Quantitative Comparison of the Sensitivity of Detection of Fluorescent and Bioluminescent Reporters in Animal Models
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
Bioluminescent and fluorescent reporters are finding increased use in optical molecular imaging in small animals. In the work presented here, issues related to the sensitivity of in vivo detection are examined for standard reporters. A high-sensitivity imaging system that can detect steady-state emission from both bioluminescent and fluorescent reporters is described. The instrument is absolutely calibrated so that animal images can be analyzed in physical units of radiance allowing more quantitative comparisons to be performed. Background emission from mouse tissue, called autoluminescence and autofluorescence, is measured and found to be an important limitation to detection sensitivity of reporters. Measurements of dual-labeled (bioluminescent/fluorescent) reporter systems, including PC-3M-luc/DsRed2-1 and HeLa-luc/PKH26, are shown. The results indicate that although fluorescent signals are generally brighter than bioluminescent signals, the very low autoluminescent levels usually results in superior signal to background ratios for bioluminescent imaging, particularly compared with fluorescent imaging in the green to red part of the spectrum. Fluorescence detection sensitivity improves in the far-red to near-infrared, provided the animals are fed a low-chlorophyll diet to reduce autofluorescence in the intestinal region. The use of blue-shifted excitation filters is explored as a method to subtract out tissue autofluorescence and improve the sensitivity of fluorescent imaging.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Wave Propagation and Scattering in Random Media
(1978) · Elsevier eBooks · doi:10.1016/c2013-0-10906-3 · Cited by 4,709
A review of the optical properties of biological tissues
Cheong, W. F., Prahl, S. A., & Welch, A. J. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64354 · Cited by 2,530 · cited 1×
“5 cm 1 for wavelengths between 600 and 1000 nm [25].”
BackgroundWater-Soluble Quantum Dots for Multiphoton Fluorescence Imaging in Vivo
Larson, D. R., Zipfel, W. R., Williams, R. M., Clark, S. W., Bruchez, M. P., Wise, F. W., & Webb, W. W. (2003) · Science · doi:10.1126/science.1083780 · Cited by 2,286
In vivo imaging of tumors with protease-activated near-infrared fluorescent probes
Weissleder, R., Tung, C.-H., Mahmood, U., & Bogdanov, A. (1999) · Nature Biotechnology · doi:10.1038/7933 · Cited by 1,591
Åkerman, M. E., Chan, W. C. W., Laakkonen, P., Bhatia, S. N., & Ruoslahti, E. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.152463399 · Cited by 1,437 · cited 1×
“probes such as quantum dots are also beginning to find biological applications [15–17].”
BackgroundBoundary conditions for the diffusion equation in radiative transfer
Haskell, R. C., Svaasand, L. O., Tsay, T.-T., Feng, T.-C., Tromberg, B. J., & McAdams, M. S. (1994) · Journal of the Optical Society of America A · doi:10.1364/josaa.11.002727 · Cited by 1,138 · cited 1×
“bounded medium requires treatment of the tissue–air boundary conditions [27].”
BackgroundFluorescence molecular tomography resolves protease activity in vivo
Ntziachristos, V., Tung, C.-H., Bremer, C., & Weissleder, R. (2002) · Nature Medicine · doi:10.1038/nm729 · Cited by 827 · cited 1×
“For applications such as tumor visualization, target-activated probes have been used [9,10].”
MethodPhotonic detection of bacterial pathogens in living hosts
Contag, C. H., Contag, P. R., Mullins, J. I., Spilman, S. D., Stevenson, D. K., & Benaron, D. A. (1995) · Molecular Microbiology · doi:10.1111/j.1365-2958.1995.mmi_18040593.x · Cited by 652 · cited 1×
“This technology has a large range of applications, including study of infectious disease, oncology, pharmacokinetics and pharmacodynamics, toxicology, and gene expression in light-producing transgenic animals [1–12].”
BackgroundSelection of Quantum Dot Wavelengths for Biomedical Assays and Imaging
Lim, Y. T., Kim, S., Nakayama, A., Stott, N. E., Bawendi, M. G., & Frangioni, J. V. (2003) · Molecular Imaging · doi:10.1162/15353500200302163 · Cited by 559
Optical imaging of Renilla luciferase reporter gene expression in living mice
Bhaumik, S., & Gambhir, S. S. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.012611099 · Cited by 536 · cited 1×
“This technology has a large range of applications, including study of infectious disease, oncology, pharmacokinetics and pharmacodynamics, toxicology, and gene expression in light-producing transgenic animals [1–12].”
Background
Cited by
Items 101–200 of 470
Hettiaratchi, M. H., Rouse, T., Chou, C., Krishnan, L., Stevens, H. Y., Li, M.-T. A., McDevitt, T. C., & Guldberg, R. E. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.06.028 · Cited by 58
“Subcutaneous implantation of biomaterials facilitated longitudinal tracking of fluorescently labeled BMP-2 [33], overcoming the limitation in fluorescent signal visualization observed in deeper tissues [34].”
