Heterogeneity in conduit artery function in humans: impact of arterial size
Open accessThe DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
To determine whether conduit artery size affects functional responses, we compared the magnitude, time course, and eliciting shear rate stimulus for flow-mediated dilation (FMD) in healthy men ( n = 20; 31 ± 7 yr). Upper limb (brachial and radial) and lower limb (common and superficial femoral) FMD responses were simultaneously assessed, whereas popliteal responses were measured in the same subjects during a separate visit. Glyceryl trinitrate (GTN)-mediated responses were similarly examined. Edge detection and wall tracking of high-resolution B-mode arterial ultrasound images, combined with synchronized Doppler waveform envelope analysis, were used to calculate conduit artery diameter, blood flow, and shear rate continuously across the cardiac cycle. Baseline artery size correlated inversely with the FMD response ( r = −0.57, P < 0.001). Within-artery comparisons revealed a significant inverse correlation between artery size and FMD% for the radial ( r = −0.66, P = 0.001), brachial ( r = −0.55, P = 0.01), and popliteal artery ( r = −0.48, P = 0.03), but not for the superficial and common femoral artery. Normalization of FMD responses for differences in eliciting shear rate did not abolish the between-artery relationship for artery function and size ( r = −0.48, P < 0.001), suggesting that differences between artery function responses were not entirely due to size-related differences in shear rate. This was reinforced by a significant between-artery correlation for GTN responses and baseline artery size ( r = −0.74, P < 0.001). In summary, systematic differences exist in vascular function responses of conduit arteries that differ in size. This raises the possibility that differences in artery size within or between individuals may influence functional responses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Non-invasive detection of endothelial dysfunction in children and adults at risk of atherosclerosis
Celermajer, D. S., Sorensen, K. E., Gooch, V. M., Spiegelhalter, D. J., Miller, O. I., Sullivan, I. D., Lloyd, J. K., & Deanfield, J. E. (1992) · The Lancet · doi:10.1016/0140-6736(92)93147-f · Cited by 4,742 · cited 4×
“A relationship between artery diameter and FMD has been suggested previously in studies performed using betweensubjects comparisons of brachial (3, 12, 13, 25–27) or femoral (3, 28) responses.”
InfluentialTreatment of periodontitis and endothelial function
Tonetti, M. S., D'Aiuto, F., Nibali, L., Donald, A., Storry, C., Parkar, M., Suvan, J., Hingorani, A. D., Vallance, P., & Deanfield, J. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa063186 · Cited by 1,326 · cited 1×
“To support this, we recently reported (1) that the brachial artery peak dilation often occurs outside the commonly used time points (2, 3) or time windows (20, 29, 30, 33), leading to underestimation of the true FMD response and incorrect calculation of shear rate AUC.”
Prognostic Significance of Endothelial Dysfunction in Hypertensive Patients
Perticone, F., Ceravolo, R., Pujia, A., Ventura, G., Iacopino, S., Scozzafava, A., Ferraro, A., Chello, M., Mastroroberto, P., Verdecchia, P., et al. (2001) · Circulation · doi:10.1161/01.cir.104.2.191 · Cited by 1,059 · cited 1×
“Endothelial dysfunction can be considered an early and integral manifestation of vascular disease that predicts cardiovascular events (8, 15, 16, 18, 21), whereas improvement in endothelial function impacts significantly on cardiovascular risk (10, 11, 16).”
Effect of exercise training on endothelium‐derived nitric oxide function in humans
Green, D. J., Maiorana, A., O'Driscoll, G., & Taylor, R. (2004) · The Journal of Physiology · doi:10.1113/jphysiol.2004.068197 · Cited by 1,040 · cited 1×
“Endothelial dysfunction can be considered an early and integral manifestation of vascular disease that predicts cardiovascular events (8, 15, 16, 18, 21), whereas improvement in endothelial function impacts significantly on cardiovascular risk (10, 11, 16).”
Self-citationTounian, P., Aggoun, Y., Dubern, B., Varille, V., Guy-Grand, B., Sidi, D., Girardet, J.-P., & Bonnet, D. (2001) · The Lancet · doi:10.1016/s0140-6736(01)06525-4 · Cited by 811 · cited 1×
“To support this, we recently reported (1) that the brachial artery peak dilation often occurs outside the commonly used time points (2, 3) or time windows (20, 29, 30, 33), leading to underestimation of the true FMD response and incorrect calculation of shear rate AUC.”
