Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 161

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Implantation and Explantation of a Wireless Epiretinal Retina Implant Device: Observations during the EPIRET3 Prospective Clinical Trial

Roessler, Gernot, Laube, Thomas, Brockmann, Claudia, Kirschkamp, Thomas, Mazinani, Babac, Goertz, Michael, Koch, Christian, Krisch, Ingo, Sellhaus, Bernd, Trieu, Hoc Khiem, Weis, Joachim, Bornfeld, Norbert, Ro¨thgen, Harald, Messner, Arthur, Mokwa, Wilfried, Walter, Peter · 2009 · Investigative Opthalmology & Visual Science

Abstract

PURPOSE: Visual sensations in patients with blindness and retinal degenerations may be restored by electrical stimulation of retinal neurons with implantable microelectrode arrays. A prospective trial was initiated to evaluate the safety and efficacy of a wireless intraocular retinal implant (EPIRET3) in six volunteers with blindness and RP. METHODS: The implant is a remotely controlled, fully intraocular wireless device consisting of a receiver and a stimulator module. The stimulator is placed on the retinal surface. Data and energy are transmitted via an inductive link from outside the eye to the implant. Surgery included removal of the lens, vitrectomy, and implantation of the EPIRET3 device through a corneal incision. The clinical outcome after implantation and explantation of the device was determined. The implant was removed after 4 weeks, according to the study protocol. RESULTS: Implantation was successful in all six patients. While the anterior part was fixed with transscleral sutures, the stimulating foil was placed onto the posterior pole and fixed with retinal tacks. The implant was well tolerated, causing temporary moderate postoperative inflammation, whereas the position of the implant remained stable until surgical removal. In all cases explantation of the device was performed successfully. Adverse events were a sterile hypopyon effectively treated with steroids and antibiotics in one case and a retinal break in a second case during explantation requiring silicone oil surgery. CONCLUSIONS: The EPIRET3 system can be successfully implanted and explanted in patients with blindness and RP. The surgical steps are feasible, and the postoperative follow-up disclosed an acceptable range of adverse events.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.08-2752

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Roessler, G., Laube, T., Brockmann, C., Kirschkamp, T., Mazinani, B., Goertz, M., Koch, C., Krisch, I., Sellhaus, B., Trieu, H. K., Weis, J., Bornfeld, N., Ro¨thgen, H., Messner, A., Mokwa, W., & Walter, P.
Venue
Investigative Opthalmology & Visual Science
Published
2009-06-01
Volume
50
Issue
6
Pages
3003
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W2047497020
Cited by
161
References
1
FWCI
4.89
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.