BackgroundDevelopment of bioluminescent Edwardsiella ictaluri for noninvasive disease monitoring
Karsi, A., Menanteau‐Ledouble, S., & Lawrence, M. L. (2006) · FEMS Microbiology Letters · doi:10.1111/j.1574-6968.2006.00310.x · Cited by 57
Li, J., Zhou, W., Ouyang, X., Huan, Y., Yang, R., Tan, W., & Yuan, J. (2011) · Analytical Chemistry · doi:10.1021/ac102710w · Cited by 56
Imaging prostate cancer lymph node metastases with a multimodality contrast agent
Hall, M. A., Kwon, S., Robinson, H., Lachance, P., Azhdarinia, A., Ranganathan, R., Price, R. E., Chan, W., & Sevick-Muraca, E. M. (2011) · The Prostate · doi:10.1002/pros.21413 · Cited by 56
“Unfortunately, the sensitivity for DsRed detection using our imaging system has not been determined previously, but is known to depend upon sufficient protein expression levels that provide fluorescence above the noise floor of the imaging system as well as that from tissue autofluorescence [67,68].”
BackgroundSaban, M. R., Backer, J. M., Backer, M. V., Maier, J., Fowler, B., Davis, C. A., Simpson, C., Wu, X., Birder, L. A., Freeman, M. R., et al. (2008) · American Journal of Physiology-Renal Physiology · doi:10.1152/ajprenal.00618.2007 · Cited by 55
In Vitro and In Vivo Bioluminescent Quantification of Viable Stem Cells in Engineered Constructs
Logeart‐Avramoglou, D., Oudina, K., Bourguignon, M., Delpierre, L., Nicola, M., Bensidhoum, M., Arnaud, É., & Petite, H. (2009) · Tissue Engineering Part C Methods · doi:10.1089/ten.tec.2009.0004 · Cited by 54
Molecular imaging of microRNAs
Wang, F., Niu, G., Chen, X. S., & Cao, F. (2011) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-011-1786-0 · Cited by 54
“However, in vivo small-animal imaging using these fluorescent proteins as reporters will suffer from autofluorescence background and limited tissue penetration of light, and consequently low signal-to-background contrast [37].”
BackgroundBogaards, A., Sterenborg, H. J. C. M., Trachtenberg, J., Wilson, B. C., & Lilge, L. D. (2007) · Lasers in Surgery and Medicine · doi:10.1002/lsm.20525 · Cited by 54
Small Animal Imaging Center Design: The Facility at the UCLA Crump Institute for Molecular Imaging
Stout, D. B., Chatziioannou, A. F., Lawson, T. P., Silverman, R. W., Gambhir, S. S., & Phelps, M. E. (2005) · Molecular Imaging and Biology · doi:10.1007/s11307-005-0015-2 · Cited by 52
“In our facility, the supported devices are microPET [4], microCAT [5], optical imaging [1, 6], and digital autoradiography with a cryosectioning and imaging system.”
MethodSlow Disease Progression in a C57BL/6 Pten-Deficient Mouse Model of Prostate Cancer
Svensson, R. U., Haverkamp, J. M., Thedens, D. R., Cohen, M. B., Ratliff, T. L., & Henry, M. D. (2011) · American Journal Of Pathology · doi:10.1016/j.ajpath.2011.03.014 · Cited by 51
“ROSA26 promoter and/or white coat color may facilitate detection of pathological changes in the prostate.(22) In support of this notion, we observed that bioluminescence signal in C57/Luc/Pten / mice increased significantly from 28 weeks of age, compared with C57/Luc/Pten / mice (Figure 1B).”
BackgroundZheng, J., Nie, Y., Hu, Y., Li, J., Li, Y., Jiang, Y. Y., & Yang, R. (2013) · Chemical Communications · doi:10.1039/c3cc42962h · Cited by 51
Yu, Z., Shi, J., Li, J., Li, P., & Zhang, H. (2018) · Journal of Materials Chemistry B · doi:10.1039/c7tb03052e · Cited by 51
In Vivo Pharmacodynamic Imaging of Proteasome Inhibition
Kimbrel, E. A., Davis, T. N., Bradner, J. E., & Kung, A. L. (2009) · Molecular Imaging · doi:10.2310/7290.2009.00007 · Cited by 51
“In contrast, a significant portion of the bioluminescence emission spectrum of firefly luciferase is red-shifted beyond the hemoglobin absorbance spectrum and endogenous luminescence is low in animal tissues, thus facilitating in vivo imaging of deep tissues.(14,15) However, since the half-life of native firefly lucif…”
BackgroundChristian, N. A., Benencia, F., Milone, M. C., Li, G., Frail, P. R., Therien, M. J., Coukos, G., & Hammer, D. A. (2009) · Molecular Imaging and Biology · doi:10.1007/s11307-008-0184-x · Cited by 50
“Furthermore, the in vivo fluorescence intensity of NIR-DCs depends on cellular properties including the degree of TatNIR-emissive polymersome uptake, local cell density, and tissue depth [7].”
