The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Nonenhanced MR Angiography
Abstract
While nonenhanced magnetic resonance (MR) angiographic methods have been available since the earliest days of MR imaging, prolonged acquisition times and image artifacts have generally limited their use in favor of gadolinium-enhanced MR angiographic techniques. However, the combination of recent technical advances and new concerns about the safety of gadolinium-based contrast agents has spurred a resurgence of interest in methods that do not require exogenous contrast material. After a review of basic considerations in vascular imaging, the established methods for nonenhanced MR angiographic techniques, such as time of flight and phase contrast, are considered and their advantages and disadvantages are discussed. This article then focuses on new techniques that are becoming commercially available, such as electrocardiographically gated partial-Fourier fast spin-echo methods and balanced steady-state free precession imaging both with and without arterial spin labeling. Challenges facing these methods and possible solutions are considered. Since different imaging techniques rely on different mechanisms of image contrast, recommendations are offered for which strategies may work best for specific angiographic applications. Developments on the horizon include techniques that provide time-resolved imaging for assessment of flow dynamics by using nonenhanced approaches.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
Sodickson, D. K., & Manning, W. J. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380414 · Cited by 2,142
Grobner, T. (2006) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfk062 · Cited by 1,859
Nephrogenic Systemic Fibrosis: Risk Factors and Incidence Estimation
Sadowski, E. A., Bennett, L. K., Chan, M. R., Wentland, A. L., Garrett, A. L., Garrett, R. W., & Djamali, A. (2007) · Radiology · doi:10.1148/radiol.2431062144 · Cited by 1,018
Gadolinium-enhanced MR aortography.
Prince, M. R. (1994) · Radiology · doi:10.1148/radiology.191.1.8134563 · Cited by 884
Time‐resolved contrast‐enhanced 3D MR angiography
Korosec, F. R., Frayne, R., Grist, T. M., & Mistretta, C. A. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360304 · Cited by 877
de Bazelaire, C. M. J., Duhamel, G. D., Rofsky, N. M., & Alsop, D. C. (2004) · Radiology · doi:10.1148/radiol.2303021331 · Cited by 792
Principles and applications of balanced SSFP techniques
Scheffler, K., & Lehnhardt, S. (2003) · European Radiology · doi:10.1007/s00330-003-1957-x · Cited by 714
Three‐dimensional phase contrast angiography
Dumoulin, C. L., Souza, S. P., Walker, M. F., & Wagle, W. (1989) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910090117 · Cited by 432
Pomposelli, F. B., Kansal, N., Hamdan, A. D., Belfield, A., Sheahan, M., Campbell, D. R., Skillman, J. J., & Logerfo, F. W. (2003) · Journal of Vascular Surgery · doi:10.1067/mva.2003.125 · Cited by 375
Estimating oxygen saturation of blood in vivo with MR imaging at 1.5 T
Wright, G. A., Hu, B. S., & Macovski, A. (1991) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880010303 · Cited by 327
Owen, R. S., Carpenter, J. P., Baum, R. A., Perloff, L. J., & Cope, C. (1992) · New England Journal of Medicine · doi:10.1056/nejm199206113262428 · Cited by 307
Peripheral vascular tree stenoses: evaluation with moving-bed infusion-tracking MR angiography.
Ho, K. Y., Leiner, T., de Haan, M. W., Kessels, A. G., Kitslaar, P. J., & van Engelshoven, J. M. (1998) · Radiology · doi:10.1148/radiology.206.3.9494486 · Cited by 301
MR angiography by multiple thin slab 3D acquisition
Parker, D. L., Yuan, C., & Blatter, D. D. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910170215 · Cited by 282
Highly constrained backprojection for time‐resolved MRI
Mistretta, C. A., Wieben, O., Velikina, J., Block, W., Perry, J., Wu, Y., Johnson, K., & Wu, Y. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20772 · Cited by 274
Perfusion Imaging Using Arterial Spin Labeling
Golay, X., Hendrikse, J., & Lim, T. C. C. (2004) · Topics in Magnetic Resonance Imaging · doi:10.1097/00002142-200402000-00003 · Cited by 256
The Loss of Small Objects in Variable TE Imaging: Implications for FSE, RARE, and EPI
Constable, R. T., & Gore, J. C. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910280103 · Cited by 245
Pulmonary Arterial Hypertension: Noninvasive Detection with Phase-Contrast MR Imaging
Sanz, J., Kuschnir, P., Rius, T., Salguero, R., Sulica, R., Einstein, A. J., Dellegrottaglie, S., Fuster, V., Rajagopalan, S., & Poon, M. (2007) · Radiology · doi:10.1148/radiol.2431060477 · Cited by 227
Peripheral Arterial Disease: Meta-analysis of the Diagnostic Performance of MR Angiography
