Quantification of Perfusion Using Bolus Tracking Magnetic Resonance Imaging in Stroke: Assumptions, Limitations, and Potential Implications for Clinical Use
The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
Background — MR techniques have been very powerful in providing indicators of tissue perfusion, particularly in studies of cerebral ischemia. There is considerable interest in performing absolute perfusion measurements, with the aim of improving the characterization of tissue “at risk” of stroke. However, some important caveats relating to absolute measurements need to be taken into account. The purpose of this article is to discuss some of the issues involved and the potential implications for absolute cerebral blood flow measurements in clinical use. Summary of Comment — In bolus tracking MRI, deconvolution of the concentration-time course can in theory provide accurate quantification. However, there are several important assumptions in the tracer kinetic model used, some of which may be invalid in cerebral ischemia. These can introduce significant errors in perfusion quantification. Conclusions — Although we believe that bolus tracking MRI is a powerful technique for the evaluation of perfusion in cerebral ischemia, interpretation of perfusion maps requires caution; this is particularly true when absolute quantification is attempted. Work is currently under way in a number of centers to address these problems, and with appropriate modeling they may be overcome in the future. In the interim, we believe that it is necessary for users of bolus tracking perfusion data to be aware of the current technical limitations if they are to avoid misinterpretation or overinterpretation of their findings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Østergaard, L., Weisskoff, R. M., Chesler, D. A., Gyldensted, C., & Rosen, B. R. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360510 · Cited by 1,512
Perfusion imaging with NMR contrast agents
Rosen, B. R., Belliveau, J. W., Vevea, J. M., & Brady, T. J. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140211 · Cited by 1,151
Mr contrast due to intravascular magnetic susceptibility perturbations
Boxerman, J. L., Hamberg, L. M., Rosen, B. R., & Weisskoff, R. M. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340412 · Cited by 1,008
Østergaard, L., Sorensen, A. G., Kwong, K. K., Weisskoff, R. M., Gyldensted, C., & Rosen, B. R. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360511 · Cited by 810
Alsop, D. C., & Detre, J. A. (1996) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199611000-00019 · Cited by 754
Quantitative imaging of perfusion using a single subtraction (QUIPSS and QUIPSS II)
Wong, E. C., Buxton, R. B., & Frank, L. R. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390506 · Cited by 689
The ischemic penumbra: Operationally defined by diffusion and perfusion MRI
Schlaug, G., Benfield, A., Baird, A. E., Siewert, B., Lövblad, K. O., Parker, R. A., Edelman, R. R., & Warach, S. (1999) · Neurology · doi:10.1212/wnl.53.7.1528 · Cited by 663
Rempp, K. A., Brix, G., Wenz, F., Becker, C. R., Gückel, F., & Lorenz, W. J. (1994) · Radiology · doi:10.1148/radiology.193.3.7972800 · Cited by 639
Measuring Cerebral Blood Flow Using Magnetic Resonance Imaging Techniques
Calamante, F., Thomas, D. L., Pell, G. S., Wiersma, J., & Turner, R. (1999) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-199907000-00001 · Cited by 638
Self-citationCerebral blood flow determination by rapid-sequence computed tomography: theoretical analysis.