Bhaumik, S., DePuy, J., & Klimash, J. W. (2007) · Lab Animal · doi:10.1038/laban0907-40 · Cited by 50
“dtd" [ ]> The field of optical molecular imaging, the use of optical probes for tracking and reporting functional information on molecules, proteins and cells in vivo , is rapidly expandin”
BackgroundDesign of "smart" probes for optical imaging of apoptosis.
Huang, X., Lee, S., & Chen, X. S. (2011) · PubMed · Cited by 49
New Optical Molecular Imaging Systems
Qin, C., Zhu, S., & Tian, J. (2010) · Current Pharmaceutical Biotechnology · doi:10.2174/138920110792246519 · Cited by 49
“[30], the authors compared fluorescence and bioluminescence imaging performance quantitatively on an IVIS Imaging System 100 Series (Xenogen CorporationCaliper, Alameda, CA, USA).”
MethodRadiative transfer of luminescence light in biological tissue
Klose, A. D. (2009) · Springer eBooks · doi:10.1007/978-3-540-74276-0_6 · Cited by 49
Molecularly generated light and its biomedical applications
Ran, C., & Pu, K. (2023) · Angewandte Chemie International Edition · doi:10.1002/anie.202314468 · Cited by 48
The dynamic process of mRNA delivery by lipid nanoparticles in vivo
Ma, R., Li, Y., Wei, Y., Zhou, J., Ma, J., Zhang, M., Tu, J., Jiang, J., Xie, S., Tan, W., et al. (2024) · Nano Today · doi:10.1016/j.nantod.2024.102325 · Cited by 47
Studebaker, A. W., Hutzen, B. J., Pierson, C. R., Russell, S. J., Galanis, E., & Raffel, C. (2012) · Neuro-Oncology · doi:10.1093/neuonc/nor231 · Cited by 48
“This setting was chosen because it is substantially higher than the documented background auto-luminescence of a nude mouse (1000 photons/s/cm(2)/sr).(20) Using this technique to evaluate dissemination, we determined our success rate to be 83.”
MethodParallel Screening for Rapid Identification of Orthogonal Bioluminescent Tools
Rathbun, C. M., Porterfield, W., Jones, K. A., Sagoe, M. J., Reyes, M. R., Hua, C. T., & Prescher, J. A. (2017) · ACS Central Science · doi:10.1021/acscentsci.7b00394 · Cited by 46
Kindermann, M., Roschitzki‐Voser, H., Caglič, D., Repnik, U., Miniejew, C., Mittl, P. R. E., Kosec, G., Grütter, M. G., Turk, B., & Wendt, K. U. (2010) · Chemistry & Biology · doi:10.1016/j.chembiol.2010.07.011 · Cited by 45
“Even though product accumulation in fluorescent assays generally results in higher intensities than for bioluminescent readouts, more sensitive signals are achieved in bioluminescence due to the very low background levels (Troy et al., 2004).”
BackgroundRecent Advances in Small-Animal Cardiovascular Imaging
Tsui, B. M. W., & Kraitchman, D. L. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.058479 · Cited by 45
“Although the BLI signal tends to be lower than fluorescent signals, the lack of background luminescence signal, compared with native tissue fluorescence, provides a slight advantage to in vivo BLI (18).”
Reevaluation of the efficacy of favipiravir against rabies virus using in vivo imaging analysis
Yamada, K., Noguchi, K., Kimitsuki, K., Kaimori, R., Saito, N., Komeno, T., Nakajima, N., Furuta, Y., & Nishizono, A. (2019) · Antiviral Research · doi:10.1016/j.antiviral.2019.104641 · Cited by 45
Miao, Z., Ren, G., Liu, H., Jiang, L., & Cheng, Z. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3432738 · Cited by 44
“Optical molecular probes with high sensitivity, stability, fast targeting, and rapid clearance could be prepared.(17,24,25) Furthermore, optical imaging has very high resolution and”
Making the Brain Glow: In Vivo Bioluminescence Imaging to Study Neurodegeneration
Hochgräfe, K., & Mandelkow, E. (2012) · Molecular Neurobiology · doi:10.1007/s12035-012-8379-1 · Cited by 43
“Especially BLI turned out to be a powerful technique in whole-body imaging of small animals because it is extremely sensitive, does not require excitation, and provides extraordinary signal-to-background ratios due to the absence of self-luminous tissues in mammals [5].”
BackgroundFactors Affecting Residence Time of Mesenchymal Stromal Cells (MSC) Injected into the Myocardium
Westrich, J. R., Yaeger, P., He, C., Stewart, J., Chen, R. E., Seleznik, G. M., Larson, S. P., Wentworth, B. M., O'Callaghan, M. G., Wadsworth, S., et al. (2010) · Cell Transplantation · doi:10.3727/096368910x494911 · Cited by 43
“plicable fluorescent signal, because of its higher signal Luc+ MSC from Lewis rats were called MSCL, and Luc+ to background ratio (41).”
