The DOI matches its Crossref record; 88 of the 88 references it cites were found in a registry or an index.
Bioelectrical Impedance Methods for Noninvasive Health Monitoring: A Review
Open accessAbstract
Under the alternating electrical excitation, biological tissues produce a complex electrical impedance which depends on tissue composition, structures, health status, and applied signal frequency, and hence the bioelectrical impedance methods can be utilized for noninvasive tissue characterization. As the impedance responses of these tissue parameters vary with frequencies of the applied signal, the impedance analysis conducted over a wide frequency band provides more information about the tissue interiors which help us to better understand the biological tissues anatomy, physiology, and pathology. Over past few decades, a number of impedance based noninvasive tissue characterization techniques such as bioelectrical impedance analysis (BIA), electrical impedance spectroscopy (EIS), electrical impedance plethysmography (IPG), impedance cardiography (ICG), and electrical impedance tomography (EIT) have been proposed and a lot of research works have been conducted on these methods for noninvasive tissue characterization and disease diagnosis. In this paper BIA, EIS, IPG, ICG, and EIT techniques and their applications in different fields have been reviewed and technical perspective of these impedance methods has been presented. The working principles, applications, merits, and demerits of these methods has been discussed in detail along with their other technical issues followed by present status and future trends.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intravenous Fluids and Acute Kidney Injury
Ding, X., Cheng, Z., & Qian, Q. (2017) · Blood Purification · doi:10.1159/000452702 · Cited by 6,827
Modern Aspects of Electrochemistry
(2002) · Modern Aspects of Electrochemistry · doi:10.1007/b114168 · Cited by 5,949
Impedance Spectroscopy: Theory, Experiment, and Applications
(2005) · Wiley eBooks · doi:10.1002/0471716243 · Cited by 5,322
Bioelectrical impedance analysis?part I: review of principles and methods
KYLE, U. (2004) · Clinical Nutrition · doi:10.1016/j.clnu.2004.06.004 · Cited by 3,200 · cited 6×
“ECW can be found related to extracellular mass (ECM) and ICW to body cell mass (BCM).”
BackgroundMethodInfluentialBioelectrical impedance analysis—part II: utilization in clinical practice
Kyle, U. G., Bosaeus, I., De Lorenzo, A. D., Deurenberg, P., Elia, M., Manuel Gómez, J., Lilienthal Heitmann, B., Kent-Smith, L., Melchior, J.-C., Pirlich, M., et al. (2004) · Clinical Nutrition · doi:10.1016/j.clnu.2004.09.012 · Cited by 2,350
ENCYCLOPEDIA OF Surface and Colloid Science
Somasundaran, P., & Hubbard, A. T. (2021) · CRC Press eBooks · doi:10.1201/9780367813437 · Cited by 2,104
Assessment of fat-free mass using bioelectrical impedance measurements of the human body
Lukaski, H., Johnson, P., Bolonchuk, W., & Lykken, G. (1985) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/41.4.810 · Cited by 1,896
Medical Instrumentation-Application and Design
Webster, J. G. (1978) · Journal of Clinical Engineering · doi:10.1097/00004669-197807000-00017 · Cited by 1,847
BioelectromagnetismPrinciples and Applications of Bioelectric and Biomagnetic Fields
Malmivuo, J., & Plonsey, R. (1995) · doi:10.1093/acprof:oso/9780195058239.001.0001 · Cited by 1,834
Electrical Properties of Tissue and Cell Suspensions
Schwan, H. P. (1957) · Advances in Biological and Medical Physics · doi:10.1016/b978-1-4832-3111-2.50008-0 · Cited by 1,620
Electrochemical Impedance Spectroscopy
(2016) · Encyclopedia of Membranes · doi:10.1007/978-3-662-44324-8_100089 · Cited by 1,580
Electrochemical Impedance Spectroscopy
Chang, B.-Y., & Park, S.-M. (2010) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.012809.102211 · Cited by 1,248
Electrochemical Impedance Spectroscopy and its Applications
Lasia, A. (2005) · Modern Aspects of Electrochemistry · doi:10.1007/0-306-46916-2_2 · Cited by 1,214
Macdonald, J. R. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368532 · Cited by 1,166
Electrical Impedance Tomography
Holder, D. S., & Aristovich, K. Y. (2004) · CRC Press eBooks · doi:10.1201/9781003026242-9 · Cited by 815
Barber, D. C., & Brown, B. H. (1984) · Journal of Physics E: Scientific Instruments · doi:10.1088/0022-3735/17/9/002 · Cited by 726
Bioelectrical Impedance Analysis: A Review of Principles and Applications
Kushner, R. F. (1992) · Journal of the American College of Nutrition · doi:10.1080/07315724.1992.12098245 · Cited by 625
Comparing Reconstruction Algorithms for Electrical Impedance Tomography
Yorkey, T. J., Webster, J. G., & Tompkins, W. J. (1987) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1987.326032 · Cited by 596
Electrical impedance tomography (EIT): a review
Brown, B. (2003) · Journal of Medical Engineering & Technology · doi:10.1080/0309190021000059687 · Cited by 556
Advances in Biological and Medical Physics
Blout, E. R., Grabar, P., Kirkpatrick, P., Mayneord, W. V., Pattee, H. H., Pollard, E., Pressman, D., Sinclair, W. K., Solomon, A. K., Lawrence, J. H., et al. (1954) · Physics Today · doi:10.1063/1.3061723 · Cited by 541
Correlation of whole-body impedance with total body water volume.
