Quantitative Comparison of the Sensitivity of Detection of Fluorescent and Bioluminescent Reporters in Animal Models
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
Bioluminescent and fluorescent reporters are finding increased use in optical molecular imaging in small animals. In the work presented here, issues related to the sensitivity of in vivo detection are examined for standard reporters. A high-sensitivity imaging system that can detect steady-state emission from both bioluminescent and fluorescent reporters is described. The instrument is absolutely calibrated so that animal images can be analyzed in physical units of radiance allowing more quantitative comparisons to be performed. Background emission from mouse tissue, called autoluminescence and autofluorescence, is measured and found to be an important limitation to detection sensitivity of reporters. Measurements of dual-labeled (bioluminescent/fluorescent) reporter systems, including PC-3M-luc/DsRed2-1 and HeLa-luc/PKH26, are shown. The results indicate that although fluorescent signals are generally brighter than bioluminescent signals, the very low autoluminescent levels usually results in superior signal to background ratios for bioluminescent imaging, particularly compared with fluorescent imaging in the green to red part of the spectrum. Fluorescence detection sensitivity improves in the far-red to near-infrared, provided the animals are fed a low-chlorophyll diet to reduce autofluorescence in the intestinal region. The use of blue-shifted excitation filters is explored as a method to subtract out tissue autofluorescence and improve the sensitivity of fluorescent imaging.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Wave Propagation and Scattering in Random Media
(1978) · Elsevier eBooks · doi:10.1016/c2013-0-10906-3 · Cited by 4,709
A review of the optical properties of biological tissues
Cheong, W. F., Prahl, S. A., & Welch, A. J. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64354 · Cited by 2,530 · cited 1×
“5 cm 1 for wavelengths between 600 and 1000 nm [25].”
BackgroundWater-Soluble Quantum Dots for Multiphoton Fluorescence Imaging in Vivo
Larson, D. R., Zipfel, W. R., Williams, R. M., Clark, S. W., Bruchez, M. P., Wise, F. W., & Webb, W. W. (2003) · Science · doi:10.1126/science.1083780 · Cited by 2,286
In vivo imaging of tumors with protease-activated near-infrared fluorescent probes
Weissleder, R., Tung, C.-H., Mahmood, U., & Bogdanov, A. (1999) · Nature Biotechnology · doi:10.1038/7933 · Cited by 1,591
Åkerman, M. E., Chan, W. C. W., Laakkonen, P., Bhatia, S. N., & Ruoslahti, E. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.152463399 · Cited by 1,437 · cited 1×
“probes such as quantum dots are also beginning to find biological applications [15–17].”
BackgroundBoundary conditions for the diffusion equation in radiative transfer
Haskell, R. C., Svaasand, L. O., Tsay, T.-T., Feng, T.-C., Tromberg, B. J., & McAdams, M. S. (1994) · Journal of the Optical Society of America A · doi:10.1364/josaa.11.002727 · Cited by 1,138 · cited 1×
“bounded medium requires treatment of the tissue–air boundary conditions [27].”
BackgroundFluorescence molecular tomography resolves protease activity in vivo
Ntziachristos, V., Tung, C.-H., Bremer, C., & Weissleder, R. (2002) · Nature Medicine · doi:10.1038/nm729 · Cited by 827 · cited 1×
“For applications such as tumor visualization, target-activated probes have been used [9,10].”
MethodPhotonic detection of bacterial pathogens in living hosts
Contag, C. H., Contag, P. R., Mullins, J. I., Spilman, S. D., Stevenson, D. K., & Benaron, D. A. (1995) · Molecular Microbiology · doi:10.1111/j.1365-2958.1995.mmi_18040593.x · Cited by 652 · cited 1×
“This technology has a large range of applications, including study of infectious disease, oncology, pharmacokinetics and pharmacodynamics, toxicology, and gene expression in light-producing transgenic animals [1–12].”