BackgroundNoninvasive fluorescence imaging of small animals
Zelmer, A., & Ward, T. H. (2013) · Journal of Microscopy · doi:10.1111/jmi.12063 · Cited by 43
Lee, J., White, A. G., Rice, D. R., & Smith, B. D. (2013) · Chemical Communications · doi:10.1039/c3cc40630j · Cited by 43
Multimodality Radionuclide, Fluorescence, and Bioluminescence Small-Animal Imaging
Park, J. M., & Gambhir, S. S. (2005) · Proceedings of the IEEE · doi:10.1109/jproc.2005.844263 · Cited by 43
“of fluorescence are improved in the red to near-infrared ranges due to maximal light output that does not suffer from tissue absorption from hemoglobin and other red absorbing chromophores [58].”
BackgroundFollin-Arbelet, V. V., Hofgaard, P. O., Hauglin, H., Naderi, S., Sundan, A., Blomhoff, R., Bogen, B., & Blomhoff, H. K. (2011) · BMC Cancer · doi:10.1186/1471-2407-11-301 · Cited by 42
“Images were scaled with an excitation light correction factor [25] yielding normalized fluorescence efficiency (NFE) images for further processing.”
Rice, B. W., & Contag, C. H. (2009) · Nature Biotechnology · doi:10.1038/nbt0709-624 · Cited by 41
Self-citationBloquel, C., Trollet, C., Pradines, E., Séguin, J., Scherman, D., & Bureau, M. (2006) · BMC Biotechnology · doi:10.1186/1472-6750-6-16 · Cited by 41
“Luciferases are presently more sensitive than fluorescent reporters, thanks to a high quantum yield associated to a very low background level of luminescence [12,13].”
BackgroundZhang, C., Yan, Z., Arango, M. E., Painter, C. L., & Anderes, K. L. (2008) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-08-0897 · Cited by 41
Saban, M. R., Sferra, T. J., Davis, C. A., Simpson, C., Allen, A. M., Maier, J., Fowler, B., Knowlton, N. S., Birder, L. A., Wu, X., et al. (2010) · American Journal of Physiology-Renal Physiology · doi:10.1152/ajprenal.00352.2010 · Cited by 40
Exploiting fluorescein based drug conjugates for fluorescent monitoring in drug delivery
Bazylevich, A., Patsenker, L. D., & Gellerman, G. (2016) · Dyes and Pigments · doi:10.1016/j.dyepig.2016.11.057 · Cited by 39
Molecular Imaging with Bioconjugates in Mouse Models of Cancer
Mather, S. J. (2008) · Bioconjugate Chemistry · doi:10.1021/bc800401x · Cited by 40
Chemiluminescence resonance energy transfer in the luminol–CdTe quantum dots conjugates
Li, Z., Wang, Y., Zhang, G., Xu, W., & Han, Y. (2010) · Journal of Luminescence · doi:10.1016/j.jlumin.2010.01.013 · Cited by 39
Shi, C., Zhu, Y., Xie, Z., Qian, W., Hsieh, C., Nie, S., Su, Y., Zhau, H. E., & Chung, L. W. K. (2009) · Urology · doi:10.1016/j.urology.2009.01.023 · Cited by 39
Fukuchi, M., Izumi, H., Mori, H., Kiyama, M., Otsuka, S., Maki, S., Maehata, Y., Tabuchi, A., & Tsuda, M. (2017) · Scientific Reports · doi:10.1038/s41598-017-05297-x · Cited by 40
Noninvasive Visualization of Adenovirus Replication with a Fluorescent Reporter in the E3 Region
Ono, H. A., Le, L. P., Davydova, J., Gavrikova, T. A., & Yamamoto, M. (2005) · Cancer Research · doi:10.1158/0008-5472.can-05-1871 · Cited by 39
“Background subtraction was done in WinView/32 ( 8 ).”
MethodQi, S., Miao, Z., Liu, H., Xu, Y., Feng, Y., & Cheng, Z. (2012) · Bioconjugate Chemistry · doi:10.1021/bc200596a · Cited by 38
Toxin–antitoxin-stabilized reporter plasmids for biophotonic imaging of Group A streptococcus
Loh, J. M. S., & Proft, T. (2013) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-013-5200-7 · Cited by 38
“Bioluminescence is usually preferred over fluorescence as autofluorescence is generally far brighter than autoluminescence and therefore generates a lower signal/noise ratio (Troy et al. 2004).”
