Quantitative Comparison of the Sensitivity of Detection of Fluorescent and Bioluminescent Reporters in Animal Models
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
Bioluminescent and fluorescent reporters are finding increased use in optical molecular imaging in small animals. In the work presented here, issues related to the sensitivity of in vivo detection are examined for standard reporters. A high-sensitivity imaging system that can detect steady-state emission from both bioluminescent and fluorescent reporters is described. The instrument is absolutely calibrated so that animal images can be analyzed in physical units of radiance allowing more quantitative comparisons to be performed. Background emission from mouse tissue, called autoluminescence and autofluorescence, is measured and found to be an important limitation to detection sensitivity of reporters. Measurements of dual-labeled (bioluminescent/fluorescent) reporter systems, including PC-3M-luc/DsRed2-1 and HeLa-luc/PKH26, are shown. The results indicate that although fluorescent signals are generally brighter than bioluminescent signals, the very low autoluminescent levels usually results in superior signal to background ratios for bioluminescent imaging, particularly compared with fluorescent imaging in the green to red part of the spectrum. Fluorescence detection sensitivity improves in the far-red to near-infrared, provided the animals are fed a low-chlorophyll diet to reduce autofluorescence in the intestinal region. The use of blue-shifted excitation filters is explored as a method to subtract out tissue autofluorescence and improve the sensitivity of fluorescent imaging.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Wave Propagation and Scattering in Random Media
(1978) · Elsevier eBooks · doi:10.1016/c2013-0-10906-3 · Cited by 4,709
A review of the optical properties of biological tissues
Cheong, W. F., Prahl, S. A., & Welch, A. J. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64354 · Cited by 2,530 · cited 1×
“5 cm 1 for wavelengths between 600 and 1000 nm [25].”
BackgroundWater-Soluble Quantum Dots for Multiphoton Fluorescence Imaging in Vivo
Larson, D. R., Zipfel, W. R., Williams, R. M., Clark, S. W., Bruchez, M. P., Wise, F. W., & Webb, W. W. (2003) · Science · doi:10.1126/science.1083780 · Cited by 2,286
In vivo imaging of tumors with protease-activated near-infrared fluorescent probes
Weissleder, R., Tung, C.-H., Mahmood, U., & Bogdanov, A. (1999) · Nature Biotechnology · doi:10.1038/7933 · Cited by 1,591
Åkerman, M. E., Chan, W. C. W., Laakkonen, P., Bhatia, S. N., & Ruoslahti, E. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.152463399 · Cited by 1,437 · cited 1×
“probes such as quantum dots are also beginning to find biological applications [15–17].”
BackgroundBoundary conditions for the diffusion equation in radiative transfer
Haskell, R. C., Svaasand, L. O., Tsay, T.-T., Feng, T.-C., Tromberg, B. J., & McAdams, M. S. (1994) · Journal of the Optical Society of America A · doi:10.1364/josaa.11.002727 · Cited by 1,138 · cited 1×
“bounded medium requires treatment of the tissue–air boundary conditions [27].”
BackgroundFluorescence molecular tomography resolves protease activity in vivo
Ntziachristos, V., Tung, C.-H., Bremer, C., & Weissleder, R. (2002) · Nature Medicine · doi:10.1038/nm729 · Cited by 827 · cited 1×
“For applications such as tumor visualization, target-activated probes have been used [9,10].”
MethodPhotonic detection of bacterial pathogens in living hosts
Contag, C. H., Contag, P. R., Mullins, J. I., Spilman, S. D., Stevenson, D. K., & Benaron, D. A. (1995) · Molecular Microbiology · doi:10.1111/j.1365-2958.1995.mmi_18040593.x · Cited by 652 · cited 1×
“This technology has a large range of applications, including study of infectious disease, oncology, pharmacokinetics and pharmacodynamics, toxicology, and gene expression in light-producing transgenic animals [1–12].”
BackgroundSelection of Quantum Dot Wavelengths for Biomedical Assays and Imaging
Lim, Y. T., Kim, S., Nakayama, A., Stott, N. E., Bawendi, M. G., & Frangioni, J. V. (2003) · Molecular Imaging · doi:10.1162/15353500200302163 · Cited by 559
Optical imaging of Renilla luciferase reporter gene expression in living mice
Bhaumik, S., & Gambhir, S. S. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.012611099 · Cited by 536 · cited 1×
“This technology has a large range of applications, including study of infectious disease, oncology, pharmacokinetics and pharmacodynamics, toxicology, and gene expression in light-producing transgenic animals [1–12].”
