Frequency and Amplitude Modulation Have Different Effects on the Percepts Elicited by Retinal Stimulation
Open accessAbstract
PURPOSE: In an effort to restore functional form vision, epiretinal prostheses that elicit percepts by directly stimulating remaining retinal circuitry were implanted in human subjects with advanced retinitis pigmentosa RP). In this study, manipulating pulse train frequency and amplitude had different effects on the size and brightness of phosphene appearance. METHODS: Experiments were performed on a single subject with severe RP (implanted with a 16-channel epiretinal prosthesis in 2004) on nine individual electrodes. Psychophysical techniques were used to measure both the brightness and size of phosphenes when the biphasic pulse train was varied by either modulating the current amplitude (with constant frequency) or the stimulating frequency (with constant current amplitude). RESULTS: Increasing stimulation frequency always increased brightness, while having a smaller effect on the size of elicited phosphenes. In contrast, increasing stimulation amplitude generally increased both the size and brightness of phosphenes. These experimental findings can be explained by using a simple computational model based on previous psychophysical work and the expected spatial spread of current from a disc electrode. CONCLUSIONS: Given that amplitude and frequency have separable effects on percept size, these findings suggest that frequency modulation improves the encoding of a wide range of brightness levels without a loss of spatial resolution. Future retinal prosthesis designs could benefit from having the flexibility to manipulate pulse train amplitude and frequency independently (clinicaltrials.gov number, NCT00279500).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Consistent with Nanduri et al (2012), we found that stimulus amplitude strongly affected phosphene area in two out of three participants (p < .001) and minor axis length (p < .001), suggesting that phosphenes tended to get larger with increasing amplitude.”
From Axonal stimulation affects the linear summation of single-point perception in three Argus II users (2024) · cites this paper as Nanduri et al 2012
In the citing paper
“In addition, phosphene appearance varies systematically with stimulus amplitude and frequency (Horsager et al 2009, Nanduri et al 2012, Sinclair et al 2016) to the extent that a simple computational model can predict phosphene shape across a wide range of stimulus parameters (Granley and Beyeler 2021).”
From Axonal stimulation affects the linear summation of single-point perception in three Argus II users (2024) · cites this paper as Nanduri et al 2012
In the citing paper
“First reported by Nanduri et al (2012), pulse frequency seemed to affect phosphene shape differently than amplitude (figure 6).”
From Axonal stimulation affects the linear summation of single-point perception in three Argus II users (2024) · cites this paper as Nanduri et al 2012
In the citing paper
“However, in contrast to Nanduri et al (2012), we found that stimulus frequency also affected phosphene size (table 4 and figure 6).”
From Axonal stimulation affects the linear summation of single-point perception in three Argus II users (2024) · cites this paper as Nanduri et al (2012)
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stevens, S. S. (1957) · Psychological Review · doi:10.1037/h0046162 · Cited by 3,388
Hauswirth, W. W., Aleman, T. S., Kaushal, S., Cideciyan, A. V., Schwartz, S. B., Wang, L., Conlon, T. J., Boye, S. L., Flotte, T. R., Byrne, B. J., et al. (2008) · Human Gene Therapy · doi:10.1089/hum.2008.107 · Cited by 954
Neural remodeling in retinal degeneration
Marc, R. E., Jones, B. W., Watt, C. B., & Strettoi, E. (2003) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(03)00039-9 · Cited by 891
Visual perception in a blind subject with a chronic microelectronic retinal prosthesis
Humayun, M. S., Weiland, J. D., Fujii, G. Y., Greenberg, R., Williamson, R., Little, J., Mech, B., Cimmarusti, V., Van Boemel, G., Dagnelie, G., et al. (2003) · Vision Research · doi:10.1016/s0042-6989(03)00457-7 · Cited by 856
