CoChat

Association of the Y402H Polymorphism in Complement Factor H Gene and Neovascular Age-Related Macular Degeneration in Chinese Patients

Lau, Ling-Ing, Chen, Shih-Jen, Cheng, Ching-Yu, Yen, May-Yung, Lee, Fenq-Lih, Lin, Ming-Wei, Hsu, Wen-Ming, Wei, Yau-Huei · 2006 · Investigative Opthalmology & Visual Science
Cited by 119

The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.

Abstract

PURPOSE: Age-related macular degeneration (AMD), with its complex traits and multiple risk factors, is the leading cause of blindness in the elderly. A strong association between a coding variant, Y402H, in the complement factor H gene (CFH) and AMD has been recently identified in white patients. This study was conducted to investigate the association between the Y402H polymorphism in CFH and neovascular AMD in Chinese patients. METHODS: One hundred sixty-three Chinese patients with neovascular AMD and 232 age-matched healthy controls were enrolled in the study. Genomic DNA from white blood cells was extracted. The Y402H polymorphism in CFH, with the substitution of T to C at nucleotide position 1277 in exon 9, was determined by polymerase chain reaction-restriction fragment length polymorphism analysis. The association between the genetic polymorphism and the disease was examined by chi(2) test and logistic regression. RESULTS: The frequency of the risk allele, 1277C, was 11.3% in AMD patients compared with 2.8% in controls (P < 0.00001). Genotype frequency differed significantly between the two groups (1277TT 81.0%, 1277TC 15.3%, and 1277CC 3.7% in the AMD group; 1277TT 94.4%, 1277TC 5.6%, and 1277CC 0% in the control group; P < 0.0001). The 1277C allele significantly increased the risk for neovascular AMD and had an odds ratio of 4.4 (95% confidence interval [95% CI], 2.3-8.5; P < 0.00001). CONCLUSIONS: The allele frequency of Y402H polymorphism in CFH has an ethnic variation, with much lower 1277C frequency in Chinese than in white patients. Despite this, the polymorphism is significantly associated with neovascular AMD in the Chinese population.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.05-1532

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 119

Metadata

Authors
Lau, L.-I., Chen, S.-J., Cheng, C.-Y., Yen, M.-Y., Lee, F.-L., Lin, M.-W., Hsu, W.-M., & Wei, Y.-H.
Venue
Investigative Opthalmology & Visual Science
Published
2006-08-01
Volume
47
Issue
8
Pages
3242
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W1997085083
Cited by
119
References
21
FWCI
13.96
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.