Clinical Utility of Aortic Pulses and Pressures Calculated From Applanated Radial-Artery Pulses
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
Brachial artery cuff blood pressures are but approximations of central aortic pressures. The actual pressures against which the left ventricle must pump would be useful clinical information if obtained noninvasively. Our aim was to determine the clinical utility of aortic pulses and pressures calculated from noninvasively obtained radial-artery pulses. Radial-arterial pulses were recorded by applanation and calibrated with arm/cuff oscillometric pressures. Aortic pulses and pressures were calculated from the radial pulses by Fourier analysis and transfer functions. These calculated aortic pulses were compared with directly recorded aortic pulses by a transducer-tip catheter in a series of 50 patients undergoing cardiac catheterization. The correlation coefficient ( r ) of the measured versus the calculated aortic systolic blood pressure was +0.89, but the scatter was large (standard deviation of the differences=±11.3 mm Hg). The pulse pressure correlations were less good ( r =+0.79) and also had a large scatter (±13.6 mm Hg). The average calculated pulse pressure was 11.5 mm Hg lower than the measured value because the cuff diastolic blood pressures, used to calibrate the radial pulses, were systematically higher than those in the aorta (8.9 mm Hg). Multivariable analysis incorporating height, age, heart rate, and ejection fraction as additional, independent variables eliminated mean differences between the new “predicted” and measured pressures, significantly improved correlation coefficients, and reduced the scatter. However, the improvements were small. The inaccuracy of the oscillometric cuff method for measuring arm blood pressure appears to be the limiting factor in the prediction of clinically useful, noninvasive aortic pressures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
McDonald's blood flow in arteries; theoretical, experimental and clinical principles
(1992) · General Pharmacology: The Vascular System · doi:10.1016/0306-3623(92)90079-y · Cited by 2,388
Chen, C.-H., Nevo, E., Fetics, B., Pak, P. H., Yin, F. C. P., Maughan, W. L., & Kass, D. A. (1997) · Circulation · doi:10.1161/01.cir.95.7.1827 · Cited by 1,307
Pauca, A. L., O’Rourke, M. F., & Kon, N. D. (2001) · Hypertension · doi:10.1161/hy1001.096106 · Cited by 1,179
KARAMANOGLU, M., O'ROURKE, M. F., AVOLIO, A. P., & KELLY, R. P. (1993) · European Heart Journal · doi:10.1093/eurheartj/14.2.160 · Cited by 873
O??Brien, E., Petrie, J., Littler, W., de Swiet, M., Padfield, P. L., O??Malley, K., Jamieson, M., Altman, D., Bland, M., & Atkins, N. (1990) · Journal of Hypertension · doi:10.1097/00004872-199007000-00004 · Cited by 772
O'Rourke, M. F., Pauca, A., & Jiang, X. (2001) · British Journal of Clinical Pharmacology · doi:10.1046/j.0306-5251.2001.01400.x · Cited by 640
Borow, K. M., & Newburger, J. W. (1982) · American Heart Journal · doi:10.1016/0002-8703(82)90403-3 · Cited by 310
ROWELL, L. B., BRENGELMANN, G. L., BLACKMON, J. R., BRUGE, R. A., & MURRAY, J. A. (1968) · Circulation · doi:10.1161/01.cir.37.6.954 · Cited by 257
Comparison of Auscultatory and Oscillometric Blood Pressures
Park, M. K., Menard, S. W., & Yuan, C. (2001) · Archives of Pediatrics & Adolescent Medicine · doi:10.1001/archpedi.155.1.50 · Cited by 216
Fetics, B., Nevo, E., Chen, C.-H., & Kass, D. A. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.764946 · Cited by 211
Cited by
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Circulation · doi:10.1161/01.cir.0000154900.76284.f6 · Cited by 3,985
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Hypertension · doi:10.1161/01.hyp.0000150859.47929.8e · Cited by 2,051
Townsend, R. R., Wilkinson, I. B., Schiffrin, E. L., Avolio, A. P., Chirinos, J. A., Cockcroft, J. R., Heffernan, K. S., Lakatta, E. G., McEniery, C. M., Mitchell, G. F., et al. (2015) · Hypertension · doi:10.1161/hyp.0000000000000033 · Cited by 1,473
Central Blood Pressure Measurements and Antihypertensive Therapy: A Consensus Document