Self-citationSubretinal electronic chips allow blind patients to read letters and combine them to words
Zrenner, E., Bartz-Schmidt, K. U., Benav, H., Besch, D., Bruckmann, A., Gabel, V.-P., Gekeler, F., Greppmaier, U., Harscher, A., Kibbel, S., et al. (2011) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2010.1747 · Cited by 819
Schmidt, E. M., Bak, M. J., Hambrecht, F. T., Kufta, C. V., O'Rourke, D. K., & Vallabhanath, P. (1996) · Brain · doi:10.1093/brain/119.2.507 · Cited by 672
Genetic Reactivation of Cone Photoreceptors Restores Visual Responses in Retinitis Pigmentosa
Busskamp, V., Duebel, J., Bálya, D., Fradot, M., Viney, T. J., Siegert, S., Groner, A. C., Cabuy, E., Forster, V., Seeliger, M. W., et al. (2010) · Science · doi:10.1126/science.1190897 · Cited by 660
Preservation of the Inner Retina in Retinitis Pigmentosa
Santos, A. (1997) · Archives of Ophthalmology · doi:10.1001/archopht.1997.01100150513011 · Cited by 651
Lagali, P. S., Bálya, D., Awatramani, G. B., Münch, T. A., Kim, D. S., Busskamp, V., Cepko, C. L., & Roska, B. (2008) · Nature Neuroscience · doi:10.1038/nn.2117 · Cited by 580
Stone, J. L. (1992) · Archives of Ophthalmology · doi:10.1001/archopht.1992.01080230134038 · Cited by 480
Flagged first, then by citations
Research works printed but not linked: 1
- Watson AB. Temporal sensitivity. In: Boff KR, Kaufman L, Thomas JP, eds. Handbook of Perception and Human Performance. New York: Wiley; 1986.
Cited by
Sorted by citations
Items 101–164 of 164
Embracing the irregular: A patient-specific image processing strategy for visual prostheses
Kiral-Kornek, F. I., Savage, C. O., O'Sullivan-Greene, E., Burkitt, A. N., & Grayden, D. B. (2013) · 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6610312 · Cited by 9
“Phosphenes are taken from various sources in the literature of reported psychophysics tests [11], [7], [8], [4].”
BackgroundWu, J., Jin, M., & Qiao, Q. (2017) · BioMedical Engineering OnLine · doi:10.1186/s12938-017-0333-z · Cited by 5
“This may be helpful to increase brightness and the dynamic range of phosphene so that some electrodes are allowed to elicit phosphene that are previously unable to do so due to electrochemical safety limit restrictions and enhance the detection of visual information in retina [43, 44].”
BackgroundA Treatise of the Physical Aspects of Phosphenes and Single-Cell Selectivity in Retinal Stimulation
Villarreal, D. L., & Krautschneider, W. H. (2017) · International Journal of Computational & Neural Engineering · doi:10.19070/2572-7389-170008 · Cited by 5
“This may be caused by unintended stimulation of passing axons [54].”
BackgroundTowards Controlling Functionally-Distinct Retinal Ganglion Cells In Degenerate Retina
Muralidharan, M., Guo, T., Shivdasani, M. N., Tsai, D., Fried, S. I., Cameron, M. A., Morley, J. W., Dokos, S., & Lovell, N. H. (2020) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc44109.2020.9176595 · Cited by 6
“(17) also found that frequency modulation was more useful in the context of producing highresolution phosphenes with a greater range in brightness.”
BackgroundProceedings of the 16th Python in Science Conference
(2017) · doi:10.25080/shinma-7f4c6e7-000 · Cited by 6
Photovoltaic restoration of sight with high visual acuity in rats with retinal degeneration
Palanker, D., Goetz, G. A., Lorach, H., Mandel, Y., Smith, R., Boinagrov, D., Lei, X., Kamins, T. I., Harris, J. S., Mathieson, K., et al. (2015) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2081068 · Cited by 4
“, USA) is no better than 20/1260 (6), and the percepts are distorted due to axonal stimulation(10).”
Otgondemberel, Y., Roh, H., Fried, S. I., & Im, M. (2021) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2021.3128878 · Cited by 4
“In clinical trials, various amplitudes of electric stimulation are used for brightness modulation [49].”
BackgroundOh, S., Ahn, J.-H., Shin, J., Ko, H., Goo, Y., & Cho, D. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6943937 · Cited by 4
Are long stimulus pulse durations the answer to improving spatial resolution in retinal prostheses?
