The DOI matches its Crossref record; 55 of the 55 references it cites were found in a registry or an index.
Frequency and Amplitude Modulation Have Different Effects on the Percepts Elicited by Retinal Stimulation
Open accessAbstract
PURPOSE: In an effort to restore functional form vision, epiretinal prostheses that elicit percepts by directly stimulating remaining retinal circuitry were implanted in human subjects with advanced retinitis pigmentosa RP). In this study, manipulating pulse train frequency and amplitude had different effects on the size and brightness of phosphene appearance. METHODS: Experiments were performed on a single subject with severe RP (implanted with a 16-channel epiretinal prosthesis in 2004) on nine individual electrodes. Psychophysical techniques were used to measure both the brightness and size of phosphenes when the biphasic pulse train was varied by either modulating the current amplitude (with constant frequency) or the stimulating frequency (with constant current amplitude). RESULTS: Increasing stimulation frequency always increased brightness, while having a smaller effect on the size of elicited phosphenes. In contrast, increasing stimulation amplitude generally increased both the size and brightness of phosphenes. These experimental findings can be explained by using a simple computational model based on previous psychophysical work and the expected spatial spread of current from a disc electrode. CONCLUSIONS: Given that amplitude and frequency have separable effects on percept size, these findings suggest that frequency modulation improves the encoding of a wide range of brightness levels without a loss of spatial resolution. Future retinal prosthesis designs could benefit from having the flexibility to manipulate pulse train amplitude and frequency independently (clinicaltrials.gov number, NCT00279500).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Consistent with Nanduri et al (2012), we found that stimulus amplitude strongly affected phosphene area in two out of three participants (p < .001) and minor axis length (p < .001), suggesting that phosphenes tended to get larger with increasing amplitude.”
From Axonal stimulation affects the linear summation of single-point perception in three Argus II users (2024) · cites this paper as Nanduri et al 2012
In the citing paper
“In addition, phosphene appearance varies systematically with stimulus amplitude and frequency (Horsager et al 2009, Nanduri et al 2012, Sinclair et al 2016) to the extent that a simple computational model can predict phosphene shape across a wide range of stimulus parameters (Granley and Beyeler 2021).”
From Axonal stimulation affects the linear summation of single-point perception in three Argus II users (2024) · cites this paper as Nanduri et al 2012
In the citing paper
“First reported by Nanduri et al (2012), pulse frequency seemed to affect phosphene shape differently than amplitude (figure 6).”
From Axonal stimulation affects the linear summation of single-point perception in three Argus II users (2024) · cites this paper as Nanduri et al 2012
In the citing paper
“However, in contrast to Nanduri et al (2012), we found that stimulus frequency also affected phosphene size (table 4 and figure 6).”
From Axonal stimulation affects the linear summation of single-point perception in three Argus II users (2024) · cites this paper as Nanduri et al (2012)
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stevens, S. S. (1957) · Psychological Review · doi:10.1037/h0046162 · Cited by 3,388
Hauswirth, W. W., Aleman, T. S., Kaushal, S., Cideciyan, A. V., Schwartz, S. B., Wang, L., Conlon, T. J., Boye, S. L., Flotte, T. R., Byrne, B. J., et al. (2008) · Human Gene Therapy · doi:10.1089/hum.2008.107 · Cited by 954
Neural remodeling in retinal degeneration
Marc, R. E., Jones, B. W., Watt, C. B., & Strettoi, E. (2003) · Progress in Retinal and Eye Research · doi:10.1016/s1350-9462(03)00039-9 · Cited by 891
Visual perception in a blind subject with a chronic microelectronic retinal prosthesis
Humayun, M. S., Weiland, J. D., Fujii, G. Y., Greenberg, R., Williamson, R., Little, J., Mech, B., Cimmarusti, V., Van Boemel, G., Dagnelie, G., et al. (2003) · Vision Research · doi:10.1016/s0042-6989(03)00457-7 · Cited by 856
Self-citationSubretinal electronic chips allow blind patients to read letters and combine them to words
Zrenner, E., Bartz-Schmidt, K. U., Benav, H., Besch, D., Bruckmann, A., Gabel, V.-P., Gekeler, F., Greppmaier, U., Harscher, A., Kibbel, S., et al. (2011) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2010.1747 · Cited by 819
Schmidt, E. M., Bak, M. J., Hambrecht, F. T., Kufta, C. V., O'Rourke, D. K., & Vallabhanath, P. (1996) · Brain · doi:10.1093/brain/119.2.507 · Cited by 672
Genetic Reactivation of Cone Photoreceptors Restores Visual Responses in Retinitis Pigmentosa
Busskamp, V., Duebel, J., Bálya, D., Fradot, M., Viney, T. J., Siegert, S., Groner, A. C., Cabuy, E., Forster, V., Seeliger, M. W., et al. (2010) · Science · doi:10.1126/science.1190897 · Cited by 660
Preservation of the Inner Retina in Retinitis Pigmentosa
Santos, A. (1997) · Archives of Ophthalmology · doi:10.1001/archopht.1997.01100150513011 · Cited by 651
Lagali, P. S., Bálya, D., Awatramani, G. B., Münch, T. A., Kim, D. S., Busskamp, V., Cepko, C. L., & Roska, B. (2008) · Nature Neuroscience · doi:10.1038/nn.2117 · Cited by 580
Stone, J. L. (1992) · Archives of Ophthalmology · doi:10.1001/archopht.1992.01080230134038 · Cited by 480
Flagged first, then by citations
Research works printed but not linked: 1
- Watson AB. Temporal sensitivity. In: Boff KR, Kaufman L, Thomas JP, eds. Handbook of Perception and Human Performance. New York: Wiley; 1986.
