A comparison of bioimpedance methods for detection of body cell mass change in HIV infection
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
The maintenance of body cell mass (BCM) is critical for survival in human immunodeficiency virus (HIV) infection. Accuracy of bioimpedance for measuring change (Δ) in intracellular water (ICW), which defines BCM, is uncertain. To evaluate bioimpedance-estimated ΔBCM, the ICW of 21 weight-losing HIV patients was measured before and after anabolic steroid therapy by dilution (total body water by deuterium − extracellular water by bromide) and bioimpedance. Multiple-frequency modeling- and dilution-determined ΔICW did not differ. The ΔICW was predicted poorly by 50-kHz parallel reactance, 50-kHz impedance, and 200 − 5-kHz impedance. The ΔICW predicted by 500 − 5-kHz impedance was closer to, but statistically different from, dilution-determined ΔICW. However, the effect of random error on the measurement of systematic error in the 500 − 5-kHz method was 12–13% of the average measured ΔICW; this was nearly twice the percent difference between obtained and threshold statistics. Although the 500 − 5-kHz method cannot be fully rejected, these results support the conclusion that only the multiple-frequency modeling approach accurately monitors ΔBCM in HIV infection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Total body water measurement in humans with 18O and 2H labeled water
Schoeller, D. A., van Santen, E., Peterson, D. W., Dietz, W., Jaspan, J., & Klein, P. D. (1980) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/33.12.2686 · Cited by 666
Kotler, D., Burastero, S., Wang, J., & Pierson, R. (1996) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/64.3.489s · Cited by 472 · cited 12×
“A third group of investigators proposes that BCM can be adequately measured by a fixed, single-frequency 50-kHz measurement of impedance (Z) (43) or reactance (X) transformed into parallel X (XP) (7, 25, 31).”
BackgroundMethodInfluentialForbes, G. B. (1987) · doi:10.1007/978-1-4612-4654-1 · Cited by 431
Is the Impedance index (ht2/R) significant in predicting total body water?
Kushner, R., Schoeller, D., Fjeld, C., & Danford, L. (1992) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/56.5.835 · Cited by 374
Segal, K., Burastero, S., Chun, A., Coronel, P., Pierson, R., & Wang, J. (1991) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/54.1.26 · Cited by 311 · cited 2×
“evaluated (14, 50) resulted in predictions similar to”
ResultNutritional assessment with bioelectrical impedance analysis in maintenance hemodialysis patients.
Chertow, G. M., Lowrie, E. G., Wilmore, D. W., Gonzalez, J., Lew, N. L., Ling, J., Leboff, M. S., Gottlieb, M. N., Huang, W., & Zebrowski, B. (1995) · Journal of the American Society of Nephrology · doi:10.1681/asn.v6175 · Cited by 257
Hydration of fat-free body mass: new physiological modeling approach
Wang, Z., Deurenberg, P., Wang, W., Pietrobelli, A., Baumgartner, R. N., & Heymsfield, S. B. (1999) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1999.276.6.e995 · Cited by 158
Cited by
Bioelectrical impedance analysis?part I: review of principles and methods
KYLE, U. (2004) · Clinical Nutrition · doi:10.1016/j.clnu.2004.06.004 · Cited by 3,200
Bioelectrical impedance analysis—part II: utilization in clinical practice
Kyle, U. G., Bosaeus, I., De Lorenzo, A. D., Deurenberg, P., Elia, M., Manuel Gómez, J., Lilienthal Heitmann, B., Kent-Smith, L., Melchior, J.-C., Pirlich, M., et al. (2004) · Clinical Nutrition · doi:10.1016/j.clnu.2004.09.012 · Cited by 2,350
“Lack of portability of empirically derived algorithms, particularly for ECW estimation, suggests that the fundamental model underlying estimation of body fluids by MF-BIA and BIS is inadequate B HIV 33 ECW NaBr 0.54–0.55 Earthman et al.101 HIV 21 TBW 2H2O HannanR200 120 Xitron 0.97 1.2 TBW prediction by Kotler gave hi…”
BackgroundInfluentialKhalil, S., Mohktar, M., & Ibrahim, F. (2014) · Sensors · doi:10.3390/s140610895 · Cited by 712
“Hanai’s mixture theory shows limitations in some studies [14,15,34], however it showed advantages in other studies [35,36].”
ResultFat-free mass index and fat mass index percentiles in Caucasians aged 18–98 y
Schutz, Y., Kyle, U., & Pichard, C. (2002) · International Journal of Obesity · doi:10.1038/sj.ijo.0802037 · Cited by 670
Jaffrin, M. Y., & Morel, H. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2008.06.009 · Cited by 490
Body composition interpretation
Kyle, U. G., Schutz, Y., Dupertuis, Y. M., & Pichard, C. (2003) · Nutrition · doi:10.1016/s0899-9007(03)00061-3 · Cited by 456
Fat-free and fat mass percentiles in 5225 healthy subjects aged 15 to 98 years
Kyle, U. G., Genton, L., Slosman, D. O., & Pichard, C. (2001) · Nutrition · doi:10.1016/s0899-9007(01)00555-x · Cited by 440
Bioimpedance at the Bedside: Current Applications, Limitations, and Opportunities
Mulasi, U., Kuchnia, A. J., Cole, A. J., & Earthman, C. P. (2015) · Nutrition in Clinical Practice · doi:10.1177/0884533614568155 · Cited by 337
Self-citationLukaski, H. C. (2013) · European Journal of Clinical Nutrition · doi:10.1038/ejcn.2012.149 · Cited by 303
Earthman, C. P. (2015) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/0148607115595227 · Cited by 234
“BIS devices may be somewhat more variable, due to the technical difficulties in producing stable measurements at the extremes of frequencies, but even most BIS devices have been reported to produce fairly precise measurements (2%–3%).(46,106) Based on these precision estimates, the sensitivity of BIA/BIS techniques to…”
BackgroundMethodSelf-citationBioimpedance Spectroscopy for Clinical Assessment of Fluid Distribution and Body Cell Mass
Earthman, C., Traughber, D., Dobratz, J., & Howell, W. (2007) · Nutrition in Clinical Practice · doi:10.1177/0115426507022004389 · Cited by 209
Self-citationBioimpedance measurements of human body composition: critical analysis and outlook
Matthie, J. R. (2008) · Expert Review of Medical Devices · doi:10.1586/17434440.5.2.239 · Cited by 199
Self-citationAssessment of hydration status in a large population
Baron, S., Courbebaisse, M., Lepicard, E. M., & Friedlander, G. (2015) · British Journal of Nutrition · doi:10.1017/s0007114514003213 · Cited by 166
Prevalence of anxiety and depression in patients with overweight and obesity.
Sharafi, S. E., Garmaroudi, G., Ghafouri, M., Bafghi, S. A., Ghafouri, M., Tabesh, M. R., & Alizadeh, Z. (2020) · Obesity Medicine · doi:10.1016/j.obmed.2019.100169 · Cited by 98
Dioum, A., Gartner, A., Cissé, A. S., Delpeuch, F., Maire, B., Wade, S., & Schutz, Y. (2005) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/81.3.597 · Cited by 27
“The Xitron 4000B BIA device we used showed no significant differences from the RJL 101 device (41) used for producing 20 of the 23 equations tested.”
Method
Metadata
- Authors
- Earthman, C. P., Matthie, J. R., Reid, P. M., Harper, I. T., Ravussin, E., & Howell, W. H.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2000-03-01
- Volume
- 88
- Issue
- 3
- Pages
- 944-956
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2170027612
- Cited by
- 90
- References
- 7
- FWCI
- 2.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.