Relation between Respiratory Changes in Arterial Pulse Pressure and Fluid Responsiveness in Septic Patients with Acute Circulatory Failure
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
In mechanically ventilated patients with acute circulatory failure related to sepsis, we investigated whether the respiratory changes in arterial pressure could be related to the effects of volume expansion (VE) on cardiac index (CI). Forty patients instrumented with indwelling systemic and pulmonary artery catheters were studied before and after VE. Maximal and minimal values of pulse pressure (Pp(max) and Pp(min)) and systolic pressure (Ps(max) and Ps(min)) were determined over one respiratory cycle. The respiratory changes in pulse pressure (DeltaPp) were calculated as the difference between Pp(max) and Pp(min) divided by the mean of the two values and were expressed as a percentage. The respiratory changes in systolic pressure (DeltaPs) were calculated using a similar formula. The VE-induced increase in CI was >/= 15% in 16 patients (responders) and < 15% in 24 patients (nonresponders). Before VE, DeltaPp (24 +/- 9 versus 7 +/- 3%, p < 0.001) and DeltaPs (15 +/- 5 versus 6 +/- 3%, p < 0.001) were higher in responders than in nonresponders. Receiver operating characteristic (ROC) curves analysis showed that DeltaPp was a more accurate indicator of fluid responsiveness than DeltaPs. Before VE, a DeltaPp value of 13% allowed discrimination between responders and nonresponders with a sensitivity of 94% and a specificity of 96%. VE-induced changes in CI closely correlated with DeltaPp before volume expansion (r(2) = 0. 85, p < 0.001). VE decreased DeltaPp from 14 +/- 10 to 7 +/- 5% (p < 0.001) and VE-induced changes in DeltaPp correlated with VE-induced changes in CI (r(2) = 0.72, p < 0.001). It was concluded that in mechanically ventilated patients with acute circulatory failure related to sepsis, analysis of DeltaPp is a simple method for predicting and assessing the hemodynamic effects of VE, and that DeltaPp is a more reliable indicator of fluid responsiveness than DeltaPs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Individual Comparisons by Ranking Methods
Wilcoxon, F. (1945) · Biometrics Bulletin · doi:10.2307/3001968 · Cited by 15,354
Textbook of Medical Physiology
(1966) · Annals of Internal Medicine · doi:10.7326/0003-4819-64-6-1363_2 · Cited by 9,749
Hanley, J. A., & McNeil, B. J. (1983) · Radiology · doi:10.1148/radiology.148.3.6878708 · Cited by 7,016 · cited 1×
“The areas under the ROC curves ( 6 SE) were calculated for each parameter and compared (19).”
MethodSystolic Pressure Variation as a Guide to Fluid Therapy in Patients with Sepsis-induced Hypotension
Tavernier, B., Makhotine, O., Lebuffe, G., Dupont, J., & Scherpereel, P. (1998) · Anesthesiology · doi:10.1097/00000542-199812000-00007 · Cited by 570
Stetz, C. W., Miller, R. G., Kelly, G. E., & Raffin, T. A. (1982) · PubMed · doi:10.1164/arrd.1982.126.6.1001 · Cited by 447
Perel, A., Pizov, R., & Cotev, S. (1987) · Anesthesiology · doi:10.1097/00000542-198710000-00009 · Cited by 403
MICHARD, F., CHEMLA, D., RICHARD, C., WYSOCKI, M., PINSKY, M. R., LECARPENTIER, Y., & TEBOUL, J.-L. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.159.3.9805077 · Cited by 371