BackgroundSelection of Quantum Dot Wavelengths for Biomedical Assays and Imaging
Lim, Y. T., Kim, S., Nakayama, A., Stott, N. E., Bawendi, M. G., & Frangioni, J. V. (2003) · Molecular Imaging · doi:10.1162/15353500200302163 · Cited by 559
Optical imaging of Renilla luciferase reporter gene expression in living mice
Bhaumik, S., & Gambhir, S. S. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.012611099 · Cited by 536 · cited 1×
“This technology has a large range of applications, including study of infectious disease, oncology, pharmacokinetics and pharmacodynamics, toxicology, and gene expression in light-producing transgenic animals [1–12].”
Background
Cited by
Items 301–400 of 470
Smeesters, P. R., & Botteaux, A. (2020) · Methods in molecular biology · doi:10.1007/978-1-0716-0467-0_3 · Cited by 6
Semiautomated analysis of an optical ATP indicator in neurons
Dehkharghanian, T., Hashemiaghdam, A., & Ashrafi, G. (2022) · Neurophotonics · doi:10.1117/1.nph.9.4.041410 · Cited by 6
“does not suffer from this limitation as autoluminescence of most cells is negligibly low.(4) Therefore, any signal that is reliably detected can be attributed to luminescence rather than background noise.”
BackgroundEstablishment of Canine Oral Mucosal Melanoma Cell Lines and Their Xenogeneic Animal Models
Li, S., Liu, Z., Lv, J., Lv, D., Xu, H., Shi, H., Liu, G., Lin, D., & Jin, Y. (2024) · Cells · doi:10.3390/cells13110992 · Cited by 5
“However, Luc bio-luminescence was effective due to its higher luminescence-signal-to-background ratio [45], which makes it suitable for luminescence signal detection in metastasis models [44,46].”
BackgroundJansons, J., Avdoshina, D., Dudorova, A., Rubio, E. R., Sokolovska, L., Perminov, D., Lindenberga, I., Nicolai, H., Gebrila, S., Chowdhury, S., et al. (2025) · Infectious Agents and Cancer · doi:10.1186/s13027-025-00682-y · Cited by 5
“All values represent the mean ± SD. Cut-off line designates the level of photon flux due to autoluminescence [110] in the organs of naïve untreated mice ( n = 3) + SD. Statistical analysis was performed by Mann-Whitney test, **— p 0.01 migration of tumor cells to distal organs, seen as a decrease…”
InfluentialCassano, J. M., Leonard, B. C., Martins, B. C., Vapniarsky, N., Morgan, J. T., DOW, S. W., Wotman, K. L., & Pezzanite, L. M. (2023) · Frontiers in Veterinary Science · doi:10.3389/fvets.2023.1293199 · Cited by 5
Emerging Synthetic Bioluminescent Reactions for Non-Invasive Imaging of Freely Moving Animals
Kuchimaru, T. (2024) · International Journal of Molecular Sciences · doi:10.3390/ijms25137338 · Cited by 5
“In 2 of 10 contrast, BLI bene fi ts from the single-path travel of photons and the absence of autoluminescence signals from living tissues. sensitivity that is 100–1000 times greater than that of fluorescence imaging [14].”
BackgroundBiosensor technology in aging research and age-related diseases
He, Y., Wu, Y., Mishra, A., Acha, V., Andrews, T., & Hornsby, P. J. (2011) · Ageing Research Reviews · doi:10.1016/j.arr.2011.11.004 · Cited by 5
Vega, J. D., Hara, D., Schmidt, R. M., Abuhaija, M. B., Tao, W., Dogan, N., Pollack, A. S., Ford, J. C., & Shi, J. (2023) · Frontiers in Oncology · doi:10.3389/fonc.2023.1130155 · Cited by 5
“Together with the intrinsic autofluorescence from the endogenous chromophores (20), these nonspecific background signals will mix with the tumor fluorescence signal, therefore reducing tumor-detection sensitivity and specificity, particularly when the tumor signal is weak.”
BackgroundBiomedical Imaging and Image Processing in Tissue Engineering
Shen, H., Goldstein, A. S., & Wang, G. (2010) · Springer eBooks · doi:10.1007/978-3-642-02824-3_9 · Cited by 5
“Recent study showed that BLI had the sensitivity to trace ~100 photons/s/cm/sr, which were about 10–100 labeled cells under subcutaneous situations [73, 79].”
