The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Home-Measured Blood Pressure Is a Stronger Predictor of Cardiovascular Risk Than Office Blood Pressure: The Finn-Home Study
Abstract
Previous studies with some limitations have provided equivocal results for the prognostic significance of home-measured blood pressure (BP). We investigated whether home-measured BP is more strongly associated with cardiovascular events and total mortality than is office BP. A prospective nationwide study was initiated in 2000 to 2001 on 2081 randomly selected subjects aged 45 to 74 years. Home and office BP were determined at baseline along with other cardiovascular risk factors. The primary end point was incidence of a cardiovascular event (cardiovascular mortality, nonfatal myocardial infarction, nonfatal stroke, hospitalization for heart failure, percutaneous coronary intervention, or coronary artery bypass graft surgery). The secondary end point was total mortality. After a mean follow-up of 6.8 years, 162 subjects had experienced a cardiovascular event, and 118 subjects had died. In Cox proportional hazard models adjusted for other cardiovascular risk factors, office BP (systolic/diastolic hazard ratio [HR] per 10/5 mm Hg increase in BP, 1.13/1.13; systolic/diastolic 95% confidence interval [CI], 1.05 to 1.22/1.05 to 1.22) and home BP (HR, 1.23/1.18; 95% CI, 1.13 to 1.34/1.10 to 1.27) were predictive of cardiovascular events. However, when both BPs were simultaneously included in the models, only home BP (HR, 1.22/1.15; 95% CI, 1.09 to 1.37/1.05 to 1.26), not office BP (HR, 1.01/1.06; 95% CI, 0.92 to 1.12/0.97 to 1.16), was predictive of cardiovascular events. Systolic home BP was the sole predictor of total mortality (HR, 1.11; 95% CI, 1.01/1.23). Our findings suggest that home-measured BP is prognostically superior to office BP. On the basis of the results of this and previous studies, it can be concluded that home BP measurement offers specific advantages more than conventional office measurement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“For strict management of hypertension control, home BP measurement has increasingly emerged as a key metric, supported by research findings that show a stronger association with cardiovascular risk factors compared to office BP [4,5].”
From The WHO Global report 2023 on hypertension warning the emerging hypertension burden in globe and its treatment strategy (2024) · cites this paper as [4]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chobanian, A. V. (2003) · JAMA · doi:10.1001/jama.289.19.2560 · Cited by 25,386
2013 ESH/ESC Guidelines for the management of arterial hypertension
Authors Task Force Members, Mancia, G., Fagard, R., Narkiewicz, K., Redon, J., Zanchetti, A., Böhm, M., Christiaens, T., Cífková, R., Backer, G. D., et al. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht151 · Cited by 13,739
Chobanian, A. V., Bakris, G. L., Black, H. R., Cushman, W. C., Green, L. A., Izzo, J. L., Jones, D. W., Materson, B. J., Oparil, S., Wright, J. T., et al. (2003) · Hypertension · doi:10.1161/01.hyp.0000107251.49515.c2 · Cited by 13,271
2007 Guidelines for the Management of Arterial Hypertension
Mancia, G., Backer, G. D., Dominiczak, A. F., Cífková, R., Fagard, R. H., Germanò, G., Grassi, G. M., Heagerty, A. M., Kjeldsen, S. E., Laurent, S., et al. (2007) · Journal of Hypertension · doi:10.1097/hjh.0b013e3281fc975a · Cited by 5,870
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Circulation · doi:10.1161/01.cir.0000154900.76284.f6 · Cited by 3,985
Selected major risk factors and global and regional burden of disease
Ezzati, M., Lopez, A. D., Rodgers, A., Vander Hoorn, S., & Murray, C. J. (2002) · The Lancet · doi:10.1016/s0140-6736(02)11403-6 · Cited by 3,594
Sega, R., Facchetti, R., Bombelli, M., Cesana, G., Corrao, G., Grassi, G., & Mancia, G. (2005) · Circulation · doi:10.1161/01.cir.0000160923.04524.5b · Cited by 1,009
Bobrie, G. (2004) · JAMA · doi:10.1001/jama.291.11.1342 · Cited by 842
Parati, G., Stergiou, G. S., Asmar, R., Bilo, G., de Leeuw, P., Imai, Y., Kario, K., Lurbe, E., Manolis, A., Mengden, T., et al. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e328308da66 · Cited by 837
Research works printed but not linked: 1
- Varis J, Savola H, Vesalainen R, Kantola I. Verenpainetaudin hoitotasapaino ei ole Suomessa vieläkään hyvä. Suom Laakaril. 2008; 63: 3289–3295.