Self-citationAstiz, M. E., & Rackow, E. C. (1998) · The Lancet · doi:10.1016/s0140-6736(98)01134-9 · Cited by 255
Respiratory variations in right atrial pressure predict the response to fluid challenge
Magder, S. A., Georgiadis, G., & Cheong, T. H. (1992) · Journal of Critical Care · doi:10.1016/0883-9441(92)90032-3 · Cited by 188
Cited by
Bellomo, R., Ronco, C., Kellum, J. A., Mehta, R. L., Palevsky, P., & workgroup, T. A. (2004) · Critical Care · doi:10.1186/cc2872 · Cited by 6,781
Marik, P. E., Baram, M., & Vahid, B. (2008) · Chest · doi:10.1378/chest.07-2331 · Cited by 1,516
Predicting Fluid Responsiveness in ICU Patients
Michard, F., & Teboul, J.-L. (2002) · Chest · doi:10.1378/chest.121.6.2000 · Cited by 1,367
Self-citationMarik, P. E., Cavallazzi, R., Vasu, T., & Hirani, A. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181a590da · Cited by 1,272
The respiratory variation in inferior vena cava diameter as a guide to fluid therapy
Feissel, M., Michard, F., Faller, J.-P., & Teboul, J.-L. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2233-5 · Cited by 967
Self-citationPassive leg raising predicts fluid responsiveness in the critically ill*
Monnet, X., Rienzo, M., Osman, D., Anguel, N., Richard, C., Pinsky, M. R., & Teboul, J.-L. (2006) · Critical Care Medicine · doi:10.1097/01.ccm.0000215453.11735.06 · Cited by 952
Self-citationBarbier, C., Loubières, Y., Schmit, C., Hayon, J., Ricôme, J.-L., Jardin, F., & Vieillard-Baron, A. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2259-8 · Cited by 940
Jansen, T. C., van Bommel, J., Schoonderbeek, F. J., Sleeswijk Visser, S. J., van der Klooster, J. M., Lima, A. P., Willemsen, S. P., & Bakker, J. (2010) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200912-1918oc · Cited by 894
Marik, P. E., & Cavallazzi, R. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e31828a25fd · Cited by 866
Changes in Arterial Pressure during Mechanical Ventilation
Michard, F. (2005) · Anesthesiology · doi:10.1097/00000542-200508000-00026 · Cited by 713
Self-citationPulse pressure variations to predict fluid responsiveness: influence of tidal volume
De Backer, D., Heenen, S., Piagnerelli, M., Koch, M., & Vincent, J.-L. (2005) · Intensive Care Medicine · doi:10.1007/s00134-005-2586-4 · Cited by 706
Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge*
Osman, D., Ridel, C., Ray, P., Monnet, X., Anguel, N., Richard, C., & Teboul, J.-L. (2007) · Critical Care Medicine · doi:10.1097/01.ccm.0000249851.94101.4f · Cited by 695
Self-citationFeissel, M., Michard, F., Mangin, I., Ruyer, O., Faller, J.-P., & Teboul, J.-L. (2001) · CHEST · doi:10.1378/chest.119.3.867 · Cited by 612
Self-citationPrediction of fluid responsiveness: an update
Monnet, X., Marik, P. E., & Teboul, J.-L. (2016) · Annals of Intensive Care · doi:10.1186/s13613-016-0216-7 · Cited by 600
Self-citationVenous Function and Central Venous Pressure: A Physiologic Story
Gelman, S., Warner, D. S., & Warner, M. A. (2008) · Anesthesiology · doi:10.1097/aln.0b013e3181672607 · Cited by 575