BackgroundFu, J., Yang, X., Quan, G., & Gong, H. (2010) · Chinese Optics Letters · doi:10.3788/col20100811.1075 · Cited by 5
Ma, X., Sun, Y., Wang, S., Yang, Z., & Song, Y. (2012) · PubMed Central · doi:10.3779/j.issn.1009-3419.2012.06.01 · Cited by 5
Molecular Imaging of Cell Therapy for Gastroenterologic Applications
Dimayuga, V. M., & Rodriguez-Porcel, M. G. (2011) · Pancreatology · doi:10.1159/000327395 · Cited by 5
Radionuklidaktivierte Nanomaterialien und ihre biomedizinische Anwendung
Ferreira, C. A., Ni, D., Rosenkrans, Z. T., & Cai, W. (2019) · Angewandte Chemie · doi:10.1002/ange.201900594 · Cited by 5
Antropov, D. N., Markov, O. V., Dome, A. S., Puchkov, P. A., Shmendel, E. V., Gladkikh, D. V., Golyshev, V. M., Matveeva, A. M., Maslov, M. A., & Stepanov, G. A. (2025) · Vavilov Journal of Genetics and Breeding · doi:10.18699/vjgb-25-81 · Cited by 4
Generation of Random luxCDABE Transcriptional Fusions in the Genome of Salmonella enterica
de la Rosa-Altura, J. J., Benešová, B., Panadero-Medianero, C., Amador-Álvarez, A., Aguilera-Herce, J., Araujo‐Garrido, J. L., Bernal-Bayard, J., & Ramos‐Morales, F. (2020) · Methods in molecular biology · doi:10.1007/978-1-0716-0791-6_13 · Cited by 4
Zhao, F., Li, X., Liu, J., Zhang, D., Diao, H., & Lin, D. (2022) · Frontiers in Veterinary Science · doi:10.3389/fvets.2022.935005 · Cited by 4
Systemically delivered mRNA-LNPs transfect primary and secondary liver tumors
Leighton, L. J., Gee, Y. J., Madugalle, S. U., Victorova, M., Carrodus, N. L., Bridle, K. R., Howell, S. A., Liang, X., Miller, G. C., McMillan, C. L. D., et al. (2026) · Molecular Therapy — Nucleic Acids · doi:10.1016/j.omtn.2026.102989 · Cited by 4
“Notably, green fluorescent signal in the digestive tract likely arises from gut contents 36 and does not indicate the presence of eGFP (Figure S1). eGFP was not detected in serum from any of 6 injected mice tested (Figure S2), confirming that eGFP is not secreted into the blood-stream and that no…”
Raman spectroscopy in biomedicine: new advances in SERRS cancer imaging.
Feuillie, C. (2015) · PubMed Central · doi:10.3978/j.issn.2305-5839.2015.09.34 · Cited by 4
“The spectral fingerprints display intense and sharp bands that are much narrower than fluorescence bands (6,7), and show no photobleaching or background fluorescence, in marked contrast with fluorescence- and bioluminescence-based methods (8).”
BackgroundDynamic contrast for overcoming spectral interferences in fluorescence imaging
Chouket, R., Pellissier‐Tanon, A., Lemarchand, A., Espagne, A., Saux, T. L., & Jullien, L. (2020) · Journal of Physics Photonics · doi:10.1088/2515-7647/ab9099 · Cited by 4
Generation of Bioluminescent Group A Streptococcus for Biophotonic Imaging
Loh, J. M. S., Soh, K. Y., & Proft, T. (2020) · Methods in molecular biology · doi:10.1007/978-1-0716-0467-0_6 · Cited by 4
Kim, S. K., Kim, J. Y., Choi, Y., Lee, M., Lee, B., Lee, H. C., & Lee, E. J. (2009) · Biotechnology Letters · doi:10.1007/s10529-009-0113-3 · Cited by 4
“Current optical imaging systems have limited clinical applications, however, because of the technical problem that fluorescence does not penetrate beyond a few centimeters of tissue (Troy et al. 2004; Keren et al. 2008).”
