Quantitative Comparison of the Sensitivity of Detection of Fluorescent and Bioluminescent Reporters in Animal Models
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
Bioluminescent and fluorescent reporters are finding increased use in optical molecular imaging in small animals. In the work presented here, issues related to the sensitivity of in vivo detection are examined for standard reporters. A high-sensitivity imaging system that can detect steady-state emission from both bioluminescent and fluorescent reporters is described. The instrument is absolutely calibrated so that animal images can be analyzed in physical units of radiance allowing more quantitative comparisons to be performed. Background emission from mouse tissue, called autoluminescence and autofluorescence, is measured and found to be an important limitation to detection sensitivity of reporters. Measurements of dual-labeled (bioluminescent/fluorescent) reporter systems, including PC-3M-luc/DsRed2-1 and HeLa-luc/PKH26, are shown. The results indicate that although fluorescent signals are generally brighter than bioluminescent signals, the very low autoluminescent levels usually results in superior signal to background ratios for bioluminescent imaging, particularly compared with fluorescent imaging in the green to red part of the spectrum. Fluorescence detection sensitivity improves in the far-red to near-infrared, provided the animals are fed a low-chlorophyll diet to reduce autofluorescence in the intestinal region. The use of blue-shifted excitation filters is explored as a method to subtract out tissue autofluorescence and improve the sensitivity of fluorescent imaging.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Wave Propagation and Scattering in Random Media
(1978) · Elsevier eBooks · doi:10.1016/c2013-0-10906-3 · Cited by 4,709
A review of the optical properties of biological tissues
Cheong, W. F., Prahl, S. A., & Welch, A. J. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64354 · Cited by 2,530 · cited 1×
“5 cm 1 for wavelengths between 600 and 1000 nm [25].”
BackgroundWater-Soluble Quantum Dots for Multiphoton Fluorescence Imaging in Vivo
Larson, D. R., Zipfel, W. R., Williams, R. M., Clark, S. W., Bruchez, M. P., Wise, F. W., & Webb, W. W. (2003) · Science · doi:10.1126/science.1083780 · Cited by 2,286
In vivo imaging of tumors with protease-activated near-infrared fluorescent probes
Weissleder, R., Tung, C.-H., Mahmood, U., & Bogdanov, A. (1999) · Nature Biotechnology · doi:10.1038/7933 · Cited by 1,591
Åkerman, M. E., Chan, W. C. W., Laakkonen, P., Bhatia, S. N., & Ruoslahti, E. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.152463399 · Cited by 1,437 · cited 1×
“probes such as quantum dots are also beginning to find biological applications [15–17].”
BackgroundBoundary conditions for the diffusion equation in radiative transfer
Haskell, R. C., Svaasand, L. O., Tsay, T.-T., Feng, T.-C., Tromberg, B. J., & McAdams, M. S. (1994) · Journal of the Optical Society of America A · doi:10.1364/josaa.11.002727 · Cited by 1,138 · cited 1×
“bounded medium requires treatment of the tissue–air boundary conditions [27].”
BackgroundFluorescence molecular tomography resolves protease activity in vivo
Ntziachristos, V., Tung, C.-H., Bremer, C., & Weissleder, R. (2002) · Nature Medicine · doi:10.1038/nm729 · Cited by 827 · cited 1×
“For applications such as tumor visualization, target-activated probes have been used [9,10].”
MethodPhotonic detection of bacterial pathogens in living hosts
Contag, C. H., Contag, P. R., Mullins, J. I., Spilman, S. D., Stevenson, D. K., & Benaron, D. A. (1995) · Molecular Microbiology · doi:10.1111/j.1365-2958.1995.mmi_18040593.x · Cited by 652 · cited 1×
“This technology has a large range of applications, including study of infectious disease, oncology, pharmacokinetics and pharmacodynamics, toxicology, and gene expression in light-producing transgenic animals [1–12].”
BackgroundSelection of Quantum Dot Wavelengths for Biomedical Assays and Imaging
Lim, Y. T., Kim, S., Nakayama, A., Stott, N. E., Bawendi, M. G., & Frangioni, J. V. (2003) · Molecular Imaging · doi:10.1162/15353500200302163 · Cited by 559
Optical imaging of Renilla luciferase reporter gene expression in living mice
Bhaumik, S., & Gambhir, S. S. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.012611099 · Cited by 536 · cited 1×
“This technology has a large range of applications, including study of infectious disease, oncology, pharmacokinetics and pharmacodynamics, toxicology, and gene expression in light-producing transgenic animals [1–12].”
