Long-Term Clinical Course of Patients After Termination of Ventricular Tachyarrhythmia by an Implanted Defibrillator
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
Background— The implanted cardioverter defibrillator (ICD) improves survival in high-risk cardiac patients. This analysis from the MADIT-II trial database examines the long-term clinical course and subsequent mortality risk of patients after termination of life-threatening ventricular tachyarrhythmias by an ICD. Methods and Results— Life-table survival analysis was performed, and proportional hazards regression analysis was used to evaluate the contribution of baseline clinical factors and time-dependent defibrillator therapy to mortality during long-term follow-up. Of 720 patients with an ICD (average follow-up 21 months), 169 patients received 701 antiarrhythmic device therapies for ventricular tachyarrhythmias. Few baseline characteristics distinguished patients who received appropriate ICD therapy for their first ventricular tachyarrhythmic episode. The probability of survival for at least 1 year after first therapy for ventricular tachycardia (VT) or ventricular fibrillation (VF) was 80%. The hazard ratios for the risk of death due to any cause in those who survived appropriate therapy for termination of VT and VF were 3.4 ( P <0.001) and 3.3 ( P =0.01), respectively, compared with those who survived without receiving ICD therapy, with a high frequency of heart failure and late nonsudden cardiac death after first successful ICD therapy for VF. Conclusions— Successful appropriate therapy by an ICD for VT or VF is associated with 80% survival at 1 year after arrhythmia termination. These patients are at increased risk for heart failure and nonsudden cardiac death after device termination of VT or VF and should receive special attention for the prevention and management of progressive left ventricular dysfunction during long-term follow-up.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonparametric Estimation from Incomplete Observations
Kaplan, E. L., & Meier, P. (1992) · Springer Series in Statistics · doi:10.1007/978-1-4612-4380-9_25 · Cited by 45,181
Regression Models and Life-Tables
Cox, D. R. (1972) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1972.tb00899.x · Cited by 39,793
Nonparametric Estimation from Incomplete Observations
Kaplan, E. L., & Meier, P. (1958) · Journal of the American Statistical Association · doi:10.1080/01621459.1958.10501452 · Cited by 39,158
Moss, A. J., Zareba, W., Hall, W. J., Klein, H., Wilber, D. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Brown, M. W., & Andrews, M. L. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013474 · Cited by 6,902
Self-citationMoss, A. J., Hall, W. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Klein, H., Levine, J. H., Saksena, S., Waldo, A. L., Wilber, D., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199612263352601 · Cited by 4,165
Self-citation(1997) · New England Journal of Medicine · doi:10.1056/nejm199711273372202 · Cited by 3,232
A Randomized Study of the Prevention of Sudden Death in Patients with Coronary Artery Disease
Buxton, A. E., Lee, K. L., Fisher, J. D., Josephson, M. E., Prystowsky, E. N., & Hafley, G. (1999) · New England Journal of Medicine · doi:10.1056/nejm199912163412503 · Cited by 2,489
The DAVID Trial Investigators* (2002) · JAMA · doi:10.1001/jama.288.24.3115 · Cited by 2,056
Connolly, S. J., Gent, M., Roberts, R. S., Dorian, P., Roy, D., Sheldon, R. S., Mitchell, L. B., Green, M. S., Klein, G. J., & O’Brien, B. (2000) · Circulation · doi:10.1161/01.cir.101.11.1297 · Cited by 1,607
Clinical classification of cardiac deaths.