BackgroundMethodNumerical approximation of bioluminescence tomography based on a new formulation
Cheng, X., Gong, R., & Han, W. (2008) · Journal of Engineering Mathematics · doi:10.1007/s10665-008-9246-y · Cited by 4
In Vivo Tumor Detection in Small Animals by Hematoporphyrin-Mediated Fluorescence Imaging
Autiero, M., Cozzolino, R., Laccetti, P., Marotta, M., Quarto, M., Riccio, P., & Roberti, G. (2010) · Photomedicine and Laser Surgery · doi:10.1089/pho.2009.2567 · Cited by 4
“39 We are also investigating a different porphyrin compound with an excitation/emission band shifted in NIR window.”
Noninvasive Imaging of Bone-Specific Collagen I Expression in a Luciferase Transgenic Mouse Model
Liu, J., Arends, R. J., Martens, A. C., den Brok-Bardoel, M. H. C., Scheepers, M. G. H., van Blitterswijk, C., & de Boer, J. (2010) · Tissue Engineering Part C Methods · doi:10.1089/ten.tec.2009.0594 · Cited by 4
“Tissues particularly attenuate light with a wave-length in the range of 400 to 600 nm, but less between 600 to 950 nm. 27 31 Nevertheless, there are reports stating that the skin and muscles caused a 2–3-fold attenuation, 32 and the light intensity is attenuated approximately NONINVASIVE IMAGING OF…”
Diet‐induced microbial autofluorescence confounds flow cytometry of ex vivo isolated fecal microbes
Denu, L., Lubin, J., Douglas, B. B., Tuluc, F., & Silverman, M. A. (2019) · European Journal of Immunology · doi:10.1002/eji.201948087 · Cited by 4
MULTISPECTRAL BIOLUMINESCENCE TOMOGRAPHY WITH X-RAY CT SPATIAL PRIORS
Pekar, J. (2011) · MacSphere (McMaster University) · doi:10.71548/14806 · Cited by 4
P2RX7 inhibition reduces breast cancer induced osteolytic lesions - implications for bone metastasisPreprint
Shah, K. M., Tattersall, L., Hussain, A., Macfarlane, S. C., Williamson, A., Acosta‐Martin, A. E., Erler, J. T., Ottewell, P. D., & Gartland, A. (2022) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2021.12.31.474644 · Cited by 4
“cells [64], and smaller metastasis could cause the observed effects.”
BackgroundRamesh, A., Deshpande, N., Malik, V., Nguyen, A., Malhotra, M., Debnath, M., Brouillard, A., & Kulkarni, A. A. (2023) · Small · doi:10.1002/smll.202300978 · Cited by 3
Molecularly generated light and its biomedical applications
Ran, C., & Pu, K. (2023) · Angewandte Chemie · doi:10.1002/ange.202314468 · Cited by 3
A Step Beyond BRET: Fluorescence by Unbound Excitation from Luminescence (FUEL)
Dragavon, J. M., Sinow, C., Holland, A. D., Rekiki, A., Théodorou, I., Samson, C., Blazquez, S., Rogers, K. L., Tournebize, R., & Shorte, S. L. (2014) · Journal of Visualized Experiments · doi:10.3791/51549 · Cited by 3
Zheng, H., Wang, X., Chen, S., Shi, X., Xie, J., Mao, W., Tian, J., & Wang, F. (2018) · ACS Chemical Neuroscience · doi:10.1021/acschemneuro.8b00614 · Cited by 3
Park, C., & Cho, H. (2015) · Journal of Nanomaterials · doi:10.1155/2015/894353 · Cited by 3
Tripura, C., Khan, A. A., & Pande, G. (2012) · InTech eBooks · doi:10.5772/45876 · Cited by 3
Ripp, S. A., Sayler, G. S., & Close, D. M. (2011) · InTech eBooks · doi:10.5772/17028 · Cited by 3
“This is because the presence of the excitation signal can result in production of high levels of background autofluorescence under small animal imaging conditions, due to the presence of chromophoric material within the mammalian cell (Choy et al., 2003; Troy et al., 2004).”
BackgroundHilser, M., Trylčová, J., Bušek, P., & Šedo, A. (2012) · Folia Biologica · doi:10.14712/fb2012058030128 · Cited by 3
“Their emission wavelength beyond 600 nm dramatically decreases light absorption and scattering by the surrounding tissues, while their excitation wave- Vol. 58 129 length of about 590 nm produces less tissue autofluorescence (Troy et al., 2004; Tung et al., 2004).”