Background
Cited by
Items 201–300 of 470
Molecular imaging of small animals with fluorescent proteins: From projection to multimodality
Yang, X., Gong, H., Fu, J., Quan, G., Huang, C., & Luo, Q. (2011) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2011.09.002 · Cited by 22
Bioluminescence Imaging of Angiogenesis in a Murine Orthotopic Pancreatic Cancer Model
Angst, E., Chen, M. F., Mojadidi, M., Hines, O. J., Reber, H. A., & Eibl, G. (2010) · Molecular Imaging and Biology · doi:10.1007/s11307-010-0310-4 · Cited by 22
“In contrast to fluorescence, bioluminescence is more sensitive for imaging and lacks the background from autofluorescence [21].”
BackgroundNon-Invasive Monitoring of Streptococcus pyogenes Vaccine Efficacy Using Biophotonic Imaging
Alam, F. M., Bateman, C., Turner, C. E., Wiles, S., & Sriskandan, S. (2013) · PLoS ONE · doi:10.1371/journal.pone.0082123 · Cited by 21
“The correlation of bioluminescent flux (photons s-1) with bacterial counts in vivo was not perfect however, and is known to be affected by a range of factors including bacterial growth phase, tissue oxygen tension, use of anaesthetic drugs, body tissue density, and fur colour [28].”
BackgroundGerstenhaber, J. A., Barone, F. C., Marcinkiewicz, C., Li, J., Shiloh, A., Sternberg, M., Lelkes, P. I., & Feuerstein, G. (2017) · International Journal of Nanomedicine · doi:10.2147/ijn.s146946 · Cited by 21
“5” (695–770 nm) with similar imaging settings as above, and subtracted from the foreground as modified from IVIS 50 protocol to compensate for the large stokes shift of the F-NDP NV .(12) This correction was used for a simplified spectral un-mixing: a ratio of auto-fluorescence between the channel of interest and blue…”
MethodHall, M. S., Decker, J. T., & Shea, L. D. (2020) · Biomaterials · doi:10.1016/j.biomaterials.2020.120189 · Cited by 22
“of transcription factor activity, because the low background imparts a high signal to noise ratio (62, 63).”
BackgroundWu, Y., Li, H., Yan, Y., Wang, K., Cheng, Y., Li, Y., Zhu, X., Xie, J., & Sun, X. (2020) · International Journal of Nanomedicine · doi:10.2147/ijn.s244172 · Cited by 21
Increased bioassay sensitivity of bioactive molecule discovery using metal-enhanced bioluminescence
Golberg, K., Elbaz, A., McNeil, R., Kushmaro, A., Geddes, C. D., & Marks, R. S. (2014) · Journal of Nanoparticle Research · doi:10.1007/s11051-014-2770-y · Cited by 21
“signals, bioluminescent signals show lower illumination intensity (Troy et al. 2004).”
BackgroundKimball, K. J., Rivera, Á. A., Zinn, K. R., Icyuz, M., Saini, V., Li, J., Zhu, Z. B., Siegal, G. P., Douglas, J. T., Curiel, D. T., et al. (2009) · Molecular Imaging · doi:10.2310/7290.2009.00025 · Cited by 21
Fukuchi, M., Saito, R., Maki, S., Hagiwara, N., Nakajima, Y., Mitazaki, S., Izumi, H., & Mori, H. (2020) · Molecular Brain · doi:10.1186/s13041-020-00665-7 · Cited by 21
Stephan, D. P., Slabber, C., George, G. M., Ninov, V., Francis, K. P., & Burger, J. T. (2011) · Plant Methods · doi:10.1186/1746-4811-7-25 · Cited by 21
“Discussion The IVIS Lumina II optical imaging system, used predominantly for non-invasive biophotonic imaging in rodent animal models [32,33], proved to be an ideal tool for the quantitative analysis and spatial distribution of GFP expression in leaves of N.”
MethodIn vivo dynamic imaging of intestinal motions using diet‐related autofluorescence
Kwon, S., Davies-Venn, C., & Sevick-Muraca, E. M. (2012) · Neurogastroenterology & Motility · doi:10.1111/j.1365-2982.2012.01886.x · Cited by 20
A Multi-Camera System for Bioluminescence Tomography in Preclinical Oncology Research
Lewis, M. A., Richer, E., Slavine, N., Kodibagkar, V. D., Soesbe, T. C., Antich, P. P., & Mason, R. P. (2013) · Diagnostics · doi:10.3390/diagnostics3030325 · Cited by 20
“[62].”
Shan, L., Wang, S., Korotcov, A. V., Sridhar, R., & Wang, P. C. (2008) · PubMed · Cited by 20
A high-sensitivity small animal SPECT system
Mitchell, G. S., & Cherry, S. R. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/5/013 · Cited by 20
“For example, the first commercial optical imaging system provided only a single projection view of the animal (Rice et al 2001, Troy et al 2004).”
