Magnetic resonance myocardial fiber-orientation mapping with direct histological correlation
The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
Functional properties of the myocardium are mediated by the tissue structure. Consequently, proper physiological studies and modeling necessitate a precise knowledge of the fiber orientation. Magnetic resonance (MR) diffusion tensor imaging techniques have been used as a nondestructive means to characterize tissue fiber structure; however, the descriptions so far have been mostly qualitative. This study presents a direct, quantitative comparison of high-resolution MR fiber mapping and histology measurements in a block of excised canine myocardium. Results show an excellent correspondence of the measured fiber angles not only on a point-by-point basis (average difference of −2.30 ± 0.98°, n = 239) but also in the transmural rotation of the helix angles (average correlation coefficient of 0.942 ± 0.008 with average false-positive probability of 0.004 ± 0.001, n = 24). These data strongly support the hypothesis that the eigenvector of the largest MR diffusion tensor eigenvalue coincides with the orientation of the local myocardial fibers and underscore the potential of MR imaging as a noninvasive, three-dimensional modality to characterize tissue fiber architecture.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Plum, F. (1960) · Archives of Neurology · doi:10.1001/archneur.1960.03840090124020 · Cited by 10,364
MR diffusion tensor spectroscopy and imaging
Basser, P. J., Mattiello, J., & LeBihan, D. (1994) · Biophysical Journal · doi:10.1016/s0006-3495(94)80775-1 · Cited by 5,970 · cited 1×
“musculature (4, 7, 12, 33), the MR technique has been”
MethodBasser, P. J., & Pierpaoli, C. (1996) · Journal of Magnetic Resonance, Series B · doi:10.1006/jmrb.1996.0086 · Cited by 4,306
Estimation of the Effective Self-Diffusion Tensor from the NMR Spin Echo
Basser, P. J., Mattiello, J., & Lebihan, D. (1994) · Journal of Magnetic Resonance, Series B · doi:10.1006/jmrb.1994.1037 · Cited by 3,650
Stoschitzky, K. (2000) · Handbooks in Pharmacology and Toxicology · doi:10.1201/9781420036961.ch18 · Cited by 2,956
Diffusion tensor MR imaging of the human brain
Pierpaoli, C., Jezzard, P., Basser, P. J., Barnett, A., & Di Chiro, G. (1996) · Radiology · doi:10.1148/radiology.201.3.8939209 · Cited by 2,664
Toward a quantitative assessment of diffusion anisotropy
Pierpaoli, C., & Basser, P. J. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360612 · Cited by 2,405
Processing strategies for time‐course data sets in functional mri of the human brain
Bandettini, P. A., Jesmanowicz, A., Wong, E. C., & Hyde, J. S. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300204 · Cited by 1,763
Fiber Orientation in the Canine Left Ventricle during Diastole and Systole
STREETER, D. D., SPOTNITZ, H. M., PATEL, D. P., ROSS, J., & SONNENBLICK, E. H. (1969) · Circulation Research · doi:10.1161/01.res.24.3.339 · Cited by 1,454
Stejskal, E. O. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1696526 · Cited by 894
Cited by
Pajevic, S., & Pierpaoli, C. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200006)43:6<921::aid-mrm23>3.0.co;2-i · Cited by 763
Spatial transformations of diffusion tensor magnetic resonance images
Alexander, D. C., Pierpaoli, C., Basser, P. J., & Gee, J. C. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.963816 · Cited by 610
Models of cardiac tissue electrophysiology: Progress, challenges and open questions
Clayton, R. H., Bernus, O., Cherry, E. M., Dierckx, H., Fenton, F. H., Mirabella, L., Panfilov, A. V., Sachse, F. B., Seemann, G., & Zhang, H. (2011) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2010.05.008 · Cited by 585
Bayer, J. D., Blake, R. C., Plank, G., & Trayanova, N. A. (2012) · Annals of Biomedical Engineering · doi:10.1007/s10439-012-0593-5 · Cited by 557
Scollan, D. F., Holmes, A., Winslow, R., & Forder, J. (1998) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1998.275.6.h2308 · Cited by 457
Regional nonuniformity of normal adult human left ventricle
Bogaert, J., & Rademakers, F. E. (2001) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.2001.280.2.h610 · Cited by 389
MR diffusion tensor imaging: recent advance and new techniques for diffusion tensor visualization
Masutani, Y., Aoki, S., Abe, O., Hayashi, N., & Otomo, K. (2003) · European Journal of Radiology · doi:10.1016/s0720-048x(02)00328-5 · Cited by 309
Diffusion Tensor MR Imaging of the Brain and White Matter Tractography
Melhem, E. R., Mori, S., Mukundan, G., Kraut, M. A., Pomper, M. G., & van Zijl, P. C. M. (2002) · American Journal of Roentgenology · doi:10.2214/ajr.178.1.1780003 · Cited by 304
Recruitment of Tendon Crimp With Applied Tensile Strain
Hansen, K. A., Weiss, J. A., & Barton, J. K. (2002) · Journal of Biomechanical Engineering · doi:10.1115/1.1427698 · Cited by 285
Measuring and Mapping Cardiac Fiber and Laminar Architecture Using Diffusion Tensor MR Imaging
HELM, P., BEG, M. F., MILLER, M. I., & WINSLOW, R. L. (2005) · Annals of the New York Academy of Sciences · doi:10.1196/annals.1341.026 · Cited by 250
Validation of diffusion tensor MRI‐based muscle fiber tracking
Damon, B. M., Ding, Z., Anderson, A. W., Freyer, A. S., & Gore, J. C. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10198 · Cited by 241
“Also, quantitative comparisons of the orientation of the eigenvector associated with the principal diffusivity have been made in in vitro cardiac (6,7,19) and striated (9,14) muscle.”