Minimizing near-infrared autofluorescence in preclinical imaging with diet and wavelength selection
Sun, Y., Zhong, X., & Dennis, A. M. (2023) · Journal of Biomedical Optics · doi:10.1117/1.jbo.28.9.094805 · Cited by 37
Multimodal imaging and treatment of bone metastasis
Kaijzel, E. L., Snoeks, T. J. A., Buijs, J. T., van der Pluijm, G., & Löwik, C. W. G. M. (2008) · Clinical & Experimental Metastasis · doi:10.1007/s10585-008-9217-8 · Cited by 37
“invasive BLI and FLI indicate that although fluorescent signals are generally brighter than bioluminescent signals, the latter show superior SNR especially in the green to red part in the spectrum resulting in a much higher sensitivity [23, 24].”
BackgroundChoi, S. H., Cho, H. R., Kim, H. S., Kim, Y. H., Kang, K. W., Kim, H., & Moon, W. K. (2011) · NMR in Biomedicine · doi:10.1002/nbm.1788 · Cited by 37
“imaging is seriously limited by spatial resolution and the penetration of light through optically opaque tissues, even in mice (28).”
BackgroundFluorescence imaging agents in cancerology
Paganin-Gioanni, A., Bellard, E., Paquereau, L., Ecochard, V., Golzio, M., & Teissié, J. (2010) · Radiology and Oncology · doi:10.2478/v10019-010-0031-y · Cited by 37
Yevtodiyenko, A., Bazhin, A. A., Khodakivskyi, P. V., Godinat, A., Budin, G., Maric, T., Pietramaggiori, G., Scherer, S. S., Kunchulia, M., Eppeldauer, G. P., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-22892-9 · Cited by 36
Metal-enhanced bioluminescence: An approach for monitoring biological luminescent processes
Eltzov, E., Prilutsky, D., Kushmaro, A., Marks, R. S., & Geddes, C. D. (2009) · Applied Physics Letters · doi:10.1063/1.3086283 · Cited by 36
Rapid Development of Analytical Methods for Evaluating Pandemic Vaccines: A Covid-19 Perspective
Baldwin, J., Piplani, S., Sakala, I. G., Honda‐Okubo, Y., Li, L., & Petrovsky, N. (2021) · Bioanalysis · doi:10.4155/bio-2021-0096 · Cited by 35
“A limitation of this method is that it requires animal protocol approval, is time consuming, uses specialized imaging equipment and if the reporter is fluorescence-based there may be issues with high auto fluorescent background from host tissue, whereas bioluminescent reporters can vary based on substrate kinetics and…”
MethodMurphy, C., Moloney, G. M., Hall, L. J., Quinlan, A., Faivre, É., Casey, P. G., Shanahan, F., Melgar, S., & Nally, K. (2010) · Clinical & Experimental Immunology · doi:10.1111/j.1365-2249.2010.04234.x · Cited by 35
“In addition, bioluminescence overcomes the problems commonly encountered with using fluorescent labels such as CFSE and GFP, namely the exponentially decreasing light intensity with tissue depth and the limited sensitivity and specificity as a result of endogenous tissue autofluorescence [31, 32].”
BackgroundChen, I.-H., Chen, Y., Liou, J.-H., Lai, J.-T., Hsu, C.-C., Wang, N., & Jan, J. (2019) · Materials Science and Engineering C · doi:10.1016/j.msec.2019.110101 · Cited by 35
Yuan, Z.-Q., Li, J., Liu, Y., Chen, W., Yang, S.-D., Zhang, C.-G., Zhu, W.-J., Zhou, X., Liu, C., & Zhang, X. (2015) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2015.07.022 · Cited by 35
Development of bioluminescent Salmonella strains for use in food safety
Karsi, A., Howe, K., Kirkpatrick, T. B., Wills, R. W., Bailey, R. H., & Lawrence, M. L. (2008) · BMC Microbiology · doi:10.1186/1471-2180-8-10 · Cited by 35
“Advantages of the bacterial luciferase reporter system include negligible background [23], no toxic or phenotypic effects from accumulation of signal [24], real-time detection, and no need for addition of an exogenous substrate.”
Backgroundvan Zyl, W. F., Deane, S. M., & Dicks, L. M. T. (2015) · Applied and Environmental Microbiology · doi:10.1128/aem.01247-15 · Cited by 34
“Furthermore, impairment of transcutaneous signals also could be explained by the inherent background signals generated by the autofluorescence of the animal diet intake (56).”
BackgroundYang, C., Hou, V. W., Girard, E. J., Nelson, L. Y., & Seibel, E. J. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.7.076014 · Cited by 34
McCormack, E., Micklem, D., Pindard, L.-E., Silden, E., Gallant, P., Belenkov, S., Lorens, J. B., & Gjertsen, B. T. (2007) · Molecular Imaging · doi:10.2310/7290.2007.00016 · Cited by 33
Dullin, C., Zientkowska, M., Napp, J., Missbach‐Guentner, J., Krell, H., Müller, F., Grabbe, E., Tietze, L. F., & Alves, F. (2009) · Molecular Imaging · doi:10.2310/7290.2009.00001 · Cited by 34
Labeling Human Mesenchymal Stem Cells with Fluorescent Contrast Agents: the Biological Impact
Boddington, S. E., Sutton, E. J., Henning, T. D., Nedopil, A. J., Sennino, B., Kim, A. E., & Daldrup-Link, H. E. (2010) · Molecular Imaging and Biology · doi:10.1007/s11307-010-0322-0 · Cited by 33
“Ferucarbotran is characterized by a mean diameter of 60 nm, a net negative charge, as well as r1 and r2 relaxivities of 25 and 151 mM s, respectively [5].”