BackgroundTechnical considerations in longitudinal multispectral small animal molecular imaging
Bouchard, M. B., MacLaurin, S. A., Dwyer, P. J., Mansfield, J. R., Levenson, R., & Krucker, T. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2799188 · Cited by 20
“Herein, the term “skin autofluorescence” is used to describe fluorescence emitted from endogenous murine fluorophores present in the skin, and “chlorophyll fluorescence” is used to describe fluorescence associated with the digested derivatives of standard alfalfa-containing rodent chow, of which chlorophyll and its de…”
BackgroundPreclinical whole body time domain fluorescence lifetime multiplexing of fluorescent proteins
Rice, W. L., & Kumar, A. T. N. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.4.046005 · Cited by 20
“Although CW fluorescence imaging has been applied to detect FPs in whole mice,(9) the presence of tissue AF limits the minimum detectable levels of fluorescence, thereby limiting the sensitivity of the technique for whole body imaging.(3) In addition, these measurements necessitate very high laser powers [∼50 mW (Refs.”
BackgroundBiosensors Based on Inorganic Composite Fluorescent Hydrogels
Sokolov, P. M., Samokhvalov, P. S., Sukhanova, A. V., & Nabiev, I. R. (2023) · Nanomaterials · doi:10.3390/nano13111748 · Cited by 19
“Fluorescence detection is the most sensitive of all optical detection methods [18,19], provided that the optimal type of the fluorescence label, e.”
Recent advancements in the sensors for food analysis to detect gluten: A mini-review [2019–2023]
Jain, S., Lamba, B. Y., & Dubey, S. K. (2024) · Food Chemistry · doi:10.1016/j.foodchem.2024.139204 · Cited by 19
Studying Triple Negative Breast Cancer Using Orthotopic Breast Cancer Model
Cheng, R. Y. S., Patel, N. L., Back, T. C., Basudhar, D., Somasundaram, V., Kalen, J. D., Wink, D. A., & Ridnour, L. A. (2020) · Journal of Visualized Experiments · doi:10.3791/60316 · Cited by 19
Lee, J., Gonçalves, A. C., Smith, B. A., Palumbo, R., White, A. G., & Smith, B. D. (2011) · Australian Journal of Chemistry · doi:10.1071/ch11038 · Cited by 19
Optical molecular imaging in drug discovery and clinical development
Bednár̂, B., Zhang, G., Williams, D. L., Jr., Hargreaves, R. J., & Sur, C. (2007) · Expert Opinion on Drug Discovery · doi:10.1517/17460441.2.1.65 · Cited by 19
“These bioluminescence imaging systems have been shown (so far) to be advantageous over the second group of the endogenous probes based on fluorescent proteins represented mainly by green fluorescent protein (GFP) and DsRed fluorescent proteins [14-16].”
BackgroundMethodLong-term single cell bioluminescence imaging with C-3 position protected coelenterazine analogues
Mizui, Y., Eguchi, M., Tanaka, M., Ikeda, Y., Yoshimura, H., Ozawa, T., Citterio, D., & Hiruta, Y. (2020) · Organic & Biomolecular Chemistry · doi:10.1039/d0ob02020f · Cited by 18
Methods for Detecting PER2:LUCIFERASE Bioluminescence Rhythms in Freely Moving Mice
Martin-Burgos, B., Wang, W., William, I., Tir, S., Mohammad, I., Javed, R., Smith, S., Cui, Y., Arzavala, J., Mora, D., et al. (2021) · Journal of Biological Rhythms · doi:10.1177/07487304211062829 · Cited by 18
“Bioluminescence has several advantages compared to fluorescence for long-term studies, including low phototoxicity and very low background noise (Troy et al., 2004).”
BackgroundLuminescence and fluorescence of essential oils. Fluorescence imaging in vivo of wild chamomile oil
Boschi, F., Fontanella, M. M., Calderan, L., & Sbarbati, A. (2011) · European Journal of Histochemistry · doi:10.4081/ejh.2011.e18 · Cited by 18
An Optimized Triple Modality Reporter for Quantitative In Vivo Tumor Imaging and Therapy Evaluation
Levin, R. A., Felsen, C. N., Yang, J. Y., Lin, J. Y., Whitney, M. A., Nguyen, Q. T., & Tsien, R. Y. (2014) · PLoS ONE · doi:10.1371/journal.pone.0097415 · Cited by 18
“autoluminescence in mammalian tissues [7].”