Hoffer, E. C., Meador, C. K., & Simpson, D. C. (1969) · Journal of Applied Physiology · doi:10.1152/jappl.1969.27.4.531 · Cited by 525
NYBOER, J., Kreider, M. M., & Hannapel, L. (1950) · Circulation · doi:10.1161/01.cir.2.6.811 · Cited by 490
Kemna, A., Vanderborght, J., Kulessa, B., et al. (2002) · Journal of Hydrology · doi:10.1016/s0022-1694(02)00145-2 · Cited by 460
EIT reconstruction algorithms: pitfalls, challenges and recent developments
Lionheart, W. R. B. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/1/021 · Cited by 447
BIOIMPEDANCE TOMOGRAPHY (ELECTRICAL IMPEDANCE TOMOGRAPHY)
Bayford, R. (2006) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.8.061505.095716 · Cited by 405
Electrical resistance tomography for process applications
Dickin, F. J., & Wang, M. (1996) · Measurement Science and Technology · doi:10.1088/0957-0233/7/3/005 · Cited by 401
EIT reconstruction algorithms: pitfalls, challenges and recent developmentsPreprint
Lionheart, W. R. B. (2004) · Cited by 386
Three-dimensional electrical impedance tomography
Metherall, P., Barber, D. C., Smallwood, R. H., & Brown, B. H. (1996) · Nature · doi:10.1038/380509a0 · Cited by 386
Sun, G., French, C. R., Martin, G. R., Younghusband, B., Green, R. C., Xie, Y.-G., Mathews, M., Barron, J. R., Fitzpatrick, D. G., Gulliver, W., et al. (2005) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/81.1.74 · Cited by 377
Electric Properties of Tissues
Miklavčič, D., Pavšelj, N., & Hart, F. X. (2006) · Wiley Encyclopedia of Biomedical Engineering · doi:10.1002/9780471740360.ebs0403 · Cited by 376
Why bioelectrical impedance analysis should be used for estimating adiposity.
Houtkooper, L., Lohman, T., Going, S., & Howell, W. (1996) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/64.3.436s · Cited by 361
Dual-Energy (Spectral) CT: Applications in Abdominal Imaging
Silva, A. C., Morse, B. G., Hara, A. K., Paden, R. G., Hongo, N., & Pavlicek, W. (2011) · RadioGraphics · doi:10.1148/rg.314105159 · Cited by 351
Electrical impedance spectroscopy study of biological tissues
Dean, D. A., Ramanathan, T., Machado, D., & Sundararajan, R. (2008) · Journal of Electrostatics · doi:10.1016/j.elstat.2007.11.005 · Cited by 299
Bosy-Westphal, A., Schautz, B., Later, W., Kehayias, J. J., Gallagher, D., & Müller, M. J. (2013) · European Journal of Clinical Nutrition · doi:10.1038/ejcn.2012.160 · Cited by 296
FDG PET, PET/CT, and Breast Cancer Imaging
Rosen, E. L., Eubank, W. B., & Mankoff, D. A. (2007) · RadioGraphics · doi:10.1148/rg.27si075517 · Cited by 265
Electrical Resistance Tomography imaging of concrete
Karhunen, K., Seppänen, A., Lehikoinen, A., Monteiro, P. J. M., & Kaipio, J. P. (2010) · Cement and Concrete Research · doi:10.1016/j.cemconres.2009.08.023 · Cited by 249
Abbot, D. S., Palmer, P. I., Martin, R. V., Chance, K. V., Jacob, D. J., & Guenther, A. (2003) · Geophysical Research Letters · doi:10.1029/2003gl017336 · Cited by 239
Multifrequency bioelectrical impedance estimates the distribution of body water
Cha, K., Chertow, G. M., Gonzalez, J., Lazarus, J. M., & Wilmore, D. W. (1995) · Journal of Applied Physiology · doi:10.1152/jappl.1995.79.4.1316 · Cited by 211
Methods of complex impedance measurements in biologic tissue.