BackgroundNapp, J., Mathejczyk, J. E., & Alves, F. (2011) · Pediatric Radiology · doi:10.1007/s00247-010-1907-0 · Cited by 33
“Already as few as ~500 cells can be reliably detected in vivo at specific anatomical sites [83].”
BackgroundUzair, U., Benza, D., Behrend, C. J., & Anker, J. N. (2019) · ACS Sensors · doi:10.1021/acssensors.9b00962 · Cited by 32
Chu, M., & Wu (2012) · International Journal of Nanomedicine · doi:10.2147/ijn.s30709 · Cited by 32
Bartkova, S., Kokotovic, B., & Dalsgaard, I. (2016) · Journal of Fish Diseases · doi:10.1111/jfd.12491 · Cited by 32
“In comparison with fluorescence reporters, luciferase proteins that exhibit bioluminescence show higher sensitivity, lower toxicity and faster response to changing environments (Burns et al. 2001; Troy et al. 2004).”
BackgroundMethodInfluentialHigh-Resolution Chemical Imaging through Tissue with an X-ray Scintillator Sensor
Chen, H., Patrick, A. L., Yang, Z., VanDerveer, D. G., & Anker, J. N. (2011) · Analytical Chemistry · doi:10.1021/ac200054v · Cited by 32
Hyperspectral imaging and spectral unmixing for improving whole-body fluorescence cryo-imaging
Wirth, D. J., Byrd, B. K., Meng, B., Strawbridge, R. R., Samkoe, K. S., & Davis, S. C. (2020) · Biomedical Optics Express · doi:10.1364/boe.410810 · Cited by 31
Liu, L., Mason, R. P., & Gimi, B. (2014) · Cancer Letters · doi:10.1016/j.canlet.2014.09.038 · Cited by 31
“Others have noted that the autofluorescence of mammalian tissue may compromise the ability to detect fluorescent reporter proteins, whereas there is essentially no autoluminescence permitting unambiguous detection of BLI [44].”
BackgroundMetastasis models: the green fluorescent revolution?
Paris, S., & Sesboüé, R. (2004) · Carcinogenesis · doi:10.1093/carcin/bgh219 · Cited by 31
Abd‐Elgaliel, W. R., Cruz‐Monserrate, Z., Logsdon, C. D., & Tung, C. (2011) · Molecular BioSystems · doi:10.1039/c1mb05215b · Cited by 29
Transport-theory-based stochastic image reconstruction of bioluminescent sources
Klose, A. D. (2007) · Journal of the Optical Society of America A · doi:10.1364/josaa.24.001601 · Cited by 29
“other alteration and selection mechanisms complying with criteria (2) and ( 3 ) could be adopted, e.g., principles of thermodynamical annealing as given by the method of simulated annealing.”
BackgroundMethodInfluentialShivak, D. J., MacKenzie, K. D., Watson, N. L., Pasternak, J. A., Jones, B. D., Wang, Y., DeVinney, R., Wilson, H. L., Surette, M. G., & White, A. P. (2016) · Applied and Environmental Microbiology · doi:10.1128/aem.01346-16 · Cited by 29
“, hemoglobin) makes detection difficult (55).”
Highly Sensitive Bioluminescent Probe for Thiol Detection in Living Cells
Hemmi, M., Ikeda, Y., Shindo, Y., Nakajima, T., Nishiyama, S., Oka, K., Sato, M., Hiruta, Y., Citterio, D., & Suzuki, K. A. O. (2018) · Chemistry - An Asian Journal · doi:10.1002/asia.201701774 · Cited by 29
Preclinical Models of Brain Metastases in Breast Cancer
Knier, N. N., Pellizzari, S., Zhou, J., Foster, P. J., & Parsyan, A. E. (2022) · Biomedicines · doi:10.3390/biomedicines10030667 · Cited by 28
“In FLI, the most commonly utilized reporter, GFP, is used to directly detect the labeled cells through an excitation by a light source without a substrate [86,87].”
BackgroundInfluentialChen, K.-W., Hsu, P., Huang, H.-L., Liu, H.-L., Lin, Y., Hsu, C.-Y., Lin, J., & Lin, Y.-H. (2022) · Pharmacological Research · doi:10.1016/j.phrs.2022.106532 · Cited by 28
Lymphatic vessel density and function in experimental bladder cancer
Saban, M. R., Towner, R. A., Smith, N., Abbott, A., Neeman, M., Davis, C. A., Simpson, C., Maier, J., Mémet, S., Wu, X., et al. (2007) · BMC Cancer · doi:10.1186/1471-2407-7-219 · Cited by 28
“Mice were fed a low-chlorophyll diet for 2 weeks to reduce auto-fluorescence in the intestinal region [27] and the abdominal hair was removed.”