Cannesson, M., Le Manach, Y., Hofer, C. K., Goarin, J. P., Lehot, J.-J., Vallet, B., & Tavernier, B. (2011) · Anesthesiology · doi:10.1097/aln.0b013e318225b80a · Cited by 554
Practice parameters for hemodynamic support of sepsis in adult patients: 2004 update
Hollenberg, S. M., Ahrens, T. S., Annane, D., Astiz, M. E., Chalfin, D. B., Dasta, J. F., Heard, S. O., Martin, C., Napolitano, L. M., Susla, G. M., et al. (2004) · Critical Care Medicine · doi:10.1097/01.ccm.0000139761.05492.d6 · Cited by 521
Reversibility of Lung Collapse and Hypoxemia in Early Acute Respiratory Distress Syndrome
Borges, J. B., Okamoto, V. N., Matos, G. F. J., Caramez, M. P. R., Arantes, P. R., Barros, F., Souza, C. E., Victorino, J. A., Kacmarek, R. M., Barbas, C. S. V., et al. (2006) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200506-976oc · Cited by 516
De Backer, D., Creteur, J., Dubois, M.-J., Sakr, Y., Koch, M., Verdant, C., & Vincent, J.-L. (2006) · Critical Care Medicine · doi:10.1097/01.ccm.0000198107.61493.5a · Cited by 491
Superior vena caval collapsibility as a gauge of volume status in ventilated septic patients
Vieillard-Baron, A., Chergui, K., Rabiller, A., Peyrouset, O., Page, B., Beauchet, A., & Jardin, F. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2361-y · Cited by 476
Antonelli, M., Levy, M., Andrews, P. J. D., Chastre, J., Hudson, L. D., Manthous, C., Meduri, G. U., Moreno, R. P., Putensen, C., Stewart, T., et al. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0531-4 · Cited by 466
Lopes, M. R., Oliveira, M. A., Pereira, V. O. S., Lemos, I. P. B., Auler, J. O. C., & Michard, F. (2007) · Critical Care · doi:10.1186/cc6117 · Cited by 442
Self-citationPerioperative Fluid Management and Clinical Outcomes in Adults
Grocott, M. P. W., Mythen, M. G., & Gan, T. J. (2005) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000148691.33690.ac · Cited by 404
Lichtenstein, D. A., Mezière, G. A., Lagoueyte, J.-F., Biderman, P., Goldstein, I., & Gepner, A. (2009) · Chest · doi:10.1378/chest.09-0001 · Cited by 401
Lamia, B., Ochagavia, A., Monnet, X., Chemla, D., Richard, C., & Teboul, J.-L. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0646-7 · Cited by 393
Self-citationMuller, L., Bobbia, X., Toumi, M., Louart, G., Molinari, N., Ragonnet, B., Quintard, H., Leone, M., Zoric, L., Lefrant, J. Y., et al. (2012) · Critical Care · doi:10.1186/cc11672 · Cited by 374
Fluid responsiveness in mechanically ventilated patients: a review of indices used in intensive care
Bendjelid, K., & Romand, J.-A. (2003) · Intensive Care Medicine · doi:10.1007/s00134-002-1615-9 · Cited by 366
Boulain, T., Achard, J.-M., Teboul, J.-L., Richard, C., Perrotin, D., & Ginies, G. (2002) · Chest · doi:10.1378/chest.121.4.1245 · Cited by 351
Self-citationMuller, L., Toumi, M., Bousquet, P.-J., Riu-Poulenc, B., Louart, G., Candela, D., Zoric, L., Suehs, C., de La Coussaye, J.-E., Molinari, N., et al. (2011) · Anesthesiology · doi:10.1097/aln.0b013e318229a500 · Cited by 343
Vieillard-Baron, A., Matthay, M., Teboul, J. L., Bein, T., Schultz, M., Magder, S., & Marini, J. J. (2016) · Intensive Care Medicine · doi:10.1007/s00134-016-4326-3 · Cited by 338
Self-citationWill This Hemodynamically Unstable Patient Respond to a Bolus of Intravenous Fluids?