BackgroundNovel chemiluminescent nanosystem for highly sensitive detection of hydrogen peroxide in vivo
Park, J. S., Kim, S., Choi, C., Park, K., & Park, K. (2023) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2023.134261 · Cited by 17
Ramji, R., Cheong, C. F., Hirata, H., Rahman, A. R. A., & Lim, C. T. (2014) · Small · doi:10.1002/smll.201401674 · Cited by 17
Distinguished Photons: Increased Contrast with Multispectral in Vivo Fluorescence Imaging
Mansfield, J. R., Hoyt, C. C., Miller, P. J., & Levenson, R. M. (2005) · BioTechniques · doi:10.2144/000112093 · Cited by 17
Katsuta, E., Oshi, M., Rashid, O. M., & Takabe, K. (2018) · Journal of Visualized Experiments · doi:10.3791/57849 · Cited by 17
Reporter systems for in vivo tracking of lactic acid bacteria in animal model studies
van Zyl, W. F., Deane, S. M., & Dicks, L. M. T. (2015) · Gut Microbes · doi:10.1080/19490976.2015.1086058 · Cited by 18
“Generally, the absorption of wavelengths longer than 600 nm (red part of the spectrum) by endogenously produced fluorophores is reduced, allowing the propagation of red light through several centimeters of tissue.(56,57) In many applications, the use of fluorescent proteins such as DsRed is hampered by a slow maturati…”
BackgroundKwon, S., & Sevick-Muraca, E. M. (2017) · Contrast Media & Molecular Imaging · doi:10.1155/2017/7659242 · Cited by 16
“5 and Alexa680, or fluorescent proteins to reduce unwanted background fluorescent signals [4, 5].”
InfluentialBogdanov, A. A., Jr., Lin, C. P., & Kang, H.-W. (2007) · Pharmaceutical Research · doi:10.1007/s11095-006-9219-7 · Cited by 16
“Fluorescence was quantitated by using ROI method applied to Live Image (Xenogen) software-generated radiance maps (17).”
MethodQuantitative surface radiance mapping using multiview images of light-emitting turbid media
Guggenheim, J. A., Basevi, H. R. A., Styles, I. B., Frampton, J., & Dehghani, H. (2013) · Journal of the Optical Society of America A · doi:10.1364/josaa.30.002572 · Cited by 16
In Vivo Stem Cell Imaging Principles and Applications
Hong, S., Lee, D.-S., Bae, G.-W., Jeon, J., Kim, H. K., Rhee, S., & Jung, K. O. (2023) · International Journal of Stem Cells · doi:10.15283/ijsc23045 · Cited by 15
“However, fluorescence imaging is limited due to low signal-to-back-ground ratios and autofluorescence (53, 58, 59).”
BackgroundSandelius, Å., Naseer, H., Lindqvist, J., Wilson, A., & Henderson, N. (2024) · Bioanalysis · doi:10.1080/17576180.2024.2360361 · Cited by 15
Orthogonal Bioluminescent Probes from Disubstituted Luciferins
Williams, S. J., Hwang, C. S., & Prescher, J. A. (2021) · Biochemistry · doi:10.1021/acs.biochem.0c00894 · Cited by 15
The effects of low level laser therapy on both HIV‐1 infected and uninfected TZM‐bl cells
Lugongolo, M. Y., Manoto, S. L., Ombinda-Lemboumba, S. S., Mâaza, M., & Mthunzi-Kufa, P. T. (2017) · Journal of Biophotonics · doi:10.1002/jbio.201600217 · Cited by 15
A new general mathematical framework for bioluminescence tomography
Cheng, X., Gong, R., & Han, W. (2007) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2007.08.026 · Cited by 15
“The goal of BLT is to quantitatively reconstruct a bioluminescent source distribution within a small animal from optical signals on the surface of the animal body.”
BackgroundVanhoffelen, E., Vermoesen, L., Michiels, L., Lagrou, K., Reséndiz-Sharpe, A., & Velde, G. V. (2024) · Virulence · doi:10.1080/21505594.2024.2327883 · Cited by 14
“However, we anticipate fluorescence imaging (FLI) to have a lower signal-to-noise ratio, which could decrease the sensitivity in distinguishing cryptococcal burdens compared to BLI [36].”