Background
Cited by
Items 401–470 of 470
Detection of intracellular microRNA using a self-assembling magnetic resonance beacon
(2015) · RNA & DISEASE · doi:10.14800/rd.705
“The critical drawback of fluorescence-based imaging is its low penetration in tissue, which results in low signal-to-noise contrast ([15]).”
BackgroundMultifunctional nanophosphors for tissue imaging and drug delivery
Chen, H. (2013) · TigerPrints (Clemson University)
Mackanos, M. A., Jansen, D., & Contag, C. H. (2010) · Springer eBooks · doi:10.1007/978-90-481-8831-4_21
“However, due to a near complete absence of background signal from mammalian tissues, the signal-to-noise ratio (SNR) for BLI is extraordinary relative to other imaging modalities [5, 36 , 37].”
MethodNew technologies for fluorescence image-guided surgery
Volpi, D. (2014) · Oxford University Research Archive (ORA) (University of Oxford) · doi:10.5287/ora-j02knrqbw
Figueiredo, N. V. (2013) · Lume (Universidade Federal do Rio Grande do Sul)
Shin, M. C. (2013) · Deep Blue (University of Michigan)
Whole body time domain fluorescence imaging of fluorescent proteins in preclinical models
Rice, W. L., & Kumar, A. T. N. (2014) · Biomedical optics · doi:10.1364/biomed.2014.bm3a.50
Structure and Dynamic Studies of the Nuclear Pore Complex at the Single-Molecule Level
Dickenson, N. E. (2008) · KU ScholarWorks (The University of Kansas)
Saban, M. R., Sferra, T. J., Davis, C. A., Simpson, C., Allen, A. M., Maier, J., Fowler, B., Knowlton, N. S., Birder, L. A., Wu, X., et al. (2010)
Cohen, A. S. (2011) · eScholarship (California Digital Library)
Yang, C. (2014) · ResearchWorks at the University of Washington (University of Washington)
Imaging of Instracellular Targets
Kersemans, V. (2016) · Imaging in medical diagnosis and therapy · doi:10.1201/b19052-36
Imaging of Transplanted and Native Stem Cells
Zhu, X.-Y., Rodriguez-Porcel, M. G., & Lerman, L. O. (2010) · Elsevier eBooks · doi:10.1016/b978-0-12-380928-5.10017-x
García, M. (2013) · TDX (Tesis Doctorals en Xarxa)
A Study of Bioluminescent and Magnetic Resonance Imaging in Murine Glioblastoma Models.
Boyer, P. (2014) · OhioLink ETD Center (Ohio Library and Information Network)
Garg, T. K., & Pandey, T. (2017) · Stem cell biology and regenerative medicine · doi:10.1007/978-3-319-51833-6_6
Bioluminescence Imaging of Canine Osteosarcoma in an Orthotopic Murine Model
Rose, L. L. (2015) · OhioLink ETD Center (Ohio Library and Information Network)
Barcellos, V. D. A. (2013) · Lume (Universidade Federal do Rio Grande do Sul)
Emerging Concepts and Techniques
Steffen, J. M., & Steffen, M. C. (2010) · Elsevier eBooks · doi:10.1016/b978-0-08-046884-6.00242-6
Aplicaciones de la biofotónica a la terapéutica de "Leishmania"
Álvarez, E. C. (2014) · Buleria (Universidad de León) · doi:10.18002/10612/4243
Lugongolo, M. Y., Noto, L. L., Mâaza, M., Mthunzi-Kufa, P. T., & Ombinda-Lemboumba, S. S. (2018) · Optical Diagnostics and Sensing: Toward Point-of-Care Diagnostics · doi:10.1117/12.2290168
“Since the majority of mammalian cells have some auto-luminescence ([17]), minute of levels of luminescence were also detected in uninfected cells hence our results show some luminescence even in the absence of infection.”
Result조혜림 (2015) · Seoul National University Open Repository (Seoul National University)
Expanding the bioluminescent toolkit for in vivo imaging
Jones, K. A. (2017) · eScholarship (California Digital Library)
Optical In Vivo Imaging in Tuberculosis Research
Sharan, R., Galbadage, T., Saenkham, P., Moule, M. G., Sule, P., Kong, Y., & Cirillo, J. D. (2019) · Springer eBooks · doi:10.1007/978-3-030-25381-3_8
Cisneros, B. T., & Devaraj, N. K. (2020) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2020.12.29.424659
“and bioluminescent proteins) for longitudinal studies.[49,50] The most promising potential use for these enzymes, however, may be related to the body of work involving synthetic receptors sensitive to caffeine or other methylxanthines.”
