Effects of prior heavy-intensity exercise on pulmonary O2 uptake and muscle deoxygenation kinetics in young and older adult humans
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Pulmonary O 2 uptake (V̇o 2p) and muscle deoxygenation kinetics were examined during moderate-intensity cycling (80% lactate threshold) without warm-up and after heavy-intensity warm-up exercise in young ( n = 6; 25 ± 3 yr) and older ( n = 5; 68 ± 3 yr) adults. We hypothesized that heavy warm-up would speed V̇o 2p kinetics in older adults consequent to an improved intramuscular oxygenation. Subjects performed step transitions ( n = 4; 6 min) from 20 W to moderate-intensity exercise preceded by either no warm-up or heavy-intensity warm-up (6 min). V̇o 2p was measured breath by breath. Oxy-, deoxy-(HHb), and total hemoglobin and myoglobin (Hb tot) of the vastus lateralis muscle were measured continuously by near-infrared spectroscopy (NIRS). V̇o 2p (phase 2; τ) and HHb data were fit with a monoexponential model. After heavy-intensity warm-up, oxyhemoglobin (older subjects: 13 ± 9 μM; young subjects: 9 ± 8 μM) and Hb tot (older subjects: 12 ± 8 μM; young subjects: 14 ± 10 μM) were elevated ( P < 0.05) relative to the no warm-up pretransition baseline. In older adults, τV̇o 2p adapted at a faster rate ( P < 0.05) after heavy warm-up (30 ± 7 s) than no warm-up (38 ± 5 s), whereas in young subjects, τV̇o 2p was similar in no warm-up (26 ± 7 s) and heavy warm-up (25 ± 5 s). HHb adapted at a similar rate in older and young adults after no warm-up; however, in older adults after heavy warm-up, the adaptation of HHb was slower ( P < 0.01) compared with young and no warm-up. These data suggest that, in older adults, V̇o 2p kinetics may be limited by a slow adaptation of muscle blood flow and O 2 delivery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Validation of near-infrared spectroscopy in humans
Mancini, D. M., Bolinger, L., Li, H., Kendrick, K., Chance, B., & Wilson, J. R. (1994) · Journal of Applied Physiology · doi:10.1152/jappl.1994.77.6.2740 · Cited by 669 · cited 2×
“However, Mb levels are small relative to those of Hb, and several studies (10, 12, 32, 42) have suggested that intracellular Mb contributes 10% to the total NIRS signal.”
BackgroundRecovery from exercise-induced desaturation in the quadriceps muscles of elite competitive rowers
Chance, B., Dait, M. T., Zhang, C., Hamaoka, T., & Hagerman, F. (1992) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1992.262.3.c766 · Cited by 528
Monitoring tissue oxygen availability with near infrared spectroscopy (NIRS) in health and disease
Boushel, R., Langberg, H., Olesen, J., Gonzales‐Alonzo, J., Bülow, J., & Kjær, M. (2001) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1034/j.1600-0838.2001.110404.x · Cited by 469
Grassi, B., Pogliaghi, S., Rampichini, S., Quaresima, V., Ferrari, M., Marconi, C., & Cerretelli, P. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00695.2002 · Cited by 429
Research works printed but not linked: 43
- 10.1249/00005768-199404000-00008 · DOI · Paper page
- 10.1249/00005768-199404000-00007 · DOI · Paper page
- 10.1152/ajpregu.2000.279.3.R899 · DOI · Paper page
- 10.1152/jappl.1981.51.6.1662 · DOI · Paper page