BackgroundLee, O., Kim, J., & Oh, C. H. (2017) · Experimental Dermatology · doi:10.1111/exd.13475 · Cited by 3
Spontaneous Luminescence Background in Living Nu/Nu Mice
Boschi, F., Spinelli, A. E., Calderan, L., & Sbarbati, A. (2012) · Advances in Molecular Imaging · doi:10.4236/ami.2012.22002 · Cited by 3
Autiero, M., Cozzolino, R., Laccetti, P., Marotta, M., Quarto, M., Riccio, P., & Roberti, G. (2008) · Lasers in Medical Science · doi:10.1007/s10103-007-0523-1 · Cited by 3
“The FRI system is simple enough to be integrated with a pixel radionuclide imaging system [24, 25], since the optical and radionuclide modality supply complementary information on the fluorescence-labeled and radionuclidelabeled biomedical targets, as our preliminary tests seem to indicate.”
BackgroundHwang, E. (2019) · Scholarship@Western (Western University) · Cited by 3
In cellulo and in vivo assays for compound testing against Trypanosoma cruzi
Guerra-Slompo, E. P., Picchi, G. F. A., Marek, M., Romier, C., Sippl, W., & Zanchin, N. I. T. (2023) · STAR Protocols · doi:10.1016/j.xpro.2023.102058 · Cited by 2
“Additional literature should be checked for potential interference in bioluminescence imaging of mice.(4,5)”
BackgroundYamaguchi, D., Oki, K., Kaya, Y., Sakairi, Y., Morita, Y., & Kamoshida, G. (2025) · Microbiology and Immunology · doi:10.1111/1348-0421.13225 · Cited by 2
“Additionally, autofluorescence poses a major issue when detecting weak light from deep within the body [15].”
Overview of Advances in Live Animal Imaging
Remmert, K., Hernandez, J. M., & Lwin, T. M. (2025) · Success in academic surgery · doi:10.1007/978-3-031-83034-1_17 · Cited by 2
Jimenez, A., Gressette, M., Barjon, C., Wei, M., Gourzonès, C., & Busson, P. (2011) · BMC Biotechnology · doi:10.1186/1472-6750-11-26 · Cited by 2
“Although various types of reporter genes encoding fluorescent proteins have been reported, expression of exogenous luciferase combined to systemic administration of luciferin remains the strategy of optical imaging providing the best signal/ background ratio [4].”
BackgroundReporter Gene Application in Diagnostic Assay: Review
Mohammed, A. N., Hirpa, E., & Duguma, M. (2015) · Cited by 2
Fluorometric Sensors and Devices for Biomarkers
Kumar, P., Mutreja, V., Singh, A. S. G., Watts, J., & Li, Q. (2024) · Royal Society of Chemistry eBooks · doi:10.1039/9781837673230-00095 · Cited by 2
Zhang, W., Zhang, X., Zhang, Y., Zhang, X., Zou, T., Zhao, W. H., Lv, Y., Wang, J., Dai, P., Cui, H. Z., et al. (2020) · Tissue Engineering Part A · doi:10.1089/ten.tea.2020.0129 · Cited by 2
“16 Indirect immunofluorescence detection of stem cell marker proteins using GFP and RFP can amplify specific fluo-rescence signals, reduce the autofluorescence background of biological tissues, and improve the specificity and sharpness of immunofluorescence imaging.”