Au, J. T., González, L., Chen, C., Serganova, I. S., & Fong, Y. (2012) · Annals of Surgical Oncology · doi:10.1245/s10434-012-2313-7 · Cited by 14
Behrooz, A., Kuo, C., Xu, H., & Rice, B. W. (2013) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.7.076010 · Cited by 14
Self-citationMcCloskey, M. C., Shaheen, S. K., Rabago, L. M., Hulverson, M. A., Choi, R., Barrett, L. K., & Arnold, S. L. M. (2019) · Scientific Reports · doi:10.1038/s41598-019-49729-2 · Cited by 14
Ikeda, Y., Tanaka, M., Nishihara, R., Hiruta, Y., Citterio, D., Suzuki, K. A. O., & Niwa, K. (2020) · Journal of Photochemistry and Photobiology A Chemistry · doi:10.1016/j.jphotochem.2020.112459 · Cited by 14
Mhlongo, N. Z., Ebenhan, T., Driver, C. H. S., Maguire, G. E. M., Kruger, H. G., Govender, T., & Naicker, T. (2020) · Organic & Biomolecular Chemistry · doi:10.1039/d0ob01415j · Cited by 14
A dual-luciferase bioluminescence system for the assessment of cellular therapies
Chavez, A. G. T., McKenna, M. K., Balasubramanian, K., Riffle, L. A., Patel, N. L., Kalen, J. D., Croix, B. S., Leen, A. M., & Bajgain, P. (2024) · Molecular Therapy Oncology · doi:10.1016/j.omton.2024.200763 · Cited by 14
A homotopy method for bioluminescence tomography
Gong, R., Cheng, X., & Han, W. (2017) · Inverse Problems in Science and Engineering · doi:10.1080/17415977.2017.1310854 · Cited by 13
Bioluminescence Imaging with Functional Amyloid Reservoirs in Alzheimer’s Disease Models
Yang, J., Ding, W., Zhu, B., Zhen, S. Y., Kuang, S., Yang, J., Zhang, C. M., Wang, P., Yang, F., Yang, L., et al. (2023) · Analytical Chemistry · doi:10.1021/acs.analchem.3c02358 · Cited by 13
Imaging technologies and basic considerations for welfare of laboratory rodents
Tremoleda, J. L., & Sosabowski, J. K. (2015) · Lab Animal · doi:10.1038/laban.665 · Cited by 13
Brozek-Pluska, B., Kopec, M., & Surmacki, J. M. (2018) · Journal of Spectroscopy · doi:10.1155/2018/4893274 · Cited by 13
Ratiometric Fluorescence Monitoring of Antibody-Guided Drug Delivery to Cancer Cells
Poplinger, D., Bokan, M., Hesin, A., Thankarajan, E., Tuchinsky, H., Gellerman, G., & Patsenker, L. D. (2021) · Bioconjugate Chemistry · doi:10.1021/acs.bioconjchem.1c00205 · Cited by 13
Elumalai, M., Vimalraj, S., Chandirasekar, S., Ezhumalai, N., Kasthuri, J., & Rajendiran, N. (2022) · Langmuir · doi:10.1021/acs.langmuir.2c00713 · Cited by 13
Göröcs, Z. S., Rivenson, Y., Koydemir, H. C., Tseng, D. K., Troy, T. L., Demas, V., & Özcan, A. (2016) · ACS Nano · doi:10.1021/acsnano.6b05129 · Cited by 13
Self-citationMacromolecular assembly of bioluminescent protein nanoparticles for enhanced imaging
Li, E., Brennan, C. K., Ramirez, A., Tucker, J. A., Butkovich, N., Meli, V. S., Ionkina, A. A., Nelson, E. L., Prescher, J. A., & Wang, S. (2022) · Materials Today Bio · doi:10.1016/j.mtbio.2022.100455 · Cited by 12
“Furthermore, the 150-Watt quartz halogen lamp in the IVIS imager [63] as the fluorescence excitation light source might not be powerful enough for AF-E2 for long-term in vivo imaging.”
Fang, L., Gu, W., Li, R., Chen, C., Cai, S., Luozhong, S., Chen, M., Hsu, A., Tsai, Y.-C., Londhe, K., et al. (2024) · ACS Nano · doi:10.1021/acsnano.4c07530 · Cited by 12
Mitchell, G. S., Lloyd, P. N. T., & Cherry, S. R. (2020) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ab7502 · Cited by 12
Lugongolo, M. Y., Manoto, S. L., Ombinda-Lemboumba, S. S., Mâaza, M., & Mthunzi-Kufa, P. T. (2020) · Biomedical Journal · doi:10.1016/j.bj.2020.05.022 · Cited by 12
“The little luminescence detected in uninfected cells could be attributed to the autoluminescence which is present at very low levels in most mammalian cells [44].”
BackgroundZhao, C., Tian, M., & Zhang, H. (2010) · The Open Nuclear Medicine Journal · doi:10.2174/1876388x01002010171 · Cited by 12
“However, due to the very low tissue penetrance (1–2 mm) of the excitation and emission wavelengths of GFP which are within the range of 500 nm and unacceptable amount of background signal caused by extrinsic excitation light, called autofluorescence, GFP reporter cannot be used to reliably track in vivo characteristic…”
BackgroundImaging Mesenchymal Stem Cell Migration and the Implications for Stem Cell-Based Cancer Therapies
Wang, H., & Chen, X. S. (2008) · Future Oncology · doi:10.2217/14796694.4.5.623 · Cited by 12
In Vivo Imaging in Humanized Mice
Masuda, H., Okano, H. J., Maruyama, T., Yoshimura, Y., Okano, H., & Matsuzaki, Y. (2008) · Current topics in microbiology and immunology · doi:10.1007/978-3-540-75647-7_12 · Cited by 12
“In contrast, FLI requires an external light source to stimulate the emission of light from the probe, and the light source could also generate bright background signals arising from the animal’s intrinsic autofluorescence [26, 44, 50 ].”