Agabiti-Rosei, E., Mancia, G., O’Rourke, M. F., Roman, M. J., Safar, M. E., Smulyan, H., Wang, J.-G., Wilkinson, I. B., Williams, B., & Vlachopoulos, C. (2007) · Hypertension · doi:10.1161/hypertensionaha.107.090068 · Cited by 620
Self-citationO’Rourke, M. F., & Nichols, W. W. (2005) · Hypertension · doi:10.1161/01.hyp.0000153793.84859.b8 · Cited by 543
Avolio, A. P., Van Bortel, L. M., Boutouyrie, P., Cockcroft, J. R., McEniery, C. M., Protogerou, A. D., Roman, M. J., Safar, M. E., Segers, P., & Smulyan, H. (2009) · Hypertension · doi:10.1161/hypertensionaha.109.134379 · Cited by 521
Self-citationValidation of a Brachial Cuff-Based Method for Estimating Central Systolic Blood Pressure
Weber, T., Wassertheurer, S., Rammer, M., Maurer, E., Hametner, B., Mayer, C. C., Kropf, J., & Eber, B. (2011) · Hypertension · doi:10.1161/hypertensionaha.111.176313 · Cited by 461
Schram, M. T., Henry, R. M. A., van Dijk, R. A. J. M., Kostense, P. J., Dekker, J. M., Nijpels, G., Heine, R. J., Bouter, L. M., Westerhof, N., & Stehouwer, C. D. A. (2004) · Hypertension · doi:10.1161/01.hyp.0000111829.46090.92 · Cited by 428
Chirinos, J. A., Zambrano, J. P., Chakko, S., Veerani, A., Schob, A., Willens, H. J., Perez, G., & Mendez, A. J. (2005) · Hypertension · doi:10.1161/01.hyp.0000165025.16381.44 · Cited by 364
Contour analysis of the photoplethysmographic pulse measured at the finger
Millasseau, S. C., Ritter, J. M., Takazawa, K., & Chowienczyk, P. J. (2006) · Journal of Hypertension · doi:10.1097/01.hjh.0000239277.05068.87 · Cited by 354
Herbert, A., Cruickshank, J. K., Laurent, S., & Boutouyrie, P. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu293 · Cited by 290
TAKAZAWA, K., KOBAYASHI, H., SHINDO, N., TANAKA, N., & YAMASHINA, A. (2007) · Hypertension Research · doi:10.1291/hypres.30.219 · Cited by 247
“The relations of carotid arterial pulse wave or central pulse wave information estimated from the radial artery to cardiovascular events and diseases have been reported (3), and a close relation to invasive central pulse wave information has also been reported (13).”
BackgroundMethodBenetos, A., Thomas, F., Joly, L., Blacher, J., Pannier, B., Labat, C., Salvi, P., Smulyan, H., & Safar, M. E. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.09.061 · Cited by 221
Self-citationGALLAGHER, D., ADJI, A., & OROURKE, M. (2004) · American Journal of Hypertension · doi:10.1016/j.amjhyper.2004.05.027 · Cited by 194
de Luca, N., Asmar, R. G., London, G. M., O'Rourke, M. F., & Safar, M. E. (2004) · Journal of Hypertension · doi:10.1097/01.hjh.0000125448.28861.fc · Cited by 192
Self-citationMatsui, Y., Eguchi, K., O'Rourke, M. F., Ishikawa, J., Miyashita, H., Shimada, K., & Kario, K. (2009) · Hypertension · doi:10.1161/hypertensionaha.109.131466 · Cited by 182
Dart, A. M., Gatzka, C. D., Kingwell, B. A., Willson, K., Cameron, J. D., Liang, Y.-L., Berry, K. L., Wing, L. M. H., Reid, C. M., Ryan, P., et al. (2006) · Hypertension · doi:10.1161/01.hyp.0000209340.33592.50 · Cited by 176
Verbeke, F., Segers, P., Heireman, S., Vanholder, R., Verdonck, P., & Van Bortel, L. M. (2005) · Hypertension · doi:10.1161/01.hyp.0000166723.07809.7e · Cited by 169
Sex Difference in Cardiovascular Risk
Regnault, V., Thomas, F., Safar, M. E., Osborne-Pellegrin, M., Khalil, R. A., Pannier, B., & Lacolley, P. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.01.044 · Cited by 162
Self-citationIncreased skin capillary density in treated essential hypertensive patients
DEBBABI, H., UZAN, L., MOURAD, J., SAFAR, M., LEVY, B., & TIBIRICA, E. (2006) · American Journal of Hypertension · doi:10.1016/j.amjhyper.2005.10.021 · Cited by 156
Self-citationMeasurements of arterial pressure and flow in vivo
Sharman, J. E., Segers, P., & Chirinos, J. A. (2022) · Textbook of Arterial Stiffness and Pulsatile Hemodynamics in Health and Disease · doi:10.1016/b978-0-323-91391-1.00002-9 · Cited by 3
Metadata
- Authors
- Smulyan, H., Siddiqui, D. S., Carlson, R. J., London, G. M., & Safar, M. E.
- Venue
- Hypertension
- Published
- 2003-08
- Volume
- 42
- Issue
- 2
- Pages
- 150-155
- ISSN
- 0194-911X (ISSN-L)
- 1524-4563
- OpenAlex
- W2127809264
- Cited by
- 179
- References
- 19
- FWCI
- 7.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.