Superresolution Imaging using Single-Molecule Localization
Open accessThe DOI matches its Crossref record; 84 of the 84 references it cites were found in a registry or an index.
Abstract
Superresolution imaging is a rapidly emerging new field of microscopy that dramatically improves the spatial resolution of light microscopy by over an order of magnitude (∼10–20-nm resolution), allowing biological processes to be described at the molecular scale. Here, we discuss a form of superresolution microscopy based on the controlled activation and sampling of sparse subsets of photoconvertible fluorescent molecules. In this single-molecule-based imaging approach, a wide variety of probes have proved valuable, ranging from genetically encodable photoactivatable fluorescent proteins to photoswitchable cyanine dyes. These have been used in diverse applications of superresolution imaging: from three-dimensional, multicolor molecule localization to tracking of nanometric structures and molecules in living cells. Single-molecule-based superresolution imaging thus offers exciting possibilities for obtaining molecular-scale information on biological events occurring at variable timescales.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Imaging Intracellular Fluorescent Proteins at Nanometer Resolution
Betzig, E., Patterson, G. H., Sougrat, R., Lindwasser, O. W., Olenych, S., Bonifacino, J. S., Davidson, M. W., Lippincott-Schwartz, J., & Hess, H. F. (2006) · Science · doi:10.1126/science.1127344 · Cited by 8,772
Self-citationSub-diffraction-limit imaging by stochastic optical reconstruction microscopy (STORM)
Rust, M. J., Bates, M., & Zhuang, X. (2006) · Nature Methods · doi:10.1038/nmeth929 · Cited by 8,078
Quantum Dots for Live Cells, in Vivo Imaging, and Diagnostics
Michalet, X., Pinaud, F. F., Bentolila, L. A., Tsay, J. M., Doose, S., Li, J. J., Sundaresan, G., Wu, A. M., Gambhir, S. S., & Weiss, S. (2005) · Science · doi:10.1126/science.1104274 · Cited by 7,790
Tsien, R. Y. (1998) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.67.1.509 · Cited by 6,143
Hell, S. W., & Wichmann, J. (1994) · Optics Letters · doi:10.1364/ol.19.000780 · Cited by 6,065
Ultra-High Resolution Imaging by Fluorescence Photoactivation Localization Microscopy
Hess, S. T., Girirajan, T. P. K., & Mason, M. D. (2006) · Biophysical Journal · doi:10.1529/biophysj.106.091116 · Cited by 3,605
Three-Dimensional Super-Resolution Imaging by Stochastic Optical Reconstruction Microscopy
Huang, B., Wang, W., Bates, M., & Zhuang, X. (2008) · Science · doi:10.1126/science.1153529 · Cited by 2,796
Precise Nanometer Localization Analysis for Individual Fluorescent Probes
Thompson, R. E., Larson, D. R., & Webb, W. W. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75618-x · Cited by 2,320 · cited 1×
“This precision scales with the inverse square of the number of detected photons (20) (Figure 1a).”
Gustafsson, M. G. L. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0406877102 · Cited by 2,224
Subdiffraction‐Resolution Fluorescence Imaging with Conventional Fluorescent Probes
Heilemann, M., van de Linde, S., Schüttpelz, M., Kasper, R., Seefeldt, B., Mukherjee, A., Tinnefeld, P., & Sauer, M. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200802376 · Cited by 1,866
Cited by
Evaluation of fluorophores for optimal performance in localization-based super-resolution imaging
Dempsey, G. T., Vaughan, J. C., Chen, K. H., Bates, M., & Zhuang, X. (2011) · Nature Methods · doi:10.1038/nmeth.1768 · Cited by 1,369
Breaking the Diffraction Barrier: Super-Resolution Imaging of Cells
Huang, B., Babcock, H., & Zhuang, X. (2010) · Cell · doi:10.1016/j.cell.2010.12.002 · Cited by 1,156
Single-Molecule Surface-Enhanced Raman Spectroscopy
Le Ru, E. C., & Etchegoin, P. G. (2012) · Annual Review of Physical Chemistry · doi:10.1146/annurev-physchem-032511-143757 · Cited by 753
Advanced Fluorescence Microscopy Techniques—FRAP, FLIP, FLAP, FRET and FLIM
Ishikawa-Ankerhold, H. C., Ankerhold, R., & Drummen, G. P. C. (2012) · Molecules · doi:10.3390/molecules17044047 · Cited by 557
Shim, S.-H., Xia, C., Zhong, G., Babcock, H. P., Vaughan, J. C., Huang, B., Wang, X., Xu, C., Bi, G.-Q., & Zhuang, X. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1201882109 · Cited by 514