BackgroundBioluminescence measurements in mice using a skin window
Huang, Q., Acha, V., Yow, R. M., Schneider, E. C., Sardar, D. K., & Hornsby, P. J. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2795567 · Cited by 12
“Tissues also scatter light and fluoresce to various extents.(35) When accurate measurement of light is required in whole animals, any avoidable passage of light through tissues prior to measurement is undesirable.”
BackgroundOliveira, F. A., Nucci, M. P., Mamani, J. B., Alves, A. H., Rego, G. N. A., Kondo, A. T., Hamerschlak, N., Junqueira, M. D. S., de Souza, L. E. B., & Gamarra, L. F. (2021) · Biomedicines · doi:10.3390/biomedicines9070752 · Cited by 11
“This strategy of previous treatment with 5-FU potentialized cell tracking, whereas to evaluate the cell tracking in vivo in the non-invasive way it is necessary to administer a great number of cells [40,41].”
MethodCellular Immunogenicity of Novel Gene Immunogens in Mice Monitored by in Vivo Imaging
Starodubova, E. S., Krotova, O., Hallengärd, D., Kuzmenko, Y. V., Engström, G., Legzdina, D., Latyshev, O., Eliseeva, O., Maltais, A.-K., Tunitskaya, V. L., et al. (2012) · Molecular Imaging · doi:10.2310/7290.2012.00011 · Cited by 11
Novel Bioluminescent Activatable Reporter for Src Tyrosine Kinase Activity in Living Mice
Leng, W., Li, D., Chen, L., Xia, H., Tang, Q., Chen, B., Gong, Q., Gao, F., & Bi, F. (2016) · Theranostics · doi:10.7150/thno.14306 · Cited by 11
“In particular, bioluminescence can circumvent cell and tissue autoluminescence resulting in a better signal to noise ratio [24].”
RetractedAndo, Y., Sakurai, T., Koida, K., Tei, H., Hida, A., Nakao, K., Natsume, M., & Numano, R. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.000963 · Cited by 11
Mahoney, D. E., Chalise, P., Rahman, F. K., & Pierce, J. D. (2022) · Cancers · doi:10.3390/cancers14123022 · Cited by 10
“Black mice have substantial lower bioluminescent signals as compared to white, shaved, or nude mice [67].”
BackgroundFaley, S. L., Takahashi, K., Crooke, C. E., Beckham, J. T., Tomemori, T., Shappell, S. B., Jansen, D., & Takahashi, T. (2007) · Molecular Imaging · doi:10.2310/7290.2007.00029 · Cited by 10
“In addition, recent studies using the tumor cells expressing both GFP and luciferase proteins have shown that BLI is a more sensitive method than fluorescence imaging because its background is minimal.(15,28) We think it is unlikely that the GFP signal is reduced by its fusion to luciferase because fluorescenceactivat…”
Bioluminescence Imaging of Cancer Therapy
Sekar, T. V., & Paulmurugan, R. (2014) · Elsevier eBooks · doi:10.1016/b978-0-12-407722-5.00006-2 · Cited by 10
Shining a Light on Intestinal Traffic
Murphy, C., Nally, K., Shanahan, F., & Melgar, S. (2011) · Clinical and Developmental Immunology · doi:10.1155/2012/808157 · Cited by 10
“The pitfalls with using fluorescent labels, such as CFSE and GFP, include signal loss due to label dilution upon cell division and limited sensitivity and specificity due to endogenous tissue autofluorescence and light scattering and absorption [20].”
Imaging Intestinal ROS in Homeostatic Conditions Using L-012
Conroy, E., & Aviello, G. (2019) · Methods in molecular biology · doi:10.1007/978-1-4939-9424-3_19 · Cited by 10
Engineering of monobody conjugates for human EphA2-specific optical imaging
Kim, M., Yoon, H. S., Park, S., Kim, D., Pyo, A., Kim, H. S., Min, J., & Hong, Y. (2017) · PLoS ONE · doi:10.1371/journal.pone.0180786 · Cited by 10
Jones, E. J., Parker, A., Juodeikis, R., Blackshaw, L. A., Brion, A., & Carding, S. R. (2025) · Extracellular Vesicles and Circulating Nucleic Acids · doi:10.20517/evcna.2025.32 · Cited by 9
A telescopic microscope equipped with a quanta image sensor for live-cell bioluminescence imaging
Ma, R., Santino, L. M., Chobola, T., Armbrust, N., Geilenkeuser, J., Sukumaran, S., Jing, Z., Levkina, A., Ridderbeek, K., Peng, T., et al. (2025) · Nature Methods · doi:10.1038/s41592-025-02694-3 · Cited by 9
“Despite advancements in proteins and substrates 8,14–17 , enzymatic turnover inevitably restricts bioluminescence photon emission to rates orders of magnitude lower than possible by photon absorption and emission in fluorophores 10,18,19 .”