Hinkle, L. E., & Thaler, H. T. (1982) · Circulation · doi:10.1161/01.cir.65.3.457 · Cited by 638
Cited by
The Effect of Cardiac Resynchronization on Morbidity and Mortality in Heart Failure
Cleland, J. G. F., Daubert, J.-C., Erdmann, E., Freemantle, N., Gras, D., Kappenberger, L., & Tavazzi, L. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa050496 · Cited by 6,276
Self-citationZeppenfeld, K., Tfelt-Hansen, J., de Riva, M., Winkel, B. G., Behr, E. R., Blom, N. A., Charron, P., Corrado, D., Dagres, N., de Chillou, C., et al. (2022) · European Heart Journal · doi:10.1093/eurheartj/ehac262 · Cited by 3,140
Prognostic Importance of Defibrillator Shocks in Patients with Heart Failure
Poole, J. E., Johnson, G. W., Hellkamp, A. S., Anderson, J., Callans, D. J., Raitt, M. H., Reddy, R. K., Marchlinski, F. E., Yee, R., Guarnieri, T., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa071098 · Cited by 1,462
Prophylactic Catheter Ablation for the Prevention of Defibrillator Therapy
Reddy, V. Y., Reynolds, M. R., Neuzil, P., Richardson, A. W., Taborsky, M., Jongnarangsin, K., Kralovec, S., Sediva, L., Ruskin, J. N., & Josephson, M. E. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa065457 · Cited by 959
Inappropriate Implantable Cardioverter-Defibrillator Shocks in MADIT II
Daubert, J. P., Zareba, W., Cannom, D. S., McNitt, S., Rosero, S. Z., Wang, P., Schuger, C., Steinberg, J. S., Higgins, S. L., Wilber, D. J., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.09.073 · Cited by 813
Self-citationKuck, K.-H., Schaumann, A., Eckardt, L., Willems, S., Ventura, R., Delacrétaz, E., Pitschner, H.-F., Kautzner, J., Schumacher, B., & Hansen, P. S. (2010) · The Lancet · doi:10.1016/s0140-6736(09)61755-4 · Cited by 799
EHRA/HRS Expert Consensus on Catheter Ablation of Ventricular Arrhythmias
Aliot, E. M., Stevenson, W. G., Almendral-Garrote, J. M., Bogun, F., Calkins, C. H., Delacretaz, E., Della Bella, P., Hindricks, G., Jaïs, P., Josephson, M. E., et al. (2009) · Heart Rhythm · doi:10.1016/j.hrthm.2009.04.030 · Cited by 770
Hindricks, G., Taborsky, M., Glikson, M., Heinrich, U., Schumacher, B., Katz, A., Brachmann, J., Lewalter, T., Goette, A., Block, M., et al. (2014) · The Lancet · doi:10.1016/s0140-6736(14)61176-4 · Cited by 740
Stevenson, W. G., Wilber, D. J., Natale, A., Jackman, W. M., Marchlinski, F. E., Talbert, T., Gonzalez, M. D., Worley, S. J., Daoud, E. G., Hwang, C., et al. (2008) · Circulation · doi:10.1161/circulationaha.108.788604 · Cited by 732
Defibrillator implantation early after myocardial infarction
Steinbeck, G., Andresen, D., Seidl, K., Brachmann, J., Hoffmann, E., Wojciechowski, D., Kornacewicz-Jach, Z., Sredniawa, B., Lupkovics, G., Hofgärtner, F., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0901889 · Cited by 690
Saxon, L. A., Hayes, D. L., Gilliam, F. R., Heidenreich, P. A., Day, J., Seth, M., Meyer, T. E., Jones, P. W., & Boehmer, J. P. (2010) · Circulation · doi:10.1161/circulationaha.110.960633 · Cited by 515
Roes, S. D., Borleffs, C. J. W., van der Geest, R. J., Westenberg, J. J. M., Marsan, N. A., Kaandorp, T. A. M., Reiber, J. H. C., Zeppenfeld, K., Lamb, H. J., de Roos, A., et al. (2009) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.108.826529 · Cited by 461