Petoe, M. A., & Shivdasani, M. N. (2016) · Annals of Translational Medicine · doi:10.21037/atm.2016.11.24 · Cited by 4
“Clinically in Argus II patients, it has been reported that phosphenes that should preferably be circular and confined are more-often perceived as elongated in the direction of axon fiber tracts passing directly below the stimulated electrode (6).”
BackgroundRetinal Prostheses: A Brief History
Yue, L., Weiland, J. D., & Humayun, M. S. (2017) · Essentials in ophthalmology/Essentials ophthalmology · doi:10.1007/978-3-319-67260-1_1 · Cited by 5
Stimulation strategies for selective activation of retinal ganglion cells
Chang, Y.-C., & Weiland, J. D. (2017) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2017.8008361 · Cited by 4
“However, clinical studies of patients with Argus II epiretinal implants reported most evoked percepts by single electrode were elongated and aligned with estimated axon path of retinal ganglion cells, suggesting the activation of axon bundles [4].”
Weitz, A. C., & Weiland, J. D. (2014) · Springer eBooks · doi:10.1007/978-1-4614-8151-5_7 · Cited by 4
Evaluating Deep Human-in-the-Loop Optimization for Retinal Implants Using Sighted Participants
Schoinas, E., Rastogi, A., Carter, A., Granley, J., & Beyeler, M. J. (2025) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc58623.2025.11253762 · Cited by 4
“This model represents phosphenes as multivariate Gaussian blobs, whose size, shape, and brightness are determined by both electrode location and stimulus properties such as amplitude, frequency, and pulse duration [9], [25], [26].”
29th Annual Computational Neuroscience Meeting: CNS*2020
Zeldenrust, F., Huang, C., Uijtewaal, P., Englitz, B., & Çelikel, T. (2020) · BMC Neuroscience · doi:10.1186/s12868-020-00593-1 · Cited by 3
Intraretinal stimulation with high density carbon fiber microelectrodes
Ghaffari, D. H., della Valle, E., Patel, P. R., Richie, J. M., Letner, J. G., Chestek, C. A., & Weiland, J. D. (2023) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner52421.2023.10123735 · Cited by 4
“Epiretinal prosthesis users report elongated percepts due to unintended stimulation of axons which activates off-target retinal ganglion cells (RGCs) [5].”
BackgroundRahmani, A., & Eom, K. (2024) · Frontiers in Cellular Neuroscience · doi:10.3389/fncel.2024.1385567 · Cited by 3
RASPV: A Robotics Framework for Augmented Simulated Prosthetic Vision
Pérez-Yus, A., Santos-Villafranca, M., Tomas-Barba, J., Bermúdez-Cameo, J., Montano-Oliván, L., Nicolás, G. L., & Guerrero, J. J. (2024) · IEEE Access · doi:10.1109/access.2024.3357400 · Cited by 3
“In a continuous attempt to improve the realism of the simulations of phosphenes, new spatial [34], [35], temporal [6], and spatiotemporal [36], [37] models have been introduced in the last few years based on reports from trials with implanted patients.”
BackgroundResultRetinal Prostheses for Restoration of Sight
Palanker, D. (2014) · Encyclopedia of Computational Neuroscience · doi:10.1007/978-1-4614-7320-6_665-1 · Cited by 3
Evaluating Deep Human-in-the-Loop Optimization for Retinal Implants Using Sighted Participants
Schoinas, E., Rastogi, A., Carter, A., Granley, J., & Beyeler, M. (2025) · arXiv · doi:10.48550/arxiv.2502.00177 · Cited by 3
“This model represents phosphenes as multivariate Gaussian blobs, whose size, shape, and brightness are determined by both electrode location and stimulus properties such as amplitude, frequency, and pulse duration [9], [25], [26].”