MethodBogaards, A., Sterenborg, H. J. C. M., & Wilson, B. C. (2007) · Photodiagnosis and Photodynamic Therapy · doi:10.1016/j.pdpdt.2007.02.003 · Cited by 28
In vivo Monitoring of microRNA Biogenesis Using Reporter Gene Imaging
Oh, S. W., Hwang, D. W., & Lee, D. S. (2013) · Theranostics · doi:10.7150/thno.4580 · Cited by 28
“Despite these successes in vitro, in vivo application of fluorescence imaging faces with several inherent limitations such as a high background auto-fluorescence, or limited tissue penetration of the light in vivo [22].”
Hwang, E., Song, J., & Zhang, J. (2019) · Biosensors · doi:10.3390/bios9010042 · Cited by 28
“When the bioluminescent donor, typically an oxidative luciferase enzyme such as NLuc, e its bioluminescent energy, which excites the fluorescent acceptor and increases its emission [14,20],this is known as resonance energy transfer, and only occurs when the two proteins are within 10 nm (Figure 1).”
BackgroundInfluentialNomura, N., Nishihara, R., Nakajima, T., Kim, S. B., Iwasawa, N., Hiruta, Y., Nishiyama, S., Sato, M., Citterio, D., & Suzuki, K. A. O. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b00694 · Cited by 28
Greene, J. M., Dunaway, C. W., Bowers, S. D., Rude, B. J., Feugang, J. M., & Ryan, P. L. (2012) · Journal of Nutrition · doi:10.3945/jn.111.154823 · Cited by 28
Kovar, J. L., Volcheck, W. M., Chen, J., & Simpson, M. A. (2006) · Analytical Biochemistry · doi:10.1016/j.ab.2006.11.021 · Cited by 27
Borovjagin, A. V., McNally, L. R., Wang, M., Curiel, D. T., MacDougall, M. J., & Zinn, K. R. (2010) · Molecular Imaging · doi:10.2310/7290.2010.00003 · Cited by 27
Molecular imaging of stem cells
Gambhir (2009) · StemBook · doi:10.3824/stembook.1.49.1 · Cited by 27
Guo, C., Hu, J., Kao, L., Pan, D., Luo, K., Li, N., & Gu, Z. (2016) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.6b00093 · Cited by 27
Inoue, Y., Izawa, K., Yoshikawa, K., Yamada, H., Tojo, A., & Ohtomo, K. (2007) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-007-0583-2 · Cited by 26
“They were given an alfalfa-free diet (alfalfa-free CA-1; CLEA Japan, Tokyo, Japan) for at least 7 days before FLI to reduce autofluorescence from the intestine [18].”
Practical Guidance for Developing Small-Molecule Optical Probes for In Vivo Imaging
Ran, C., Mansfield, J. R., Bai, M., Viola, N. T., Mahajan, A., & Delikatny, E. J. (2023) · Molecular Imaging and Biology · doi:10.1007/s11307-023-01800-1 · Cited by 25
“The reason for this stems from the excitation photon flux, which can be > 10,000-fold of the detectable emission photon flux [66] (Fig.”
BackgroundWilmink, G. J., Opalenik, S. R., Beckham, J. T., Mackanos, M. A., Nanney, L. B., Contag, C. H., Davidson, J. M., & Jansen, D. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2992594 · Cited by 25
“In fact, studies have reported that as few as 200 cells can be detected at a depth of 2 cm in an in vivo mouse model.(37) Mouse dermis is roughly 300 m thick, so for this study bioluminescence techniques are well suited to measure the emission of light from the entire FEL-treated tissue zone.”
Intraoperative Imaging in Ovarian Cancer: Fact or Fiction?
Crane, L. M. A., van Oosten, M., Pleijhuis, R. G., Motekallemi, A., Dowdy, S. C., Cliby, W. A., van der Zee, A. G. J., & van Dam, G. M. (2011) · Molecular Imaging · doi:10.2310/7290.2011.00004 · Cited by 25
“In this respect, the use of near-infrared (NIR) fluorescent dyes (750–1,000 nm) is advantageous for in vivo imaging because surrounding tissues generally absorb little of the emitted signal and light in the NIR spectrum does not compete with fluorescence in the visible light spectrum.(26) Moreover, near-infrared fluor…”
BackgroundIntravital Fluorescence Excitation in Whole-Animal Optical Imaging
Nooshabadi, F., Yang, H., Bixler, J. N., Kong, Y., Cirillo, J. D., & Maitland, K. C. (2016) · PLoS ONE · doi:10.1371/journal.pone.0149932 · Cited by 25
Acha, V., Andrews, T., Huang, Q., Sardar, D. K., & Hornsby, P. J. (2009) · Springer eBooks · doi:10.1007/978-1-4419-0919-0_9 · Cited by 25
“required to obtain a fluorescence signal above background, but only 400 cells were required to obtain a bioluminescence signal above background ( Troy et al. 2004 ).”