Semi-automated Image Processing for Preclinical Bioluminescent Imaging
Slavine, N., & McColl, R. W. (2015) · Journal of Applied Bioinformatics & Computational Biology · doi:10.4172/2329-9533.1000114 · Cited by 9
“We fabricated phantoms and light sources following procedures from published articles [21-23], but used a novel practical method to calibrate the phantom [24].”
MethodLehmann, S., García‐Garayoa, E., Blanc, A., Keist, R., Schibli, R., & Rudin, M. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.110.082412 · Cited by 9
Ferritin as a novel reporter gene for photoacoustic molecular imaging
Ha, S. H., Carson, A. R., & Kim, K. (2012) · Cytometry Part A · doi:10.1002/cyto.a.22160 · Cited by 9
“Despite their wide use and theoretical potential of in-vivo imaging, both of these reporter genes are challenging to apply in vivo because of strong light-scattering, low signal-to-background ratios, autofluorescence, and poor tissue penetration (33).”
BackgroundGreene, J. M., Dunaway, C. W., Bowers, S. D., Rude, B. J., Feugang, J. M., & Ryan, P. L. (2011) · Reproductive Biology and Endocrinology · doi:10.1186/1477-7827-9-51 · Cited by 9
“9 cm) was drawn and placed on the ventral neck region to obtain a background measurement for each animal to correct for any autoluminescence that may originate from sources such as chemiluminescent metabolic processes [17].”
MethodTri-modality small animal imaging system
Kundu, B. K., Stolin, A., Pole, J., Baumgart, L. A., Fontaine, M., Wojcik, R., Kross, B., Zorn, C., Majewski, S., & Williams, M. B. (2006) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2005.862970 · Cited by 9
Szczygieł, M. (2014) · Journal of Analytical & Bioanalytical Techniques · doi:10.4172/2155-9872.1000227 · Cited by 9
“Chlorophylls (Chls) and bacteriochlorophylls (BChls), the major photosynthetic pigments, have many benefits of excellent photosensitizers, including high yields of triplet states and very intensive light absorption in the near-infrared region of the spectrum, which coincides with the therapeutic window of human tissue…”
BackgroundVarnosfaderani, Z. G., Emamzadeh, R., Nazari, M., & Zarean, M. (2019) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2019.07.085 · Cited by 9
Zhou, K., Ding, Y., Vuletic, I., Tian, Y., Li, J., Liu, J., Huang, Y., Sun, H., Li, C., Ren, Q., et al. (2018) · BioMedical Engineering OnLine · doi:10.1186/s12938-018-0615-0 · Cited by 9
Haider, M., Freytag, V., Krause, L., Spethmann, T., Gosau, T., Beine, M. C., Knies, C., Schröder‐Schwarz, J., Horn, M., Riecken, K., et al. (2024) · Clinical & Experimental Metastasis · doi:10.1007/s10585-024-10268-4 · Cited by 8
Fábrega, M.-J., Knödlseder, N., Nevot, G., Sanvicente-García, M., Toloza, L., Santos‐Moreno, J., & Güell, M. (2021) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.1c00894 · Cited by 8
Bioluminescent Zebrafish Transplantation Model for Drug Discovery
Hason, M., Jovicic, J., Vonkova, I., Bojic, M., Simon-Vermot, T., White, R. M., & Bartůněk, P. (2022) · Frontiers in Pharmacology · doi:10.3389/fphar.2022.893655 · Cited by 8
Shining light on the electronic structure and relaxation dynamics of the isolated oxyluciferin anion
Patel, A. M., Henley, A., Parkes, M. A., Aßmann, M., Worth, G. A., Anderson, J. C., & Fielding, H. H. (2020) · Physical Chemistry Chemical Physics · doi:10.1039/d0cp03276j · Cited by 8
Molecular Imaging of Stem Cells
Abbas, F., Wu, J. C., Gambhir, S. S., & Rodriguez-Porcel, M. G. (2019) · StemJournal · doi:10.3233/stj-190003 · Cited by 8
“One of the major advantages of SPECT and PET imaging is their high sensitivity (nano- and femtomolar, respectively), which permits the detection of relatively low amounts of signal [24, 61, 62].”
de la Fuente, L. R., Cancela, I. G., Estévez‐Salguero, Á., Iglesias, P., & Costoya, J. A. (2022) · Analytica Chimica Acta · doi:10.1016/j.aca.2022.340084 · Cited by 8
Multi-spectral luminescence tomography with the simplified spherical harmonics equations
Klose, A. D. (2012) · Springer eBooks · doi:10.1007/978-3-642-21907-8_2 · Cited by 8
Suemizu, H., Kawai, K., Higuchi, Y., Hashimoto, H., Ogura, T., Itoh, T., Sasaki, E., & Nakamura, M. (2013) · PLoS ONE · doi:10.1371/journal.pone.0082708 · Cited by 8
“However, optical probes labeled with fluorochromes that emit light in the 400-–700 nm range, such as green fluorescent protein (GFP), have limited tissue penetration and high tissue autofluorescence [6].”