Human-in-the-loop optimization of visual prosthetic stimulation
Fauvel, T., & Chalk, M. (2021) · doi:10.1101/2021.11.24.469867 · Cited by 15
Yoon, Y. H., Yue, L., & Humayun, M. S. (2020) · Springer eBooks · doi:10.1007/978-981-15-7644-7_34 · Cited by 2
Perception of Dynamic Displays by People with Argus® II Retinal Prostheses
Christie, B. P., Sadeghi, R., Kartha, A., Ewulum, C., Caspi, A., Tenore, F. V., Klatzky, R. L., Dagnelie, G., & Billings, S. (2023) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner52421.2023.10123765 · Cited by 3
“Phosphenes can be made larger and/or brighter by increasing the amount of delivered current [12], but perceptual adaptation of the retina happens quickly (<500 ms) and causes phosphenes to fade and/or disappear altogether [13].”
BackgroundAn, N. H., Roh, H., Kim, S., Kim, J. H., & Im, M. (2025) · Advanced Science · doi:10.1002/advs.202405789 · Cited by 2
In vivo performance of photovoltaic subretinal prosthesis
Mandel, Y., Goetz, G., Lavinsky, D., Huie, P., Mathieson, K., Wang, L., Kamins, T. I., Manivanh, R. V., Harris, J. S., & Palanker, D. (2013) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2001750 · Cited by 2
“, “Ranibizumab and Bevacizumab for Treatment of Neovascular Age-Related Macular Degeneration: Two-Year Results,” Ophthalmology 119(7),1388-98 (2012).”
Background(2017) · Strategic Study of CAE · doi:10.15302/j-sscae-2017.02.017 · Cited by 2
Retinal Prostheses: Bioengineering Considerations
Chang, Y.-C., Weiland, J. D., & Humayun, M. S. (2017) · Essentials in ophthalmology/Essentials ophthalmology · doi:10.1007/978-3-319-67260-1_2 · Cited by 2
Selective activation of ganglion cells without axon bundles using epiretinal electrical stimulationPreprint
Grosberg, L. E., Ganesan, K., Goetz, G. A., Madugula, S. S., Bhaskar, N., Fan, V. H., Li, P., Hottowy, P., Dąbrowski, W., Sher, A., et al. (2016) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/075283 · Cited by 2
“Thus, it may be possible to precisely reproduce a portion of the neural code in an epiretinal prosthesis (Jepson et al., 2014a), while avoiding the distortions produced by axon activation in current clinical devices (Nanduri, 2011; Nanduri et al., 2012).”
BackgroundXie, H., Ye, Z., & Chan, L. L. H. (2025) · Scientific Reports · doi:10.1038/s41598-025-08657-0 · Cited by 2
Fuzzing the brain: automated stress testing for the safety of ML-driven neurostimulation
Downing, M., Peng, M., Granley, J., Beyeler, M., & Bultan, T. (2026) · Journal of Neural Engineering · doi:10.1088/1741-2552/ae4927 · Cited by 2
“This formulation incorporates well-established dependencies of phosphene brightness, size, and elongation on amplitude and frequency (Greenwald et al 2009, Horsager et al 2009, Nanduri et al 2012, Beyeler et al 2019).”
