Potential Contribution of Computer-aided Detection to the Sensitivity of Screening Mammography
The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
PURPOSE: To determine the false-negative rate in screening mammography, the capability of computer-aided detection (CAD) to identify these missed lesions, and whether or not CAD increases the radiologists' recall rate. MATERIALS AND METHODS: All available screening mammograms that led to the detection of biopsy-proved cancer (n = 1,083) and the most recent corresponding prior mammograms (n = 427) were collected from 13 facilities. Panels of radiologists evaluated the retrospectively visible prior mammograms by means of blinded review. All mammograms were analyzed by a CAD system that marks features associated with cancer. The recall rates of 14 radiologists were prospectively measured before and after installation of the CAD system. RESULTS: At retrospective review, 67% (286 of 427) of screening mammography-detected breast cancers were visible on the prior mammograms. At independent, blinded review by panels of radiologists, 27% (115 of 427) were interpreted as warranting recall on the basis of a statistical evaluation index; and the CAD system correctly marked 77% (89 of 115) of these cases. The original attending radiologists' sensitivity was 79% (427 of [427 + 115]). There was no statistically significant increase in the radiologists' recall rate when comparing the values before (8.3%) with those after (7.6%) installation of the CAD system. CONCLUSION: The original attending radiologists had a false-negative rate of 21% (115 of [427 + 115]). CAD prompting could have potentially helped reduce this false-negative rate by 77% (89 of 115) without an increase in the recall rate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
REDUCTION IN MORTALITY FROM BREAST CANCER AFTER MASS SCREENING WITH MAMMOGRAPHY
Tabár, L., Gad, A., Holmberg, L. H., Ljungquist, U., Fagerberg, C. J. G., Baldetorp, L., Gröntoft, O., Lundström, B., Månson, J. C., Eklund, G., et al. (1985) · The Lancet · doi:10.1016/s0140-6736(85)92204-4 · Cited by 1,781
Breast cancer screening with mammography: overview of Swedish randomised trials
Nyström, L., Wall, S., Rutqvist, L. E., Lindgren, A., Lindqvist, M., Rydén, S., Andersson, J., Bjurstam, N., Fagerberg, G., Frisell, J., et al. (1993) · The Lancet · doi:10.1016/0140-6736(93)91067-v · Cited by 968
Miller, A. B., Baines, C. J., To, T. M., & Wall, C. (1992) · Europe PMC (PubMed Central) · Cited by 864
Analysis of cancers missed at screening mammography.
Bird, R. E., Wallace, T. W., & Yankaskas, B. C. (1992) · Radiology · doi:10.1148/radiology.184.3.1509041 · Cited by 820
UPDATE OF THE SWEDISH TWO-COUNTY PROGRAM OF MAMMOGRAPHIC SCREENING FOR BREAST CANCER
Tabàr, L., Fagerberg, G., Duffy, S. W., Day, N. E., Gad, A., & Gröntoft, O. (1992) · Radiologic Clinics of North America · doi:10.1016/s0033-8389(22)02494-0 · Cited by 731
Effect of Age, Breast Density, and Family History on the Sensitivity of First Screening Mammography
Kerlikowske, K. (1996) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1996.03540010035027 · Cited by 624
Efficacy of breast cancer screening by age. New results swedish two-county trial
Tabar, L., Fagerberg, G., Chen, H.-H., Duffy, S. W., Smart, C. R., Gad, A., & Smith, R. A. (1995) · Cancer · doi:10.1002/1097-0142(19950515)75:10<2507::aid-cncr2820751017>3.0.co;2-h · Cited by 557
Self-citationBenefit of independent double reading in a population-based mammography screening program.
Thurfjell, E. L., Lernevall, K. A., & Taube, A. A. (1994) · Radiology · doi:10.1148/radiology.191.1.8134580 · Cited by 406
Tabar, L., Fagerberg, G., Duffy, S. W., & Day, N. E. (1989) · Journal of Epidemiology and Community Health · doi:10.1136/jech.43.2.107 · Cited by 355
Self-citationKerlikowske, K., Grady, D., Barclay, J., Ernster, V., Frankel, S. D., Ominsky, S. H., & Sickles, E. A. (1998) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/90.23.1801 · Cited by 298
Self-citation
Cited by
Computer-aided diagnosis in medical imaging: historical review, current status and future potential
Doi, K. (2007) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2007.02.002 · Cited by 1,855
“[11] Warren-Burhenne LJ, Wood SA, D’Orsi CJ, et al.”
