PreprintCited by 3Neuroscience and Neural EngineeringTactile and Sensory InteractionsEEG and Brain-Computer Interfaces

Evaluating Deep Human-in-the-Loop Optimization for Retinal Implants Using Sighted Participants

Open access
Schoinas, Eirini, Rastogi, Adyah, Carter, Anissa, Granley, Jacob, Beyeler, Michael·2025·arXiv

Abstract

Human-in-the-loop optimization (HILO) is a promising approach for personalizing visual prostheses by iteratively refining stimulus parameters based on user feedback. Previous work demonstrated HILO's efficacy in simulation, but its performance with human participants remains untested. Here we evaluate HILO using sighted participants viewing simulated prosthetic vision to assess its ability to optimize stimulation strategies under realistic conditions. Participants selected between phosphenes generated by competing encoders to iteratively refine a deep stimulus encoder (DSE). We tested HILO in three conditions: standard optimization, threshold misspecifications, and out-of-distribution parameter sampling. Participants consistently preferred HILO-generated stimuli over both a naive encoder and the DSE alone, with log odds favoring HILO across all conditions. We also observed key differences between human and simulated decision-making, highlighting the importance of validating optimization strategies with human participants. These findings support HILO as a viable approach for adapting visual prostheses to individuals. Clinical relevance: Validating HILO with sighted participants viewing simulated prosthetic vision is an important step toward personalized calibration of future visual prostheses.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

DataCite · 10.48550/arxiv.2502.00177

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • This approach allowed inclusion of patient's preferences for stimulation parameters optimization and was proposed in two studies, one using virtual patients and one using real sighted patients under SPV.

    “This approach allowed inclusion of patient’s preferences for stimulation parameters optimization and was proposed in two studies, one using virtual patients96 and one using real sighted patients under SPV.99”

    From Visual Prostheses in the Era of Artificial Intelligence Technology (2025) · cites this paper as [99]

    The Introduction and Task sections describe sighted participants viewing simulated prosthetic vision and using their preferences to optimize simulated stimulation. However, the Participants section identifies them as undergraduate students with normal or corrected-to-normal vision and no reported visual impairment, not patients. The separate virtual-patient study is attached to a different citation. (LLM, conf=0.88)

    Experimental — accuracy not yet measured
  • Another approach consisted in using human-in-the-loop optimization to improve the perceived image in a simulated prosthetic vision setting.

    “Another approach consisted in using human-in-the-loop optimization to improve the perceived image in a simulated prosthetic vision setting.96,99”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 13