Bentzer, P., Griesdale, D. E., Boyd, J., MacLean, K., Sirounis, D., & Ayas, N. T. (2016) · JAMA · doi:10.1001/jama.2016.12310 · Cited by 329
Less invasive hemodynamic monitoring in critically ill patients
Teboul, J.-L., Saugel, B., Cecconi, M., De Backer, D., Hofer, C. K., Monnet, X., Perel, A., Pinsky, M. R., Reuter, D. A., Rhodes, A., et al. (2016) · Intensive Care Medicine · doi:10.1007/s00134-016-4375-7 · Cited by 328
Self-citationMonnet, X., & Teboul, J.-L. (2008) · Intensive Care Medicine · doi:10.1007/s00134-008-0994-y · Cited by 317
Self-citationCannesson, M., Pestel, G., Ricks, C., Hoeft, A., & Perel, A. (2011) · Critical Care · doi:10.1186/cc10364 · Cited by 310
Comparison of Echocardiographic Indices Used to Predict Fluid Responsiveness in Ventilated Patients
Vignon, P., Repessé, X., Bégot, E., Léger, J., Jacob, C., Bouferrache, K., Slama, M., Prat, G., & Vieillard-Baron, A. (2017) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201604-0844oc · Cited by 308
Monnet, X., Osman, D., Ridel, C., Lamia, B., Richard, C., & Teboul, J.-L. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181968fe1 · Cited by 301
Self-citationPerioperative fluid therapy: a statement from the international Fluid Optimization Group
Navarro, L. H. C., Bloomstone, J. A., Auler, J. O. C., Cannesson, M., Rocca, G. D., Gan, T. J., Kinsky, M., Magder, S., Miller, T. E., Mythen, M., et al. (2015) · Perioperative Medicine · doi:10.1186/s13741-015-0014-z · Cited by 298
Self-citationDiagnosis of central hypovolemia by using passive leg raising
Maizel, J., Airapetian, N., Lorne, E., Tribouilloy, C., Massy, Z., & Slama, M. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0642-y · Cited by 297
Passive leg raising for predicting fluid responsiveness: importance of the postural change
Jabot, J., Teboul, J.-L., Richard, C., & Monnet, X. (2009) · Intensive Care Medicine · doi:10.1007/s00134-008-1293-3 · Cited by 289
Self-citationHofer, C. K., Müller, S. M., Furrer, L., Klaghofer, R., Genoni, M., & Zollinger, A. (2005) · Chest · doi:10.1378/chest.128.2.848 · Cited by 279
Preisman, S., Kogan, S., Berkenstadt, H., & Perel, A. (2005) · British Journal of Anaesthesia · doi:10.1093/bja/aei262 · Cited by 269
Reuter, D. A., Bayerlein, J., Goepfert, M. S. G., Weis, F. C., Kilger, E., Lamm, P., & Goetz, A. E. (2003) · Intensive Care Medicine · doi:10.1007/s00134-003-1649-7 · Cited by 265
Hemodynamic Instability in Sepsis: Bedside Assessment by Doppler Echocardiography
Vieillard-Baron, A., Prin, S., Chergui, K., Dubourg, O., & Jardin, F. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200306-816cc · Cited by 265
Yang, X., & Du, B. (2014) · Critical Care · doi:10.1186/s13054-014-0650-6 · Cited by 258
Benes, J., Giglio, M., Brienza, N., & Michard, F. (2014) · Critical Care · doi:10.1186/s13054-014-0584-z · Cited by 257
Self-citationShould we measure the central venous pressure to guide fluid management? Ten answers to 10 questions
De Backer, D., & Vincent, J.-L. (2018) · Critical Care · doi:10.1186/s13054-018-1959-3 · Cited by 255
Myatra, S. N., Prabu, N. R., Divatia, J. V., Monnet, X., Kulkarni, A. P., & Teboul, J.-L. (2017) · Critical Care Medicine · doi:10.1097/ccm.0000000000002183 · Cited by 236
Self-citationPredicting Fluid Responsiveness in Children: A Systematic Review
Gan, H., Cannesson, M., Chandler, J. R., & Ansermino, J. M. (2013) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3182a9557e · Cited by 226
Effects of changes in arterial pressure on organ perfusion during septic shock
Thooft, A., Favory, R., Salgado, D. R., Taccone, F. S., Donadello, K., De Backer, D., Creteur, J., & Vincent, J.-L. (2011) · Critical Care · doi:10.1186/cc10462 · Cited by 226
“All patients required an NE infusion for arterial hypotension resistant to fluid therapy, supported by a change in pulse pressure (ΔPP) of less than 13% [13].”