Ackmann, J. J., & Seitz, M. A. (1984) · PubMed · Cited by 203
Decomposition of Human Remains
Janaway, R. C., Percival, S. L., & Wilson, A. S. (2009) · Microbiology and Aging · doi:10.1007/978-1-59745-327-1_14 · Cited by 196
Analysis of electrochemical impedance spectroscopy in proton exchange membrane fuel cells
Gomadam, P. M., & Weidner, J. W. (2005) · International Journal of Energy Research · doi:10.1002/er.1144 · Cited by 192
Electrical impedance tomography
Costa, E. L., Lima, R. G., & Amato, M. B. (2009) · Current Opinion in Critical Care · doi:10.1097/mcc.0b013e3283220e8c · Cited by 189
Segmental body composition assessed by bioelectrical impedance analysis and DEXA in humans
Bracco, D., Thiébaud, D., Chioléro, R. L., Landry, M., Burckhardt, P., & Schutz, Y. (1996) · Journal of Applied Physiology · doi:10.1152/jappl.1996.81.6.2580 · Cited by 159
Computed Tomography for Imaging the Breast
Boone, J. M., Kwan, A. L. C., Yang, K., et al. (2006) · Journal of Mammary Gland Biology and Neoplasia · doi:10.1007/s10911-006-9017-1 · Cited by 150
Bioelectrical Impedance Analysis
Chumlea, W. C., & Sun, S. S. (2005) · Human Kinetics eBooks · doi:10.5040/9781492596950.ch-006 · Cited by 149
Lobo, D. N., Stanga, Z. G., Simpson, J. A., Anderson, J. A. D., Rowlands, B. J., & Allison, S. P. (2001) · Clinical Science · doi:10.1042/cs20000316 · Cited by 147
Romsauerova, A., McEwan, A. L., Lior Horesh, C., Yerworth, R., Bayford, R. H., & Holder, D. S. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/5/s13 · Cited by 141
Complex bioelectric impedance measurement system for the frequency range from 5 Hz to 1 MHz
Ackmann, J. J. (1993) · Annals of Biomedical Engineering · doi:10.1007/bf02367609 · Cited by 130
The technique of impedance cardiography
Woltjer, H. H., Bogaard, H. J., & VRIES, P. M. J. M. D. (1997) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a015464 · Cited by 123
Gupta, M., Schriger, D. L., Hiatt, J. R., Cryer, H. G., Tillou, A., Hoffman, J. R., & Baraff, L. J. (2011) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2011.06.003 · Cited by 123
Chambers, J. E., Wilkinson, P. B., Wardrop, D. R., Hameed, A., Hill, I. A., Jeffrey, C. A., Loke, M. H., Meldrum, P., Kuras, O., Cave, M. R., et al. (2012) · Geomorphology · doi:10.1016/j.geomorph.2012.03.034 · Cited by 115
Parrinello, G., Paterna, S., Pasquale, P. D., Torres, D., Fatta, A., Mezzero, M., Scaglione, R., & Licata, G. (2008) · Journal of Cardiac Failure · doi:10.1016/j.cardfail.2008.04.005 · Cited by 101
Bioelectrical Impedance Analysis What Does It Measure?