BackgroundNIR Autofluorescence: Molecular Origins and Emerging Clinical Applications
del Rosal, B., Thomas, G., Mahadevan-Jansen, A. M., & Stoddart, P. R. (2020) · Springer eBooks · doi:10.1007/978-3-030-32036-2_2 · Cited by 8
Metabolic mapping by enzyme histochemistry in living animals, tissues and cells.
Noorden, C. J. F. V. (2009) · PubMed · Cited by 8
Hagelschuer, I., Hauff, P., Strube, A., Käkönen, S.-M., & von Degenfeld, G. (2009) · ALTEX · doi:10.14573/altex.2009.3.177 · Cited by 8
Sakama, A., Orioka, M., & Hiruta, Y. (2024) · Biophysics and Physicobiology · doi:10.2142/biophysico.bppb-v21.s004 · Cited by 8
Roy, M., & Wilson, B. C. (2009) · International Journal of Nanotechnology · doi:10.1504/ijnt.2009.024639 · Cited by 7
Briestenská, K., Mikušová, M., Tomčíková, K., Kostolanský, F., & Varečková, E. (2021) · Archives of Microbiology · doi:10.1007/s00203-021-02458-5 · Cited by 7
A fast solver for an inverse problem arising in bioluminescence tomography
Gong, R., Cheng, X., & Han, W. (2014) · Journal of Computational and Applied Mathematics · doi:10.1016/j.cam.2014.02.014 · Cited by 7
Creath, K., & SCHWARTZ, G. E. R. (2006) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.684726 · Cited by 6
Noninvasive Imaging of Reporter Gene Expression and Distribution In Vivo
Chuang, K.-H., & Cheng, T. (2010) · Fooyin Journal of Health Sciences · doi:10.1016/s1877-8607(10)60007-0 · Cited by 6
Design of a multimodal fibers optic system for small animal optical imaging
Spinelli, A. E., Pagliazzi, M., & Boschi, F. (2014) · Physica Medica · doi:10.1016/j.ejmp.2014.10.082 · Cited by 6
“Small animals optical imaging systems are widely used in pre-clinical research to image in vivo the bio-distribution of light emitting probes using bioluminescence [1,2], fluorescence [3] or Cerenkov luminescence [4e7], modalities.”
MethodA self-assembling magnetic resonance beacon for the detection of microRNA-1
Lee, J., Kang, H. J., Lee, Y. S., Heo, H., Gu, H.-N., Cho, S., & Kim, S. (2015) · Chemical Communications · doi:10.1039/c4cc10231b · Cited by 6
Molecular Imaging in TB: From the Bench to the Clinic
Andreu, N., Paul, T., & Wiles, S. (2012) · InTech eBooks · doi:10.5772/30595 · Cited by 6
“This is mainly due to the high levels of background fluorescence in vivo compared to luminescence, due to endogenously produced fluorophores such as keratin, porphyrins, NAD(P)H, collagen and elastin (Troy et al., 2004).”
Background
Metadata
- Authors
- Troy, T., Jekic-McMullen, D., Sambucetti, L., & Rice, B.
- Corresponding author
- Troy, Tamara
- ORCID
- Sambucetti, Lidia
- Venue
- Molecular Imaging
- Publisher
- SAGE Publications
- Published
- 2004-01-01
- Volume
- 3
- Issue
- 1
- Pages
- 9-23
- ISSN
- 1535-3508 (ISSN-L)
- 1536-0121
- OpenAlex
- W2059614428
- Cited by
- 418
- References
- 30
- Citations by year
- 2026: 3 · 2025: 10 · 2024: 15 · 2023: 14 · 2022: 13 · 2021: 16 · 2020: 20 · 2019: 17 · 2018: 12 · 2017: 13 · 2016: 16 · 2015: 14 · 2014: 18 · 2013: 22 · 2012: 28
- FWCI
- 8.41
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- Molecular Imaging (publishedVersion)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › bioluminescence and chemiluminescence research
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Advanced Fluorescence Microscopy Techniques
- Keywords
- bioluminescence reporter, fluorescent reporter, detection sensitivity, optical molecular imaging, autofluorescence, signal-to-background ratio, radiance calibration, far-red fluorescence, near-infrared fluorescence, small animal imaging
- MeSH terms
- Adenocarcinoma, Animals, Diagnostic Imaging, Female, Fluorescence, Fluorescent Dyes, HeLa Cells, Humans, Luminescent Measurements, Luminescent Proteins, Male, Mice, Inbred Strains, Mice, Nude, Organic Chemicals, Prostatic Neoplasms, Sensitivity and Specificity, Models, Animal, Cell Line, Tumor, Mice, Optics and Photonics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.