Gokce, N., Keaney, J. F., Hunter, L. M., Watkins, M. T., Menzoian, J. O., & Vita, J. A. (2002) · Circulation · doi:10.1161/01.cir.0000012543.55874.47 · Cited by 783 · cited 1×
“Endothelial dysfunction can be considered an early and integral manifestation of vascular disease that predicts cardiovascular events (8, 15, 16, 18, 21), whereas improvement in endothelial function impacts significantly on cardiovascular risk (10, 11, 16).”
Endothelial Function: A Barometer for Cardiovascular Risk?
Vita, J. A., & Keaney, J. F. (2002) · Circulation · doi:10.1161/01.cir.0000028581.07992.56 · Cited by 737 · cited 2×
“For example, conduit artery vasodilation to a 5-min ischemic period, commonly referred to as flow-mediated dilation (FMD), reflects bioactivity of endothelium-derived nitric oxide (NO) (14, 17), which possesses myriad antiatherogenic effects (31).”
Pyke, K. E., & Tschakovsky, M. E. (2005) · The Journal of Physiology · doi:10.1113/jphysiol.2005.089755 · Cited by 614 · cited 2×
“In relative terms, this results in enhanced dilator responses compared with arteries of larger dimension (25, 27, 28).”
Prognostic role of reversible endothelial dysfunction in hypertensive postmenopausal women
Modena, M. G., Bonetti, L., Coppi, F., Bursi, F., & Rossi, R. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)01976-9 · Cited by 575 · cited 1×
“Endothelial dysfunction can be considered an early and integral manifestation of vascular disease that predicts cardiovascular events (8, 15, 16, 18, 21), whereas improvement in endothelial function impacts significantly on cardiovascular risk (10, 11, 16).”
Late prognostic value of flow-mediated dilation in the brachial artery of patients with chest pain
Neunteufl, T., Heher, S., Katzenschlager, R., Wölfl, G., Kostner, K., Maurer, G., & Weidinger, F. (2000) · The American Journal of Cardiology · doi:10.1016/s0002-9149(00)00857-2 · Cited by 554 · cited 1×
“Endothelial dysfunction can be considered an early and integral manifestation of vascular disease that predicts cardiovascular events (8, 15, 16, 18, 21), whereas improvement in endothelial function impacts significantly on cardiovascular risk (10, 11, 16).”
Improved analysis of brachial artery ultrasound using a novel edge-detection software system
Woodman, R. J., Playford, D. A., Watts, G. F., Cheetham, C., Reed, C., Taylor, R. R., Puddey, I. B., Beilin, L. J., Burke, V., Mori, T. A., et al. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.91.2.929 · Cited by 533 · cited 1×
“Ultimately, from these synchronized diameter and velocity data, blood flow [the product of cross-sectional area (CSA) and mean Doppler velocity (v)] and shear rate (4 times velocity divided by diameter) were calculated at 30 Hz (32).”
Self-citationFOLKOW, B., GRIYBY, G., & THULESIUS., O. (1958) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1958.tb01626.x · Cited by 509 · cited 4×
“Although artery size may act as a surrogate for wall composition or thickness (6, 7), we did not directly assess these factors in the present experiment.”
InfluentialFolkow, B. (1978) · Clinical Science · doi:10.1042/cs055003s · Cited by 403 · cited 4×
“Although artery size may act as a surrogate for wall composition or thickness (6, 7), we did not directly assess these factors in the present experiment.”
InfluentialImportance of Measuring the Time Course of Flow-Mediated Dilatation in Humans
Black, M. A., Cable, N. T., Thijssen, D. H. J., & Green, D. J. (2008) · Hypertension · doi:10.1161/hypertensionaha.107.101014 · Cited by 393 · cited 5×
“and continued for 6 min thereafter (1).”
InfluentialSelf-citationMullen, M. J., Kharbanda, R. K., Cross, J., Donald, A. E., Taylor, M., Vallance, P., Deanfield, J. E., & MacAllister, R. J. (2001) · Circulation Research · doi:10.1161/01.res.88.2.145 · Cited by 392 · cited 1×
“For example, conduit artery vasodilation to a 5-min ischemic period, commonly referred to as flow-mediated dilation (FMD), reflects bioactivity of endothelium-derived nitric oxide (NO) (14, 17), which possesses myriad antiatherogenic effects (31).”
Peak vs. total reactive hyperemia: which determines the magnitude of flow-mediated dilation?
Pyke, K. E., & Tschakovsky, M. E. (2007) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01024.2006 · Cited by 312 · cited 8×
“Pyke and Tschakovsky (24) examined the relationship between brachial artery size and the magnitude of the FMD response and found that 64% of the FMD response was explained by the artery size (r(2) 0.”