Imaging with total internal reflection fluorescence microscopy for the cell biologist
Mattheyses, A. L., Simon, S. M., & Rappoport, J. Z. (2010) · Journal of Cell Science · doi:10.1242/jcs.056218 · Cited by 385
BODIPY–Tetrazine Derivatives as Superbright Bioorthogonal Turn‐on Probes
Carlson, J. C. T., Meimetis, L. G., Hilderbrand, S. A., & Weissleder, R. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201301100 · Cited by 334
The 2015 super-resolution microscopy roadmap
Hell, S. W., Sahl, S. J., Bates, M., Zhuang, X., Heintzmann, R., Booth, M. J., Bewersdorf, J., Shtengel, G., Hess, H., Tinnefeld, P., et al. (2015) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/48/44/443001 · Cited by 325
Photophysical processes in single molecule organic fluorescent probes
Stennett, E. M. S., Ciuba, M. A., & Levitus, M. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60211g · Cited by 323
Switchable Fluorophores for Single-Molecule Localization Microscopy
Li, H., & Vaughan, J. C. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00767 · Cited by 319
A New Wave of Cellular Imaging
Toomre, D., & Bewersdorf, J. (2010) · Annual Review of Cell and Developmental Biology · doi:10.1146/annurev-cellbio-100109-104048 · Cited by 319
Simultaneous multiple-emitter fitting for single molecule super-resolution imaging
Huang, F., Schwartz, S. L., Byars, J. M., & Lidke, K. A. (2011) · Biomedical Optics Express · doi:10.1364/boe.2.001377 · Cited by 311
Lohse, M. J., Nuber, S., & Hoffmann, C. (2012) · Pharmacological Reviews · doi:10.1124/pr.110.004309 · Cited by 307
Differentiation between oppositely oriented microtubules controls polarized neuronal transport
Tas, R. P., Chazeau, A., Cloin, B. M. C., Lambers, M. L. A., Hoogenraad, C. C., & Kapitein, L. C. (2017) · Neuron · doi:10.1016/j.neuron.2017.11.018 · Cited by 306
Ultra-High Resolution 3D Imaging of Whole Cells
Huang, F., Sirinakis, G., Allgeyer, E. S., Schroeder, L. K., Duim, W. C., Kromann, E. B., Phan, T., Rivera-Molina, F. E., Myers, J. R., Irnov, I., et al. (2016) · Cell · doi:10.1016/j.cell.2016.06.016 · Cited by 303
Super-Resolution Imaging and Plasmonics
Willets, K. A., Wilson, A. J., Sundaresan, V., & Joshi, P. B. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00547 · Cited by 301
Facile preparation of water-soluble fluorescent gold nanoclusters for cellular imaging applications
Shang, L., Dörlich, R. M., Brandholt, S., Schneider, R., Trouillet, V., Bruns, M., Gerthsen, D., & Nienhaus, G. U. (2011) · Nanoscale · doi:10.1039/c0nr00947d · Cited by 299
STED Nanoscopy of Actin Dynamics in Synapses Deep Inside Living Brain Slices
Urban, N. T., Willig, K. I., Hell, S. W., & Nägerl, U. V. (2011) · Biophysical Journal · doi:10.1016/j.bpj.2011.07.027 · Cited by 297
Tracking Single Particles and Elongated Filaments with Nanometer Precision
Ruhnow, F., Zwicker, D., & Diez, S. (2011) · Biophysical Journal · doi:10.1016/j.bpj.2011.04.023 · Cited by 295
Highly Sensitive and Multiplexed Protein Measurements
Cohen, L., & Walt, D. R. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00257 · Cited by 294
Imaging proteins inside cells with fluorescent tags
Crivat, G., & Taraska, J. W. (2012) · Trends in Biotechnology · doi:10.1016/j.tibtech.2011.08.002 · Cited by 291
Fluorescent Nanoparticles for Super-Resolution Imaging
Li, W., Kaminski Schierle, G. S., Lei, B., Liu, Y., & Kaminski, C. F. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00050 · Cited by 278
Live-Cell Super-Resolution Imaging with Synthetic Fluorophores
van de Linde, S., Heilemann, M., & Sauer, M. (2012) · Annual Review of Physical Chemistry · doi:10.1146/annurev-physchem-032811-112012 · Cited by 266
Chung, J.-J., Shim, S.-H., Everley, R. A., Gygi, S. P., Zhuang, X., & Clapham, D. E. (2014) · Cell · doi:10.1016/j.cell.2014.02.056 · Cited by 257
Photocontrollable Fluorescent Proteins for Superresolution Imaging
Shcherbakova, D. M., Sengupta, P., Lippincott-Schwartz, J., & Verkhusha, V. V. (2014) · Annual Review of Biophysics · doi:10.1146/annurev-biophys-051013-022836 · Cited by 228
“The density of localized molecules critically influences the spatial resolution (57) because at least two proteins must be localized across the smallest unit of resolution in a superresolution image (Figure 2c).”