BackgroundRenal failure in septic shock: predictive value of Doppler-based renal arterial resistive index
Lerolle, N., Guérot, E., Faisy, C., Bornstain, C., Diehl, J.-L., & Fagon, J.-Y. (2006) · Intensive Care Medicine · doi:10.1007/s00134-006-0360-x · Cited by 223
“21 Mean arterial pressure (mmHg) 74 [14] 70 [13] 0.”
BackgroundZochios, V., Parhar, K., Tunnicliffe, W., Roscoe, A., & Gao, F. (2017) · Chest · doi:10.1016/j.chest.2017.02.019 · Cited by 211
Fluid responsiveness: an evolution of our understanding
Marik, P. E., & Lemson, J. (2014) · British Journal of Anaesthesia · doi:10.1093/bja/aet590 · Cited by 201
Heenen, S., De Backer, D., & Vincent, J.-L. (2006) · Critical Care · doi:10.1186/cc4970 · Cited by 197
“These dynamic indices of preload can better predict the individual response to fluid loading than static indices [1-5].”
BackgroundFluid Therapy for Critically Ill Adults With Sepsis: A Review
Zampieri, F. G., Bagshaw, S. M., & Semler, M. W. (2023) · JAMA · doi:10.1001/jama.2023.7560 · Cited by 184
Biais, M., Nouette-Gaulain, K., Cottenceau, V., Revel, P., & Sztark, F. (2008) · British Journal of Anaesthesia · doi:10.1093/bja/aen277 · Cited by 180
Respiratory variations of aortic VTI: a new index of hypovolemia and fluid responsiveness
Slama, M., Masson, H., Teboul, J.-L., Arnout, M.-L., Susic, D., Frohlich, E., & Andrejak, M. (2002) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00308.2002 · Cited by 172
“As surrogates of SV variation, respiratory variations of systemic arterial pressure (16, 11) or of aortic Doppler velocity (using transesophageal echocardiography) (8) have been reported to predict fluid responsiveness.”
BackgroundSelf-citationFunctional Hemodynamic Monitoring
Pinsky, M. R. (2015) · Critical Care Clinics · doi:10.1016/j.ccc.2014.08.005 · Cited by 168
“[44] quantified the arterial PPV and the ratio of the difference between the maximal and the minimal pulse pressure over three breaths and the mean pulse pressure over those same breaths, reported as a percent.”
BackgroundSelf-citationEffective hemodynamic monitoring
Pinsky, M. R., Cecconi, M., Chew, M. S., De Backer, D., Douglas, I., Edwards, M., Hamzaoui, O., Hernandez, G., Martin, G., Monnet, X., et al. (2022) · Critical Care · doi:10.1186/s13054-022-04173-z · Cited by 167
Self-citationCecconi, M., Hernandez, G., Dunser, M., Antonelli, M., Baker, T., Bakker, J., Duranteau, J., Einav, S., Groeneveld, A. B. J., Harris, T., et al. (2019) · Intensive Care Medicine · doi:10.1007/s00134-018-5415-2 · Cited by 128
Self-citationTargeted Fluid Minimization Following Initial Resuscitation in Septic Shock
Chen, C., & Kollef, M. H. (2015) · Chest · doi:10.1378/chest.15-1525 · Cited by 92
Metadata
- Authors
- MICHARD, F., BOUSSAT, S., CHEMLA, D., ANGUEL, N., MERCAT, A., LECARPENTIER, Y., RICHARD, C., PINSKY, M. R., & TEBOUL, J.-L.
- Venue
- American Journal of Respiratory and Critical Care Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 2000-07-01
- Volume
- 162
- Issue
- 1
- Pages
- 134-138
- ISSN
- 1073-449X (ISSN-L)
- 1535-4970
- OpenAlex
- W2144408525
- Cited by
- 1,458
- References
- 14
- FWCI
- 25.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.