Restoring communication for people with locked-in syndrome remains a challenging clinical problem without a reliable solution. Recent studies have shown that people with paralysis can use brain-computer interfaces (BCIs) based on intracortical spiking activity to efficiently type messages. However, due to neuronal signal instability, most intracortical BCIs have required frequent calibration and continuous assistance of skilled engineers to maintain performance. Here, an individual with locked-in syndrome due to brain stem stroke and an individual with tetraplegia secondary to amyotrophic lateral sclerosis (ALS) used a simple communication BCI based on intracortical local field potentials (LFPs) for 76 and 138 days, respectively, without recalibration and without significant loss of performance. BCI spelling rates of 3.07 and 6.88 correct characters/minute allowed the participants to type messages and write emails. Our results indicate that people with locked-in syndrome could soon use a slow but reliable LFP-based BCI for everyday communication without ongoing intervention from a technician or caregiver. NEW & NOTEWORTHY This study demonstrates, for the first time, stable repeated use of an intracortical brain-computer interface by people with tetraplegia over up to four and a half months. The approach uses local field potentials (LFPs), signals that may be more stable than neuronal action potentials, to decode participants’ commands. Throughout the several months of evaluation, the decoder remained unchanged; thus no technical interventions were required to maintain consistent brain-computer interface operation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
Brain–computer interface–based communication in the completely locked-in State
Chaudhary, U., Xia, B., Silvoni, S., Cohen, L. G., & Birbaumer, N. (2017) · PLOS Biology · doi:10.1371/journal.pbio.1002593 · Cited by 235 · cited 3×
“…showed that near-infrared spectroscopy (NIRS) can be used to detect recognition of the veracity of a Boolean choice in people with complete LIS (Chaudhary et al. 2017; Gallegos-Ayala et al. 2014), which suggests that some people with complete LIS might remain capable of communication with…”
MethodRetractedThe origin of extracellular fields and currents — EEG, ECoG, LFP and spikes
Buzsáki, G., Anastassiou, C. A., & Koch, C. (2012) · Nature Reviews Neuroscience · doi:10.1038/nrn3241 · Cited by 4,225 · cited 1×
“In addition to spiking signals, intracortically implanted microelectrodes also record local field potentials (LFPs), neuronal signals thought to represent the summed activity of neuronal populations in the vicinity of the microelectrode (Buzsáki et al. 2012).”
BackgroundNeuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295 · cited 2×
“1997) using a previously described procedure (Hochberg et al. 2006).”
MethodSelf-citationReach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719
Self-citationHigh-performance neuroprosthetic control by an individual with tetraplegia
Collinger, J. L., Wodlinger, B., Downey, J. E., Wang, W., Tyler-Kabara, E. C., Weber, D. J., McMorland, A. J., Velliste, M., Boninger, M. L., & Schwartz, A. B. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61816-9 · Cited by 1,848
A spelling device for the paralysed
Birbaumer, N., Ghanayim, N., Hinterberger, T., Iversen, I., Kotchoubey, B., Kübler, A., Perelmouter, J., Taub, E., & Flor, H. (1999) · Nature · doi:10.1038/18581 · Cited by 1,577 · cited 4×
“Other studies have investigated the use of communication BCIs based on other signal modalities as a communication tool for people with LIS (Bacher et al. 2015; Birbaumer et al. 1999; Kübler et al. 1999, 2005; Nijboer et al. 2008; Sellers et al. 2014).”
BackgroundMethodInfluentialHigh-speed spelling with a noninvasive brain–computer interface
Chen, X., Wang, Y., Nakanishi, M., Gao, X., Jung, T.-P., & Gao, S. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1508080112 · Cited by 969
Brain–computer interfaces for communication and rehabilitation
Chaudhary, U., Birbaumer, N., & Ramos-Murguialday, A. (2016) · Nature Reviews Neurology · doi:10.1038/nrneurol.2016.113 · Cited by 928 · cited 18×
“Brain-computer interfaces (BCIs)—devices that translate a user’s neural activity into computer commands—have emerged as promising tools for helping people with LIS communicate.”
BackgroundInfluentialRestoring cortical control of functional movement in a human with quadriplegia
Bouton, C. E., Shaikhouni, A., Annetta, N. V., Bockbrader, M. A., Friedenberg, D. A., Nielson, D. M., Sharma, G., Sederberg, P. B., Glenn, B. C., Mysiw, W. J., et al. (2016) · Nature · doi:10.1038/nature17435 · Cited by 924 · cited 1×
“…et al. 2015; Pandarinath et al. 2017); and enable people with tetraplegia to control robotic arms (Aflalo et al. 2015; Collinger et al. 2013; Hochberg et al. 2012, 2006; Wodlinger et al. 2015) or their own muscles using functional electrical stimulation (Ajiboye et al. 2017; Bouton et al. 2016).”