BackgroundCho, H. (2010) · OhioLink ETD Center (Ohio Library and Information Network)
Examining HIV infected cells using optical trapping and Raman spectroscopy
Lugongolo, M. Y., Ombinda-Lemboumba, S. S., Manoto, S. L., & Mthunzi-Kufa, P. T. (2021) · Optical Trapping and Optical Micromanipulation · doi:10.1117/12.2595766
“However, the luciferase assay results in figure 2 show that the uninfected cells had low levels of luminescence due to endogenous bioluminescence (autoluminescence), which occurs in most mammalian cells at low levels [26].”
BackgroundDeveloping Caspase-1 Biosensors to Monitor Inflammation in Vitro and in Vivo
Talley, S. (2020) · Loyola eCommons (Loyola University of Chicago) · Cited by 1
Functional Imaging Using Bioluminescent Reporter Genes in Living Subjects
Lyons, S. K., Francis, K. P., & Contag, C. H. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-816386-3.00004-1
Faculty Opinions recommendation of Targeting improves MSC treatment of inflammatory bowel disease.
O'Brien, T. A., & Dolnikov, A. (2010) · Faculty Opinions – Post-Publication Peer Review of the Biomedical Literature · doi:10.3410/f.3458958.3153058
Lewis, M. A. (2016) · Imaging in medical diagnosis and therapy · doi:10.1201/b19052-14
Roncali, E., Tavitian, B., Texier, I., Peltié, P., Perraut, F., Boutet, J., Cognet, L., Lounis, B., Marguet, D., Thoumine, O. R., et al. (2009) · Springer eBooks · doi:10.1007/978-3-540-88633-4_7
Carlson, J. A. (2012) · Faculty Opinions – Post-Publication Peer Review of the Biomedical Literature · doi:10.3410/f.717950353.793455604
Necessity of Anatomically Real Numerical Phantoms in Optical Metrology: A Study
Kumari, V., Barak, N., & Sheoran, G. (2022) · Springer eBooks · doi:10.1007/978-981-19-1550-5_76-1
Design of Bioluminescent Protein-Nanoparticle Complexes for Targeted Imaging
Melchior, A. N. (2012)
Necessity of Anatomically Real Numerical Phantoms in Optical Metrology: A Study
Kumari, V., Barak, N., & Sheoran, G. (2023) · Springer eBooks · doi:10.1007/978-981-99-2074-7_76
Isah, A. S., Ramachandran, R., Sukumaran, A. T., Kiess, A. S., Castañeda, C. D., Boltz, T. P., Macklin, K. S., Abdelhamed, H., & Zhang, L. (2024) · Microbiology Spectrum · doi:10.1128/spectrum.01263-24
Bioluminescence imaging of cancer therapy
Natarajan, A., Sekar, T. V., & Paulmurugan, R. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-22253-5.00018-2
Advancements in Biomedical Imaging Using Fluorescence and Bioluminescence
Kashyap, A., Jakhar, M., Rani, N., & Singh, T. G. (2025) · Wiley eBooks · doi:10.1002/9781394348084.ch6
Research progress on radioactive quantum dots for biomedical applications
Li, Z., Sui, J., Jin, Q., Ma, A., Han, S., Zhang, X., Xu, J., & Zhang, J. (2025) · Nano Research · doi:10.26599/nr.2025.94908298
Swamy, G. (2018) · Libraries and Cultural Resources (University of Calgary) · doi:10.11575/prism/5449
Fukuchi, M., Saito, R., Maki, S., Hagiwara, N., Nakajima, Y., Mitazaki, S., Izumi, H., & Mori, H. (2020) · Figshare · doi:10.6084/m9.figshare.12925958
Belderbos, S. (2020) · Lirias (KU Leuven)
The utility and application of non-invasive fluorescent imaging in murine models of allergic asthma
Lytwyn, M. (2017) · Mspace (University of Manitoba)
Helicobacter pylori: cellular immunity and protection from Multiple Sclerosis
Jenkins, H. H. (2022) · Nottingham ePrints (University of Nottingham)
Sanvicente-García, M. (2023) · Repositori digital de la UPF (Universitat Pompeu Fabra)
Bornmann, C. (2007) · FreiDok plus (Universitätsbibliothek Freiburg)