Cited by
Sorted by citations
2013 ESH/ESC Guidelines for the management of arterial hypertension
Authors Task Force Members, Mancia, G., Fagard, R., Narkiewicz, K., Redon, J., Zanchetti, A., Böhm, M., Christiaens, T., Cífková, R., Backer, G. D., et al. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht151 · Cited by 13,739
2018 ESC/ESH Guidelines for the management of arterial hypertension
Williams, B., Mancia, G., Spiering, W., Agabiti Rosei, E., Azizi, M., Burnier, M., Clement, D. L., Coca, A., de Simone, G., Dominiczak, A., et al. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehy339 · Cited by 10,286
Mancia, G., Fagard, R., Narkiewicz, K., Redón, J., Zanchetti, A., Böhm, M., Christiaens, T., Cifkova, R., De Backer, G., Dominiczak, A., et al. (2013) · Journal of Hypertension · doi:10.1097/01.hjh.0000431740.32696.cc · Cited by 5,655
Williams, B., Mancia, G., Spiering, W., Agabiti Rosei, E., Azizi, M., Burnier, M., Clement, D. L., Coca, A., de Simone, G., Dominiczak, A., et al. (2018) · Journal of Hypertension · doi:10.1097/hjh.0000000000001940 · Cited by 2,885
Measurement of Blood Pressure in Humans: A Scientific Statement From the American Heart Association
Muntner, P., Shimbo, D., Carey, R. M., Charleston, J. B., Gaillard, T., Misra, S., Myers, M. G., Ogedegbe, G., Schwartz, J. E., Townsend, R. R., et al. (2019) · Hypertension · doi:10.1161/hyp.0000000000000087 · Cited by 1,512
Daskalopoulou, S. S., Rabi, D. M., Zarnke, K. B., Dasgupta, K., Nerenberg, K. A., Cloutier, L., Gelfer, M., Lamarre-Cliché, M., Milot, A., Bolli, P., et al. (2015) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2015.02.016 · Cited by 690
Principles and techniques of blood pressure measurement
Ogedegbe, G., & Pickering, T. (2002) · Cardiology Clinics · doi:10.1016/j.ccl.2010.07.006 · Cited by 290
Arterial hypertension in adults. Clinical guidelines 2020
Kobalava, Z. D., Конради, А. О., Nedogoda, S. V., Shlyakhto, E. V., Arutyunov, G. P., Баранова, Е. И., Барбараш, О. Л., Бойцов, С. А., Вавилова, Т. В., Вадимовна, В. С., et al. (2020) · Russian Journal of Cardiology · doi:10.15829/1560-4071-2020-3-3786 · Cited by 609
Siu, A. L., & on behalf of the U.S. Preventive Services Task Force* (2015) · Annals of Internal Medicine · doi:10.7326/m15-2223 · Cited by 504
2013 ESH/ESC Guidelines for the management of arterial hypertension
Mancia, G., Fagard, R. H., Narkiewicz, K., Redón, J., Zanchetti, A., Böhm, M., Christiaens, T. C., Cífková, R., Backer, G. D., Dominiczak, A. F., et al. (2013) · Blood Pressure · doi:10.3109/08037051.2013.812549 · Cited by 430
Kario, K., Okura, A., Hoshide, S., & Mogi, M. (2024) · Hypertension Research · doi:10.1038/s41440-024-01622-w · Cited by 425
Piper, M., Evans, C. V., Burda, B. U., Margolis, K. L., O’Connor, E., & Whitlock, E. P. (2014) · Annals of Internal Medicine · doi:10.7326/m14-1539 · Cited by 389
Stergiou, G. S., Asayama, K., Thijs, L., Kollias, A., Niiranen, T. J., Hozawa, A., Boggia, J., Johansson, J. K., Ohkubo, T., Tsuji, I., et al. (2014) · Hypertension · doi:10.1161/hypertensionaha.113.02741 · Cited by 304
Self-citationWard, A. M., Takahashi, O., Stevens, R., & Heneghan, C. (2012) · Journal of Hypertension · doi:10.1097/hjh.0b013e32834e4aed · Cited by 296