Ajiboye, A. B., Willett, F. R., Young, D. R., Memberg, W. D., Murphy, B. A., Miller, J. P., Walter, B. L., Sweet, J. A., Hoyen, H. A., Keith, M. W., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(17)30601-3 · Cited by 862
Self-citationDecoding motor imagery from the posterior parietal cortex of a tetraplegic human
Aflalo, T., Kellis, S., Klaes, C., Lee, B., Shi, Y., Pejsa, K., Shanfield, K., Hayes-Jackson, S., Aisen, M., Heck, C., et al. (2015) · Science · doi:10.1126/science.aaa5417 · Cited by 649 · cited 2×
“2017); and enable people with tetraplegia to control robotic arms (Aflalo et al. 2015; Collinger et al. 2013; Hochberg et al. 2012, 2006; Wodlinger et al. 2015) or their own muscles using functional electrical stimulation (Ajiboye et al.”
BackgroundA brain–spine interface alleviating gait deficits after spinal cord injury in primates
Capogrosso, M., Milekovic, T., Borton, D., Wagner, F., Moraud, E. M., Mignardot, J.-B., Buse, N., Gandar, J., Barraud, Q., Xing, D., et al. (2016) · Nature · doi:10.1038/nature20118 · Cited by 635 · cited 1×
“Safety and efficacy of such devices are currently being studied in animal models (Borton et al. 2013; Capogrosso et al. 2016; Yin et al. 2014), and translation for use in people is ongoing.”
BackgroundSelf-citationA P300-based brain–computer interface for people with amyotrophic lateral sclerosis
Nijboer, F., Sellers, E. W., Mellinger, J., Jordan, M. A., Matuz, T., Furdea, A., Halder, S., Mochty, U., Krusienski, D. J., Vaughan, T. M., et al. (2008) · Clinical Neurophysiology · doi:10.1016/j.clinph.2008.03.034 · Cited by 633 · cited 4×
“…et al. 2006; Hinterberger et al. 2005; Kübler and Birbaumer 2008; Mainsah et al. 2015; Marchetti and Priftis 2015; McCane et al. 2014; Miner et al. 1998; Nijboer et al. 2008; Pires et al. 2012; Vansteensel et al. 2016) (see Table 3 for detailed list of spelling rates reported in other studies).”
BackgroundResultInfluentialFailure mode analysis of silicon-based intracortical microelectrode arrays in non-human primates
Barrese, J. C., Rao, N., Paroo, K., Triebwasser, C., Vargas-Irwin, C., Franquemont, L., & Donoghue, J. P. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/6/066014 · Cited by 600
Self-citationPandarinath, C., Nuyujukian, P., Blabe, C. H., Sorice, B. L., Saab, J., Willett, F. R., Hochberg, L. R., Shenoy, K. V., & Henderson, J. M. (2017) · eLife · doi:10.7554/elife.18554 · Cited by 566
Self-citationPatients with ALS can use sensorimotor rhythms to operate a brain-computer interface
Kübler, A., Nijboer, F., Mellinger, J., Vaughan, T. M., Pawelzik, H., Schalk, G., McFarland, D. J., Birbaumer, N., & Wolpaw, J. R. (2005) · Neurology · doi:10.1212/01.wnl.0000158616.43002.6d · Cited by 539
Wodlinger, B., Downey, J. E., Tyler-Kabara, E. C., Schwartz, A. B., Boninger, M. L., & Collinger, J. L. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/016011 · Cited by 536
Varieties of the locked-in syndrome
Bauer, G., Gerstenbrand, F., & Rumpl, E. (1979) · Journal of Neurology · doi:10.1007/bf00313105 · Cited by 504
Simeral, J. D., Kim, S.-P., Black, M. J., Donoghue, J. P., & Hochberg, L. R. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/2/025027 · Cited by 496
Self-citationKübler, A., & Birbaumer, N. (2008) · Clinical Neurophysiology · doi:10.1016/j.clinph.2008.06.019 · Cited by 441 · cited 2×
“Other studies include all studies listed in three recent reviews (Fazel-Rezai et al. 2012; Kübler and Birbaumer 2008; Marchetti and Priftis 2015).”
BackgroundClinical translation of a high-performance neural prosthesis
Gilja, V., Pandarinath, C., Blabe, C. H., Nuyujukian, P., Simeral, J. D., Sarma, A. A., Sorice, B. L., Perge, J. A., Jarosiewicz, B., Hochberg, L. R., et al. (2015) · Nature Medicine · doi:10.1038/nm.3953 · Cited by 343 · cited 4×
“Nevertheless, recent studies have demonstrated the superior performance of intracortical communication BCIs in people with tetraplegia compared with prior studies (Gilja et al. 2015; Jarosiewicz et al. 2015; Pandarinath et al. 2017).”