Aliot, E. M., Stevenson, W. G., Almendral-Garrote, J. M., Bogun, F., Calkins, C. H., Delacretaz, E., Bella, P. D., Hindricks, G., Jais, P., Josephson, M. E., et al. (2009) · Europace · doi:10.1093/europace/eup098 · Cited by 416
Fallavollita, J. A., Heavey, B. M., Luisi, A. J., Michalek, S. M., Baldwa, S., Mashtare, T. L., Hutson, A. D., deKemp, R. A., Haka, M. S., Sajjad, M., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.07.096 · Cited by 399
Boogers, M. J., Borleffs, C. J. W., Henneman, M. M., van Bommel, R. J., van Ramshorst, J., Boersma, E., Dibbets-Schneider, P., Stokkel, M. P., van der Wall, E. E., Schalij, M. J., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.12.066 · Cited by 368
Tung, R., Zimetbaum, P., & Josephson, M. E. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.05.058 · Cited by 362
Sweeney, M. O., Sherfesee, L., DeGroot, P. J., Wathen, M. S., & Wilkoff, B. L. (2010) · Heart Rhythm · doi:10.1016/j.hrthm.2009.11.027 · Cited by 345
EHRA/HRS/APHRS expert consensus on ventricular arrhythmias
Pedersen, C. T., Kay, G. N., Kalman, J., Borggrefe, M., Della-Bella, P., Dickfeld, T., Dorian, P., Huikuri, H., Kim, Y.-H., Knight, B., et al. (2014) · Europace · doi:10.1093/europace/euu194 · Cited by 327
Maron, M. S., Rowin, E. J., Wessler, B. S., Mooney, P. J., Fatima, A., Patel, P., Koethe, B. C., Romashko, M., Link, M. S., & Maron, B. J. (2019) · JAMA Cardiology · doi:10.1001/jamacardio.2019.1391 · Cited by 325
Ellenbogen, K. A., Levine, J. H., Berger, R. D., Daubert, J. P., Winters, S. L., Greenstein, E., Shalaby, A., Schaechter, A., Subacius, H., & Kadish, A. (2006) · Circulation · doi:10.1161/circulationaha.105.561571 · Cited by 299
Self-citationCatheter Ablation for Ventricular Tachycardia
Stevenson, W. G., & Soejima, K. (2007) · Circulation · doi:10.1161/circulationaha.106.655720 · Cited by 299
Maron, B. J. (2010) · Circulation · doi:10.1161/circulationaha.109.878579 · Cited by 296
Saxon, L. A., Bristow, M. R., Boehmer, J., Krueger, S., Kass, D. A., De Marco, T., Carson, P., DiCarlo, L., Feldman, A. M., Galle, E., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.642892 · Cited by 290
EHRA/HRS/APHRS expert consensus on ventricular arrhythmias
Pedersen, C. T., Kay, G. N., Kalman, J., Borggrefe, M., Della-Bella, P., Dickfeld, T., Dorian, P., Huikuri, H., Kim, Y.-H., Knight, B., et al. (2014) · Heart Rhythm · doi:10.1016/j.hrthm.2014.07.024 · Cited by 288
The Effect of Cardiac Resynchronization on Morbidity and Mortality in Heart Failure
Cleland, J. G. F., Daubert, J. C., & Erdmann, E. (2005) · ACC Current Journal Review · doi:10.1016/j.accreview.2005.05.046 · Cited by 227
Self-citationGermano, J. J., Reynolds, M., Essebag, V., & Josephson, M. E. (2006) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2005.11.048 · Cited by 221
Gao, P., Yee, R., Gula, L., Krahn, A. D., Skanes, A., Leong-Sit, P., Klein, G. J., Stirrat, J., Fine, N., Pallaveshi, L., et al. (2012) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.111.971549 · Cited by 212
“However, post hoc analysis of the MADIT II study identified that only 35% of patients receiving ICDs subsequently received appropriate therapy at 3 years.(7) Furthermore, many patients with resuscitated SCD are found to have an LVEF above current ICD implantation guidelines thresholds.”