American Cancer Society Guidelines for Breast Cancer Screening: Update 2003
Smith, R. A., Saslow, D., Andrews Sawyer, K., Burke, W., Costanza, M. E., Evans, W. P., Foster, R. S., Hendrick, E., Eyre, H. J., & Sener, S. (2003) · CA: A Cancer Journal for Clinicians · doi:10.3322/canjclin.53.3.141 · Cited by 770
Freer, T. W., & Ulissey, M. J. (2001) · Radiology · doi:10.1148/radiol.2203001282 · Cited by 751
Detecting and classifying lesions in mammograms with Deep Learning
Ribli, D., Horváth, A., Unger, Z., Pollner, P., & Csabai, I. (2018) · Scientific Reports · doi:10.1038/s41598-018-22437-z · Cited by 696
Influence of Computer-Aided Detection on Performance of Screening Mammography
Fenton, J. J., Taplin, S. H., Carney, P. A., Abraham, L., Sickles, E. A., D'Orsi, C., Berns, E. A., Cutter, G., Hendrick, R. E., Barlow, W. E., et al. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa066099 · Cited by 619
Self-citationKim, H.-E., Kim, H. H., Han, B.-K., Kim, K. H., Han, K., Nam, H., Lee, E. H., & Kim, E.-K. (2020) · The Lancet Digital Health · doi:10.1016/s2589-7500(20)30003-0 · Cited by 525
Current status and future potential of computer-aided diagnosis in medical imaging
Doi, K. (2005) · The British Journal of Radiology · doi:10.1259/bjr/82933343 · Cited by 444
Birdwell, R. L., Ikeda, D. M., O’Shaughnessy, K. F., & Sickles, E. A. (2001) · Radiology · doi:10.1148/radiology.219.1.r01ap16192 · Cited by 428
Self-citationA review of automatic mass detection and segmentation in mammographic images
Oliver, A., Freixenet, J., Martí, J., Pérez, E., Pont, J., Denton, E. R. E., & Zwiggelaar, R. (2010) · Medical Image Analysis · doi:10.1016/j.media.2009.12.005 · Cited by 398
Andersson, I., Ikeda, D. M., Zackrisson, S., Ruschin, M., Svahn, T., Timberg, P., & Tingberg, A. (2008) · European Radiology · doi:10.1007/s00330-008-1076-9 · Cited by 343
Sechopoulos, I., Teuwen, J., & Mann, R. (2021) · Seminars in Cancer Biology · doi:10.1016/j.semcancer.2020.06.002 · Cited by 341
Computer-aided detection/diagnosis of breast cancer in mammography and ultrasound: a review
Jalalian, A., Mashohor, S. B. T., Mahmud, H. R., Saripan, M. I. B., Ramli, A. R. B., & Karasfi, B. (2013) · Clinical Imaging · doi:10.1016/j.clinimag.2012.09.024 · Cited by 337
A review of computer-aided diagnosis of breast cancer: Toward the detection of subtle signs
Rangayyan, R. M., Ayres, F. J., & Leo Desautels, J. E. (2007) · Journal of the Franklin Institute · doi:10.1016/j.jfranklin.2006.09.003 · Cited by 337
Gur, D., Sumkin, J. H., Rockette, H. E., Ganott, M., Hakim, C., Hardesty, L., Poller, W. R., Shah, R., & Wallace, L. (2004) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/djh067 · Cited by 306
Single Reading with Computer-Aided Detection for Screening Mammography
Gilbert, F. J., Astley, S. M., Gillan, M. G. C., Agbaje, O. F., Wallis, M. G., James, J., Boggis, C. R. M., & Duffy, S. W. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0803545 · Cited by 296
Robertson, S., Azizpour, H., Smith, K., & Hartman, J. (2018) · Translational Research · doi:10.1016/j.trsl.2017.10.010 · Cited by 295
Geras, K. J., Mann, R. M., & Moy, L. (2019) · Radiology · doi:10.1148/radiol.2019182627 · Cited by 295
Discrimination of Breast Cancer with Microcalcifications on Mammography by Deep Learning
Wang, J., Yang, X., Cai, H., Tan, W., Jin, C., & Li, L. (2016) · Scientific Reports · doi:10.1038/srep27327 · Cited by 291
Missed Breast Carcinoma: Pitfalls and Pearls
Majid, A. S., de Paredes, E. S., Doherty, R. D., Sharma, N. R., & Salvador, X. (2003) · RadioGraphics · doi:10.1148/rg.234025083 · Cited by 275
Computer-Aided Breast Cancer Detection Using Mammograms: A Review
Ganesan, K., Acharya, U. R., Chua, C. K., Min, L. C., Abraham, K. T., & Ng, K.-H. (2013) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2012.2232289 · Cited by 253
Peng, Y., Jiang, Y., Yang, C., Brown, J. B., Antic, T., Sethi, I., Schmid-Tannwald, C., Giger, M. L., Eggener, S. E., & Oto, A. (2013) · Radiology · doi:10.1148/radiol.13121454 · Cited by 250
Fitzgerald, R. (2001) · Clinical Radiology · doi:10.1053/crad.2001.0858 · Cited by 242
Screening Mammograms: Interpretation with Computer-aided Detection—Prospective Evaluation
Morton, M. J., Whaley, D. H., Brandt, K. R., & Amrami, K. K. (2006) · Radiology · doi:10.1148/radiol.2392042121 · Cited by 218
Baker, J. A., Rosen, E. L., Lo, J. Y., Gimenez, E. I., Walsh, R., & Soo, M. S. (2003) · American Journal of Roentgenology · doi:10.2214/ajr.181.4.1811083 · Cited by 210
Berg, W. A., D’Orsi, C. J., Jackson, V. P., Bassett, L. W., Beam, C. A., Lewis, R. S., & Crewson, P. E. (2002) · Radiology · doi:10.1148/radiol.2243011626 · Cited by 208
Self-citationSertel, O., Kong, J., Shimada, H., Catalyurek, U. V., Saltz, J. H., & Gurcan, M. N. (2009) · Pattern Recognition · doi:10.1016/j.patcog.2008.08.027 · Cited by 208
“There are several commercially available CAD systems that have been proven to improve the clinical diagnosis of radiology images for several modalities such as mamagraphy and computed tomography (CT) [5,6].”