  1. K. Stingl, R. Schippert, K. U. Bartz-Schmidt, D. Besch, C. L. Cottriall, T. L. Edwards, F. Gekeler, U. Greppmaier, K. Kiel, A. Koitschev, L. Kühlewein, R. E. MacLaren, J. D. Ramsden, J. Roider, A. Rothermel, H. Sachs, G. S. Schröder, J. Tode, N. Troelenberg, and E. Zrenner, "Interim Results of a Multicenter Trial with the New Electronic Subretinal Implant Alpha AMS in 15 Patients Blind from Inherited Retinal Degenerations," Frontiers in Neuroscience, vol. 11, 2017, publisher: Frontiers. [Online]. Available: https://www.frontiersin.org/articles/10.3389/fnins.2017.00445/full · DOI
  2. M. P. Barry, R. Sadeghi, V. L. Towle, K. Stipp, H. Puhov, W. Diaz, P. Grant, F. T. Collison, F. J. Lane, J. P. Szlyk et al., "Preliminary visual function for the first human with the Intracortical Visual Prosthesis (ICVP)," Investigative Ophthalmology & Visual Science, vol. 64, no. 8, pp. 2842-2842, 2023.
  3. M. Beyeler, D. Nanduri, J. D. Weiland, A. Rokem, G. M. Boynton, and I. Fine, "A model of ganglion axon pathways accounts for percepts elicited by retinal implants," Scientific Reports, vol. 9, no. 1, pp. 1-16, Jun. 2019. [Online]. Available: https://www.nature.com/articles/s41598-019-45416-4
  4. N. C. Sinclair, M. N. Shivdasani, T. Perera, L. N. Gillespie, H. J. McDermott, L. N. Ayton, and P. J. Blamey, "The Appearance of Phosphenes Elicited Using a Suprachoroidal Retinal Prosthesis," Investigative Ophthalmology & Visual Science, vol. 57, no. 11, pp. 4948-4961, Sep. 2016. [Online]. Available: https: //iovs.arvojournals.org/article.aspx?articleid=2556019
  5. M. P. Barry, M. Armenta Salas, U. Patel, V. Wuyyuru, S. Niketeghad, W. H. Bosking, D. Yoshor, J. D. Dorn, and N. Pouratian, "Video-mode percepts are smaller than sums of single-electrode phosphenes with the Orion® visual cortical prosthesis," Investigative Ophthalmology & Visual Science, vol. 61, no. 7, p. 927, Jun. 2020.
  6. J. Granley and M. Beyeler, "A Computational Model of Phosphene Appearance for Epiretinal Prostheses," Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference, vol. 2021, pp. 4477-4481, Nov. 2021. [Online]. Available: https://www.ncbi.nlm.nih.gov/pmc/articles/ PMC9255280/
  7. I. Fine and G. M. Boynton, "A virtual patient simulation modeling the neural and perceptual effects of human visual cortical stimulation, from pulse trains to percepts," Scientific Reports, vol. 14, no. 1, p. 17400, Jul. 2024, publisher: Nature Publishing Group. [Online]. Available: https://www.nature.com/articles/s41598-024-65337-1
  8. J. Granley, L. Relic, and M. Beyeler, "Hybrid Neural Autoencoders for Stimulus Encoding in Visual and Other Sensory Neuroprostheses," in Advances in Neural Information Processing Systems, vol. 35, Dec. 2022, pp. 22 671-22 685. [Online]. Available: https://papers.nips.cc/paper files/paper/2022/hash/ 8e9a6582caa59fda0302349702965171-Abstract-Conference.html
  9. J. Granley, T. Fauvel, M. Chalk, and M. Beyeler, "Human-in-the-Loop Optimization for Deep Stimulus Encoding in Visual Prostheses," in Advances in Neural Information Processing Systems, Nov. 2023. [Online]. Available: https://openreview.net/forum?id=ZED5wdGous
  10. E. Prashnani, H. Cai, Y. Mostofi, and P. Sen, "PieAPP: Perceptual Image-Error Assessment Through Pairwise Preference," in 2018 IEEE/CVF Conference on Computer Vision and Pattern Recognition, Jun. 2018, pp. 1808-1817, conference Name: 2018 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR) ISBN: 9781538664209 Place: Salt Lake City, UT Publisher: IEEE. [Online]. Available: https://ieeexplore.ieee.org/document/8578292/
  11. L. M. Turkstra, T. Bhatia, A. Van Os, and M. Beyeler, "Assistive technology use in domestic activities by people who are blind," Scientific Reports, vol. 15, no. 1, p. 7486, Mar. 2025, publisher: Nature Publishing Group. [Online]. Available: https://www.nature.com/articles/s41598-025-91755-w
  12. F. Drakopoulos, A. Van Den Broucke, and S. Verhulst, "A DNN-Based Hearing-Aid Strategy For Real-Time Processing: One Size Fits All," in ICASSP 2023 -2023 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP), Jun. 2023, pp. 1-5, iSSN: 2379-190X. [Online]. Available: https://ieeexplore.ieee.org/abstract/document/10094887
  13. N. A. Lesica, N. Mehta, J. G. Manjaly, L. Deng, B. S. Wilson, and F.-G. Zeng, "Harnessing the power of artificial intelligence to transform hearing healthcare and research," Nature Machine Intelligence, vol. 3, no. 10, pp. 840-849, Oct. 2021, publisher: Nature Publishing Group. [Online]. Available: https: //www.nature.com/articles/s42256-021-00394-z

Cited by

Sorted by citations

Authors
Schoinas, E., Rastogi, A., Carter, A., Granley, J., & Beyeler, M.
Affiliations
University of California, Santa Barbara (US)
Venue
arXiv
Publisher
arXiv
Published
2025
Volume
2025
Pages
1-6
ISSN
2375-7477 (ISSN-L)
OpenAlex
W4416962888
Cited by
3
References
21
Citations by year
2026: 2 · 2025: 1
FWCI
18.82
Type
conference paper
Language
en
Open access
Locations
  • Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) (publishedVersion)
  • PubMed (publishedVersion)
  • PubMed Central (publishedVersion, cc-by)
  • arXiv (Cornell University) (submittedVersion, cc-by)
  • arXiv (Cornell University) (cc-by)
Funders
  • National Institutes of Health
  • U.S. National Library of Medicine (DP2LM014268)
  • HORIZON EUROPE Health
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
  • Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
Keywords
human-in-the-loop optimization, retinal prosthesis, phosphenes, personalized stimulation, simulated prosthetic vision, user feedback
MeSH terms
Adult, Female, Humans, Male, Visual Prosthesis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review