BackgroundMethodResultInfluentialSelf-citationJarosiewicz, B., Sarma, A. A., Bacher, D., Masse, N. Y., Simeral, J. D., Sorice, B., Oakley, E. M., Blabe, C., Pandarinath, C., Gilja, V., et al. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.aac7328 · Cited by 340
Self-citationPerge, J. A., Homer, M. L., Malik, W. Q., Cash, S., Eskandar, E., Friehs, G., Donoghue, J. P., & Hochberg, L. R. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/3/036004 · Cited by 243 · cited 2×
“It is difficult to reliably detect and isolate activity of single units within a day or from one day to the next (Dickey et al. 2009; Perge et al. 2013).”
BackgroundSelf-citationSingle-Unit Stability Using Chronically Implanted Multielectrode Arrays
Dickey, A. S., Suminski, A., Amit, Y., & Hatsopoulos, N. G. (2009) · Journal of Neurophysiology · doi:10.1152/jn.90920.2008 · Cited by 234 · cited 2×
“It is difficult to reliably detect and isolate activity of single units within a day or from one day to the next (Dickey et al. 2009; Perge et al. 2013).”
BackgroundNoninvasive brain-computer interface enables communication after brainstem stroke
Sellers, E. W., Ryan, D. B., & Hauser, C. K. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3007801 · Cited by 140
Answering questions with an electroencephalogram-based brain-computer interface
Miner, L. A., McFarland, D. J., & Wolpaw, J. R. (1998) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(98)90165-4 · Cited by 85
Towards a user-friendly brain-computer interface: initial tests in ALS and PLS patients
Bai, O., Lin, P., Huang, D., Fei, D.-Y., & Floeter, M. K. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.02.157 · Cited by 80 · cited 2×
“…reported by any EEG- or ECoG-based spellers tested on a similar population of subjects, i.e., people with ALS and people with LIS (Arya et al. 2013; Bai et al. 2010; Brunner et al. 2010; Chen et al. 2015; Fazel-Rezai et al. 2012; Hamer et al. 2002; Hedegärd et al. 2014; Hill et al. 2006;…”
Background
Cited by
Benabid, A. L., Costecalde, T., Eliseyev, A., Charvet, G., Verney, A., Karakas, S., Foerster, M., Lambert, A., Morinière, B., Abroug, N., et al. (2019) · The Lancet Neurology · doi:10.1016/s1474-4422(19)30321-7 · Cited by 404
Chiang, C.-H., Won, S. M., Orsborn, A. L., Yu, K. J., Trumpis, M., Bent, B., Wang, C., Xue, Y., Min, S., Woods, V., et al. (2020) · Science Translational Medicine · doi:10.1126/scitranslmed.aay4682 · Cited by 211
Simeral, J. D., Hosman, T., Saab, J., Flesher, S. N., Vilela, M., Franco, B., Kelemen, J. N., Brandman, D. M., Ciancibello, J. G., Rezaii, P. G., et al. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3069119 · Cited by 165
“Building on steady advances in point-and-click accuracy, speed [4], [7], [13]–[16] and consistency [4], [17]–[20], iBCI trial participants at home have achieved average on-screen point-to-select typing rates over 37 correct characters per minute maintained over days and weeks [4], [7].”
BackgroundSelf-citationNason, S. R., Vaskov, A. K., Willsey, M. S., Welle, E. J., An, H., Vu, P. P., Bullard, A. J., Nu, C. S., Kao, J. C., Shenoy, K. V., et al. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-0591-0 · Cited by 113
Self-citationThe state of clinical trials of implantable brain–computer interfaces
Patrick-Krueger, K. M., Burkhart, I., & Contreras-Vidal, J. L. (2024) · Nature Reviews Bioengineering · doi:10.1038/s44222-024-00239-5 · Cited by 125
Metadata
- Authors
- Milekovic, T., Sarma, A. A., Bacher, D., Simeral, J. D., Saab, J., Pandarinath, C., Sorice, B. L., Blabe, C., Oakley, E. M., Tringale, K. R., Eskandar, E., Cash, S. S., Henderson, J. M., Shenoy, K. V., Donoghue, J. P., & Hochberg, L. R.
- Venue
- Journal of Neurophysiology
- Publisher
- American Physiological Society
- Published
- 2018-07-01
- Volume
- 120
- Issue
- 1
- Pages
- 343-360
- ISSN
- 0022-3077 (ISSN-L)
- 1522-1598
- OpenAlex
- W2801702694
- Cited by
- 137
- References
- 27
- FWCI
- 7.05
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.