RetractedSoares, D. M. M., Galeazzo, G. A., Sgro, G. G., de Moraes, G. V., Kronenberg, L., Borukh, E., Migotto, Á. E., Gruber, D. F., Sparks, J. S., Pieribone, V. A., et al. (2025) · FEBS Journal · doi:10.1111/febs.70096 · Cited by 2
Multimodality Imaging of Reporter Genes
Ray, P., & Gambhir, S. S. (2010) · Cambridge University Press eBooks · doi:10.1017/cbo9780511730405.006 · Cited by 2
Nonnegative matrix factorization using target-to-background contrast for fluorescence unmixing
Huang, S., Zhao, Y., Cheng, H., & Qin, B. (2013) · IEEE International Conference on Medical Imaging Physics and Engineering (ICMIPE) · doi:10.1109/icmipe.2013.6864553 · Cited by 2
Golding, H., & Zaitseva, M. B. (2013) · AAPS advances in the pharmaceutical sciences series · doi:10.1007/978-1-4614-8247-5_9 · Cited by 2
Ma, X., Sun, Y., Wang, S., Yang, Z., & Song, Y. (2012) · Europe PMC (PubMed Central) · doi:10.3978/j.issn.2218-6751.2012.07.01 · Cited by 2
“Due to the influence of viable mammalian cells and the optical absorption and scattering in tissues, current fluorescent imaging detects, at most, only 1×10(6) cells (11).”
BackgroundAutobioluminescent Cellular Models for Enhanced Drug Discovery
Xu, T., Conway, M. K., Frank, A. M., Brumbaugh, A., Ripp, S. A., & Close, D. M. (2016) · InTech eBooks · doi:10.5772/65062 · Cited by 2
“While these are significantly larger numbers of cells than are required for chemically stimulated bioluminescent systems, the low background associated with bioluminescence has nonetheless been shown to retain sufficient sensitivity for use in whole‐animal imaging experiments [28, 31].”
BackgroundLow-intensity calibration source for optical imaging systems
Holdsworth, D. W. (2017) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2254439 · Cited by 2
“Specialized calibration and monitoring devices have been previously described [7-11], but no routine solution is available for monitoring the performance of optical imaging systems.”
BackgroundChouket, R., Zhang, R., Pellissier‐Tanon, A., Lemarchand, A., Espagne, A., Saux, T. L., & Jullien, L. (2021) · Methods in molecular biology · doi:10.1007/978-1-0716-1593-5_13 · Cited by 2
Revealing Biomolecular Mechanisms Through In Vivo Bioluminescence Imaging
Doyle, T. C., Wang, Q., & Contag, C. H. (2010) · Cambridge University Press eBooks · doi:10.1017/cbo9780511730405.003 · Cited by 2
Reporter Gene Technologies for Imaging Cell Fates in Hematopoiesis
Kusy, S., & Contag, C. H. (2013) · Methods in molecular biology · doi:10.1007/978-1-4614-9437-9_1 · Cited by 2
The Purification of Human Adult Progenitor Cell Types to Promote Angiogenesis
Sherman, S. E. (2019) · Scholarship@Western (Western University) · Cited by 2
Douraghy, A., & Chatziioannou, A. F. (2010) · Springer eBooks · doi:10.1007/978-3-540-85962-8_18 · Cited by 2
Zyl, V., & Fayghan, W. (2015) · SUNScholar (Stellenbosch University) · Cited by 2
Tri-modality small animal imaging system
Kundu, B. K., Stolin, A., Pole, J., Baumgart, L. A., Fontaine, M. L., Wojcik, R., Kross, B., Zorn, C., Majewski, S., & Williams, M. B. (2005) · IEEE Symposium Conference Record Nuclear Science 2004. · doi:10.1109/nssmic.2004.1466722 · Cited by 2
“, the ability to detect low quantities of the probe) that is superior to that of gamma probes [2].”
BackgroundKwong, T. C. (2017) · eScholarship (California Digital Library) · Cited by 2
A novel 3D PDAC model system developed with the use of decellularized matrix scaffolds
Rozmus, E. R. (2019) · NVA (Nasjonalt vitenarkiv) · Cited by 2
A luminescent calcium biosensor enabling endpoint measurement of GPCR-mediated calcium signaling
Doi, K., Kise, R., Shimizume, K., Yanagawa, M., & Inoue, A. (2026) · Communications Biology · doi:10.1038/s42003-026-09920-4 · Cited by 1
“In contrast, auto fl uorescence from biological samples and intrinsic fl uorescence from test compounds may interfere with fl uorescence-based assays, thereby increasing the risk of false-positive and false-negative results 19 .”