Optimizing retinal prosthesis stimulation: Enhancing the avoidance of unintended axonal activation
Alqahtani, A. M. (2026) · Journal of King Saud University - Science · doi:10.25259/jksus_1361_2025 · Cited by 1
Cécité et réhabilitation visuelle
Matonti, F., Roux, S., Denis, D., Picaud, S. A., & Chavane, F. (2015) · Journal Français d Ophtalmologie · doi:10.1016/j.jfo.2014.06.012 · Cited by 2
Photovoltaic retinal prosthesis for restoring sight to the blind
Palanker, D., Mandel, Y., Mathieson, K., Loudin, J., Goetz, G. A., Huie, P., Wang, L., Kamins, T. I., Smith, R., Harris, J. S., et al. (2015) · Cambridge University Press eBooks · doi:10.1017/cbo9781139629539.031 · Cited by 1
Avoidance of axonal activation in epiretinal implants using short biphasic pulses
Werginz, P., Corna, A., & Zeck, G. M. (2022) · Current Directions in Biomedical Engineering · doi:10.1515/cdbme-2022-2002 · Cited by 1
Electrical imaging of axonal stimulation in the retina
Corna, A., Lausen, T., Thewes, R., & Zeck, G. M. (2022) · Current Directions in Biomedical Engineering · doi:10.1515/cdbme-2022-2009 · Cited by 1
Simulation of electrode-tissue interface for electrical stimulation of retinal ganglion cells
Biswas, S., Das, S., & Mahadevappa, M. (2014) · IEEE International Conference on Electronics, Computing and Communication Technologies (CONECCT) · doi:10.1109/conecct.2014.6740341 · Cited by 1
The Bionic Eye: a review of multielectrode arrays
Fox, K. E., Burns, O., Garrett, D. J., Shivdasani, M. N., & Hamish Meffin, A. (2015) · Cambridge University Press eBooks · doi:10.1017/cbo9781139629539.029 · Cited by 1
The Development of Visual Prosthetic Devices to Restore Vision to the Blind
Weiland, J. D., Humayun, M. S., & Calle, A. G. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-805353-9.00101-7 · Cited by 1
Innovative Strategies for Treating Retinal Diseases
Straňák, Z., Kousal, B., Ardan, T., & Veith, M. (2019) · Czech and Slovak Ophthalmology · doi:10.31348/2019/6/1 · Cited by 1
Biphasic Current Stimulator for Retinal Prosthesis
Park, J. H., Wu, H., Tan, J. S. Y., & Yoo, J. (2022) · Springer eBooks · doi:10.1007/978-1-4614-3447-4_70 · Cited by 1
Fine, I., & Boynton, G. M. (2023) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2023.03.18.532424 · Cited by 1
Text image processing for visual prostheses
Wang, S., Li, Y., & Barnes, N. M. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346589
“The common observed shapes of the phosphenes elicited at the retina are approximately round or oval, curved, straight short lines, or in the form of wedges [5, 8, 9].”
BackgroundInfluentialProsthetic Vision, Perceptual Effects
Dagnelie, G., & Stronks, H. C. (2014) · Springer eBooks · doi:10.1007/978-1-4614-7320-6_657-1
Auditory and Visual Neural Prostheses
Shepherd, R. K., Seligman, P., & Shivdasani, M. N. (2016) · Wiley eBooks · doi:10.1002/9781118816028.ch7
Simulation of Electrode-Tissue Interface with Biphasic Pulse Train for Epiretinal Prosthesis
Biswas, S., Das, S., & Mahadevappa, M. (2013)
Testing stimulus protocols in retinal-prosthesis patients
Gonzalez-Calle, A., & Weiland, J. D. (2017) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2017.8037038
“The study was performed in patients implanted with the Argus I system [11].”
MethodPhotovoltaic stimulation efficiently evokes network-mediated activity of retinal ganglion cellsPreprint
Chenais, N. A. L., Leccardi, M. J. I. A., & Ghezzi, D. (2019) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/652404
Biphasic Current Stimulator for Retinal Prosthesis
Park, J. H., Wu, H., Tan, J. S. Y., & Yoo, J. (2021) · Springer eBooks · doi:10.1007/978-1-4614-6623-9_70-1
Prosthetic Vision, Perceptual Effects
Dagnelie, G., & Stronks, H. C. (2015) · Springer eBooks · doi:10.1007/978-1-4614-6675-8_657
Weiland, J. D., & Humayun, M. S. (2020) · Springer eBooks · doi:10.1007/978-3-030-43395-6_20
Djilas, M., & Picaud, S. A. (2014) · Advances in bioinformatics and biomedical engineering book series · doi:10.4018/978-1-4666-6094-6.ch002
Visual Prosthesis, Optoelectronic Devices
Palanker, D. (2018) · Springer eBooks · doi:10.1007/978-1-4614-7320-6_665-2
Visual Prosthesis, Optoelectronic Devices
Palanker, D. (2022) · Springer eBooks · doi:10.1007/978-1-0716-1006-0_665
Prosthetic Vision, Perceptual Effects
Dagnelie, G., & Stronks, H. C. (2022) · Springer eBooks · doi:10.1007/978-1-0716-1006-0_657
Lavoie, J., Besrour, M., Lemaire, W., Rouat, J., Fontaine, R., & Plourde, É. (2023) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/acf1a5
“It has been shown to be difficult to simultaneously modulate the size and brightness of phosphene [66].”