- Belardinelli R, Barstow TJ, Porszasz J, and Wasserman K. Skeletal muscle oxygenation during constant work rate exercise. Med Sci Sports Exerc 27: 512–519, 1995. · DOI · Paper page
- 10.1111/j.1469-445X.1999.01863.x · DOI
- 10.1113/eph8602209 · DOI
- 10.1113/expphysiol.1998.sp004138 · DOI
- 10.1046/j.1365-201x.2000.00713.x · DOI · Paper page
- 10.1007/s004210050471 · DOI
- 10.1139/h96-015 · DOI · Paper page
- 10.1152/jappl.1996.81.3.1388 · DOI · Paper page
- 10.1016/0034-5687(93)90088-R · DOI
- 10.1007/BF00377698 · DOI · Paper page
- 10.1152/jappl.1994.76.3.1388 · DOI · Paper page
- 10.1113/jphysiol.1991.sp018764 · DOI · Paper page
- 10.1152/japplphysiol.01179.2003 · DOI · Paper page
- 10.1152/japplphysiol.00956.2002 · DOI · Paper page
- 10.1161/01.CIR.100.2.164 · DOI · Paper page
- 10.1111/j.1469-7793.2001.0573i.x · DOI · Paper page
- 10.1111/j.1469-7793.2001.00977.x · DOI · Paper page
- 10.1088/0031-9155/40/2/007 · DOI · Paper page
- 10.1098/rstb.1997.0049 · DOI · Paper page
- 10.1152/jappl.1996.80.1.99 · DOI · Paper page
- 10.1164/arrd.1984.129.2P2.S68 · DOI
- 10.1152/jappl.1997.83.4.1318 · DOI · Paper page
- 10.1249/00005768-198906000-00011 · DOI
- 10.1152/ajpheart.00666.2001 · DOI
- 10.1152/ajpheart.00004.2002 · DOI · Paper page
- 10.1152/jappl.1995.79.6.1914 · DOI · Paper page
- 10.1152/jappl.1995.79.6.2050 · DOI · Paper page
- 10.1152/ajpheart.00790.2002 · DOI · Paper page
- 10.1152/japplphysiol.00898.2002 · DOI · Paper page
- 10.1152/jappl.1998.85.1.68 · DOI · Paper page
- 10.1152/japplphysiol.00186.2001 · DOI · Paper page
- 10.1093/oxfordjournals.jbchem.a122285 · DOI · Paper page
- 10.1161/01.CIR.91.7.1981 · DOI · Paper page
- 10.1139/y93-019 · DOI
- 10.1152/ajpregu.1999.276.6.R1682 · DOI · Paper page
- 10.1152/jappl.2001.90.2.511 · DOI · Paper page
- 10.1007/978-1-4615-3404-4_17 · DOI · Paper page
- 10.3109/00365517409114201 · DOI · Paper page
- 10.1113/jphysiol.1994.sp020365 · DOI · Paper page
Cited by
Aerobic exercise improves self-reported sleep and quality of life in older adults with insomnia
Reid, K. J., Baron, K. G., Lu, B., Naylor, E., Wolfe, L., & Zee, P. C. (2010) · Sleep Medicine · doi:10.1016/j.sleep.2010.04.014 · Cited by 665
Poole, D. C., & Jones, A. M. (2012) · Comprehensive Physiology · doi:10.1002/cphy.c100072 · Cited by 514
Hamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2805437 · Cited by 329
Bailey, S. J., Wilkerson, D. P., DiMenna, F. J., & Jones, A. M. (2009) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00144.2009 · Cited by 194
“The deoxyhemoglobin/myoglobin concentration ([HHb]) signal derived from near-infrared spectroscopy (NIRS) measurements reflects the balance between O2 delivery and O2 utilization in the field of interrogation and has been used to provide a noninvasive estimate of fractional O2 extraction in the microcirculation during…”
BackgroundResultRoman, M. A., Rossiter, H. B., & Casaburi, R. (2016) · European Respiratory Journal · doi:10.1183/13993003.00347-2016 · Cited by 194
Metadata
- Authors
- DeLorey, D. S., Kowalchuk, J. M., & Paterson, D. H.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2004-09
- Volume
- 97
- Issue
- 3
- Pages
- 998-1005
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2137700294
- Cited by
- 128
- References
- 4
- FWCI
- 16.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.