Axel, L. (1980) · Radiology · doi:10.1148/radiology.137.3.7003648 · Cited by 625
Cited by
Optimal Tmax Threshold for Predicting Penumbral Tissue in Acute Stroke
Olivot, J.-M., Mlynash, M., Thijs, V. N., Kemp, S., Lansberg, M. G., Wechsler, L., Bammer, R., Marks, M. P., & Albers, G. W. (2009) · Stroke · doi:10.1161/strokeaha.108.526954 · Cited by 401
Konstas, A. A., Goldmakher, G. V., Lee, T.-Y., & Lev, M. H. (2009) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1487 · Cited by 330
Models and methods for analyzing DCE‐MRI: A review
Khalifa, F., Soliman, A., El‐Baz, A., Abou El‐Ghar, M., El‐Diasty, T., Gimel'farb, G., Ouseph, R., & Dwyer, A. C. (2014) · Medical Physics · doi:10.1118/1.4898202 · Cited by 322
Arterial transit time imaging with flow encoding arterial spin tagging (FEAST)
Wang, J., Alsop, D. C., Song, H. K., Maldjian, J. A., Tang, K., Salvucci, A. E., & Detre, J. A. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10559 · Cited by 275
Perfusion Magnetic Resonance Imaging: A Comprehensive Update on Principles and Techniques
Jahng, G.-H., Li, K.-L., Ostergaard, L., & Calamante, F. (2014) · Korean Journal of Radiology · doi:10.3348/kjr.2014.15.5.554 · Cited by 256
Self-citationWelker, K., Boxerman, J., Kalnin, A., Kaufmann, T., Shiroishi, M., Wintermark, M., & for the American Society of Functional Neuroradiology MR Perfusion Standards and Practice Subcommittee of the ASFNR Clinical Practice Committee (2015) · American Journal of Neuroradiology · doi:10.3174/ajnr.a4341 · Cited by 243
“While there are opposing points of view on this issue, it should be recognized that selecting an AIF from the ischemic side will result in shorter MTT and higher CBF values on the ischemic side and a smaller area of hypoperfusion demonstrated on the perfusion maps.(75) The size difference in terms of hypoperfusion vol…”
Law, M., Saindane, A. M., Ge, Y., Babb, J. S., Johnson, G., Mannon, L. J., Herbert, J., & Grossman, R. I. (2004) · Radiology · doi:10.1148/radiol.2313030996 · Cited by 242
Refining the Perfusion–Diffusion Mismatch Hypothesis
Butcher, K. S., Parsons, M., MacGregor, L., Barber, P. A., Chalk, J., Bladin, C., Levi, C., Kimber, T., Schultz, D., Fink, J., et al. (2005) · Stroke · doi:10.1161/01.str.0000166181.86928.8b · Cited by 222
Arterial input function in perfusion MRI: A comprehensive review
Calamante, F. (2013) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2013.04.002 · Cited by 219
Self-citationAutomatic selection of arterial input function using cluster analysis
Mouridsen, K., Christensen, S., Gyldensted, L., & Østergaard, L. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20759 · Cited by 214
Measuring brain perfusion with intravoxel incoherent motion (IVIM): Initial clinical experience
Federau, C., O'Brien, K., Meuli, R., Hagmann, P., & Maeder, P. (2014) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24195 · Cited by 204
Arterial spin labeling MRI study of age and gender effects on brain perfusion hemodynamics
Liu, Y., Zhu, X., Feinberg, D., Guenther, M., Gregori, J., Weiner, M. W., & Schuff, N. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23286 · Cited by 191
Quantitative Measurement of Brain Perfusion with Intravoxel Incoherent Motion MR Imaging
Federau, C., Maeder, P., O’Brien, K., Browaeys, P., Meuli, R., & Hagmann, P. (2012) · Radiology · doi:10.1148/radiol.12120584 · Cited by 191
Dai, W., Robson, P. M., Shankaranarayanan, A., & Alsop, D. C. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23103 · Cited by 184
“However, wide clinical use has demonstrated the challenges of optimizing ASL acquisitions for subjects with very different vascular and perfusion characteristics (2,4,5).”
BackgroundKane, I., Carpenter, T., Chappell, F., Rivers, C., Armitage, P., Sandercock, P., & Wardlaw, J. (2007) · Stroke · doi:10.1161/strokeaha.107.483842 · Cited by 162
The Ischemic Penumbra: Correlates in Imaging and Implications for Treatment of Ischemic Stroke
Heiss, W.-D. (2011) · Cerebrovascular Diseases · doi:10.1159/000330462 · Cited by 158
Rose, S. E., Janke, A. L., Strudwick, M. W., McMahon, K. L., Chalk, J. B., Snyder, P., & De zubicaray, G. I. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20749 · Cited by 20
Metadata
- Authors
- Calamante, F., Gadian, D. G., & Connelly, A.
- Venue
- Stroke
- Published
- 2002-04
- Volume
- 33
- Issue
- 4
- Pages
- 1146-1151
- ISSN
- 0039-2499 (ISSN-L)
- 1524-4628
- OpenAlex
- W2146140938
- Cited by
- 283
- References
- 31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.