BackgroundMagnetic resonance imaging of in vitro glioma cell invasion
Bernas, L. M., Foster, P. J., & Rutt, B. K. (2007) · Journal of neurosurgery · doi:10.3171/jns.2007.106.2.306 · Cited by 25
Optical imaging in biomedical research: guidelines and practical insights
Chu, T., Zheng, X., Manshian, B. B., & Soenen, S. J. (2025) · Health Nanotechnology · doi:10.1186/s44301-025-00004-6 · Cited by 25
“Fluorescence imaging can achieve detection limits in the picomolar to nanomolar range, making it suitable for detecting low-abundance targets [87].”
Orioka, M., Eguchi, M., Mizui, Y., Ikeda, Y., Sakama, A., Li, Q., Yoshimura, H., Ozawa, T., Citterio, D., & Hiruta, Y. (2022) · Bioconjugate Chemistry · doi:10.1021/acs.bioconjchem.2c00035 · Cited by 24
Tu, Y., Wan, L., Zhao, D., Bu, L., Dong, D., Yin, Z., Cheng, Z., & Shen, B. (2014) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-013-2596-3 · Cited by 24
Near-Infrared Optical Proteolytic Beacons for In Vivo Imaging of Matrix Metalloproteinase Activity
McIntyre, J. O., Scherer, R. L., & Matrisian, L. M. (2010) · Methods in molecular biology · doi:10.1007/978-1-60327-299-5_18 · Cited by 24
“This kind of diet has been reported by others to decrease autofluorescence in the intestinal region (8).”
BackgroundBioluminescence Imaging to Evaluate Infections and Host Response In Vivo
Contag, P. R. (2008) · Humana Press eBooks · doi:10.1007/978-1-59745-570-1_6 · Cited by 24
An optical imaging method to monitor stem cell migration in a model of immune-mediated arthritis
Sutton, E. J., Boddington, S. E., Nedopil, A. J., Henning, T. D., Demos, S. G., Baehner, F. L., Sennino, B., Lü, Y., & Daldrup-Link, H. E. (2009) · Optics Express · doi:10.1364/oe.17.024403 · Cited by 23
Sensitivity characterization of a time-domain fluorescence imager: eXplore Optix
Ma, G., Gallant, P., & McIntosh, L. M. (2007) · Applied Optics · doi:10.1364/ao.46.001650 · Cited by 23
Molecular Imaging Using Visible Light to Reveal Biological Changes in the Brain
Contag, C. H. (2006) · Neuroimaging Clinics of North America · doi:10.1016/j.nic.2006.08.002 · Cited by 23
Distinguished Photons: A Review of In Vivo Spectral Fluorescence Imaging in Small Animals
Mansfield, J. R. (2010) · Current Pharmaceutical Biotechnology · doi:10.2174/138920110792246474 · Cited by 22
Metadata
- Authors
- Troy, T., Jekic-McMullen, D., Sambucetti, L., & Rice, B.
- Corresponding author
- Troy, Tamara
- ORCID
- Sambucetti, Lidia
- Venue
- Molecular Imaging
- Publisher
- SAGE Publications
- Published
- 2004-01-01
- Volume
- 3
- Issue
- 1
- Pages
- 9-23
- ISSN
- 1535-3508 (ISSN-L)
- 1536-0121
- OpenAlex
- W2059614428
- Cited by
- 418
- References
- 30
- Citations by year
- 2026: 3 · 2025: 10 · 2024: 15 · 2023: 14 · 2022: 13 · 2021: 16 · 2020: 20 · 2019: 17 · 2018: 12 · 2017: 13 · 2016: 16 · 2015: 14 · 2014: 18 · 2013: 22 · 2012: 28
- FWCI
- 8.41
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- Molecular Imaging (publishedVersion)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › bioluminescence and chemiluminescence research
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Advanced Fluorescence Microscopy Techniques
- Keywords
- bioluminescence reporter, fluorescent reporter, detection sensitivity, optical molecular imaging, autofluorescence, signal-to-background ratio, radiance calibration, far-red fluorescence, near-infrared fluorescence, small animal imaging
- MeSH terms
- Adenocarcinoma, Animals, Diagnostic Imaging, Female, Fluorescence, Fluorescent Dyes, HeLa Cells, Humans, Luminescent Measurements, Luminescent Proteins, Male, Mice, Inbred Strains, Mice, Nude, Organic Chemicals, Prostatic Neoplasms, Sensitivity and Specificity, Models, Animal, Cell Line, Tumor, Mice, Optics and Photonics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.