InfluentialExercise and cardiovascular risk reduction: Time to update the rationale for exercise?
Green, D. J., O'Driscoll, G., Joyner, M. J., & Cable, N. T. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01028.2007 · Cited by 284 · cited 1×
“Endothelial dysfunction can be considered an early and integral manifestation of vascular disease that predicts cardiovascular events (8, 15, 16, 18, 21), whereas improvement in endothelial function impacts significantly on cardiovascular risk (10, 11, 16).”
Self-citationPyke, K. E., Dwyer, E. M., & Tschakovsky, M. E. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01245.2003 · Cited by 258 · cited 2×
“Correcting the FMD response to the magnitude of the shear stress stimulus may eliminate the between-subject variability (23).”
Celermajer, D. S., Sorensen, K., Ryalls, M., Robinson, J., Thomas, O., Leonard, J. V., & Deanfield, J. E. (1993) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(93)90203-d · Cited by 252 · cited 1×
“To support this, we recently reported (1) that the brachial artery peak dilation often occurs outside the commonly used time points (2, 3) or time windows (20, 29, 30, 33), leading to underestimation of the true FMD response and incorrect calculation of shear rate AUC.”
Kuvin, J. T., Patel, A. R., Sliney, K. A., Pandian, N. G., Rand, W. M., Udelson, J. E., & Karas, R. H. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01657-6 · Cited by 248 · cited 1×
“Endothelial dysfunction can be considered an early and integral manifestation of vascular disease that predicts cardiovascular events (8, 15, 16, 18, 21), whereas improvement in endothelial function impacts significantly on cardiovascular risk (10, 11, 16).”
Flow‐mediated dilatation in the superficial femoral artery is nitric oxide mediated in humans
Kooijman, M., Thijssen, D. H. J., De Groot, P. C. E., Bleeker, M. W. P., Van Kuppevelt, H. J. M., Green, D. J., Rongen, G. A., Smits, P., & Hopman, M. T. E. (2008) · The Journal of Physiology · doi:10.1113/jphysiol.2007.145722 · Cited by 207 · cited 2×
“For example, conduit artery vasodilation to a 5-min ischemic period, commonly referred to as flow-mediated dilation (FMD), reflects bioactivity of endothelium-derived nitric oxide (NO) (14, 17), which possesses myriad antiatherogenic effects (31).”
Self-citationHerrington, D. M., Fan, L., Drum, M., Riley, W. A., Pusser, B. E., Crouse, J. R., Burke, G. L., McBurnie, M. A., Morgan, T. M., & Espeland, M. A. (2001) · European Journal of Cardiovascular Prevention & Rehabilitation · doi:10.1177/174182670100800512 · Cited by 187 · cited 2×
“The results of this study indicate that baseline artery size is inversely correlated with the FMD response, a finding that essentially confirms various previous reports (3, 12, 13, 26).”
Differential effects of aging on limb blood flow in humans
Donato, A. J., Uberoi, A., Wray, D. W., Nishiyama, S., Lawrenson, L., & Richardson, R. S. (2006) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00405.2005 · Cited by 169 · cited 1×
“To illustrate, recent studies that assessed FMD in the arm and leg (5, 19, 33, 34) have concluded that limb differences exist in FMD, possibly as a consequence of differences in activity level and/or arterial pressure.”
Green, D., Cheetham, C., Reed, C., Dembo, L., & O'Driscoll, G. (2002) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00051.2002 · Cited by 131 · cited 1×
“Furthermore, our method of blood flow assessment is closely correlated with actual flow through a “phantom” arterial flow system (9).”
Self-citationVascular Remodeling After “Successful” Repair of Coarctation
Ou, P., Celermajer, D. S., Mousseaux, É., Giron, A., Aggoun, Y., Szézépanski, I., Sidi, D., & Bonnet, D. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.10.057 · Cited by 130 · cited 1×
“To support this, we recently reported (1) that the brachial artery peak dilation often occurs outside the commonly used time points (2, 3) or time windows (20, 29, 30, 33), leading to underestimation of the true FMD response and incorrect calculation of shear rate AUC.”
Silber, H. A., Bluemke, D. A., Ouyang, P., Du, Y. P., Post, W. S., & Lima, J. A. C. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01649-7 · Cited by 129 · cited 3×
“33) are lower, other studies report comparable (27) or even lower values (23, 27) than those we observed.”
