CoChat

Effect of graded fructose coingestion with maltodextrin on exogenous 14C-fructose and 13C-glucose oxidation efficiency and high-intensity cycling performance

Rowlands, David S., Thorburn, Megan S., Thorp, Rhys M., Broadbent, Suzanne, Shi, Xiaocai · 2008 · Journal of Applied Physiology
Cited by 72

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

Abstract

The ingestion of solutions containing carbohydrates with different intestinal transport mechanisms (e.g., fructose and glucose) produce greater carbohydrate and water absorption compared with single-carbohydrate solutions. However, the fructose-ingestion rate that results in the most efficient use of exogenous carbohydrate when glucose is ingested below absorption-oxidation saturation rates is unknown. Ten cyclists rode 2 h at 50% of peak power then performed 10 maximal sprints while ingesting solutions containing 13 C-maltodextrin at 0.6 g/min combined with 14 C-fructose at 0.0 (No-Fructose), 0.3 (Low-Fructose), 0.5 (Medium-Fructose), or 0.7 (High-Fructose) g/min, giving fructose:maltodextrin ratios of 0.5, 0. 8, and 1.2. Mean (percent coefficient of variation) exogenous-fructose oxidation rates during the 2-h rides were 0.18 ( 19 ), 0.27 ( 27 ), 0.36 ( 27 ) g/min in Low-Fructose, Medium-Fructose, and High-Fructose, respectively, with oxidation efficiencies (=oxidation/ingestion rate) of 62–52%. Exogenous-glucose oxidation was highest in Medium-Fructose at 0.57 ( 28 ) g/min (98% efficiency) compared with 0.54 ( 28 ), 0.48 ( 29 ), and 0.49 ( 19 ) in Low-Fructose, High-Fructose, No-Fructose, respectively; relative to No-Fructose, only the substantial 16% increase (95% confidence limits ±16%) in Medium-Fructose was clear. Total exogenous-carbohydrate oxidation was highest in Medium-Fructose at 0.84 ( 26 ) g/min. Although the effect of fructose quantity on overall sprint power was unclear, the metabolic responses were associated with lower perceptions of muscle tiredness and physical exertion, and attenuated fatigue (power slope) in the Medium-Fructose and High-Fructose conditions. With the present solutions, low-medium fructose-ingestion rates produced the most efficient use of exogenous carbohydrate, but fatigue and the perception of exercise stress and nausea are reduced with moderate-high fructose doses.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/japplphysiol.00878.2007

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 72

Metadata

Authors
Rowlands, D. S., Thorburn, M. S., Thorp, R. M., Broadbent, S., & Shi, X.
Venue
Journal of Applied Physiology
Published
2008-06
Volume
104
Issue
6
Pages
1709-1719
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2137490143
Cited by
72
References
14
FWCI
2.50
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.