Hypertension in Chronic Kidney Disease
Hamrahian, S. M., & Falkner, B. E. (2016) · Advances in experimental medicine and biology · doi:10.1007/5584_2016_84 · Cited by 271
Johansson, J. K., Niiranen, T. J., Puukka, P. J., & Jula, A. M. (2012) · Hypertension · doi:10.1161/hypertensionaha.111.178657 · Cited by 240
Self-citationManagement of Hypertension in the Digital Era
Kario, K. (2020) · Hypertension · doi:10.1161/hypertensionaha.120.14742 · Cited by 247
Wearable and Mobile Sensors for Personalized Nutrition
Sempionatto, J. R., Montiel, V. R.-V., Vargas, E., Teymourian, H., & Wang, J. (2021) · ACS Sensors · doi:10.1021/acssensors.1c00553 · Cited by 237
Quigley, K. S., Gianaros, P. J., Norman, G. J., Jennings, J. R., Berntson, G. G., & de Geus, E. J. C. (2024) · Psychophysiology · doi:10.1111/psyp.14604 · Cited by 281
Hoshide, S., Yano, Y., Haimoto, H., Yamagiwa, K., Uchiba, K., Nagasaka, S., Matsui, Y., Nakamura, A., Fukutomi, M., Eguchi, K., et al. (2016) · Hypertension · doi:10.1161/hypertensionaha.116.07201 · Cited by 235
2024 Clinical practice guidelines for Hypertension in adults
Кобалава, Ж. Д., Конради, А. О., Nedogoda, S. V., Shlyakhto, E. V., Arutyunov, G. P., Баранова, Е. И., Барбараш, О. Л., Bobkova, N. V., Boytsov, S. A., Bubnova, M. G., et al. (2024) · Russian Journal of Cardiology · doi:10.15829/1560-4071-2024-6117 · Cited by 274
Imai, Y., Kario, K., Shimada, K., Kawano, Y., Hasebe, N., Matsuura, H., Tsuchihashi, T., Ohkubo, T., Kuwajima, I., & Miyakawa, M. (2012) · Hypertension Research · doi:10.1038/hr.2012.56 · Cited by 204
Chiang, C., Wang, T., Ueng, K.-C., Lin, T., Yeh, H., Chen, C.-Y., Wu, Y.-J., Tsai, W., Chao, T., Chen, C.-H., et al. (2014) · Journal of the Chinese Medical Association · doi:10.1016/j.jcma.2014.11.005 · Cited by 203
on behalf of Hypertension Objective Treatment Based on Measurement by Electrical Devices of Blood Pressure (HOMED-BP) investigators, Asayama, K., Ohkubo, T., Metoki, H., Obara, T., Inoue, R., Kikuya, M., Thijs, L., Staessen, J. A., & Imai, Y. (2012) · Hypertension Research · doi:10.1038/hr.2012.125 · Cited by 186
Morning Home Blood Pressure Is a Strong Predictor of Coronary Artery Disease
Kario, K., Saito, I., Kushiro, T., Teramukai, S., Tomono, Y., Okuda, Y., & Shimada, K. (2016) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.01.037 · Cited by 182
Kim, H., Lee, E. M., Ahn, S. Y., Kim, K., Kim, H. C., Kim, J. H., Lee, H., Lee, J. H., Park, J., Cho, E. J., et al. (2023) · Clinical Hypertension · doi:10.1186/s40885-023-00234-9 · Cited by 168
Kario, K., Saito, I., Kushiro, T., Teramukai, S., Ishikawa, Y., Mori, Y., Kobayashi, F., & Shimada, K. (2014) · Hypertension · doi:10.1161/hypertensionaha.114.04262 · Cited by 162
Office, Home, and Ambulatory Blood Pressures as Predictors of Cardiovascular Risk
Niiranen, T. J., Mäki, J., Puukka, P., Karanko, H., & Jula, A. M. (2014) · Hypertension · doi:10.1161/hypertensionaha.114.03292 · Cited by 143
Self-citationAmbulatory Blood Pressure Monitoring in the Diagnosis and Management of Hypertension
Grossman, E. (2013) · Diabetes Care · doi:10.2337/dcs13-2039 · Cited by 144
Blood pressure variability: its relevance for cardiovascular homeostasis and cardiovascular diseases