MethodDella Bella, P., Baratto, F., Vergara, P., Bertocchi, P., Santamaria, M., Notarstefano, P., Calò, L., Orsida, D., Tomasi, L., Piacenti, M., et al. (2022) · Circulation · doi:10.1161/circulationaha.122.059598 · Cited by 204
JCS/JHRS 2019 Guideline on Non-Pharmacotherapy of Cardiac Arrhythmias
Nogami, A., Kurita, T., Abe, H., Ando, K., Ishikawa, T., Imai, K., Usui, A., Okishige, K., Kusano, K., Kumagai, K., et al. (2021) · Circulation Journal · doi:10.1253/circj.cj-20-0637 · Cited by 200
Daubert, J. P., Zareba, W., Hall, W. J., Schuger, C., Corsello, A., Leon, A. R., Andrews, M. L., McNitt, S., Huang, D. T., & Moss, A. J. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.08.049 · Cited by 191
Self-citationWillems, S., Tilz, R. R., Steven, D., Kääb, S., Wegscheider, K., Gellér, L., Meyer, C., Heeger, C.-H., Metzner, A., Sinner, M. F., et al. (2020) · Circulation · doi:10.1161/circulationaha.119.043400 · Cited by 190
“Secondary outcome measures were (1) sustained VT or ventricular fibrillation (including episodes not detected by the ICD, eg, because of an arrhythmia cycle length outside the detection window); (2) appropriate ICD therapy; (3) inappropriate ICD therapy; (4) death resulting from any cause; (5) death resulting from car…”
MethodSubstrate Ablation vs Antiarrhythmic Drug Therapy for Symptomatic Ventricular Tachycardia
Arenal, Á., Ávila, P., Jiménez-Candil, J., Tercedor, L., Calvo, D., Arribas, F., Fernández-Portales, J., Merino, J. L., Hernández-Madrid, A., Fernández-Avilés, F. J., et al. (2022) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2022.01.050 · Cited by 185
Vyas, A. K., Guo, H., Moss, A. J., Olshansky, B., McNitt, S. A., Hall, W. J., Zareba, W., Steinberg, J. S., Fischer, A., Ruskin, J., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.09.053 · Cited by 176
“Details of the CD devices, their programming, and their interrogation were ecently reported (9).”
BackgroundSelf-citationArrhythmias in Patients ≥80 Years of Age
Curtis, A. B., Karki, R., Hattoum, A., & Sharma, U. C. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.03.019 · Cited by 169
Singh, J. P., Hall, W. J., McNitt, S., Wang, H., Daubert, J. P., Zareba, W., Ruskin, J. N., & Moss, A. J. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.05.088 · Cited by 168
Self-citationVentricular Tachycardia Ablation: Evolution of Patients and Procedures Over 8 Years
Sacher, F., Tedrow, U. B., Field, M. E., Raymond, J.-M., Koplan, B. A., Epstein, L. M., & Stevenson, W. G. (2008) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.108.769471 · Cited by 166
JCS/JHRS 2019 guideline on non‐pharmacotherapy of cardiac arrhythmias
Nogami, A., Kurita, T., Abe, H., Ando, K., Ishikawa, T., Imai, K., Usui, A., Okishige, K., Kusano, K., Kumagai, K., et al. (2021) · Journal of Arrhythmia · doi:10.1002/joa3.12491 · Cited by 164
Nielsen, J. C., Lin, Y.-J., de Oliveira Figueiredo, M. J., Sepehri Shamloo, A., Alfie, A., Boveda, S., Dagres, N., Di Toro, D., Eckhardt, L. L., Ellenbogen, K., et al. (2020) · EP Europace · doi:10.1093/europace/euaa065 · Cited by 98
Remote monitoring of implantable devices: should we continue to ignore it?
Bertini, M., Marcantoni, L., Toselli, T., & Ferrari, R. (2016) · International Journal of Cardiology · doi:10.1016/j.ijcard.2015.09.033 · Cited by 28
Metadata
- Authors
- Moss, A. J., Greenberg, H., Case, R. B., Zareba, W., Hall, W. J., Brown, M. W., Daubert, J. P., McNitt, S., Andrews, M. L., & Elkin, A. D.
- Venue
- Circulation
- Published
- 2004-12-21
- Volume
- 110
- Issue
- 25
- Pages
- 3760-3765
- ISSN
- 0009-7322 (ISSN-L)
- 1524-4539
- OpenAlex
- W2169108049
- Cited by
- 597
- References
- 14
- FWCI
- 10.33
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.