Self-citationUltrabright photoactivatable fluorophores created by reductive caging
Vaughan, J. C., Jia, S., & Zhuang, X. (2012) · Nature Methods · doi:10.1038/nmeth.2214 · Cited by 226
Single-Virus Tracking: From Imaging Methodologies to Virological Applications
Liu, S.-L., Wang, Z.-G., Xie, H.-Y., Liu, A.-A., Lamb, D. C., & Pang, D.-W. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00692 · Cited by 224
“500 Super-resolution methods are commercially available and have pushed the optical resolution into the 20−100 nm range.”
MethodAchieving the ultimate optical resolution
Paúr, M., Stoklasa, B., Hradil, Z., Sánchez-Soto, L. L., & Rehacek, J. (2016) · Optica · doi:10.1364/optica.3.001144 · Cited by 215
Burnette, D. T., Sengupta, P., Dai, Y., Lippincott-Schwartz, J., & Kachar, B. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1117430109 · Cited by 211
“Therefore, the development of microcopy techniques that produce images that circumvent the diffraction limit has been the topic of active research in recent years (1, 2).”
BackgroundSelf-citationMoon, S., Yan, R., Kenny, S. J., Shyu, Y., Xiang, L., Li, W., & Xu, K. (2017) · Journal of the American Chemical Society · doi:10.1021/jacs.7b03846 · Cited by 208
Gu, X., Zhao, E., Zhao, T., Kang, M., Gui, C., Lam, J. W. Y., Du, S., Loy, M. M. T., & Tang, B. Z. (2016) · Advanced Materials · doi:10.1002/adma.201505906 · Cited by 195
SRRF: Universal live-cell super-resolution microscopy
Culley, S., Tosheva, K. L., Matos Pereira, P., & Henriques, R. (2018) · The International Journal of Biochemistry & Cell Biology · doi:10.1016/j.biocel.2018.05.014 · Cited by 181
Multiparameter quantum metrology of incoherent point sources: Towards realistic superresolution
Řehaček, J., Hradil, Z., Stoklasa, B., Paúr, M., Grover, J., Krzic, A., & Sánchez-Soto, L. L. (2017) · Physical Review A · doi:10.1103/physreva.96.062107 · Cited by 169
Izeddin, I., El Beheiry, M., Andilla, J., Ciepielewski, D., Darzacq, X., & Dahan, M. (2012) · Optics Express · doi:10.1364/oe.20.004957 · Cited by 167
Fluorescence microscopy—A historical and technical perspective
Renz, M. (2013) · Cytometry Part A · doi:10.1002/cyto.a.22295 · Cited by 165
Labeling and Single-Molecule Methods To Monitor G Protein-Coupled Receptor Dynamics
Tian, H., Fürstenberg, A., & Huber, T. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00084 · Cited by 114
Metadata
- Authors
- Patterson, G., Davidson, M., Manley, S., & Lippincott-Schwartz, J.
- Venue
- Annual Review of Physical Chemistry
- Publisher
- Annual Reviews
- Published
- 2010-03-01
- Volume
- 61
- Issue
- 1
- Pages
- 345-367
- ISSN
- 0066-426X (ISSN-L)
- 1545-1593
- OpenAlex
- W2156853807
- Cited by
- 527
- References
- 84
- FWCI
- 5.05
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.