Parati, G., Torlasco, C., Pengo, M., Bilo, G., & Ochoa, J. E. (2020) · Hypertension Research · doi:10.1038/s41440-020-0421-5 · Cited by 137
Home Blood Pressure Variability as Cardiovascular Risk Factor in the Population of Ohasama
Asayama, K., Kikuya, M., Schutte, R., Thijs, L., Hosaka, M., Satoh, M., Hara, A., Obara, T., Inoue, R., Metoki, H., et al. (2012) · Hypertension · doi:10.1161/hypertensionaha.111.00138 · Cited by 130
Maximum Value of Home Blood Pressure: A Novel Indicator of Target Organ Damage in Hypertension
Matsui, Y., Ishikawa, J., Eguchi, K., Shibasaki, S., Shimada, K., & Kario, K. (2011) · Hypertension · doi:10.1161/hypertensionaha.111.171645 · Cited by 127
Nighttime Home Blood Pressure and the Risk of Hypertensive Target Organ Damage
Ishikawa, J., Hoshide, S., Eguchi, K., Ishikawa, S., Shimada, K., Kario, K., & for the Japan Morning Surge-Home Blood Pressure Study Investigators Group (2012) · Hypertension · doi:10.1161/hypertensionaha.112.198101 · Cited by 123
Niiranen, T. J., Asayama, K., Thijs, L., Johansson, J. K., Ohkubo, T., Kikuya, M., Boggia, J., Hozawa, A., Sandoya, E., Stergiou, G. S., et al. (2013) · Hypertension · doi:10.1161/hypertensionaha.111.00100 · Cited by 120
Self-citation(2022) · PubMed Central · doi:10.6515/acs.202205_38(3).20220321a · Cited by 117
Blood Pressure Measurement and Treatment Decisions
Kario, K., Thijs, L., & Staessen, J. A. (2019) · Circulation Research · doi:10.1161/circresaha.118.313219 · Cited by 111
Fujiwara, T., Yano, Y., Hoshide, S., Kanegae, H., & Kario, K. (2018) · JAMA Cardiology · doi:10.1001/jamacardio.2018.1233 · Cited by 106
Blood Pressure Measurement: Clinic, Home, Ambulatory, and Beyond
Drawz, P. E., Abdalla, M., & Rahman, M. (2012) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2012.01.026 · Cited by 104
Imai, Y., Obara, T., Asamaya, K., & Ohkubo, T. (2013) · Hypertension Research · doi:10.1038/hr.2013.38 · Cited by 102
A New Algorithm for the Diagnosis of Hypertension in Canada
Cloutier, L., Daskalopoulou, S. S., Padwal, R. S., Lamarre-Cliché, M., Bolli, P., McLean, D., Milot, A., Tobe, S. W., Tremblay, G., McKay, D. W., et al. (2015) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2015.02.014 · Cited by 100
Home Blood Pressure Monitoring
Casella, G., & MacDonald, T. M. (2015) · European Cardiology Review · doi:10.15420/ecr.2015.10.2.95 · Cited by 99
Hoshide, S., Yano, Y., Mizuno, H., Kanegae, H., & Kario, K. (2018) · HYPERTENSION · doi:10.1161/hypertensionaha.117.10385 · Cited by 82
on behalf of the HOPE Asia Network, Park, S., Buranakitjaroen, P., Chen, C.-H., Chia, Y. C., Divinagracia, R. A., Hoshide, S., Shin, J., Siddique, S., Sison, J., et al. (2018) · Journal of Human Hypertension · doi:10.1038/s41371-017-0025-y · Cited by 94
Home Blood Pressure Monitoring: Current Status and New Developments
Kario, K. (2021) · American Journal of Hypertension · doi:10.1093/ajh/hpab017 · Cited by 106
Masked hypertension and cardiovascular outcomes: an updated systematic review and meta-analysis
Palla, M., Saber, H., Konda, S., & Briasoulis, Α. (2018) · Integrated Blood Pressure Control · doi:10.2147/ibpc.s128947 · Cited by 88
Asayama, K., Thijs, L., Brguljan-Hitij, J., Niiranen, T. J., Hozawa, A., Boggia, J., Aparicio, L. S., Hara, A., Johansson, J. K., Ohkubo, T., et al. (2014) · PLoS Medicine · doi:10.1371/journal.pmed.1001591 · Cited by 87