Simulador inmersivo de visión protésica modelando estímulos espacio-temporales
Santos-Villafranca, M., Tomas-Barba, J., Pérez-Yus, A., Bermúdez-Cameo, J., & Guerrero, J. (2023) · doi:10.17979/spudc.9788497498609.879
Short Pulse Epiretinal Stimulation Allows Focal Activation of Retinal Ganglion Cells
Koppenwallner, L. X., Zeck, G. M., & Werginz, P. (2025) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2025.3529940
“Classically, retinal implants and ex-vivo retinal stimulation apply pulses in the range of 50-500 µ s [9], [14], [28], [46], [47]; such pulse durations were shown to result in similar thresholds when the stimulating electrode was positioned above the soma or the distal axon.”
Emerging Biomaterials for Retinal Implants
Italiano, M. L., Guo, T., Tsai, D., Lovell, N. H., & Shivdasani, M. N. (2025) · Royal Society of Chemistry eBooks · doi:10.1039/9781839169779-00097
Using Virtual Patients to Predict Perceptual Outcomes for Optogenetic Sight Recovery TechnologiesPreprint
Fine, I., Mohan, V. B., Yücel, E., & Boynton, G. M. (2026) · Research Square · doi:10.21203/rs.3.rs-9284861/v1
“Simultaneous activation of all RGCs appears to produce bright percepts, although the mechanisms underlying this effect remain unclear 41 .”
A Dynamic Virtual Channel Approach to Enhance Retinal Prosthetic Precision
Liu, Z., Guo, T., He, Y., Zheng, S., Song, X., Dai, C., Li, J., Chai, X., Chen, Y., & Li, L. (2026) · Biomimetics · doi:10.3390/biomimetics11050307
Vision restoration: From prostheses to genetic-based brain–machine interfaces
Alcala, I., DESAILLY, E., Arcizet, F., Marazova, K., Gauvain, G., & Picaud, S. A. (2026) · Handbook of clinical neurology · doi:10.1016/b978-0-443-22212-2.00017-3
Metadata
- Authors
- Nanduri, D., Fine, I., Horsager, A., Boynton, G. M., Humayun, M. S., Greenberg, R. J., & Weiland, J. D.
- Affiliations
- Doheny Eye Institute (US)
- University of Southern California (US)
- University of Washington (US)
- Second Sight Medical Products (US)
- Corresponding author
- Nanduri, Devyani
- Fine, Ione
- Horsager, Alan
- Boynton, Geoffrey M.
- Humayun, Mark S.
- Greenberg, Robert J.
- Weiland, James D.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2012-01-20
- Volume
- 53
- Issue
- 1
- Pages
- 205
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- PMC
- PMC3292357
- OpenAlex
- W1976408315
- Cited by
- 163
- References
- 55
- Citations by year
- 2026: 6 · 2025: 8 · 2024: 7 · 2023: 10 · 2022: 17 · 2021: 11 · 2020: 18 · 2019: 9 · 2018: 12 · 2017: 14 · 2016: 11 · 2015: 14 · 2014: 14 · 2013: 9 · 2012: 2
- FWCI
- 3.31
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Investigative Ophthalmology & Visual Science (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Eye Institute (R01EY014645, R01EY012893, P30EY001730)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Health Sciences › Medicine › Ophthalmology › Retinal Development and Disorders
- Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
- Keywords
- epiretinal prosthesis, retinitis pigmentosa, pulse amplitude, brightness perception, retinal stimulation, spatial resolution
- MeSH terms
- Blindness, Electrodes, Implanted, Electric Stimulation Therapy, Follow-Up Studies, Humans, Microelectrodes, Middle Aged, Retina, Retinitis Pigmentosa, Sensory Thresholds, Visual Perception, Treatment Outcome
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review