BackgroundComputer-Aided Diagnosis and Artificial Intelligence in Clinical Imaging
Shiraishi, J., Li, Q., Appelbaum, D., & Doi, K. (2011) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2011.06.004 · Cited by 206
Bhooshan, N., Giger, M. L., Jansen, S. A., Li, H., Lan, L., & Newstead, G. M. (2010) · Radiology · doi:10.1148/radiol.09090838 · Cited by 193
Brem, R. F., Baum, J., Lechner, M., Kaplan, S., Souders, S., Naul, L. G., & Hoffmeister, J. (2003) · American Journal of Roentgenology · doi:10.2214/ajr.181.3.1810687 · Cited by 189
“where N found is the number of potentially missed cancer cases with subsequent screening mammograms that led to the diagnosis of cancer obtained 9–24 months after the potentially missed cancer mammogram [34].”
BackgroundMethodInfluentialComputer-aided Detection with Screening Mammography in a University Hospital Setting
Birdwell, R. L., Bandodkar, P., & Ikeda, D. M. (2005) · Radiology · doi:10.1148/radiol.2362040864 · Cited by 187
Aisen, A. M., Broderick, L. S., Winer-Muram, H., Brodley, C. E., Kak, A. C., Pavlopoulou, C., Dy, J., Shyu, C.-R., & Marchiori, A. (2003) · Radiology · doi:10.1148/radiol.2281020126 · Cited by 169
“Findings in other trials suggest that computer-based tools can substantially enhance diagnostic sensitivity (9,10).”
BackgroundEffectiveness of Computer-Aided Detection in Community Mammography Practice
Fenton, J. J., Abraham, L., Taplin, S. H., Geller, B. M., Carney, P. A., D'Orsi, C., Elmore, J. G., Barlow, W. E., & for the Breast Cancer Surveillance Consortium (2011) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/djr206 · Cited by 168
“However, small retrospective studies suggest that the performance impacts of CAD are similar when used in digital (43–46) and filmscreen environments (8,11,19).”
BackgroundSelf-citationAccuracy of Diagnostic Procedures: Has It Improved Over the Past Five Decades?
Berlin, L. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.06.1270 · Cited by 165
“Over the past decade, innumerable articles reporting on and discussing the results of these new technologies have appeared in the radiology literature [94].”
BackgroundDean, J. C., & Ilvento, C. C. (2006) · American Journal of Roentgenology · doi:10.2214/ajr.05.0111 · Cited by 163
“In another retrospective review, the sensitivity of CAD was 75% for masses and 99% for microcalcifications [7].”
BackgroundKong, J., Sertel, O., Shimada, H., Boyer, K. L., Saltz, J. H., & Gurcan, M. N. (2009) · Pattern Recognition · doi:10.1016/j.patcog.2008.10.035 · Cited by 161
“system as a second reader for diagnosis in the field of radiology has been shown to be safe and effective [24].”
BackgroundA Concentric Morphology Model for the Detection of Masses in Mammography
Eltonsy, N. H., Tourassi, G. D., & Elmaghraby, A. S. (2007) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.895460 · Cited by 161
“, [3], [8], and [9]), CAD sensitivity for masses is reportedly substantially lower ranging from 65% to 90% with less than one false positive detections per mammographic study (e.”
BackgroundImage based computer aided diagnosis system for cancer detection
Lee, H., & Chen, Y.-P. P. (2015) · Expert Systems with Applications · doi:10.1016/j.eswa.2015.02.005 · Cited by 158
Povyakalo, A. A., Alberdi, E., Strigini, L., & Ayton, P. (2013) · Medical Decision Making · doi:10.1177/0272989x12465490 · Cited by 79
Metadata
- Authors
- Warren Burhenne, L. J., Wood, S. A., D'Orsi, C. J., Feig, S. A., Kopans, D. B., O'Shaughnessy, K. F., Sickles, E. A., Tabar, L., Vyborny, C. J., & Castellino, R. A.
- Venue
- Radiology
- Published
- 2000-05
- Volume
- 215
- Issue
- 2
- Pages
- 554-562
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2078710233
- Cited by
- 554
- References
- 27
- FWCI
- 23.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.