Self-citationUsing Benefit-Based Tailored Treatment to Improve the Use of Antihypertensive Medications
Sussman, J. B., Vijan, S. S., & Hayward, R. A. (2013) · Circulation · doi:10.1161/circulationaha.113.002290 · Cited by 84
Home Blood Pressure as a Cardiovascular Outcome Predictor: It’s Time to Take This Method Seriously
Stergiou, G. S., Siontis, K. C. M., & Ioannidis, J. P. A. (2010) · Hypertension · doi:10.1161/hypertensionaha.110.150771 · Cited by 84
Outcome-Driven Thresholds for Increased Home Blood Pressure Variability
Juhanoja, E. P., Niiranen, T. J., Johansson, J. K., Puukka, P. J., Thijs, L., Asayama, K., Langén, V. L., Hozawa, A., Aparicio, L. S., Ohkubo, T., et al. (2017) · Hypertension · doi:10.1161/hypertensionaha.116.08603 · Cited by 83
Self-citationHome blood pressure monitoring: Australian Expert Consensus Statement
Sharman, J. E., Howes, F. S., Head, G. A., McGrath, B. P., Stowasser, M., Schlaich, M., Glasziou, P., & Nelson, M. R. (2015) · Journal of Hypertension · doi:10.1097/hjh.0000000000000673 · Cited by 83
Hoshide, S., Kario, K., Yano, Y., Haimoto, H., Yamagiwa, K., Uchiba, K., Nagasaka, S., Matsui, Y., Nakamura, A., Fukutomi, M., et al. (2014) · American Journal of Hypertension · doi:10.1093/ajh/hpt290 · Cited by 77
2020 Consensus summary on the management of hypertension in Asia from the HOPE Asia Network
Kario, K., Park, S., Chia, Y., Sukonthasarn, A., Turana, Y., Shin, J., Chen, C., Buranakitjaroen, P., Divinagracia, R., Nailes, J., et al. (2020) · The Journal of Clinical Hypertension · doi:10.1111/jch.13751 · Cited by 76
Blood Pressure Measurement Anno 2016
Staessen, J. A., Li, Y., Hara, A., Asayama, K., Dolan, E., & O'Brien, E. T. (2017) · American Journal of Hypertension · doi:10.1093/ajh/hpw148 · Cited by 75
Blood pressure variability and outcomes in chronic kidney disease
Iorio, B. R. D., Pota, A., Sirico, M. L., Torraca, S., Micco, L. D., Rubino, R., Guastaferro, P., & Bellasi, A. (2012) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfs328 · Cited by 76
Arrieta, A., Woods, J. R., Qiao, N., & Jay, S. J. (2014) · Hypertension · doi:10.1161/hypertensionaha.114.03780 · Cited by 75
Optimal Schedule for Home Blood Pressure Measurement Based on Prognostic Data: The Finn-Home Study
Niiranen, T. J., Johansson, J. K., Reunanen, A., & Jula, A. M. (2011) · Hypertension · doi:10.1161/hypertensionaha.110.162123 · Cited by 71
Self-citationGuidance on home blood pressure monitoring: A statement of the HOPE Asia Network
Kario, K., Park, S., Buranakitjaroen, P., Chia, Y. C., Chen, C., Divinagracia, R. A., Hoshide, S., Shin, J., Siddique, S., Sison, J., et al. (2018) · Journal of Clinical Hypertension · doi:10.1111/jch.13216 · Cited by 70
Prediction of blood pressure variability using deep neural networks
Koshimizu, H., Kojima, R., Kario, K., & Okuno, Y. (2020) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2019.104067 · Cited by 70
Tsioufis, K. P., Kreutz, R. H., Sykara, G. D., van Vugt, J., & Hassan, T. (2020) · Journal of Hypertension · doi:10.1097/hjh.0000000000002381 · Cited by 72
Prognostic significance of masked and white-coat hypertension in the general population