Nelemans, P. J., Leiner, T., de Vet, H. C. W., & van Engelshoven, J. M. A. (2000) · Radiology · doi:10.1148/radiology.217.1.r00oc11105 · Cited by 219
Sakuma, H., Ichikawa, Y., Suzawa, N., Hirano, T., Makino, K., Koyama, N., CAUTEREN, M. V., & Takeda, K. (2005) · Radiology · doi:10.1148/radiol.2371040830 · Cited by 207
Bernstein, M. A., Huston, J., Lin, C., Gibbs, G. F., & Felmlee, J. P. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1282 · Cited by 206
MR angiography by selective inversion recovery
Nishimura, D. G., Macovski, A., Pauly, J. M., & Conolly, S. M. (1987) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910040214 · Cited by 171
Debatin, J. F., Ting, R. H., Wegmüller, H., Sommer, F. G., Fredrickson, J. O., Brosnan, T. J., Bowman, B. S., Myers, B. D., Herfkens, R. J., & Pelc, N. J. (1994) · Radiology · doi:10.1148/radiology.190.2.8284383 · Cited by 146
Carpenter, J. P., Baum, R. A., Holland, G. A., & Barker, C. F. (1994) · Journal of Vascular Surgery · doi:10.1016/0741-5214(94)90222-4 · Cited by 125
Niendorf, T., Hardy, C. J., Giaquinto, R. O., Gross, P., Cline, H. E., Zhu, Y., Kenwood, G., Cohen, S., Grant, A. K., Joshi, S., et al. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20923 · Cited by 124
Bypass to plantar and tarsal arteries: An acceptable approach to limb salvage
Hughes, K., Domenig, C. M., Hamdan, A. D., Schermerhorn, M. L., Aulivola, B., Blattman, S. B., Campbell, D. R., Scovell, S. D., LoGerfo, F. W., & Pomposelli, F. B. (2004) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2004.08.037 · Cited by 118
Quantitative ultrasonographic studies of lower extremity flow velocities in health and disease.
Fronek, A., Coel, M., & Berstein, E. F. (1976) · Circulation · doi:10.1161/01.cir.53.6.957 · Cited by 106
Gadolinium-Enhanced MR Angiography: Artifacts and Pitfalls
Lee, V. S., Martin, D. J., Krinsky, G. A., & Rofsky, N. M. (2000) · American Journal of Roentgenology · doi:10.2214/ajr.175.1.1750197 · Cited by 95
Self-citationThree‐dimensional flow‐independent peripheral angiography
Brittain, J. H., Olcott, E. W., Szuba, A., Gold, G. E., Wright, G. A., Pablo Irarrázaval, M., & Nishimura, D. G. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380302 · Cited by 90
Quantitation of renal perfusion using arterial spin labeling with FAIR-UFLARE
Karger, N., Biederer, J., Lüsse, S., Grimm, J., Steffens, J.-C., Heller, M., & Glüer, C.-C. (2000) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(00)00155-7 · Cited by 89
Spuentrup, E., Katoh, M., Buecker, A., Manning, W. J., Schaeffter, T., Nguyen, T.-H., Kühl, H. P., Stuber, M., Botnar, R. M., & Günther, R. W. (2004) · Radiology · doi:10.1148/radiol.2312030451 · Cited by 82
Jahnke, C., Paetsch, I., Schnackenburg, B., Bornstedt, A., Gebker, R., Fleck, E., & Nagel, E. C. (2004) · Radiology · doi:10.1148/radiol.2323031225 · Cited by 80
Tsukuda, T., Ito, K., Koike, S., et al. (2005) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20419 · Cited by 41
Liu, Y., Karonen, J. O., Vanninen, R. L., Nuutinen, J., Koskela, A., Soimakallio, S., & Aronen, H. J. (2004) · Radiology · doi:10.1148/radiol.2312030565 · Cited by 39
Kato, T., Indo, T., Yoshida, E., Iwasaki, Y., Sone, M., & Sobue, G. (2002) · PubMed Central · Cited by 38
Detection of main renal artery stenosis using phase-contrast cine MR angiography.
Silverman, J. M., Friedman, M. L., & Allan, R. J. V. (1996) · American Journal of Roentgenology · doi:10.2214/ajr.166.5.8615257 · Cited by 37
Quantitative Perfusion Imaging Using Arterial Spin Labeling
Williams, D. S. (2006) · Humana Press eBooks · doi:10.1385/1-59745-010-3:151 · Cited by 29
Arterial pulse wave velocity and risk factors for peripheral vascular disease
Kanda, T., Nakamura, E., Moritani, T., & Yamori, Y. (2000) · European Journal of Applied Physiology · doi:10.1007/s004210050644 · Cited by 26
Wentland, A. L., Korosec, F. R., Vigen, K. K., Wieben, O. E., Fine, J. P., & Grist, T. M. (2006) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20715 · Cited by 10
Cited by
Coverdale, N. S., Gati, J. S., Opalevych, O., Perrotta, A., & Shoemaker, J. K. (2014) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00285.2014 · Cited by 348
Evaluation of cuff-induced ischemia in the lower extremity by magnetic resonance oximetry
Langham, M. C., Floyd, T. F., Mohler, E. R., Magland, J. F., & Wehrli, F. W. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.08.068 · Cited by 46
Metadata
- Authors
- Miyazaki, M., & Lee, V. S.
- Venue
- Radiology
- Published
- 2008-07
- Volume
- 248
- Issue
- 1
- Pages
- 20-43
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2117886365
- Cited by
- 407
- References
- 39
- FWCI
- 24.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.