BackgroundVisualization of spiral and scroll waves in simulated and experimental cardiac tissue
Cherry, E. M., & Fenton, F. H. (2008) · New Journal of Physics · doi:10.1088/1367-2630/10/12/125016 · Cited by 236
“It has been shown that the fastest direction of water diffusion coincides with the local tissue fiber orientation, and fibers measured using DT-MRI have been correlated successfully with histological measurements made on freshly excised [77], perfused [78], and fixed cardiac preparations [79].”
BackgroundMethodSun, S., Neil, J. J., & Song, S. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10605 · Cited by 231
“The quantification and comparison of DTI parameters in vivo and ex vivo is a critical step in linking in vivo DTI findings to tissue microstructure by conventional histology (17,19).”
BackgroundEx vivo 3D diffusion tensor imaging and quantification of cardiac laminar structure
Helm, P. A., Tseng, H., Younes, L., McVeigh, E. R., & Winslow, R. L. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20622 · Cited by 227
“[9]”
A guide to modelling cardiac electrical activity in anatomically detailed ventricles
Clayton, R. H., & Panfilov, A. V. (2008) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2007.07.004 · Cited by 220
Sun, S.-W., Liang, H.-F., Le, T. Q., Armstrong, R. C., Cross, A. H., & Song, S.-K. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.04.212 · Cited by 218
A geometric analysis of diffusion tensor measurements of the human brain
Alexander, A. L., Hasan, K., Kindlmann, G., Parker, D. L., & Tsuruda, J. S. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200008)44:2<283::aid-mrm16>3.0.co;2-v · Cited by 212
“[3]–[5] are normalized and coupled so that the measurement of any two shape measures can be used to determine the third.”
MethodRemodeling of cardiac fiber structure after infarction in rats quantified with diffusion tensor MRI
Chen, J., Song, S.-K., Liu, W., McLean, M., Allen, J. S., Tan, J., Wickline, S. A., & Yu, X. (2003) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00889.2002 · Cited by 207
“By comparing DTMRI and conventional histological results, recent reports (9, 10, 22) have demonstrated a direct correlation between MRI and histological fiber angle measurements, thereby validating the DTMRI approach for complete characterization of myofiber architecture.”
ResultVisualizing diffusion tensor mr images using streamtubes and streamsurfaces
Zhang, S., Demiralp, C., & Laidlaw, D. H. (2003) · IEEE Transactions on Visualization and Computer Graphics · doi:10.1109/tvcg.2003.1260740 · Cited by 204
“Several groups have confirmed that, in the heart, the normalized major eigenvector of the diffusion tensor lies parallel to the local fiber tract direction [7], [9].”
BackgroundYu, C. S., Li, K. C., Xuan, Y., Ji, X. M., & Qin, W. (2005) · European Journal of Radiology · doi:10.1016/j.ejrad.2005.04.010 · Cited by 203
Geerts, L., Bovendeerd, P., Nicolay, K., & Arts, T. (2002) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00968.2001 · Cited by 200
“shown that the principal direction of the diffusion tensor corresponding to the largest diffusivity is statistically similar to the myofiber direction (10, 11, 20, 28).”
BackgroundChen, J., Liu, W., Zhang, H., Lacy, L., Yang, X., Song, S.-K., Wickline, S. A., & Yu, X. (2005) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00041.2005 · Cited by 197
“The primary eigenvector of the diffusion tensor is considered to be the myofiber orientation (11, 13, 14, 29), and the secondary and tertiary eigenvectors are considered to be the sheet and sheet-normal orientations, respectively (41).”