Hänninen, M.-R. A., Niiranen, T., Puukka, P. J., Johansson, J. K., & Jula, A. (2012) · Journal of Hypertension · doi:10.1097/hjh.0b013e328350a69b · Cited by 68
Self-citationKario, K., Tomitani, N., Buranakitjaroen, P., Chia, Y. C., Park, S., Chen, C., Divinagracia, R. A., Shin, J., Siddique, S., Sison, J., et al. (2018) · Journal of Clinical Hypertension · doi:10.1111/jch.13415 · Cited by 65
Parupelli, S. K., & Desai, S. S. (2023) · Bioengineering · doi:10.3390/bioengineering11010032 · Cited by 69
Cepeda, M., Pham, P., & Shimbo, D. (2023) · Hypertension Research · doi:10.1038/s41440-022-01137-2 · Cited by 68
Implementing Home Blood Pressure Monitoring into Clinical Practice
Liyanage-Don, N. A., Fung, D., Phillips, E., & Kronish, I. M. (2019) · Current Hypertension Reports · doi:10.1007/s11906-019-0916-0 · Cited by 62
Li, Y., Thijs, L., Zhang, Z., Asayama, K., Hansen, T. W., Boggia, J. G., Björklund‐Bodegârd, K., Yang, W., Niiranen, T., Ntineri, A., et al. (2019) · Hypertension · doi:10.1161/hypertensionaha.119.12958 · Cited by 55
Self-citationNoguchi, Y., Asayama, K., Staessen, J. A., Inaba, M., Ohkubo, T., Hosaka, M., Satoh, M., Kamide, K., Awata, T., Katayama, S., et al. (2013) · Journal of Hypertension · doi:10.1097/hjh.0b013e328361732c · Cited by 53
Slowing progression of chronic kidney disease
Drawz, P. E., & Rosenberg, M. E. (2013) · Kidney International Supplements · doi:10.1038/kisup.2013.80 · Cited by 51
Nikolic, S. B., Abhayaratna, W. P., Leano, R., Stowasser, M., & Sharman, J. E. (2013) · Journal of Human Hypertension · doi:10.1038/jhh.2013.38 · Cited by 50
Parati, G., Omboni, S., Compare, A., Grossi, E., Callus, E., Venco, A., Destro, M., Villa, G., Palatini, P., Rosei, E. A., et al. (2013) · Trials · doi:10.1186/1745-6215-14-22 · Cited by 49
Mild hypertension in people at low risk
Martin, S. A., Boucher, M., Wright, J. M., & Saini, V. (2014) · BMJ · doi:10.1136/bmj.g5432 · Cited by 49
Narita, K., Hoshide, S., & Kario, K. (2021) · Hypertension Research · doi:10.1038/s41440-021-00686-2 · Cited by 49
An instrument for measuring blood pressure and assessing cardiovascular health from the fingertip
Panula, T., Koivisto, T., Pänkäälä, M., Niiranen, T., Kantola, I. M., & Kaisti, M. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112483 · Cited by 50
Self-citationKamide, K., Asayama, K., Katsuya, T., Ohkubo, T., Hirose, T., Inoue, R., Metoki, H., Kikuya, M., Obara, T., Hanada, H., et al. (2013) · Pharmacogenomics · doi:10.2217/pgs.13.161 · Cited by 45
Ishikawa, J., Shimizu, M., Edison, E. S., Yano, Y., Hoshide, S., Eguchi, K., & Kario, K. (2013) · Journal of Hypertension · doi:10.1097/hjh.0b013e328365c8a8 · Cited by 45
Narita, K., Hoshide, S., Fujiwara, T., Kanegae, H., & Kario, K. (2020) · American Journal of Hypertension · doi:10.1093/ajh/hpaa027 · Cited by 44
Lee, E. M. (2024) · Clinical Hypertension · doi:10.1186/s40885-024-00265-w · Cited by 52
Optimal Number of Days for Home Blood Pressure Measurement
Niiranen, T. J., Asayama, K., Thijs, L., Johansson, J. K., Hara, A., Hozawa, A., Tsuji, I., Ohkubo, T., Jula, A. M., Imai, Y., et al. (2015) · American Journal of Hypertension · doi:10.1093/ajh/hpu216 · Cited by 43