Non-invasive imaging of transgenic GFP expression in neonatal mouse brain
Ho, G., Zhang, C., & Zhuo, L. (2007) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.700066 · Cited by 1
Illustrating Molecular Events with Light: A Perspective on Optical Reporter Genes
Ray, P. (2009) · Springer eBooks · doi:10.1007/978-0-387-93874-5_8 · Cited by 1
“... cameras) has enabled external detection of very low levels of light emitted from living cells and animals as models of human biology and diseases (Thorne and Contag 2005) (Fig. 1). This requires that the imaging system incorporates an extremely light-tight enclosure, a very sensitive camera capable of long exposur…”
BackgroundInfluentialSpectral unmixing for in vivo fluorescence imaging based on accurate target-to-background estimation
Hu, C., Zhao, Y. J., & Qin, B. (2013) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2013.6829290 · Cited by 1
“However, this technology suffered from the overlapped problem that the labeled multitarget fluorescences and tissue background fluorescence are overlapped in image space and emitting spectra, so that it is difficult to locally extract the single labeled target fluorescence without other different fluorescent component…”
BackgroundSmall Animal Imaging in Oncology Drug Development
Kalen, J. D., & Tatum, J. L. (2018) · Springer eBooks · doi:10.1007/978-3-030-02973-9_5 · Cited by 1
Bulte, J. W. M. (2012) · Springer eBooks · doi:10.1007/978-1-4614-5711-4_21 · Cited by 1
Kervella, M., Humeau‐Heurtier, A., & L’Huillier, J.-P. (2008) · IRBM · doi:10.1016/j.rbmret.2007.11.022 · Cited by 1
Kervella, M., Humeau‐Heurtier, A., & L’Huillier, J.-P. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353709 · Cited by 1
Chen, X., Chen, D., Liu, F., Cong, W., Wang, G., & Liang, J. (2016) · Imaging in medical diagnosis and therapy · doi:10.1201/b19052-16 · Cited by 1
Deliolanis, N. C., Schultz, C. P., & Ntziachristos, V. (2012) · Wiley eBooks · doi:10.1002/9781118271933.ch8 · Cited by 1
Optical‐Based Detection in Live Animals
Ogawa, M., & Takakura, H. (2019) · Wiley eBooks · doi:10.1002/9783527344406.ch3 · Cited by 1
Target Area Extraction Algorithm for the In Vivo Fluorescence Imaging of Small Animals
Zhang, Q., Wang, L., Qian, Q., Wang, J., Cheng, W., & Han, K. (2020) · ACS Omega · doi:10.1021/acsomega.0c01733 · Cited by 1
Fluorescent and Bioluminescent Probes based on Precise Molecular Design
Kumada, R., Orioka, M., Citterio, D., & Hiruta, Y. (2021) · BUNSEKI KAGAKU · doi:10.2116/bunsekikagaku.70.601 · Cited by 1
Long-Term Imaging and Electrophysiology of Single Suprachiasmatic Nucleus Neurons
Tonsfeldt, K. J., & Welsh, D. K. (2022) · Neuromethods · doi:10.1007/978-1-0716-2577-4_5 · Cited by 1
Overview of preclinical research
Huang, E., & Chen, Y. (2023) · Elsevier eBooks · doi:10.1016/b978-0-323-88423-5.00049-2 · Cited by 1
Baptista, P. M. (2012) · Cited by 2
Development and appraisal of MRI contrast agents for the in vivo analysis of stem cell grafts
Williams, S. (2012) · ORCA Online Research @Cardiff (Cardiff University) · Cited by 1
In Vivo Optical Imaging of Fluorescent Markers for Detection and Guided Resection of Cancer
Bogaards, A. (2006) · RePub (Erasmus University Rotterdam) · Cited by 1
Heteroatom‐substitued Dioxetanes and their Emerging Biomedical Applications
Nkepang, G. N., & You, Y. (2014) · Wiley eBooks · doi:10.1002/9780470682531.pat0869 · Cited by 1
Bioluminescent mouse models of prostate cancer progression and therapy