Quijano‐Rubio, A. (2021) · ResearchWorks at the University of Washington (University of Washington)
Investigation of Phosphate-Based Reactions in the Context of an Evolving RNA World
Kent, A. D. (2021) · eScholarship (California Digital Library)
Ultrasound-mediated transport of nanoparticles and the influence of particle density
Lea‐Banks, H. (2018) · Oxford University Research Archive (ORA) (University of Oxford) · doi:10.5287/ora-gogvr980o
Avdoshina, D., Треворович, В.-Э. В., Belikova, M. G., Сергеевна, Ж. А., Latanova, A. A., Frolova, G., Latyshev, O., Gordeychuk, I. V., & Олеговна, Б. Е. (2026) · Vaccines · doi:10.3390/vaccines14010082
低酸素誘導因子活性を有する腫瘍内浸潤細胞のin vivo光イメージング
宮原, 瞳., & Miyabara, H. (2025) · Institutional Repositories DataBase (IRDB)
Detection and tracking of single SPIO labeled cells using MRI
Heyn, C. (2007) · TSpace (University of Toronto)
New dimensions for multiplexed fluorescence imaging
Chouket, R. (2019) · theses.fr (ABES) · doi:10.70675/1f26ffd2zd4d4z4a7az90d5z06922a8b8393
Bio-engineering of extracellular vesicle-based delivery vectors
Bui, S. (2023) · theses.fr (ABES) · doi:10.70675/3a5c81b3z4731z4d34z81b0z8aaa7bde6bea
Öztürk, S. C. (2026) · Türk doğa ve fen dergisi :/Türk doğa ve fen dergisi · doi:10.46810/tdfd.1770061
Special Topics in Drug Discovery
(2016) · OAPEN (The OAPEN Foundation)
Targeting the oncogenic functions of Aurora-A by degraders
Müller, J. E. (2026) · doi:10.25972/opus-45313
PEL腫瘍マウスモデルを用いたmethyl-β-cyclodextrinの抗腫瘍効果と分子イメージングに最適化された新規無毛高度免疫不全マウスの開発
Kumiko, G. O. T. O. (2014) · Institutional Repositories DataBase (IRDB)
低酸素誘導因子活性を有する腫瘍内浸潤細胞のin vivo光イメージング
Miyabara, H. (2025) · Institutional Repositories DataBase (IRDB)
Zhao, F., Li, X., Liu, J., Zhang, D., Diao, H., & Lin, D. (2022) · doi:10.3389/fvets.2022.935005.s010
Cassano, J. M., Leonard, B. C., Martins, B. C., Vapniarsky, N., Morgan, J. T., Dow, S. W., Wotman, K. L., & Pezzanite, L. M. (2023) · doi:10.3389/fvets.2023.1293199.s001
Metadata
- Authors
- Troy, T., Jekic-McMullen, D., Sambucetti, L., & Rice, B.
- Corresponding author
- Troy, Tamara
- ORCID
- Sambucetti, Lidia
- Venue
- Molecular Imaging
- Publisher
- SAGE Publications
- Published
- 2004-01-01
- Volume
- 3
- Issue
- 1
- Pages
- 9-23
- ISSN
- 1535-3508 (ISSN-L)
- 1536-0121
- OpenAlex
- W2059614428
- Cited by
- 418
- References
- 30
- Citations by year
- 2026: 3 · 2025: 10 · 2024: 15 · 2023: 14 · 2022: 13 · 2021: 16 · 2020: 20 · 2019: 17 · 2018: 12 · 2017: 13 · 2016: 16 · 2015: 14 · 2014: 18 · 2013: 22 · 2012: 28
- FWCI
- 8.41
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- Molecular Imaging (publishedVersion)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › bioluminescence and chemiluminescence research
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Advanced Fluorescence Microscopy Techniques
- Keywords
- bioluminescence reporter, fluorescent reporter, detection sensitivity, optical molecular imaging, autofluorescence, signal-to-background ratio, radiance calibration, far-red fluorescence, near-infrared fluorescence, small animal imaging
- MeSH terms
- Adenocarcinoma, Animals, Diagnostic Imaging, Female, Fluorescence, Fluorescent Dyes, HeLa Cells, Humans, Luminescent Measurements, Luminescent Proteins, Male, Mice, Inbred Strains, Mice, Nude, Organic Chemicals, Prostatic Neoplasms, Sensitivity and Specificity, Models, Animal, Cell Line, Tumor, Mice, Optics and Photonics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.