Self-citationSelf-monitoring blood pressure in patients with hypertension: an internet-based survey of UK GPs
Fletcher, B., Hinton, L., Bray, E. P., Hayen, A. D., Hobbs, R. F., Mant, J., Potter, J. F., & McManus, R. J. (2016) · British Journal of General Practice · doi:10.3399/bjgp16x687037 · Cited by 44
Bello, N. A., Schwartz, J. E., Kronish, I. M., Oparil, S., Anstey, D. E., Wei, Y., Cheung, Y. K. K., Muntner, P., & Shimbo, D. (2018) · Journal of the American Heart Association · doi:10.1161/jaha.118.008658 · Cited by 42
Barochiner, J., Cuffaro, P. E., Aparicio, L. S., Alfie, J., Rada, M., Morales, M. S., Galarza, C. R., & Waisman, G. D. (2013) · American Journal of Hypertension · doi:10.1093/ajh/hpt036 · Cited by 42
Lin, H., Wang, T., Chen, M. Y., Hsu, C., Wang, K.-L., Huang, C., Hsieh, M., Chiu, Y.-W., Chiang, L.-T., Chuang, W.-P., et al. (2020) · PubMed Central · doi:10.6515/acs.202011_36(6).20201106a · Cited by 40
Home blood pressure variability and subclinical atherosclerosis in multiple vascular beds
Hisamatsu, T., Miura, K., Ohkubo, T., Arima, H., Fujiyoshi, A., Satoh, A., Kadota, A., Zaid, M., Takashima, N., Ohno, S., et al. (2018) · Journal of Hypertension · doi:10.1097/hjh.0000000000001810 · Cited by 39
Luo, Y., Wang, Y., Wu, Y., Xu, Y., Head, G. A., Barry, M., & Liang, Y. (2013) · Chinese Medical Journal · doi:10.3760/cma.j.issn.0366-6999.20122110 · Cited by 40
Narita, K., Hoshide, S., & Kario, K. (2022) · Hypertension · doi:10.1161/hypertensionaha.122.19494 · Cited by 40
Single-Night Diagnosis of Sleep Apnea Contributes to Inconsistent Cardiovascular Outcome Findings
Lechat, B., Nguyen, D. P., Reynolds, A. C., Loffler, K. A., Escourrou, P., McEvoy, R. D., Adams, R., CATCHESIDE, P. G., & Eckert, D. J. (2023) · CHEST Journal · doi:10.1016/j.chest.2023.01.027 · Cited by 43
Mancia, G., Facchetti, R., Seravalle, G., Cuspidi, C., Corrao, G., & Grassi, G. (2021) · Hypertension · doi:10.1161/hypertensionaha.120.16303 · Cited by 37
Nonadherence to Recommended Guidelines for Blood Pressure Measurement
Levy, J., Gerber, L. M., Wu, X., & Mann, S. J. (2016) · Journal of Clinical Hypertension · doi:10.1111/jch.12846 · Cited by 35
Al-Karkhi, I., Al-Rubaiy, R., Rosenqvist, U., Falk, M., & Nyström, F. H. (2014) · Blood Pressure Monitoring · doi:10.1097/mbp.0000000000000088 · Cited by 35
Niiranen, T., Rissanen, H. A., Johansson, J. K., & Jula, A. (2014) · Journal of Hypertension · doi:10.1097/hjh.0000000000000070 · Cited by 36
Self-citationUchmanowicz, I., Jankowska‐Polańska, B., Chudiak, A., Szymańska–Chabowska, A., & Mazur, G. J. (2016) · BMC Cardiovascular Disorders · doi:10.1186/s12872-016-0270-y · Cited by 35
Bonafini, S., & Fava, C. (2015) · Blood Pressure · doi:10.3109/08037051.2015.1070599 · Cited by 34
Ntineri, A., Kalogeropoulos, P. G., Kyriakoulis, K. G., Aissopou, E. K., Thomopoulou, G., Kollias, A., & Stergiou, G. S. (2018) · Journal of Hypertension · doi:10.1097/hjh.0000000000001497 · Cited by 34
Brazilian Guidelines for In-office and Out-of-office Blood Pressure Measurement – 2023
Feitosa, A. D. M., Barroso, W. K. S., Mion, D., Nobre, F. D., Gomes, M. A. M., Jardim, P. C. B. V., Amodeo, C., Oliveira, A. C., Alessi, A., Sousa, A. L. L., et al. (2024) · Arquivos Brasileiros de Cardiologia · doi:10.36660/abc.20240113i · Cited by 32
