidic Devices for Pharmacy, Biology and Tissue Engineering
Alrifaiy, A., Lindahl, O. A., & Ramser, K. (2012) · Polymers · doi:10.3390/polym4031349 · Cited by 161
Chen, J., Xue, C., Zhao, Y., Chen, D., Wu, M.-H., & Wang, J. (2015) · International Journal of Molecular Sciences · doi:10.3390/ijms16059804 · Cited by 160
Microfluidic Blood Cell Sorting: Now and Beyond
Yu, Z. T. F., Aw Yong, K. M., & Fu, J. (2014) · Small · doi:10.1002/smll.201302907 · Cited by 159
Nanotechnology: emerging tools for biology and medicine
Wong, I. Y., Bhatia, S. N., & Toner, M. (2013) · Genes & Development · doi:10.1101/gad.226837.113 · Cited by 132
Self-citation
Metadata
- Authors
- Toner, M., & Irimia, D.
- Venue
- Annual Review of Biomedical Engineering
- Publisher
- Annual Reviews
- Published
- 2005-08-15
- Volume
- 7
- Issue
- 1
- Pages
- 77-103
- ISSN
- 1523-9829 (ISSN-L)
- 1545-4274
- OpenAlex
- W2160738932
- Cited by
- 623
- References
- 77
- FWCI
- 2.98
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.