Schoeller, D. A. (2000) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.2000.tb06441.x · Cited by 96
Sun, T., Gawad, S., Bernabini, C., et al. (2007) · Measurement Science and Technology · doi:10.1088/0957-0233/18/9/015 · Cited by 89
Sparse representation-based MRI super-resolution reconstruction
Wang, Y., Qiao, J., Li, J., Fu, P., Chu, S., & Roddick, J. F. (2013) · Measurement · doi:10.1016/j.measurement.2013.10.026 · Cited by 87
Linear filtering of 2-D wavelet coefficients for denoising ultrasound medical images
Andria, G., Attivissimo, F., Cavone, G., et al. (2012) · Measurement · doi:10.1016/j.measurement.2012.04.005 · Cited by 82
Jakicic, J., Wing, R., & Lang, W. (1998) · International Journal of Obesity · doi:10.1038/sj.ijo.0800576 · Cited by 73 · cited 2×
“Electrical impedance based noninvasive tissue characterizing techniques like bioelectrical impedance analysis (BIA) [7–21], electrical impedance spectroscopy (EIS) [22–32], electrical impedance plethysmography (IPG) [33, 34], impedance cardiography (ICG) [35–37], and electrical impedance tomography (EIT) [38, 39] are…”
BackgroundMethodMagnetic resonance imaging of breast cancer: Clinical indications and breast MRI reporting system
Ikeda, D. M., Baker, D. R., & Daniel, B. L. (2000) · Journal of Magnetic Resonance Imaging · doi:10.1002/1522-2586(200012)12:6<975::aid-jmri24>3.0.co;2-y · Cited by 67
Bera, T. K., & Nagaraju, J. (2012) · Measurement · doi:10.1016/j.measurement.2012.01.002 · Cited by 65
Self-citationMager, J. R., Sibley, S. D., Beckman, T. R., Kellogg, T. A., & Earthman, C. P. (2008) · Clinical Nutrition · doi:10.1016/j.clnu.2008.06.007 · Cited by 60
Automated people-counting by using low-resolution infrared and visual cameras
Amin, I. J., Taylor, A. J., Junejo, F., Al‐Habaibeh, A., & Parkin, R. M. (2007) · Measurement · doi:10.1016/j.measurement.2007.02.010 · Cited by 56
Dedicated Breast Computed Tomography: The Optimal Cross-Sectional Imaging Solution?
Lindfors, K. K., Boone, J. M., Newell, M. S., & D’Orsi, C. J. (2010) · Radiologic Clinics of North America · doi:10.1016/j.rcl.2010.06.001 · Cited by 54
Bera, T. K., & Nagaraju, J. (2010) · Measurement · doi:10.1016/j.measurement.2010.11.015 · Cited by 53
Self-citationDanford, L. C., Schoeller, D. A., & Kushner, R. F. (1992) · Annals of Human Biology · doi:10.1080/03014469200002422 · Cited by 53
Bera, T. K., Biswas, S. K., Rajan, K., & Nagaraju, J. (2011) · Journal of Electrical Bioimpedance · doi:10.5617/jeb.158 · Cited by 51
Self-citationElectrical Impedance Spectroscopy Sensing for Industrial Processes
Nahvi, M., & Hoyle, B. (2009) · IEEE Sensors Journal · doi:10.1109/jsen.2009.2030979 · Cited by 51
Evaluating ion diffusivity of cracked cement paste using electrical impedance spectroscopy
Akhavan, A., & Rajabipour, F. (2012) · Materials and Structures · doi:10.1617/s11527-012-9927-x · Cited by 50
Label-free analysis of water-polluting parasite by electrochemical impedance spectroscopy
Houssin, T., Follet, J., Follet, A., Dei‐Cas, E., & Senez, V. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.09.039 · Cited by 49
Yi, C. A., Lee, K. S., Lee, H. Y., Kim, S., Kwon, O. J., Kim, H., Choi, J. Y., Kim, B., Hwang, H. S., & Shim, Y. M. (2013) · Cancer · doi:10.1002/cncr.28000 · Cited by 48
Bera, T. K., & Nagaraju, J. (2009) · Conference proceedings - IEEE Instrumentation/Measurement Technology Conference · doi:10.1109/imtc.2009.5168503 · Cited by 46
Self-citationA novel combination method of electrical impedance tomography inverse problem for brain imaging
Li, Y., Rao, L., He, R., Xu, G., Wu, Q. F., Yan, W., Dong, G., & Yang, Q. (2005) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2005.846506 · Cited by 44
Computed tomographymeasurements on wood
Davis, J., & Wells, P. (1992) · Industrial Metrology · doi:10.1016/0921-5956(92)80004-d · Cited by 41
Rahman, M. Z. U., Karthik, G. V. S., Fathima, S. Y., & Lay-Ekuakille, A. (2013) · Measurement · doi:10.1016/j.measurement.2013.07.009 · Cited by 37