on behalf of the IDHOCO investigators, Niiranen, T., Thijs, L., Asayama, K., Johansson, J. K., Ohkubo, T., Kikuya, M., Boggia, J. G., Hozawa, A., Sandoya, E., et al. (2012) · Hypertension Research · doi:10.1038/hr.2012.97 · Cited by 32
Self-citationSchwartz, C., & McManus, R. J. (2015) · BMC Medicine · doi:10.1186/s12916-015-0502-5 · Cited by 35
Schillaci, G., Pucci, G., & Parati, G. (2011) · Hypertension · doi:10.1161/hypertensionaha.111.175752 · Cited by 33
Human Errors in Automated Office Blood Pressure Measurement: Still Room for Improvement
Elias, M. F., & Goodell, A. L. (2021) · Hypertension · doi:10.1161/hypertensionaha.120.16164 · Cited by 31
Diretrizes Brasileiras de Medidas da Pressão Arterial Dentro e Fora do Consultório – 2023
Feitosa, A. D. M., Barroso, W. K. S., Mion, D., Nobre, F. D., Gomes, M. A. M., Jardim, P. C. B. V., Amodeo, C., Oliveira, A. C., Alessi, A., Sousa, A. L. L., et al. (2024) · Arquivos Brasileiros de Cardiologia · doi:10.36660/abc.20240113 · Cited by 53
Cheng, Y.-B., Thijs, L., Zhang, Z.-Y., Kikuya, M., Yang, W.-Y., Melgarejo, J., Boggia, J., Wei, F.-F., Hansen, T., Yu, C.-G., et al. (2019) · HYPERTENSION · doi:10.1161/hypertensionaha.119.13512 · Cited by 21
Lindroos, A. S., Johansson, J. K., Puukka, P. J., Kantola, I. M., Salomaa, V. V., Juhanoja, E. P., Sivén, S. S. E., Jousilahti, P., Jula, A., & Niiranen, T. (2016) · Journal of Hypertension · doi:10.1097/hjh.0000000000000995 · Cited by 33
Self-citation
Metadata
- Authors
- Niiranen, T. J., Hänninen, M.-R., Johansson, J., Reunanen, A., & Jula, A. M.
- Affiliations
- Turku University Hospital (FI)
- From the Population Studies Unit (T.J.N., M.-R.H., J.J., A.M.J.), National Institute for Health and Welfare, Turku, Finland; Department of Medicine (T.J.N.), Turku University Hospital, Turku, Finland; Living Conditions, Health and Wellbeing Unit (A.R.), National Institute for Health and Welfare, Helsinki, Finland.
- Venue
- Hypertension
- Published
- 2010-06
- Volume
- 55
- Issue
- 6
- Pages
- 1346-1351
- ISSN
- 0194-911X (ISSN-L)
- 1524-4563
- OpenAlex
- W2155309039
- Cited by
- 390
- References
- 29
- Citations by year
- 2026: 16 · 2025: 12 · 2024: 19 · 2023: 29 · 2022: 27 · 2021: 23 · 2020: 21 · 2019: 26 · 2018: 33 · 2017: 19 · 2016: 22 · 2015: 28 · 2014: 34 · 2013: 29 · 2012: 32
- FWCI
- 17.78
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Hypertension (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Työsuojelurahasto
- Suomen Hammaslääkäriliitto
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Health Sciences › Nursing › Nutrition and Dietetics › Sodium Intake and Health
- Keywords
- home blood pressure monitoring, office blood pressure, cardiovascular risk prediction, cardiovascular events, all-cause mortality, systolic blood pressure, prognostic value
- MeSH terms
- Aged, Blood Pressure Determination, Cardiovascular Diseases, Cause of Death, Female, Finland, Humans, Hypertension, Male, Middle Aged, Office Visits, Predictive Value of Tests, Probability, Prognosis, Reproducibility of Results, Cohort Studies, Prevalence, Proportional Hazards Models, Survival Analysis, Risk Assessment, Blood Pressure Monitoring, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review