BackgroundMethodMyofiber Architecture of the Human Atria as Revealed by Submillimeter Diffusion Tensor Imaging
Pashakhanloo, F., Herzka, D. A., Ashikaga, H., Mori, S., Gai, N., Bluemke, D. A., Trayanova, N. A., & McVeigh, E. R. (2016) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.116.004133 · Cited by 193
Evidence of Structural Remodeling in the Dyssynchronous Failing Heart
Helm, P. A., Younes, L., Beg, M. F., Ennis, D. B., Leclercq, C., Faris, O. P., McVeigh, E., Kass, D., Miller, M. I., & Winslow, R. L. (2006) · Circulation Research · doi:10.1161/01.res.0000199396.30688.eb · Cited by 185
Lin, C.-P., Tseng, W.-Y. I., Cheng, H.-C., & Chen, J.-H. (2001) · NeuroImage · doi:10.1006/nimg.2001.0882 · Cited by 184
Patient-specific models of cardiac biomechanics
Krishnamurthy, A., Villongco, C. T., Chuang, J., Frank, L. R., Nigam, V., Belezzuoli, E., Stark, P., Krummen, D. E., Narayan, S., Omens, J. H., et al. (2013) · Journal of Computational Physics · doi:10.1016/j.jcp.2012.09.015 · Cited by 181
“Comparing histological measurements of the orientation of these fibers and sheets with results from DT-MRI measurements have confirmed that the fiber and sheet-normal directions coincide with the primary [21,19,37] and tertiary [17] eigenvectors.”
ResultNielles‐Vallespin, S., Mekkaoui, C., Gatehouse, P., Reese, T. G., Keegan, J., Ferreira, P. F., Collins, S., Speier, P., Feiweier, T., de Silva, R., et al. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24488 · Cited by 181
Leergaard, T. B., White, N. S., de Crespigny, A., Bolstad, I., D'Arceuil, H., Bjaalie, J. G., & Dale, A. M. (2010) · PLoS ONE · doi:10.1371/journal.pone.0008595 · Cited by 179
“However, while the orientation of the DT has been validated in large fiber bundles with coherent fiber orientations in brain [12–14] and myocardial tissues [15–17], the tensor model cannot be used to resolve multiple fiber bundles within voxels containing more than one principal direction [18].”
BackgroundMethodModelling passive diastolic mechanics with quantitative MRI of cardiac structure and function
Wang, V. Y., Lam, H. I., Ennis, D. B., Cowan, B. R., Young, A. A., & Nash, M. P. (2009) · Medical Image Analysis · doi:10.1016/j.media.2009.07.006 · Cited by 177
“A uthor M anuscript A uthor M anuscript A uthor M anuscript A uthor M anuscript established (Scollan et al., 1998; Hsu et al., 1998).”
BackgroundMapping Myocardial Fiber Orientation Using Echocardiography-Based Shear Wave Imaging
Lee, W.-N., Pernot, M., Couade, M., Messas, E., Bruneval, P., Bel, A., Hagege, A. A., Fink, M., & Tanter, M. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2172690 · Cited by 171
“DT-MRI has emerged as a promising imaging technique to visualize myocardial orientation in three-dimension, but its long data acquisition duration restricts its application in the in vivo scenario.”
MethodInfluentialGalbán, C. J., Maderwald, S., Uffmann, K., de Greiff, A., & Ladd, M. E. (2004) · European Journal of Applied Physiology · doi:10.1007/s00421-004-1186-2 · Cited by 169
“Diffusion tensor imaging (DTI), an MRI technique, has been used to non-invasively study the structure of various organs (Basser and Pierpaoli 1996; Hsu et al. 1998, 2001; Jones et al. 1999a; Ries et al. 2001).”
MethodDiffusion tensor MRI of myocardial fibers and sheets: Correspondence with visible cut‐face texture
Tseng, W. I., Wedeen, V. J., Reese, T. G., Smith, R. N., & Halpern, E. F. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10223 · Cited by 165
“[5] with f and d1 replaced by n and d3, respectively.”
BackgroundDetermination of mouse skeletal muscle architecture using three‐dimensional diffusion tensor imaging
Heemskerk, A. M., Strijkers, G. J., Vilanova, A., Drost, M. R., & Nicolay, K. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20476 · Cited by 160
“Extensive qualitative (14,30) and quantitative (8,31) evaluations of the DT have been performed.”
BackgroundPlank, G., Burton, R. A. B., Hales, P., Bishop, M., Mansoori, T., Bernabeu, M. O., Garny, A., Prassl, A. J., Bollensdorff, C., Mason, F., et al. (2009) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2009.0056 · Cited by 158
“There is very strong evidence, based on comparisons with histological data (Hsu et al. 1998; Scollan et al. 1998), that the primary eigenvector obtained using cardiac DT-MRI is locally aligned with the orientation of ventricular cardiac myocytes (usually, but potentially misleadingly, referred to as fibre orientation).”