Cited by
Sorted by citations
The Argus® II Retinal Prosthesis System
Luo, Y. H.-L., & da Cruz, L. (2016) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2015.09.003 · Cited by 351
Photovoltaic restoration of sight with high visual acuity
Lorach, H., Goetz, G., Smith, R., Lei, X., Mandel, Y., Kamins, T. I., Mathieson, K., Huie, P., Harris, J. S., Sher, A., et al. (2015) · Nature Medicine · doi:10.1038/nm.3851 · Cited by 341
Retinal stimulation strategies to restore vision: fundamentals and systems
Yue, L., Weiland, J. D., Roska, B., & Humayun, M. S. (2016) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2016.05.002 · Cited by 272
“2) Phosphene brightness increased as a function of stimulation amplitude and frequency but phosphene size exhibitedmuch higher dependence on the amplitude than frequency (de Balthasar et al., 2008; Nanduri et al., 2012).”
Self-citationPhotovoltaic Restoration of Central Vision in Atrophic Age-Related Macular Degeneration
Palanker, D., Le Mer, Y., Mohand-Said, S., Muqit, M., & Sahel, J. A. (2020) · Ophthalmology · doi:10.1016/j.ophtha.2020.02.024 · Cited by 227
An update on retinal prostheses
Ayton, L. N., Barnes, N., Dagnelie, G., Fujikado, T., Goetz, G., Hornig, R., Jones, B. W., Muqit, M. M. K., Rathbun, D. L., Stingl, K., et al. (2020) · Clinical Neurophysiology · doi:10.1016/j.clinph.2019.11.029 · Cited by 223
“Amplitude-modulation of brightness is more practical to implement, but it has been reported that the size of the percept increases with amplitude whereas the effect on size is smaller with increases in stimulation frequency (Nanduri et al., 2012; Sinclair et al., 2016).”
Background
Metadata
- Authors
- Nanduri, D., Fine, I., Horsager, A., Boynton, G. M., Humayun, M. S., Greenberg, R. J., & Weiland, J. D.
- Affiliations
- Doheny Eye Institute (US)
- University of Southern California (US)
- University of Washington (US)
- Second Sight Medical Products (US)
- Corresponding author
- Nanduri, Devyani
- Fine, Ione
- Horsager, Alan
- Boynton, Geoffrey M.
- Humayun, Mark S.
- Greenberg, Robert J.
- Weiland, James D.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2012-01-20
- Volume
- 53
- Issue
- 1
- Pages
- 205
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- PMC
- PMC3292357
- OpenAlex
- W1976408315
- Cited by
- 163
- References
- 55
- Citations by year
- 2026: 6 · 2025: 8 · 2024: 7 · 2023: 10 · 2022: 17 · 2021: 11 · 2020: 18 · 2019: 9 · 2018: 12 · 2017: 14 · 2016: 11 · 2015: 14 · 2014: 14 · 2013: 9 · 2012: 2
- FWCI
- 3.31
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Investigative Ophthalmology & Visual Science (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Eye Institute (R01EY014645, R01EY012893, P30EY001730)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Health Sciences › Medicine › Ophthalmology › Retinal Development and Disorders
- Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
- Keywords
- epiretinal prosthesis, retinitis pigmentosa, pulse amplitude, brightness perception, retinal stimulation, spatial resolution
- MeSH terms
- Blindness, Electrodes, Implanted, Electric Stimulation Therapy, Follow-Up Studies, Humans, Microelectrodes, Middle Aged, Retina, Retinitis Pigmentosa, Sensory Thresholds, Visual Perception, Treatment Outcome
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review