Capacity Measurements of Li-Ion Batteries using AC Impedance Spectroscopy
Jespersen, J., Tønnesen, A. E., Nørregaard, K., Overgaard, L., & Elefsen, F. (2009) · World Electric Vehicle Journal · doi:10.3390/wevj3010127 · Cited by 33
Electrical Impedance Spectroscopy for Electro-Mechanical Characterization of Conductive Fabrics
Bera, T. K., Mohamadou, Y., Lee, K., Wi, H., Oh, T. I., Woo, E. J., Soleimani, M., & Seo, J. K. (2014) · Sensors · doi:10.3390/s140609738 · Cited by 32
Self-citationNoninvasive Electromagnetic Methods for Brain Monitoring: A Technical Review
Bera, T. K. (2014) · Intelligent systems reference library · doi:10.1007/978-3-319-10978-7_3 · Cited by 30
Self-citationElectrical Impedance Tomography (EIT): A Harmless Medical Imaging Modality
Bera, T. K., & Nagaraju, J. (2013) · Advances in computational intelligence and robotics book series · doi:10.4018/978-1-4666-4558-5.ch013 · Cited by 24
Self-citationRutherford, W. J., Diemer, G. A., & Scott, E. D. (2011) · Cited by 22
The use of three-dimensional ultrasound imaging in breast biopsy and prostate therapy
Fenster, A., Surry, K. J. M., Smith, W. L., & Downey, D. B. (2004) · Measurement · doi:10.1016/j.measurement.2004.09.013 · Cited by 22
Bera, T. K., & Nagaraju, J. (2013) · Measurement · doi:10.1016/j.measurement.2013.08.064 · Cited by 19
Self-citationNew analytical applications of gold nanoparticles
Kurniawan, F. (2009) · University of Regensburg Publication Server (University of Regensburg) · doi:10.5283/epub.12113 · Cited by 17
Bio-electrical impedance spectroscopy: Alternatives for the conventional hand-to-foot measurements
Cox-Reijven, P. L. M., van Kreel, B., & Soeters, P. B. (2002) · Clinical Nutrition · doi:10.1054/clnu.2001.0521 · Cited by 17
Gold electrode sensors for electrical impedance tomography (EIT) studies
Bera, T. K., & Nagaraju, J. (2011) · IEEE Sensors Applications Symposium (SAS) · doi:10.1109/sas.2011.5739810 · Cited by 15
Self-citationHu, H., & Kato, Y. (1995) · Endocrine Journal · doi:10.1507/endocrj.42.545 · Cited by 13
Common Ground Method of Current Injection in Electrical Impedance Tomography
Bera, T. K., & Nagaraju, J. (2012) · Communications in computer and information science · doi:10.1007/978-3-642-29216-3_63 · Cited by 11
Self-citationMicrofabricated Thin Film Impedance Sensor & AC Impedance Measurements
Yu, J., & Liu, C.-C. (2010) · Sensors · doi:10.3390/s100605847 · Cited by 10
Imperiale, C., & Impériale, A. (2005) · Measurement · doi:10.1016/j.measurement.2004.11.013 · Cited by 7
Porter, J. M., Swain, I., & Shakespeare, P. G. (1987) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(87)90086-0 · Cited by 4
Cited by
Wearable sensors: modalities, challenges, and prospects
Heikenfeld, J., Jajack, A., Rogers, J., Gutruf, P., Tian, L., Pan, T., Li, R., Khine, M., Kim, J., Wang, J., et al. (2018) · Lab on a Chip · doi:10.1039/c7lc00914c · Cited by 1,434
Electrical impedance spectroscopy (EIS) for biological analysis and food characterization: a review
Grossi, M., & Riccò, B. (2017) · Journal of Sensors and Sensor Systems · doi:10.5194/jsss-6-303-2017 · Cited by 394
Son, J. W., Han, B., Bennett, J. P., Heymsfield, S., & Lim, S. (2025) · Obesity Reviews · doi:10.1111/obr.13844 · Cited by 74
Yu, P., Hsu, C., Lee, W., Liang, C., Chou, M., Lin, M., Hsiao, F., Peng, L., & Chen, L. (2022) · Journal of Cachexia, Sarcopenia and Muscle · doi:10.1002/jcsm.12877 · Cited by 70
Flexible bioimpedance spectroscopy system for wound care monitoring
Mc Caffrey, C., Flak, J., Kiri, K., & Pursula, P. (2019) · 2019 IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2019.8919095 · Cited by 14
Metadata
- Authors
- Bera, T. K.
- Venue
- Journal of Medical Engineering
- Publisher
- Hindawi Limited
- Published
- 2014-06-17
- Volume
- 2014
- Pages
- 1-28
- ISSN
- 2314-5129 (ISSN-L)
- 2314-5137
- OpenAlex
- W2056046734
- Cited by
- 407
- References
- 88
- FWCI
- 8.67
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.