Silber, H. A., Ouyang, P., Bluemke, D. A., Gupta, S. N., Foo, T., & Lima, J. A. C. (2004) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00612.2004 · Cited by 111
Heterogeneous limb vascular responsiveness to shear stimuli during dynamic exercise in humans
Wray, D. W., Uberoi, A., Lawrenson, L., & Richardson, R. S. (2005) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01285.2004 · Cited by 98 · cited 2×
“This will be of special importance for conduit arteries in the lower limb, which recently have become a popular site of interest for functional assessments (14, 19, 34).”
Ultrasound settings significantly alter arterial lumen and wall thickness measurements
Potter, K., Reed, C. J., GREEN, D. J., Hankey, G. J., & Arnolda, L. (2008) · Cardiovascular Ultrasound · doi:10.1186/1476-7120-6-6 · Cited by 82 · cited 1×
“similar between the machines (22), and simultaneous imaging of two”
Self-citationEvidence of preserved endothelial function and vascular plasticity with age
Wray, D. W., Uberoi, A., Lawrenson, L., & Richardson, R. S. (2005) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00883.2005 · Cited by 79 · cited 2×
“To support this, we recently reported (1) that the brachial artery peak dilation often occurs outside the commonly used time points (2, 3) or time windows (20, 29, 30, 33), leading to underestimation of the true FMD response and incorrect calculation of shear rate AUC.”
Joannides, R., Costentin, A., Iacob, M., Compagnon, P., Lahary, A., & Thuillez, C. (2002) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00209.2001 · Cited by 75 · cited 2×
“The results of this study indicate that baseline artery size is inversely correlated with the FMD response, a finding that essentially confirms various previous reports (3, 12, 13, 26).”
Limb-specific differences in flow-mediated dilation: the role of shear rate
Nishiyama, S. K., Wray, D. W., Berkstresser, K. A., Ramaswamy, M., & Richardson, R. S. (2007) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00273.2007 · Cited by 61 · cited 2×
“This will be of special importance for conduit arteries in the lower limb, which recently have become a popular site of interest for functional assessments (14, 19, 34).”
Regional Heterogeneity of Arterial Structural Changes
Daemen, M. J. A. P., & Mey, J. G. R. D. (1995) · Hypertension · doi:10.1161/01.hyp.25.4.464 · Cited by 52 · cited 1×
“This, in turn, may influence functional responses (4).”
Cited by
Assessment of flow-mediated dilation in humans: a methodological and physiological guideline
Thijssen, D. H. J., Black, M. A., Pyke, K. E., Padilla, J., Atkinson, G., Harris, R. A., Parker, B., Widlansky, M. E., Tschakovsky, M. E., & Green, D. J. (2011) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00471.2010 · Cited by 1,483
Self-citationThe Assessment of Endothelial Function: From Research Into Clinical Practice
Flammer, A. J., Anderson, T., Celermajer, D. S., Creager, M. A., Deanfield, J., Ganz, P., Hamburg, N. M., Lüscher, T. F., Shechter, M., Taddei, S., et al. (2012) · Circulation · doi:10.1161/circulationaha.112.093245 · Cited by 1,153
Thijssen, D. H. J., Bruno, R. M., van Mil, A. C. C. M., Holder, S. M., Faita, F., Greyling, A., Zock, P. L., Taddei, S., Deanfield, J. E., Luscher, T., et al. (2019) · European Heart Journal · doi:10.1093/eurheartj/ehz350 · Cited by 995
Self-citationUltrasound Assessment of Flow-Mediated Dilation
Harris, R. A., Nishiyama, S. K., Wray, D. W., & Richardson, R. S. (2010) · Hypertension · doi:10.1161/hypertensionaha.110.150821 · Cited by 667
Arterial structure and function in vascular ageing: are you as old as your arteries?
Thijssen, D. H. J., Carter, S. E., & Green, D. J. (2016) · The Journal of Physiology · doi:10.1113/jp270597 · Cited by 220
“However, previous work has repeatedly demonstrated that conduit artery diameter is inversely correlated with vasodilator function (Celermajer et al. 1992; Silber et al. 2005; Thijssen et al. 2008).”
BackgroundSelf-citation
Metadata
- Authors
- Thijssen, D. H. J., Dawson, E. A., Black, M. A., Hopman, M. T. E., Cable, N. T., & Green, D. J.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 2008-11
- Volume
- 295
- Issue
- 5
- Pages
- H1927-H1934
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W1973920575
- Cited by
- 159
- References
- 33
- FWCI
- 7.48
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.