Three-dimensional cardiac computational modelling: methods, features and applications.
Lopez-Perez, A., Sebastian, R., & Ferrero, J. M. (2015) · BioMedical Engineering OnLine · doi:10.1186/s12938-015-0033-5 · Cited by 151
“myocytes [73-75].”
Diffusion tensor imaging in biomechanical studies of skeletal muscle function
VAN DONKELAAR, C. C., KRETZERS, L. J. G., BOVENDEERD, P. H. M., LATASTER, L. M. A., NICOLAY, K., JANSSEN, J. D., & DROST, M. R. (1999) · Journal of Anatomy · doi:10.1046/j.1469-7580.1999.19410079.x · Cited by 141
Heart wall myofibers are arranged in minimal surfaces to optimize organ function
Savadjiev, P., Strijkers, G. J., Bakermans, A. J., Piuze, E., Zucker, S. W., & Siddiqi, K. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1120785109 · Cited by 62
Kaufman, J. A., Ahrens, E. T., Laidlaw, D. H., Zhang, S., & Allman, J. M. (2005) · The Anatomical Record Part A: Discoveries in Molecular, Cellular, and Evolutionary Biology · doi:10.1002/ar.a.20264 · Cited by 54
“In isolated rabbit myocardium, DTI data on muscle fiber orientation have been shown to correlate well with orientation measurements performed directly on histological preparations subsequent to scanning (Hsu et al., 1998; Scollan et al., 1998; Holmes et al., 2000).”
BackgroundMethodCarruth, E. D., McCulloch, A. D., & Omens, J. H. (2016) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2016.11.004 · Cited by 38
“Subsequent studies have verified this fiber architecture, and many have shown that it can be detected via Diffusion Tensor Magnetic Resonance Imaging (DT-MRI) (Holmes et al., 2000), (Hsu et al., 1998), (Scollan et al., 1998).”
BackgroundSmall animal cardiovascular MR imaging and spectroscopy
Bakermans, A. J., Abdurrachim, D., Moonen, R. P. M., Motaal, A. G., Prompers, J. J., Strijkers, G. J., Vandoorne, K., & Nicolay, K. (2015) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2015.03.001 · Cited by 35
Stephenson, R. S., Agger, P., Lunkenheimer, P. P., Zhao, J., Smerup, M., Niederer, P., Anderson, R. H., & Jarvis, J. C. (2016) · Clinical Anatomy · doi:10.1002/ca.22661 · Cited by 33
“Such investigations have produced fairly good agreement with the more traditional methods (Gilbert et al., 2012b; Holmes et al., 2000; Hsu et al., 1998).”
ResultAgger, P., Ilkjær, C., Laustsen, C., Smerup, M., Frandsen, J. R., Ringgaard, S., Pedersen, M., Partridge, J. B., Anderson, R. H., & Hjortdal, V. (2016) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-017-0404-0 · Cited by 28
“It has been extensively used to characterise myocardial architecture in autopsied [11] and beating hearts [12], in both health [13] and disease [6], and has been used in a variety of species.”
BackgroundGrussu, F., Schneider, T., Yates, R. L., Zhang, H., Wheeler-Kingshott, C. A. M. G., DeLuca, G. C., & Alexander, D. C. (2016) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2016.08.002 · Cited by 26
Carruth, E. D., Teh, I., Schneider, J. E., McCulloch, A. D., Omens, J. H., & Frank, L. R. (2020) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-020-00615-1 · Cited by 12
“Others have used a similar approach to validate that the eigenvectors correspond with local helix and sheet orientations [21, 22], and more recently, that the eigenvalues correlate with collagen content [27, 46].”
MethodAssessing Myocardial Architecture: The Challenges and Controversies
Agger, P., & Stephenson, R. S. (2020) · Journal of Cardiovascular Development and Disease · doi:10.3390/jcdd7040047 · Cited by 11
“Since the beginning of the 1990s, diffusion tensor magnetic resonance imaging has been extensively used in the experimental setting to characterise myocardial architecture in both autopsied [21] and beating hearts [22].”
Background
Metadata
- Authors
- Hsu, E. W., Muzikant, A. L., Matulevicius, S. A., Penland, R. C., & Henriquez, C. S.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1998-05-01
- Volume
- 274
- Issue
- 5
- Pages
- H1627-H1634
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2120776981
- Cited by
- 386
- References
- 34
- FWCI
- 10.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.