Svensson, R. U. (2010) · doi:10.17077/etd.seswx2za · Cited by 1
Magnetically modulated fluorescent probes in turbid mediaPreprint
Yang, Nguyen, K. T., Chen, H., & Anker, J. N. (2010) · arXiv (Cornell University) · doi:10.48550/arxiv.1007.2863 · Cited by 1
Sletta, K. Y. (2016) · NVA (Nasjonalt vitenarkiv) · Cited by 1
Roy, M. (2012) · TSpace (University of Toronto) · Cited by 1
Nagarajan, D. (2018) · Nottingham Trent University's Institutional Repository (Nottingham Trent Repository) · Cited by 1
Optical micro-manipulation in HIV-1 infected cells for improved HIV-1 treatment and diagnosis
Lugongolo, M. Y. (2020) · Unisa Institutional Repository (University of South Africa) · Cited by 1
Kim, J. (2016) · eScholarship (California Digital Library) · Cited by 1
Villa, I. (2015) · BOA (University of Milano-Bicocca) · Cited by 1
Minovès, M. (2021) · theses.fr (ABES) · doi:10.70675/4b67e5e7z93bdz443cz947fz7fbcccd63b9b · Cited by 1
Alkhorayef, N. (2021) · Figshare · doi:10.25392/leicester.data.15156792 · Cited by 1
Gratton, S. E. A. (2010) · Carolina Digital Repository (University of North Carolina at Chapel Hill) · doi:10.17615/mwc3-md51 · Cited by 1
Nanomateriales para terapia e imagen en el infrarrojo
Rosal Rabes, B. D. (2017) · Biblos-e Archivo (Universidad Autónoma de Madrid) · Cited by 1
Fortin, P. (2011) · theses.fr (ABES) · doi:10.70675/19139c60z4ffaz442az8006za8547beb23b8 · Cited by 1
Zhang, R. (2018) · theses.fr (ABES) · doi:10.70675/426ead3ezbe14z4fa7zb1e5zcfd0915f5201 · Cited by 1
Laminin-Functionalized Polyethylene Glycol Hydrogels for Nucleus Pulposus Regeneration
Francisco, A. T. (2013) · DukeSpace (Duke University)
Development of an Autonomous Mammalian lux Reporter System
Close, D. M. (2011)
Imaging of Reporter Genes and Stem Cells
Rodriguez-Porcel, M. G., & Gambhir, S. S. (2010) · Cambridge University Press eBooks · doi:10.1017/cbo9780511730405.013
Shin, C., & Liang, G. (2010) · InTech eBooks · doi:10.5772/6880
Moonsamy, K. (2014) · Open University of Cape Town (University of Cape Town)
Metadata
- Authors
- Troy, T., Jekic-McMullen, D., Sambucetti, L., & Rice, B.
- Corresponding author
- Troy, Tamara
- ORCID
- Sambucetti, Lidia
- Venue
- Molecular Imaging
- Publisher
- SAGE Publications
- Published
- 2004-01-01
- Volume
- 3
- Issue
- 1
- Pages
- 9-23
- ISSN
- 1535-3508 (ISSN-L)
- 1536-0121
- OpenAlex
- W2059614428
- Cited by
- 418
- References
- 30
- Citations by year
- 2026: 3 · 2025: 10 · 2024: 15 · 2023: 14 · 2022: 13 · 2021: 16 · 2020: 20 · 2019: 17 · 2018: 12 · 2017: 13 · 2016: 16 · 2015: 14 · 2014: 18 · 2013: 22 · 2012: 28
- FWCI
- 8.41
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- Molecular Imaging (publishedVersion)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › bioluminescence and chemiluminescence research
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Advanced Fluorescence Microscopy Techniques
- Keywords
- bioluminescence reporter, fluorescent reporter, detection sensitivity, optical molecular imaging, autofluorescence, signal-to-background ratio, radiance calibration, far-red fluorescence, near-infrared fluorescence, small animal imaging
- MeSH terms
- Adenocarcinoma, Animals, Diagnostic Imaging, Female, Fluorescence, Fluorescent Dyes, HeLa Cells, Humans, Luminescent Measurements, Luminescent Proteins, Male, Mice, Inbred Strains, Mice, Nude, Organic Chemicals, Prostatic Neoplasms, Sensitivity and Specificity, Models, Animal, Cell Line, Tumor, Mice, Optics and Photonics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.